Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LRejected-Finance 68 1 MOHALLA NALAPUR NARNAUL DISTRICT MOHINDERGARH HRY 123001 123001 | NARNAUL | MOHINDERGARH | HARYANA | 123001 | L1 | Rejected-Finance EMD REFUND ONLY | |
| 2 | Rejected-Technical | - | Rejected-Technical Non-Responsive | |
| 3 | Rejected-Technical | - | Rejected-Technical Non-Responsive |
Tender Value
₹19.8 L
EMD Value
₹40,000
Closing Date
31 Aug 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Provl Division PWD Narnaul
Executive Engineer, Provl Division PWD Narnaul
Construction Library at village Surana in Mahendergarh District. (Re-invited)
2022_HRY_233978_1
Library at village Surana (Rs. 19.80 lakh)-Re-invi
Open Tender
Civil Works - Buildings
Item-rate/Agreement basic
120 days
Works
Construction Library at village Surana in Mahendergarh District. (Re-invited)
3 documents required · 3 mandatory
₹1,000
₹40,000
Yes
26 Jan 2023
10 Aug 2022
1 Sept 2022
11 Aug 2022
31 Aug 2022
11 Aug 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (1) All Kind of Soil. (HSR 4.12.1)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. (HSR 4.32).
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (HSR 4.33).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded stone aggregate 40 mm nominal size) (HSR 6.1.6).
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.21.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 : 1 ½: 3 ( 1 Cement: 1 ½ coarse sand (zone-Ill) : 3 cum graded stone aggregate 20 mm nominal size) (HSR 6.1.1).
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (6) Thermo-Mechanically Treated bars of grade Fe-500D or more. (HSR 6.33.6)
20 mm thick cement plaster damp-proof course 1:3 with 2 coats of bitumen at 1.65 kg. per sqm, laid hot and sanded: (1) Vertical. (HSR 6.12.1).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. (HSR 6.13).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 330 kg/cum. Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix). (HSR 6.25).
All works above plinth level up to floor IV level. (HSR 6.25.2)
Centering and shuttering including strutting, propping etc. and removal of form work for: (HSR 6.29). Foundations, footings, bases for columns. (HSR 6.29.1)
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (HSR 6.29.2).
Centering and shuttering including strutting, propping etc. and removal of form for:- Suspended floors, roofs, landings, balconies and access platform. (HSR 6.30.3).
Lintels, beams, plinth beams, girders, bressumers and cantilevers. (HSR 6.30.5).
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor four level in cement mortar 1:6 (1 cement : 6 coarse sand): With non-modular bricks. (HSR 7.23.1)
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in superstructure above plinth level up to floor IV level. (2) Cement mortar 1:4 (1 cement :4 coarse sand). (HSR 7.28.2).
Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete : (1) With residual type petroleum bitumen of grade VG -10. (HSR 9.10.1).
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (1) With common burnt clay non-modular brick tile of class designation 10. (HSR 9.11.1).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : (1) In 75x75 mm deep chase. (HSR 9.17.1).
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18).
Supplying and fixing in position 60 cm long G.I. pipe class ‘B’ spouts in chajjas and cantilevers. (5) 50 mm internal dia. (HSR 9.55.5).
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 9.57.3)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (5) Bend 87.5°. (HSR 9.58.5.3) 150 mm diameter
Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. (HSR 10.1).
Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping. (HSR 10.4).
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58).
Providing and fixing vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (2) Size of Tile 600x600 mm. (HSR 10.63.2).
Providing and fixing Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. (2) Size of Tile 600x600 mm. (HSR 10.67.2).
10 mm thick cement plaster. (2) 1:3 (1 cement: 3 fine sand). (HSR 11.4.2).
12 mm cement plaster of mix: (4) 1:6 (1 cement: 6 fine sand). (HSR 11.5.4).
15 mm cement plaster on the rough side of single or half brick wall of mix : (2) 1:6 (1 cement: 6 fine sand). (HSR 11.6.2)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60).
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: (1) New work (two or more coats) over and including water thinnable priming coat with cement primer. (HSR 11.64.1)
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (2) Kiln seasoned and chemically treated Hollock wood. (2) 30 mm thick. (HSR 12.10.2.2)
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: (2) 30 mm thick shutters. (1) with ISI marked M.S. pressed butt hinges bright finished of required size. (2) 30 mm thick. (HSR 12.19.2.1.2).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws(HSR 12.37.3).
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (HSR 13.29.2)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (2) 5.5 mm thick glass panes. (HSR 13.10.2).
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78).
Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade: (1) Two or more coats on new work. (HSR 11.82.1).
Finishing walls with Acrylic Smooth exterior paint of required shade : (1) New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). (HSR 11.95.1).
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. Size 300 mm x 16 mm (HSR 12.98.1)
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete For Size 200 mm x 10 mm (HSR 12.99.1)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. 125 mm x 150 mm x 35 mm. (HSR 12.102.1)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.1.1).
Profile E Fixing with adjustable lugs with split end tail to each jamb. (HSR 13.3.3.1).
Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 (HSR 10.8)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455 mm x 455 mm / 455 mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 21.84.1) (a) Size 450mm x450mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping
Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 1 O litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (HSR 22.34)
Providing and Fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (HSR 22.106.1) 15mm nominal bore. .
Providing and Fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (HSR 22.107.1) 15mm nominal bore.
Providing and Fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (HSR 22.108).
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps (HSR 22.1.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (HSR 22.85.1) 15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes (HSR 22.85.2)
25 mm nominal outer dia Pipes (HSR 22.85.3)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .