| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being reasonable and Lowest L1 |
| 2 | L2₹1.4 Cr+₹2.4 L (1.74%)Rejected-Finance 600 R 2 PADAMA ICHHA APARTMENT BIRBAL SAHINI MARG LUCKNOW U P PIN 226001 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | ₹1.4 Cr+₹2.4 L (1.74%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.4 Cr+₹3.6 L (2.70%)Rejected-Finance FLAT NO 201 GF KAMAL VIHAR CGHS LTD PLOT NO 5 SECTOR 7 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.4 Cr+₹3.6 L (2.70%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.5 Cr+₹13.4 L (9.95%)Rejected-Finance | ₹1.5 Cr+₹13.4 L (9.95%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹1.5 Cr+₹14.9 L (11.0%)Rejected-Finance | ₹1.5 Cr+₹14.9 L (11.0%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
10 Jun 2020, 6:00 pmClosed
Col SS Bose CWE
HQ CWE (AF) Chakeri, Kanpur 208008
SPECIAL REPAIR REPLACEMENT OF BER CENTRAL AIR CONDITIONING PLANT AT M 53 OVERHAULING BAY AT 4 BRD AT AF STN KANPUR
2020_MES_341238_1
82133/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chakeri, Kanpur
Class B Cat c (i)
8 documents required · 8 mandatory
₹1,000
GE (AF) E/M Chakeri
₹2.2 L
31 Jul 2020
27 Apr 2020
18 Jun 2020
27 Apr 2020
10 Jun 2020
20 May 2020
Amount
SCH 'A' PART-I AC PLANT WORK AND CIVIL WORKS:- Dismantling and taking down old central AC plants various type comprising compressors, compressor motors, condenser pumps,cooling tower,AHU,panel board with control switches, condenser water pipe lines, etc. and all connected items including demolition of foundation from M-53 over hauling bay (H No-11) 240 TR ( 6 x 40 TR) Plant for facilating replacement of BER plants with new plants and removing from site all as directed. Note:- AC duct shall be removed upto plenum level and AC ducting inside building shall not be dismantled & neither it is part of schedule of credit. All other items are part of schedule of credit.
Supply, Installation, Testing & Commissioning of water cooled scroll chiller units having minimum capacity 80 TR with multi scroll compressor with microprocessor control. The Unit shall have compressor mounting arrangement on rubber Grommets with metal sleeves. Water cooled shell & tube type condenser. DX type evaporator duly insulated. Thermostatic expansion valve with Extl. Equalizer. Unit shall have filter dryer, pressure switch i.e. HP/LP, Electronic Thermostat Flow switch at chiller, Integral Refrigerant Piping & wiring, Accessories as required and called for, automatic and safety control mounted in central console Electronic microprocessor with soft starter panel central overloaded protector including comprising of following accessories/ facilities: (A) Mode: (i) Auto/Manual (ii) Single Phasing Protection. (iii) Compressor Restart Protection. (iv) 10- Sec Time Delay between System. (v) Short Circuit Protection 5°C - Anti Freeze Protection. (vi) Display on Micro control indicating . (vi) Display on Micro control indicating compressor on, (vii) Crankcase Heater ON/Off, Entering/Leaving water Temp (B) Refrigerant: (viii) R-407c or any other non CFC/non HCFC gas. (ix) Actual capacity as per Ambient condition. (x) Scroll Chiller Unit shall be suitable for 400 V±10%, 50 C/S, 3 Phase Ac Supply. (C) Chiller (xi) Chilled water Inlet Temp. 12˚ C. (xii) Chilled water outlet Temp. 7˚ C, (xiii) Chilled water flow rate: 260 USG PM (xiv) Fouling Factor: 0.000088 m².K/W (D) Condenser (xv) Condenser water Inlet Temp. 32.5˚C (xvi) Condenser water outlet Temp. 37.5˚ C. (xvii) Condenser water flow rate: 310 USG PM guration:
Supply, installation, testing and commissioning of AHU for operation of supply and return air application suitable capacity, indoor type, draw through type of sectionalized construction, factory made, floor mounted double skin type made of 25mm thick modular AHU panels with GI casing of thickness 24 Gauge outside layers and 24 Gauge inside layer injected with CFC free polyurethane foam (PUF) of 38 kg/cum density insulation complete with blower section, chilled water cooling coil section, filter section with muffler and access door to attend the motor/fan with lighting provisions and all accessories capacity not less than 30000 CFM including necessary PCC foundation with vibration isolators all as specified and as directed.including comprising of following :- (i) Cooling coil of 6 row deep copper tube with aluminium fins with automatic controlled+ anti-freeze thermostat . (ii) Blower section complete with blower having forward curved centrifugal fan for weather maker suitable for desired static pressure as specified , with minimum 2 bends GSS eliminators with suitable capacity TEFC squirrel cage induction motor (IP-55 and class F insulation) for operation on 3 phase 415 volt 50 HZ AC supply with belt driven pulley. (iii) 50 mm thick washable type pre-filters with filter element made out of synthetic non woven media supported by HDPE mesh on both side including stitching in diamond pattern complete including frame and suitable for efficiency 90% down to 10 micron EU-3 Type complete with mounting frame work. (iv ) Secondary dry type cleanable and easily maintainable air filter supported by GI wire and folder to form accordion plate having an efficiency of 99% down to 5 micron EU-5 TYPE complete with mounting frame works. (v) Drain connection, stainless steel (SS304 Grade) drain pan and with necessary GI pipe for drain out the condensate to the open drain of the building. (vi) Humidification system complete with monoblock pump set of suitable size, water tank, pipe line & sprinkler as required at site with fully automatic arrangement for operation with humidistat.
Supply, installation, Testing & Commissioning of DDC controller & DDC panel (IP-54 protection). This unit shall stand-alone type. The unit shall able to control and monitor return air temp/RH. Temp shall be controlled with the help of 3-way modulating valve and RH shall be monitor with the help of heater installed in AHU. The DDC controller should comprise of temp./RH sensor & programmable operator terminal for monitor & control. The DDC controller panel shall have instrument and Micro-controller panel & Field device. Instrument and Micro-controller panel shall be wall mounting type, duly wired and tested with following features:- (i) Fully programmable (ii) Complete protection for A/C from unhealthy condition. (iii) All set points programmable from keypad. (iv) Password protection for controller. (v) 16 Char. 2 lines LCD display with back light, on controller front panel. (vi) Four key interface for on site programming. (vii) Separate Alarm contacts for A/C fail alarm. (viii) Automatic display of A/C parameters one by one in Run mode. (ix) Status & healthy indication by LED on front panel. (x) Alarm indication by LED on front panel. (xi) Room Temp sensing by precise sensor. (xii) Direct display of actual room temperature. (xiii) All faults Auto reset.
The DDC controller panel also supply, installation and testing of following field devices. i) Room temp. sensor at return air path. (1 No) ii) Room temp. thermostates in condition area. (1 No). iii) Air flow switch in electrical heater section, electrical heaters shall be controlled in one or more steps by return air temp, and interlock with airflow switch installed in the electrical heater section of AHU. Electric heater cannot be in operation without supply air flow. (1 No) iv) An automatic reset thermal cut off switch shall be provided which will stop the electric heater when the high limit temperature is reached. Electric heater shall reset automatically, when the related return air temperature drops blow setting point, winter heater shall be operate only on running of AHU Fan. Note: While installing DDC controller, instrument and Micro-controller panel and field devices they shall be integrated with each other. Note: Panel shall be fabricated by CPRI certifiied vender.
Supply, installation, testing and commissioning of APFC panel of cap 100 KVAR with 7% detuned reactors. APFC panel shall be cubical type, constructed from 16 SWG CRCA sheet steel, suitable for indoor installation . Dust/ vermin proof floor mounted. with IP-42 protection . Panel should be powder coated and as per IS-7032 shade. Incoming feeder (i) Incoming feeder shall be of 200 Amps,50KA TP+NL MCCB thermal megnatic setting type ,O/L,S/C& E/F ,volt meter, Amp Meter,APFC meter,CTs, Indicating lamp etc. (A) Out going Feeder No-01 (i) 50 KVAR capacitor bank - 01 No (ii) MCCB thermal magnetic, TP+NL, 25KA, 415V, 50HZ,125 Amps-01No (B) Feeder No-02 (i) 20 KVAR capacitor bank -01 No (ii) MCCB thermal magnetic, TP+NL, 16 KA, 415V, 50HZ,40 Amps-01No (C) Feeder No-03 (i) 10 KVAR capacitor bank -03 No (ii) MCCB thermal magnetic, TP+NL, 16 KA, 415V, 50HZ,20 Amps-03No
Supply,installation,testing and commissioning of Induced draft type not less than 200 TR cooling tower of FRP complete with All Accessories, basin, fittings, fan, fan motor etc. with following technical data with necessary RCC foundation as per manufacturers standard specification including by-pass arrangement for non interruption in operation of AC plant while cleaning or replacing of strainer complete all as specified and directed.
Supply, installation, testing & commissioning of centrifugal pump sets factory assembled & tested for rated efficiency complete with TEFC motor & common base frame, coupling guard, cladded insulation etc. for re-circulation of condensed water from cooling tower to condenser for the air conditioning system. The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply all as specified and directed by Engineer-in-charge. Make :- KSB/ Crompton Graves / Beacon/Kirlosker. The pump characteristic of centrifugal pump set shall be as follows: a. Water quantity 310 US GPM b. Static Head 18 Metre c. Impeller Bronze
Supply, installation, testing & commissioning of centrifugal pump sets, factory assembled & tested for rated efficiency complete with TEFC motor & common base frame, coupling guard, cladded insulation etc. for re-circulation of chilled water for the air conditioning system. The pumps shall be suitable for operation on 415 ± 10% Volts, 50 Hz, 3 Phase AC power supply complete all as specified and directed by Engineer-in-charge. Make :- KSB/ Crompton Graves / Beacon/Kirlosker. The pump characteristic of centrifugal pump set shall be as follows: a. Water quantity 260 US GPM b. Static Head 18 Metre c. Impeller Bronze.
Supply & Fixing Flexible canvass Connection for AHU's/package units to duct including zib superior quality all as specified and directed.
Supply and fixing of GI. Volume Control Dampers with matching flanges complete all as specified and directed.
Supply and fixing fresh air arrangement with VCD,Louvers and Bird screen complete all as specified and directed.
Supply and installation of supply air square ceiling diffusers, flush mounting, suitable for 4 way throw, core removable type powder coated with opposed blade damper. The frame and core shall be constructed from high quality aluminium profile with necessary hardware complete all as specified and directed.
Supply and fixing aluminium extruded powder coated return /supply air grill with Volume control dampers with matching flanges horizontal fixed bar of 12 Nos,1.2mm thick and 11.5mm spacing with 0/15/30 degree deflection (ISI marked) complete all as specified and directed.
Supply and fixing aluminium extruded powder coated return/supply air grill without Volume control dampers with matching flanges horizontal fixed bar of 12 Nos,1.2mm thick and 11.5mm spacing with 0/15/30 degree deflection (ISI marked) complete all as specified and directed.
Supply and fixing of mechanical fire dampers fusible type approved for 90 minutes fire rating as per UL-555-1995 in main supply air duct including control wiring. The dampers shall be made of heavy gauge galvanized steel having multi blade construction. The blades shall be fitted with chrome plated shaft and self lubricated phosphorus bronze bushes. The dampers shall also be provided with jam seal (compression type) on sides to prevent spread of smoke and fire. The blades of the dampers are held in the ‘open’ position by a high tensile spring and a fusible link. The fusible link should be UL stamped and operates at 74˚C, causing the damper to close immediately on break fire to prevent the spread of fire through the ducts all as specified and as directed. Note: Operation fire dampers shall be locked with AHU & AC plant. In case of shutdown of fire dampers AHU & AC plant should shutdown automatically.
Supply and fixing of heater bank 9 x 9 KW (9x3KW+9x3KW+9x3KW) for winter heating complete all as specified and directed.
Supply and fixing of heater bank 6x9 KW (6x3KW+6x3KW+6x3KW) for humidity control complete all as specified and directed.
Supply and fixing of humidistat complete all as specified and directed by Engineer-in-charge.
Supply and fixing of digital temp & humid display system showing ambient temp, humidity AHU No 1 temp and humidity necessary control wiring and sensor complete all as specified and directed.
Supply and fixing Thermostat complete all as specified and directed.
Supply ,laying, jointing and testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 Sq mm 3½ core complete all as specified and directed.
Supply ,laying, jointing and testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sq mm 3½ core complete all as specified and directed.
Supply ,laying, jointing and testing of XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sq mm 3½ core complete all as specified and directed.
Supply and fixing of PVC sheathed copper cable of size 50 Sqmm 3½ core, superior quality, laying over GI slotted cable tray including necessary supports and frame work complete all as specified and directed.
All as per Srl Item No. 24 above but size 35 Sqmm 3½ core
All as per Srl Item No. 24 above but size 10 Sqmm 4 core
All as per Srl Item No. 24 above but size 6 Sqmm 3 core
All as per Srl Item No. 24 above but size 1.5 Sqmm 2 core
Supply and fixing of GI slotted cable tray 150 width x 50mm depth made out of 1.6 mm thick galvanised MS sheet including width including necessary supports and frame work complete all as specified and as directed.
Supply and fixing of GI slotted cable tray 300mm width x 50mm depth 1.6 mm thick galvanised MS sheet including necessary supports and frame work complete all as specified and as directed.
M & L earthing complete with Galvanized steel earth electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth electrode not less then 1.5 Mtr below normal ground level connected to GI strip of size 32x6mm as earth lead by means of bolts, check nuts and washers of galvanized iron or steel, connected to earth test point including earth strip from earth electrode to test point , GI pipe 40mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common salt, excavation and earth work earth pit with PCC 1:3:6 type CI (using 20 mm graded stone aggregate) precast RCC cover 1: 2 :4 type B1 using 20mm graded stone aggregate 40 mm thickness reinforced with 3 Nos TMT bars 8mm dia both ways, funnel with wire mesh, testing and rest as shown in electrical plate No-3 of SSR-I including complete all as specified and directed. Note: Earthing strip and protection pipe upto 7.5 meter length shall be deemed to be included in the quoted unit rate . Earthing strip beyond 7.5 meter shall be measured and paid separately.
M & L earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less then 1.5 Mtr below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts,nuts, check nuts and washers of galvanized iron or steel incl excavation and earth work,PCC 1:3:6 type C-1 chamber with RCC cover 1:2:4 type B0 40mm thick, reinforced with 8 mm dia TMT bar, 3 Nos both way,15mm dia light grade GI protection pipe, funnel with wire mesh watering GI pipe of 20mm dia light grade and lugs including charcoal dust, common salt, and testing etc. all as shown in electrical plate No.3 of SSR Part I of 2009. Note: Earthing lead and protection pipe upto 7.5 meter length shall be deemed to be included in the quoted unit rate . Earthing strip beyond 7.5 meter shall be measured and paid separately
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm complete all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4mm dia complete all as specified and directed.
Supply, laying, testing and commissioning of Galvanised Iron 'heavy grade ' condenser water pipes with complete fittings such as bends, tees, elbows, reducers, flanges, special fittings, suspension hangers, etc. complete all as specified and directed of following sizes. (a) 150 mm dia
All as per Srl Item No. 35 above but size 100 mm dia
All as per Srl Item No. 35 above but size 50 mm dia
All as per Srl Item No. 35 above but size 40 mm dia
Supply and fixing of Butterfly valves Cast Iron body, Wafer type integrally moulded close end body construction with Hand liver operated and rating of PN-10 complete all as specified and directed of following sizes. (a) 150 mm dia
All as per Srl Item No. 39 above but size 100 mm dia
Supply and fixing of 100 mm dia Dual Plate Check Valves Cast Iron body & Rating of PN -10 complete all as specified and directed.
Supply and fixing of Y- Strainers Cast Iron body & Rating of PN-10 of size 150mm dia complete all as specified and directed.
Supply and fixing of Y- Strainers Cast Iron body & Rating of PN-10 of size 100mm dia complete all as specified and directed.
Supply, laying, testing and commissioning of chilled water piping of MS pipes-'C' class confirming to IS : 1239/3589 heavy class including all fittings such as couplings, bends, tees, elbows, reducers etc piping shall be supported with frame structure, necessary hardware's clevis support i e U strap clamps etc trust blocks of rubber material having density 1400 Kg/mᵌ etc.insulation shall be with half round section of PUF in density 36±2 Kg/mᵌ confirming to IS 12436 section shall be banded to the surface of pipe with adhesive fevicol SR 998 and binded with metal binding wire apply fevicol AC duct lag coating AF: 5590 on insulated surface uniformly and wrap the glass cloth tightly with over lapping so that no gaps are left and no air pockets are formed. immediately apply additional coating as finish layer on the wrap cloth and finally finish with aluminium cladding 28 gauge with necessary hardware fitting. (a) 100 mm dia.
All as per Srl Item No. 44 above but size 80 mm dia
All as per Srl Item No. 44 above but size 50 mm dia
All as per Srl Item No. 44 above but size 40 mm dia
Supply and Fixing of Butterfly Valves, Cast Iron body, Wafer type integrally moulded close end body construction with Hand liver operated and rating of PN-10 with insulation of following size complete all as specified and directed . (a) 100 mm dia
All as per Srl Item No. 48 above but size 80 mm dia
All as per Srl Item No. 48 above but size 40/50 mm dia
Supply and fixing of Cast Iron flanged Balancing Valves of size 80 mm dia with pressure test cocks only in EN-3 Stem EN-3 disc and EPDM sealing Disc with PN -10 with insulation complete all as specified and directed.
Supply and fixing of Dual Plate Check Valves of size 80/100 mm dia Cast Iron body & Rating of PN -10 with insulation complete all as specified and directed.
Supply , installation, testing and commissioning of 80 mm three way motorised modulating valves with modulating motor and thermostat etc. complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding etc. as per requirement complete all as specified and as directed.
Supply and fixing of Ball valves/ purge Valve of size 25 mm dia with insulation complete all as specified and directed.
Supply and fixing water flow switches complete all as specified and as directed.
Supply and fixing of Pressure 4" Dia Gauges of Burden Type, stainless steel or CP brass stem complete with Globe valves confirming to IS - 3624 complete all as specified and directed.
Supply and fixing of Bimetal Dial type temperature Gauge of 100 mm dia. of suitable range with adjustable stem complete all as specified and directed .
Supply and laying of condensate drain water piping with MS pipes 40mm dia and necessary fittings like elbows, tees, reducers etc complete all as specified and directed.
Supply and fix 10000 Ltr PVC Make Up Tank two layer with Overflow Valve, Float Valve and connection to cooling tower all as specified and directed. Note : Quoted rate shall be deemed to be included for cost of make up tank, overflow valve, float valve and GI pipe complete.
Supply and fixing of 500 Ltr PVC Make Up Tank three layer white and including required thermal insulation as per requirement of chilled water make up tank of AC plant and Overflow Valve, Float Valve and connection to chilled water pipeline with 32 mm dia GI 'heavy grade' pipe of required length complete all as directed and as specified. Note: Quoted unit rate shall be included cost of make up tank, thermal insulations, over flow valve, float valve and GI pipe etc complete.
Supply, fabrication installation and testing of GSS metal ducts 1.0 mm thick sheet as per IS 277 (120 GSM both sides LFQ & confirming to class VIII) for GS sheets and IS-655 for fabrication of following thickness including necessary G.I hangers/supports, volume control duct dampers, accessories vanes, 3 mm WPDM rubber gasket etc. complete as per specification in accordance with the approved shop drawing : the cost shall be inclusive of following: (i) Ducts with reinforcement/ strengthening. (ii) Air tight joints. (iii) Accessories such as splitter, damper, guide vane etc. (iv) Hangers, Fastener and supports; Rectangular duct should be support from ceiling/wall with bracket/Gripple wire/hanger etc. Section should be as per site condition and drawing. (v) Painting with black colour paint for duct sides behind the grills. (vi) The gasket used in case for all ducts shall be fire retardant type
All as per Srl Item No. 61 above but metal ducts 0.80mm thick
S&F structural rolled mild steel joist, channel, angle, tee or flat section conforming to grade Fe 410-O or Fe 310-O fixed independently, without connecting plates etc. as in duct supports including tie bars with screwed etc complete all as specified and directed .
Supply and laying of acoustic insulation of duct with 25 mm fibre glass rigid board covered with 28 Gauge Aluminium perforated sheet and RP tissue complete all as specified and as directed.
Supply and laying of thermal insulation of duct with 19 mm thick nitrile rubber sheet insulation having density 50 kg/cum and fixing with adhesive as per the recommendation of the manufacturer complete all as specified and directed.
M&L aluminium cladding of insulated duct using 0.5mm thick aluminium sheet complete all as specified and directed.
Outgoing (a) 3 Nos for chiller units and spare 03 Nos - 200 Amp., 50KA, 415V TP+NL MCCB with adjustable thermal settings, overload and short circuit release including door interlocking device, front operating handle , ON and OFF indication of LED module, bus bar extension for connecting cables etc. complete in all respects. (b) 03 Nos for Chilled water pump 03 Nos 32 Amp., 25KA, 415V TP MCCB with adjustable thermal with starter suitable for chilled water motor rating AC 3 duty 415V 50Hz 3 Phase motor. The starter shall be with single phase prevention & electronic timer, with sufficient auxiliary contacts for remote on/off indication lamp by metallic thermal over load relay of suitable size current rating, on/off push button suitable wired and inter connected with 4 sq mm single stranded PVC copper wire etc. complete in all respect (c) 03 Nos for Condenser water pump 03 Nos 32 Amp., 25KA, 415V TP MCCB with adjustable thermal settings, with starter suitable for condenser water motor rating AC 3 phase 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitable wired and interconnected with 4.0 Sq.mm single stranded PVC copper wire, etc, complete in all respects. (d) 02 Nos for AHU control panel 02 Nos 250 Amp., 36 KA, 415V TP+NL MCCB with adjustable thermal settings. (e) 01 Nos for Cooling Tower, 01 Nos 63Amp., 25KA, 415V TP MCCB with adjustable thermal settings, with starter suitable for cooling Tower motor rating, AC 3 duty 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc., complete in all respects. (f) 01 Nos for APFC panel. 1 No 160 Amp 36KA, 415V TP+NL MCCB with adjustable thermal settings
Supply & fixing cubical type vermin proof dust proof IP-54 factory made by the manufacturer having type test report of CPRI approved wall mounted LT electric panel board totally enclosed with separate chambers for bus bars cable entry exist and digital volt and Ampere Meter complete internal wiring with suitable size of copper conductor multi standard, indicator lamp etc. Suitable for 3 phase 415 Volt 50 Hz and having anodised copper bus bar (4 Nos of 400 Amp) fabricated from 2 mm thick CR CA sheet powder coated through 7 Tank process facility for pricking and degreasing duly interconnected for wall mounting type panel all as specified and directed by engineer in charge with the following (For AHU control panel) (a) Main incoming MCCB 3 Pole 250 Amp 36 KA 415 V 50 Hz- 01 Nos (b)Out going MCCB 3 Pole 63 Amp 25KA 415 V 50 Hz- 01 Nos, with starter suitable for AHU of 30000 CFM capacity motor rating, AC 3 duty 415V, 50Hz. The starter shall be with single phase prevention and electronic timer, with sufficient auxiliary contacts for remote ON/OFF indication lamps, bi-metallic thermal overload relay of suitable size current rating, ON/OFF push buttons suitably wired and interconnected with 6.0 Sq.mm single stranded PVC copper wire, etc., complete in all respects. (c) 40 Amps MCCB 3 Pole with suitable power contactor for heater starter system -06 Nos (d) MCB SPN 32 Amp 10KA 230 V 50 Hz- 03 Nos (DDC controller panel)
M&L for complete cleaning of ducts by using HEPA filtered vacuum unit of plant of 160 TR AC plant complete from AHU to last user end air grill and running to creative negative pressure in the duct system by placing the same outside the occupied space by using variety of tools to agitate and loosen the dust, which shall be then drawn into the vacuum unit and contained therein. The cleaning shall be done by the robotic video camera for cleaning the hard to reach areas which are out of reach most Duct cleaning equipment. Access cutting can be made if required and shall later be refitted with screw and sealant. All floors and furnishing where the work will be carried out on shall be covered and complete care shall be taken to avoid minimum amount of cross contamination upon completion of work. The system shall be scrutinized by tagging the duet to ensure all mold and bacteria spores and foul smell is eradicated the entire process is carried out with Air compressor with bib pneumatic air whips and power jobs. Rotary brush drawn vacuum with pipe. Negative machine HEPA and 10" hose pipe and robotic camera with control unit. All cleaning Agents/Chemicals used shall be incorporated with the regulation and shall be certified for use in the respective system all as specified and directed.
Supply, installation, Testing & commissioning water softening plant considering water softening flow rate of 2 cum/Hrs with inlet hardness given 105 PPM and hardness of outlet will be less than 5 PPM for condenser water circuit complete all as specified and directed.
S& F control cable PVC insulated PVC sheathed copper conductor 3 core 1.5 sqmm 1100 volt grade and testing complete all as specified and directed.
Supply and fixing GI pipe medium grade 40 mm bore of pipe with all new fittings laid in trenches of following lines complete all as specified and directed Note: The above schedule (serial item No 01 to 72) is for replacement of 02 Nos central AC palnt (6x40 TR) with one No central AC palnt 3x80 TR. The contractor shall submit the general layout plan before starting for approval of GE. The civil work the foundation of equipments as per manufacturer's recommendation, pipe supports, duct supports etc given in the specifications shall be deemed to be included in the quoted unit rate.
Dismantling of floor, hearth or wall tiles / terrazo including cement mortar bedding (but not backing),removal servicable tiles to store and rubbish off the premises, all as specified and directed.
M&L Rendering 10 mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces for fixing wall tiles/kota stone complete all as specified and directed.
M & L 15mm thick Screed bed or bedding layer in CM (1:4) for laying floor tiles etc, complete all as specified and as directed.
M&L 300x200x 7mm thick glazed coloured ceramic tiles(Ist quality) as in vertical surface set & jointed in neat cement slurry and pointed in white/coloured cement to match the shade of tiles all as specified and directed.
M&L 18-20 mm thick machine cut factory polished Kota stone slab on vertical surfaces sch as skirting etc set& jointed in neat cement slurry and pointed in coloured cement complete all as specified and directed.
M&L for 18-20 thick machine cut factory polished kota stone slab in floors ,setand jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
Demolition of Brickwork masonry, built in cement mortar complete all as specified and directed .
M &L Brickwork with fly ash old size bricks, straright or curved on plan exc 6m mean radius built in Cement mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster of any description on brick or stone walls or concrete surfaces etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement and mixing with water proofing compound of cement 3% by weight complete all as specified and directed. (Note :- WPC shall be measured and paid separately.)
M & L rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound.
M & L rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement complete all as directed
M&L rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished fair and even complete all as specified and directed.
Complete removal of existing treatment on walls/coloumns, bracings, etc complete all as specified and directed.
Complete removal of existing treatment on ceiling complete all as specified and directed.
M&L preparing the new plastered surfaces and applying two coats of cement base paint on walls all as specified and direcrted.
M&L preparing the new plastered surfaces and applying three coats of white wash on walls complete all as specified and direcrted.
M & L preparing the new plastered surfaces and applying two coats of white wash on ceilings complete all as specified and directed.
M&L applying three coats of white wash on walls/coloumns all as specified and direcrted.
M&L applying two coats of cement base paint on walls all as specified and direcrted.
M & L applying two coats of white wash on ceilings all as specified and direcrted.
M & L preparation of old painted wooden surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L one coat of synthetic enamel paint including preparation of old decorated steel surfaces of any description over 10 Cm width or girth not otherwise described complte all as specified and directed.
M & L writing letters or figures (Block, Roman, Italic or Indian) n exc 30 cm high complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and directed.
S & F factory made 35mm thick, 2nd class HW, plain framed, panelled shutter (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
Supply & fixing IInd class hardwood (Hollock) plain solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F Butt hinges of 100 mm size, Medium weight, cold rolled mild steel and fixed complte all as specified and directed.
S&F 250 mm long mild steel sliding door bolts, ISI marked clip type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed
S & F 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
S & F 150mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed.
Supply & Fixing MS work as in hold fast etc conforming (Fe-410-0 or Fe-310-0) complte all as specified and directed.
Material & labour PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in hold fast, PCC Bed blocks incl finished all exposed surfaces of concrete incl necessary form work etc complte all as specified and directed.
M&L preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified & directed.
M&L one coat of synthetic enamel paint including preparation of old decorated steel surfaces of any description over 10 Cm width or girth not otherwise described complte all as specified and directed.
M & L 15mm thick Screed bed or bedding layer in CM (1:6) for laying floor tiles etc, complete all as specified and directed.
Material and Labour for chequered Cement concrete tiles 20 cm X20cm X 25 mm thick, set jointed and pointed in neat cement slurry with mixture of white and grey cement in equal proportion and no pigment complete all as specified & directed.
Demolition of plain cement Concrete of any description over roof slab and removing outside MD land complete all as specified and s directed.
M & L 25mm thick cement concrete (1:2:4) type B0, using 12.5mm graded stone aggregate mixed with WPC @ 3.00 % by weight of cement complete all as specified and directed. Note:- WPC shall be measured & paid separately.
M & L wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, etc., and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.7 kg per sq.m and blinded complete all as specified and directed.
M & L brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directed.
M & L applying water proofing treatment with one coat of cold applied polymeric e0.40 litre per sqm and applying of a layer of App based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric(wt. not less than 150 gms/sqm) land on primed surface by forced application. Side over lap shall be 75mm and at the ends shall be 100mm and all over laps and joints shall also be sealed by torch application complete all as specified and directed.
M & L 20mm thick Screed bed or bedding layer in CM (1:6) for laying floor tiles, complete all as specified and directed.
M & L cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed, set jointed and pointed in neat cement slurry with grey cement and no pigments, in floors, cut and polished complete all as specified and directed by the Engineer-in-Charge complete all as specified and directed.
M & L providing, cement concrete in roof typeB0 1:2:4 (12.5mm graded) for copings, kneelers, apex stones, bed plates, kerbs not provided for complete all as specified and directed.
SCH 'A' PART-II ( MANNING AND OPERATION OF AC PLANT) : Manning and operation of central AC plant of 3x80 TR capacity at M-53 overhauling bay having compressors with its connected items such as condensers/chillers, water circulating pumps, chilling pumps, blowers, blower motor, cooling tower with fan and motor including connected starters etc in all respect for smooth running of AC plants during the running period to maintain designed Air conditioning/chilled water temperature inside the building/ block from 06:00 hrs to 22:00 hrs (Two shift of 08 hours) every day except holidays and sundays as observed by the air force authority and cleaning of all equipments and sweeping inside and outside of the installation and maintaining of log sheet on daily basis and proper dress code followed by the operator complete and tightning of pump gland, filling of new gland and new gland nut bolts and electrical complaints of motor pump and panel and starter will be attended and rectified by the contractor without any extra cost for smooth function of plant all as specified and as directed (a) 3 x 80 TR AC Plant at M-53 overhauling bay at 4 BRD for the first year of defect libility period
All as per ser item No 119 (a) above, but for second year of defect libility period. Note for Srl item No. 119 (a) & 120:- (i) Cleaning of all AC plants, machinery and inside and outside location is the responsibility of contractor. (ii) If any operator found absent from duty Rs. 3000/- per day will be recovered from the contractor. (iii) If the contractor failed to commence the work on due date Rs. 2000/- per installation per day will be recovered from the contractor till commencement of the work. (iv) Contractor will provide police verification of all operator before commencement of work (v) Before commencement of work contractor will provide all documents such as educational qualification, ID proof of operator in duplicate. (vi) Contractor will be maintain Attendance Register, Visitor register, maintenance record register, daily log sheet, operator payment register and produce every month to the Engineer-in- Charge. (vii) The contractor should be employed only ITI holder in the specific trade (viii) The operator deployed shall be in uniform indicating the name of individual and firm.
SWASTIKA ENGINEER
SHRI RAMSONS PROJECTS CORPORATION
BRITE INDUSTRIES
M/s R.V. Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .