| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 3RD FLOOR KAY M PLAZA GANESHGURI G S ROAD GUWAHATI 06 | GUWAHATI | ASSAM | ₹1.7 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹1.9 Cr+₹26.5 L (15.8%)Rejected-AOC T 3 PARMESHWARI BLDG CHATRIBARI RD GUWAHATI ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | ₹1.9 Cr+₹26.5 L (15.8%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not-Qualified |
Tender Value
₹1.9 Cr
EMD Value
₹3.7 L
Closing Date
19 Oct 2021, 3:00 pmClosed
Addl. CE, PWD(Elect.), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
GROUP-B Construction of Mother and Child Hospital (500 bedded) at Gauhati Medical College and Hospital, Guwahati Under SOPD-ODS for the FY 2019-2020. (Providing 1600 KVA Transformer along with allied accessories etc.), GROUP-B
2021_PWBNH_23137_2
CE/BLD/ ELECT/15/2021/Pt-1/32 Dated 04/10/2021
Open Tender
Electrical Works
Item Rate
365 days
Guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹5,600
Assam State Road Board Maintenance (Road) Fund
₹3.7 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
7 Sept 2024
8 Oct 2021
19 Oct 2021
8 Oct 2021
19 Oct 2021
8 Oct 2021
11 Oct 2021
Amount
Supplying, Installation, Testing and Commissioning of Cast Resin Dry Type 1600 KVA, 33/0.433KV, 3 Phase, 50 Hz, Dyn11 vector group, copper wound, class F insulation associated with winding temperature indicator/controller actuated by means of resistance temperature detector embedded in LV windings, Indoor Type transformer with approximately 5% impedance, tappings for off load operation on HV side in step of +/- 2.5%, +5.0% to -7.5%, having cable end boxes on HV side suitable for 3C x 240 sq. mm XLPE cable of 11 KV grade and 2500A TPN Aluminium Bus Duct connection on LV side with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to HT breaker for safety tripping, suitably mounted on M.S. channel i/c supplying and grouting of suitable M.S. channel with all accessories and confirming to IS 11171:1985 & as per specification attached complete in all respects as required at site. Transformer Losses shall be as per latest ECBC Code-2017. 1600 KVA 33/0.433 KV. Dry transformer with off Circuit tap links
T N T Projects Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .