Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC 1551 5 CHARANJEEV COLONY KAITHAL 1551 5 CHARANJEEV COLONY KAITHAL 136027 | KAITHAL | HARYANA | 136027 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹27.8 L+₹4.1 L (17.1%)Rejected-Finance T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹30.5 L+₹6.8 L (28.5%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹31.1 L+₹7.4 L (30.9%)Rejected-Finance ROOM NO A 46 GALI NO 11 GANESH MURTHY NAGAR PART NO 3 CAPT PRAKASH PETHE MARG CUFFE PARADE COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹31.7 L+₹7.9 L (33.5%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,600
Closing Date
27 Jun 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE OF INTERNAL WATER SUPPLY INCLUDING LOFT TANKS AND ALLIED WORKS FOR RS AREA UNDER GE NW NAVY NAGAR COLABA MUMBAI
2022_MES_527572_1
8202/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE(NW)Navy Nagar, Colaba
Class D and Category a(ii)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹90,600
Yes
13 Jul 2022
31 May 2022
28 Jun 2022
31 May 2022
27 Jun 2022
14 Jun 2022
31 May 2022 - 20 Jun 2022
Amount
Supply and fixing in repair/ replacement of internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings (Inside and outside) in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge of following sizes :- Note :- Necessary safety equipment and scaffolding for repair/replacement work shall be provided by the contractor without any charges. All safety measures shall be strictly followed while carrying out the repair/replacement work.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50mm bore
Supply & fix in repair of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltrs with gross capacity of tank at least 5% in excess of minimum net capacity including 03 Nos adapter with washer for inlet/outlet overflow pipe as per manufactureres instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge.
Supply and fix in repair/replacement of PVC profile suitable for 275 ltrs loft tank including fixing of aluminium channel around the profile complete all as specified and directed.
Supply and fix in repair/replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge. Note:- Necessary safety equipment and scaffolding for repair/replacement work shall be provided by the contractor without any charges. All safety measures shall be strictly followed while carrying out the repair/replacement work.
Supply and fix in repair CP stop cock, screwed down with crutch or butterfly handle suitable for GI tubing/CPVC Pipe 15 mm dia bore including necessary clamp & saddles all as specified.
Supply and fix in repairs CP bib cock, with crutch or butterfly handle screwed both ends for GI tubing/CPVC Pipe 15 mm dia bore including necessary clamp & saddles etc all as specified.
Dismantling of existing connection and taking out pressure reducing valve of size 25 mm bore cleaning servicing and refixing at existing location in high rise buildings (G+14) including provision of fittings, I.e. union, elbow, bend, nipple, etc. complete to make the line functional all as specified.
Supply and fix in repair brass float valve (ISI marked) high pressure with polythelene float (flat) and fly nut complete screwed for GI pipe 15mm bore including necessary GI fittings/CPVC fittings such as elbow, reducer, nipple etc.
All as per item No 8.00 above but for GI pipe 20 mm bore
All as per item No 8.00 above but for GI pipe 25 mm bore
All as per item No 8.00 above but for GI pipe 40 mm bore
Supply and fix in repair/replacement of gun-metal, gate valve in existing line in position with iron wheel head class I, made out of brass, screwed both ends for GI pipe with union, ISI marked complete all as directed of the following sizes :-
25 mm bore
40 mm bore
50 mm bore
S&F in repairs shower rose CP 125mm dia swivel type suitable for 15mm bore GI tubing/CPVC pipe all as specified and directed by Engineer-in-Charge."
Taking out existing unserviceabe FRP and supply & fix in repair lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 5000 Ltrs as approved BMC.
Taking out existing unserviceabe FRP and supply & fix in repair lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 2000 Ltrs as approved BMC.
Taking out existing unserviceabe FRP and supply & fix in repair lid cover for PVC water storage tank complete with accessories for closing and locking arrnagement suitable for 1000 Ltrs as approved BMC.
Taking down GI tubing fixed to wall at location cleaning and refixing the same with clamping on wall including provision of necessary fitting in high rise building (G+15 stories) for the following sizes: Note:- Necessary safety equipment and scaffolding for repair/replacement work shall be provided by the contractor without any charges. All safety measures shall be strictly followed while carrying out the repair/replacement work.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Supply and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adapter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge.
Disconnecting carefully water and electric connection from storage type gyser of 25 ltrs capacity of any make and dismantling for repair/maintenance by taking out siphon /geyser assembly , thermostat, heating elements, indication lamps and all necessary accessories and cleaning, de-scaling the inner tank by de-scaling chemical compound including soldering, brazing the inner tank if required, re-assembling the geysers after cleaning & servicing including replacement of flexible 3 core cable of size 2.5 sqmm with copper conductor up to 1.5 mtr long and refixing in existing position complete all as specified and directed. Note :- (i) Heating element, thermostat, indication lamp, safety valve & Siphon/geyser assembly shall be measured and paid under relevant items. (ii) The rate quoted is deemed to include the cost of soldering /brazing/control wiring of geyser , air release valve and glass wool supirior quality if required.
Supply and fixing in repair heating elemant of capacity of 1500 Watts (triangle type/circular type) for 25 Ltr geysers.
Supply and fixing in repairs of Thermostat suitable for 25/50 ltrs capacity water storage geyser with automatic thermal cut out fixed in repair and including testing, complete all as specified.
Supply and fixing in repairs of copper Geyser / siphon Assembly with rubber packing for 25/50 ltrs capacity water geyser with automatic thermal cutout fixed in repair and including testing, complete all as specified.
Supply and fixing in repairs of Safety valve for geyser chromium plated brass 15 mm dia all as specified and directed.
Supply and fixing in repairs of indication lamps suitable for 25/50 ltrs water storage geyser all as specified and directed.
Taking down usnerviceable PVC conncetions for cold and hot water of geyser and supply and fix new PVC flexible connection pipe heavy duty 15 mm size with PTMT nuts on both ends of length 450 mm with two washers, suitable for cold water connection to geyser all as specified and directed.
Attending ,repair of internal and external water supply complaints in New Navy Nagar area ,repair, replacement of unserviceable bib tap,stop cock removal of airlock,tightening of leaking pipes/valves ,repair to concealed pipe line/open pipe line, Complaints of Raw water pipe line and fittings and other work pertains to internal water supply all as directed. Note: (a) Major items required to be replaced will be measured and paid separtely under revelant schedule. (b) Complaints should be taken from complaint cell or also through telephone by JE E/M and AGE W/S by your representative every day including sunday and holiday. (c) Complaints should be attended immediately and shall report the JE E/M / Engineer-in-charge after completion within 6 Hours. (d) In case the nature of job is such that the work cannot be completed within a period of 6 hours then the same shall be brought to the notice of the GE/ AGE W/S and the period for the completion of the complaints shall be decided by the GE/Engr-in-charge. (e) Contractor representative /Engineer will report to JE E/M in charge or AGE E/M at forenoon and afternoon to collect routine urgent works till completion of the CA . (f) The transportation /T&P required for the work shall be arranged by the contractor and no extra cost will be paid for the same.
S& F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, of size Fe 410-W(GdeE- 250) quality A or all as specified and directed by Engineer-in-Charge. (ii) Cost of making necessary holes in wall making good the disturb surfaces using cement and sand mortar for fixing iron section is deemed to be including in the rate quoted.
Supply and fix in repairs of CP mixer 3-in-1 system with provision for both hand shower and overhead shower complete with 115 mm long bend pipe, connecting legs & wall flanges type for mixing hot & cold water screwed down for iron pipe and fixed all as specified and directed by Engineer-in-Charge.
S & F in repairs PP-R Gate valves 50 mm bore (brass insert) with iron wheel head screwed both ends for PP-R including fittings ie union socket etc complete all as specified
S& F in repair 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UVstablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc of following sizes.
Supply and fix sticker of size 200 mm x 50 mm with back ground colour light blue written (SAVE WATER) with font colour white of letter size 25 mm all as specified and directed by Engineer-in-Charge.
Shetty Construction Co
M/S V N ENTERPRISES
jkconstruction
SHRI SAI ENTERPRISES
BOB ENTERPRISES
Anil Industrial Corporation
ASHOK ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .