| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹26.7 L+₹1.3 L (5.18%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹26.8 L+₹1.4 L (5.58%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹25.3 L
EMD Value
₹50,500
Closing Date
23 Dec 2024, 6:00 pmClosed
VIPIN CHANDRA RAI
GARRISON ENGINEER UTILITY BATHINDA
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
2024_MES_675155_2
8822/2024-25/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GARRISON ENGINEER UTILITY BATHINDA
Class D Cat b i
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER UTILITY BATHINDA
₹50,500
Yes
23 Jan 2025
7 Nov 2024
25 Dec 2024
7 Nov 2024
23 Dec 2024
7 Dec 2024
Amount
General maint of AMF Panel and DG set including Cleaning of dust using blower & cleaning agents. Checking/Detecting, Removal of Faults, Re-wiring of old u/s wiring & Testing of Control Wiring complete as reqd and closing of AMF Panel after replacement of u/s parts and fault finding of DG set engine ,leakage arresting of engine/diesal oil from filter by tightening of filter ,setting of AVR ,fan belt setting ,tightening of battery terminal . The contractor will depute sufficiant mechanic or electritian for fault finding and rectification .The contractor shall collect complain regarding unserviceability of DG or AMF panel from JE EM ,after collecting of complain slip comlain would rectified within 6 hours ,if fauls fine of 500 Rs per 24 hour shall impose on contractor .After completion of job work the testing on existing load as specified & directed by Engineer-in-Charge. Note:-1) The contractor shall deposited the old material retrieved from item no 01 to 19 to AGE EM store yard and shall maintain the record for the same .
S&F in replacement of AMF Panel outdoor type, 125KVA DG Set with alluminium busbar of capacity 350 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of four pole 250 Amps .The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
INCOMING from 125 KVA (i) MCCB 200 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders Link- 02 Set (iii) Extended Rotary handle - 01 No (iv) Power Contactor 200 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (v) C.T. 200/5A CL-1.0 10 VA - 06 Nos (vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (vii) Indicating lights (Red-2, Yellow-2. Green-2) (viii) Control MCB 6A SP 10 KA C curve (ix) VMR - 01 No (x) In built on load change over switch four pole 250A four pole for bypassing of AMF panel - 01 No (XI) Engine start relay -01 Nos
Outgoing (i) MCCB 200 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (vii) Hooter - 01 No (viii) PROCOM UNIT (DGC6D) FOR control - 01 No (ix)Extended Rotary handle - 01 No (x) engine start relay 12 V DC
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
S&F in replacement of AMF Panel outdoor type, 100KVA DG Set with alluminium busbar of capacity 250 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of four pole 200 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
INCOMING from 100 KVA (i) MCCB 160 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders Link - 01 Set (iii) Extended Rotary handle - 01 No (iv) Power Contactor 160 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 200/5A CL-1.0 10 VA - 06 Nos (vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch four pole 200A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 160 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 160 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle - 01 No (x) engine start relay 12 V DC
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
S&F in replacement of Automatic transfer switch with AMF controller Procom DGC6D and Inbuilt battery charger 12 V 10 A of capacity 40 A four pole type with sheet metal enclusure for DG set of 25KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .HAVEELS CAT PART NO IHRFBAE040
S&F in replacement of Automatic transfer switch with AMF controller Procom DGC6D and Inbuilt battery charger 12 V 10 A of capacity 63 A four pole type with sheet metal enclusure for DG set of 40KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .HAVEELS CAT PART NO IHRFBAE063
S&F in replacement of AMF Panel outdoor type, 200KVA DG Set with alluminium busbar of capacity 500 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of Four pole 400 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
INCOMING from 200 KVA (i) MCCB 400 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders link- 01 Set (iii) Extended Rotary handle - 01 No (iv) Power Contactor 300 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 400/5A CL-1.0 10 VA - 06 Nos (vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch 400A four pole for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 400 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 300 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 24V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle - 01 No (xii) Engine start Relay=01 NOs
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
S&F in replacement of AMF Panel outdoor type, 62.5KVA DG Set with alluminium busbar of capacity 200 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of four pole 125 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
INCOMING from 62.5 KVA (i) MCCB 100 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders Link - 01 Set (iii) Extended Rotary handle - 01 No (iv) Power Contactor 125 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No (vi) C.T. 100/5A CL-1.0 10 VA - 06 Nos (vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No (xi) In built on load change over switch four pole 125A for bypassing of AMF panel - 01 No
Outgoing (i) MCCB 100 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 125 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No (iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No (v) Emergency stop P.B - 01 No (vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No (x) PROCOM UNIT (DGC6D) FOR control - 01 No (xi)Extended Rotary handle - 01 No (xii) Engine start Relay -01 Nos
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
M&L for Earthing complete with slotted galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion.
Labour only for laying of LT cable of any size which issued by MES under Sch B as directed by Engineer in charge .Note :- The LT cable will be issued to contractor under Sch B.
Taking out of old LT cable of any size as directed
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil.
Returning, filling in,including spreding ,levelling ,watering and well ramming in layers not exceeding 25 cm thick complte all as specified and as directed by Engineer-in-charge
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
M&L for Sand cusioning of river sand for XLPE cable with screened & washed sand & punning to provide a required cover.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm as directed
Repair/overhauling of self starter i/c replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing complete all as directed for the following capacity :-
12 Volts
24 Volts
Supply & Fixing in repair of DC 12V Solenoid Coil left/right suitable for DG Set
Supply & Fixing in repair of DC 24V Solenoid Coil left/right suitable for DG Set
Labour only for fixing of material issued to contractor Under Sch B as directed by engineer in charge as under :-
Dynamo 12V/24V
Fan Belt
Contactor 4 pole of various capacity
Contractor coil of various capacity
Autocut Electrical Battery Charger Unit DC 12V/24 V 10 A SMPS
Voltage Monitor Relay
Timer AC/DC on Delay
Indicating lamp set RYB
Engine Start Relay, 12 /24 VDC,
Annunciator Units, For Fault
DC ammeter and Voltmeter
6x1.5 Sqmm Multistrand Copper Conductor Control Cable for DG Set to AMF Panel
AMF Controller(PROCOM UNIT)
AVRs of various capacity
Fuel Pipe
Coolent
Engine oil
DG set canopy Hinjes
Battery Terminal of Dg set
Relay card for amf panel
Battery Distilled Water
DG set controller cummins PSO600
MCCBs of vaious sizes
Note: The contractor shall deposited the old material retrieved from item no 01 to 19.24 to AGE EM store yard by his own arrangement without any financial benefit and shall maintain the record for the same as specified by Engr-In-Charge and GE.
DIAMOND SALES COROPORATION (BID ID -3196592)
M/s GURFATEH BUILDERS (BID ID -3196629)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .