Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.9 Cr+₹2.3 L (1.23%)Rejected-Finance | ₹1.9 Cr+₹2.3 L (1.23%) | L2 | Rejected-Finance Higher rate to the Contractor |
| 3 | L3₹1.9 Cr+₹6.3 L (3.44%)Rejected-Finance | ₹1.9 Cr+₹6.3 L (3.44%) | L3 | Rejected-Finance Higher rate to the Contractor |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not responsive |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
23 Feb 2022, 5:00 pmClosed
Executive Engineer (OS)
CCS HAU, Hisar
Special repair renovation of building of College of Agriculture at Regional Research Station, Kaul. (including PH and EI works)
2022_HRY_207525_1
3280-C
Open Tender
Civil Works
Works
180 days
CCS HAU
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
₹3.5 L
Yes
4 May 2022
10 Feb 2022
24 Feb 2022
10 Feb 2022
23 Feb 2022
10 Feb 2022
Amount
Civil work 1 to 64:- Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge In cement mortar (HSR 5.7.4)
Demolishing cement concrete manually/ by mechanical means direction of Engineer - in - charge. Nominal concrete 1 :2:4 or leaner mix (i/c equivalent cum design mix) (HSR 5.23.2)
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area 3 sq. metres and below (HSR 5.30.1)
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead Of area beyond 3 sq. metres (HSR 5.30.2)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 sqm mm manually/ by mechanical means and disposal of material within standard lead as per direction of Engineer- in-charge. (HSR 5.42)
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead). (HSR 5.45)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
Centering and shuttering including strutting, propping etc. and removal of form for Shelves (Cast in situ) (HSR 6.30.4)
Lintels, beams, plinth beams, girders, bressumers and cantilevers (HSR 6.30.5)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Hard drawn steel wire fabric (HSR 6.34.5)
Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
Half brick masonry with common burnt clay non-modular bricks of class designation 7.5 in foundations and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.27.2)
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work (HSR 8.27.2)
Providing gola 75x75 mm in cement concrete 1: 2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase (HSR 9.17.1)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing periMeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and30 mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and periMeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of periMeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of painting with 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (HSR 9.46.1)
GI Metal Ceiling Lay in plain Tegular edge Global white colour tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. (HSR 9.47.1)
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, sqm Cat Eye or equivalent. (HSR 10.50.1 )
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (HSR 10.63.2)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (HSR 10.67.2)
Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm (HSR 10.70.2)
10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) (HSR 11.4.2)
12 mm cement plaster of mix : 1 :4 (1 cement: 4 fine sand) (HSR 11.5.3)
15 mm cement plaster on rough side of single or half brick wall of mix: 1 :6 (1 cement: 6 coarse sand) (HSR 11.9.2)
Pointing on brick work or brick flooring with cement mortar 1 :3 (1 cement : 3 fine sand): Raised and cut pointing (HSR 11.25.2)
Pointing on tile brick work with cement mortar 1 :3 (1 cement : 3 fine sand): Flush/ Ruled/ Struck or weathered pointing (HSR 11.26.1 )
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (HSR 11.60)
Distempering with 1st quality acrylic distemper (ready mixed) having voe content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work (HSR 11.65.1)
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works (HSR 11.68.3)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied@ 3.84 kg/10 sqm) (HSR 11.93.1)
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (HSR 11.95.1)
Kiln seasoned and chemically treated Hollock wood 35 mm thick (HSR 12.10.2.1)
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with sqm necessary screws (HSR 12.37.1)
25 mm thick (for cupboard) including ISi marked nickel plated bright finished M.S. piano hinges with necessary screws. (HSR 12.37.3)
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 90 mm (HSR 12.70.3)
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm (HSR 12.98.1)
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 300x10 mm (HSR 12.99.1)
250x10 mm (HSR 12.99.2)
200x10 mm (HSR 12.99.3)
Providing and fixing aluminium handles, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125 mm (HSR 12.102.1)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) (HSR 12.157.1.2)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately Powder coated aluminium (minimum thickness of powder coating 50 micron (HSR 12.157.2.2 )
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade I Type II, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides (HSR 12.158.2 )
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (HSR 12.159.2 )
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes (HSR 13.10.1)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (HSR 13.29.2)
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (HSR 30.21)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work (HSR 30.28.1)
Dismantling cement conglomerate / terrazzo floors 25 mm to 50 mm thick including concrete base. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in flooring including matching grains laid in any pattern as specified over base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Providing and fixing 15 mm to 18 mm thick Sardar Ali granite stone (polished) in skirting including matching grains laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade including rubbing and polishing, complete. (NS)
Scraping of brick tiles of size 22.86cm x 11.43cm x 3.81cm in cement mortar, complete in all respect as directed by Engineer-In-charge. (NS)
Collection of Ist class bricks, at the site of work including carriage, loading unloading and stacking, etc., confirming to Haryana PWD Specification No.3.5. (NS)
Providing and fixing 25 mm dia stainless steel curtain rods weighing 0.560 kg/meter with brackets & side covers (balls) of vista make, clamps, plastic gutties/rawl plugs etc., complete in all respects. (NS)
Supplying and fixing readymade white writing board of PRESKO make with delux frame or any other similar brand, fixed in position, including wooden gutties, nails and screws, etc., complete in all respects as per drawing and design. (NS)
Providing and fixing C.I. grating over 100 mm dia rain water pipe, fixed in position, complete in all respects. (NS)
Providing and fixing cabinet shutters made of 19 mm thick wood polymer composite (WPC) panel/board of Wood Trek, Vindya, Alstone or Strek make of 0.55 to 0.70g/m3 density of approved colour, i/c cost of iron hinges & screws, culting etc. complete in all respect as directed by Engineer-in-Charge
Providing and fixing wooden cabinet of size 4'-0'' long 4’-0” high and 1’-0” deep consisting of following:- i) 19 mm thick BWR grade-II black board for top, bottom sides and one horizontal and one vertical inner partition (ISI mark) finished outer & inner face with 1 mm thick plastic laminated sheet of approved shade & colour (ISI mark). ii) 6 mm thick BWR grade-II plywood on back side of wall cabinet. including cost of cutting, nails, screws etc, compelte in all respect as directed by Engineer-in-Charge.(NS)
Public health work 65 to 118:- Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) (HSR 6.1.2)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc.complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more (HSR 6.34.6)
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cement: 6 coarse sand) (HSR 7.22.2)
12 mm cement plaster of mix : 1 :6 (1 cement: 6 fine sand) (HSR 11.5.4)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (HSR 13.27)
Extra for fixing and jointing union couplings in G.I. and W.I. pipelines 32 mm internal diameter (HSR 20.23.4)
40 mm internal diameter (HSR 20.23.5)
Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required 11.43 cm thick wall (HSR 20.26.1)
22.86 cm thick wall (HSR 20.26.2)
Cutting holes up to 23 cm square for pipes in flooring and roofs of brick tiles with lime concrete and making good including, repointing, replastering and colour or white washing where required. 115 mm thickness of floor (HSR 20.27.2)
Fixing and jointing gun metal peet valves (heavy pattern) with hand wheels, on G.I. pipelines laid in the ground or inside buildings, including cartage from divisional stores or nearest railway station to site of works 32 mm internal diametre (HSR 20.31.4)
40 mm internal diametre (HSR 20.31.5)
Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. (HSR 20.36)
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (HSR 22.1.4)
Providing and fixing white vitreous chinaware laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 450x300x150 mm (HSR 22.6.1)
Size 600x450x200 mm (HSR 22.6.2)
Providing and fixing 15 mm C.P. brass Laboratory cock swan neck of best quality (to the approval of Engineer-in-charge). One way (HSR 22.8.1)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (HSR 22.15)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (HSR 22.22.1)
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1 )
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required. Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.3)
Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern (HSR 22.26.4)
Providing and fixing 8 mm dia C.P.S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing toilet paper holder C.P. brass (HSR 22.42.1)
Providing and fixing partitions for different type of urinals Vitreous Chinaware Partition plate Large size 835mm x 355 mm White (HSR 22.50.1.2.1)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal outer dia Pipes (HSR 22.85.5)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes (HSR 22.86.2)
25 mm nominal outer dia Pipes (HSR 22.86.3)
32 mm nominal outer dia Pipes (HSR 22.86.4)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (HSR 22.103.3)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore (HSR 22.108.1)
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181)
Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (HSR 22.209)
Providing and fixing in position best Indian make coat and hat hooks fixed into wall with C.P. brass screws and rawl plugs etc. complete including cutting and making good the walls etc. C.P Brass Two Way (HSR 22.212.1.2)
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B 110 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.2)
90 mm old SWR UPVC pipe lines laid complete (HSR 22.222.2.3)
Supply of CPVC Union couplings with brass internal fittings, complete in all respect. (NS) Make:- Prince/Supreme/Skipper/ For 32 mm nominal outer dia Pipes
For 40 mm nominal outer dia Pipes
Supply of CPVC control valve with brass internal fittings, complete in all respect. (NS) For 32 mm dia
For 40 mm dia
Supply and fixing of PVC floor traps (Heavy duty) of 90 mm o/dia outlet of Prince /Supreme/Skipper make, complete in all respect. (NS)
Supply and fixing of PVC gully traps (Heavy duty) of 100 mm dia size ( 4") with cover and frame of Prince/Supreme/skipper make complete in all respect. (NS)
Providing and fixing of UPVC specials of Prince / Supreme/Skipper make as per detail given below:- (NS) 110 mm o/d size (i) Elbow
(ii) Door tee/ junction
(iii) Cowls
90 mm o/d size (i) Elbow
(ii) Door tee/ junction
(iii) Cowls
Electrical work 119 to 126:- COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) (HSR 23.5.6.1)
MS CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of MS conduit pipe 1.6 mm thick , ISI marked surface/recessed in slab/wall/ceiling etc. including cost of MS bends, inspection box and all other material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. MS Pipe of 20 mm dia. (HSR 23.6.6.1)
MS pipe of 25 mm dia. (HSR 23.6.6.2)
PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS Supply and erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ceiling etc. including cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC Pipe of 20 mm dia. (HSR 23.7.6.1)
PVC pipe of 25 mm dia. (HSR 23.7.6.2)
S/E of Fittings and Accessories. Electric buzzer 220/230 volts A.C. Bakelite with double coil. Electric buzzer 220/230 volts A.C. Bakelite with double coil. (HSR 23.8.1.7)
Bakelite angle/straight button holder large size. (HSR 23.8.1.12)
Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. 1 & 2 Modules (HSR 23.8.10.1)
3 Modules (HSR 23.8.10.2)
4 Modules (HSR 23.8.10.3)
6 Modules (HSR 23.8.10.4)
8 Modules (HSR 23.8.10.5)
12 Modules (HSR 23.8.10.6)
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. (HSR 23.8.11.1) 5 amp 1 way switch
15 amp 1 way switch (HSR 23.8.11.3)
5 amp Socket (HSR 23.8.11.4)
15 amp 6 pin Socket (HSR 23.8.11.5)
Bell Push (HSR 23.8.11.6)
step type Fan Regulator 2 modules 300 watt (HSR 23.8.11.7)
Telephone Socket outlet modular type (HSR 23.8.11.8)
Blanking plate (HSR 23.8.11.10)
RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type (HSR 23.8.11.11)
MCCB ,DISTRIBUTION BOARDS, MCB’s, RCCB's, CHANGE OVER etc. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work TRIPLE POLE MCCB 16 to 100 Amp, 25 KA (HSR 23.22.1.3)
TRIPLE POLE MCCB 125 to 160 Amp, 25 KA (HSR 23.22.1.4)
TRIPLE POLE MCCB 200 to 250 Amp, 25 KA (HSR 23.22.1.5)
TRIPLE POLE MCCB 300 Amp, 25 KA (HSR 23.22.1.6)
TRIPLE POLE MCCB 400 Amp, 50 KA (HSR 23.22.1.7)
Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (HSR 23.22.4.4) SPN DB Double Door 16 way ( 2 incoming and 14 outgoing )
TPN DB Horizontal type Double Door 4 way ( 8 incoming 3 phase 4 outgoing ) (HSR 23.22.4.5)
Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- SP MCB 6-32 AMP (HSR 23.22.5.1)
SPN MCB 6-32 AMP (HSR 23.22.5.3)
TPN MCB 40-63 AMP (HSR 23.22.5.6)
S/E of blanking sheet in existing distribution board. (HSR 23.22.7)
SITC Four pole ONLOAD Manual change over switch in SS enclosureof followingRatings 100 amp 415 volts (HSR 23.22.8.2)
200 amp 415 volts (HSR 23.22.8.3)
300 amp 415 volts (HSR 23.22.8.4)
Supply and fixing Galvanised Iron flexible pipe complete with socket nipples and check nuts etc.at both ends (Upto length of one Meter):- Size 20 mm dia (HSR 23.23.1.2)
Size 25 mm dia (HSR 23.23.1.3)
Supply of GI pipe (B-Class) for suspension rod of ceiling fan including threading if required. 15 mm dia (HSR 23.23.2.1)
Providing and fixing fan hook made from 8 mm dia MS rod 75 cm longof required shape and size (HSR 23.23.4)
Supply and erection of MS cable tray , duly pained as requiredincluding erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR 23.23.6.1) MS perforated cable tray painted with powder coating 100X50x2 MM
Supply and erection of cable tray cover made of 1.25mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. (HSR 23.23.7.1) GI cable tray Cover, suitable for cable tray of 100X50X2 mm
Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channe l and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-incharge of the work. 2 pair telephonewire (HSR 23.23.8.1)
4 pair telephonewire (HSR 23.23.8.2)
Supplying and drawing of 1no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required (HSR 23.23.9)
DIMANTLING Dismantling of old wiring points (surface wiring system) including necessary repairs to wall etc. (HSR 23.25.1.1) Light, fan or call bell Point in cluding circuit / sub sub main wiring
wall socket Point in cluding circuit / sub sub main wiring (HSR 23.25.1.2)
MS STAND, BUS BAR CHAMBER AND PANELS Supply and erection of M.S.angle iron frame duly welded for housing M.S. sheet & main switches etc.on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. (HSR 23.24.1)
EARTHING AND LIGHTING ARRESTOR Earthing with G.I earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. as required. (HSR 24.1.1)
Extra for using salt and char coal/coke for pipe earth electrode as required. (HSR 24.1.2)
Earthing with G.I. earth plate 600mm x600 mmx 6 mm thick including accessories and provinding masonry enclosures with cover plate having locking arrrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. (HSR 24.1.3)
Earthing with tinned copper earth plate 600mm x600 mmx 3 mm thick including accessories and provinding masonry enclosures with cover plate having locking arrrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. (HSR 24.1.4)
Extra for charcoal or coke and salt for G.I. plate earth electrode. (HSR 24.1.5)
Supplyingandlaying25mmx3mmG.I.stripin40mmdia,GIpipeas/from earth electrode including soldering etc. asrequired.(HSR 24.1.7)
Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connectionsetc.asrequiredwithalllabourandmaterial. (HSR 24.1.8)
Providing and fixing 25mm x 5mm copper strip in 40mm dia G.I.pipe from earth electrode as required. (HSR 24.1.9)
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. (HSR 24.1.10)
Providing and laying earth connections from earth electrode with 4.00mm dia G.I. wire in 15mm dia G.I. pipe from earth electrode as required. (HSR 24.1.11)
Providing and fixing 4.00mm dia G1.Wire on surface or in recess for loop earthing as required. (HSR 24.1.13)
Supply and erection of suitable compression type brass cable glands for underground Cable :- 25 sqmm to 50 sqmm cable 2 to 4 core (HSR 24.2.7.3)
70 sqmm to 95 sqmm Cable 3 to 3½ Core (HSR 24.2.7.4)
120 sqmm to 185 sqmm Cable 3 to 3½ Core (HSR 24.2.7.5)
Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 25 sqmm (HSR 24.2.8.5)
50 sqmm (HSR 24.2.8.7)
70 sqmm (HSR 24.2.8.8)
95 sqmm (HSR 24.2.8.9)
185 sqmm (HSR 24.2.8.12)
S/E of mark double walled corrugated ( DWC) HDPE pipe 10 kg/sqcm, laid 0.75 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket/ cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect upto the entire satisfaction of Engineer incharge of the work. DWC/HDPE pipe 63/50 mm outer dia/inner dia (HSR 24.5.2.3)
DWC/HDPE pipe 90/75 mm outer dia/inner dia (HSR 24.5.2.4)
DWC/HDPE pipe 145/123 mm outer dia/ inner dia (HSR 24.5.2.6)
RUBBER MATTING Pdg. And fixing of insulated rubber mating suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge (HSR 20.84)
DG SETS Designing , Supply & erection of DG set of capacity given below with noise controlled devices acoustic of suitable rating, testing and commissioning of diesel generating set, radiator cooled, 3 phase, 4 wire, 50 cycles 415 +(-)1% volts AC alternator coupled directly through a set of flexible coupling on a common MS fabricated base frame with diesel engine complete with suitable size incoming cable from generator to change over/AMF panel , making 2nd incoming cable connection from transformer, outgoing cable connection from changeover/ standard panel, making second incoming cable connection from transformer , outgoing cable connection from changeover / STD panel to incomer of motor starter panel, fenced enclosure with platform for DG sets complete as per following detailed scope and specifications and directions of Engineer-in-charge . The rating should be at 1500 RPM. a) Diesel Engine b) Alternator c) Battery 24 V. d) Base Plate. e) suitable sq mm suitable core copper cable upto 40 Meters. f) Tools, standard panel g) Metering set 415 VAC-1 set (Amp. meter, Volt Meter, ASS, VSS, Phase Indicator, control fuse, frequency meter, CT's) h) Metering set 60/5A/110V (Amp. Meter, Volt Meter) i) Overload protection for DC-1 No. j) Battery Charger 24V DC k) Copper bus bar of suitable size I) KWH meter 96 sqmm size m) Starting fuse button and key switch9on/off) n) Indicating lamps for low lubricated oil pressure, high coolant temperature, set running , load on, De control and other required accessories complete in all respects to the satisfaction of Engineer-in-charge 160 KVA (HSR 20.89.8)
Supply installation testing and commissioning of wall free standing floor mounting dust & vermin proof compartmentalized cubical panel made out of 2 mm thick CRCA sheet required hardware 3 mm thick bakelite sheet providing all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of zinc/Red oxide primer followed by 2 coats of powder cating in grey or required shade after rinsing. the panle having PU/Neoprene rubber gasket of not less than 3 mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/ switch wear.Transparent arcylic sheet shall be provided in front of bus bar compartment to prevent direct access to bus bar bakelite sheet 3 mm thick for separately cable alley to BBC from switch chamber Extended solid copper bars up to cable alleys shall be provided for outgoing connection which shall be paid as extra tiems side walls and cable alley compartments shall be haiving bolted type doors with detachable extension type strcture. the panel will be complete with control wiring ( copper) and fuse protection ( only outer area on all sides shall be measured ) (NS)
Supply and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing go same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat srinkable PVC insulation complete in all respect. (NS)
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 1.5 sqmm.
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 04 sqmm.
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 06 sqmm.
S/E of PVC unsheathed FRLS copper conductor cable single core 1100 volt grade in existing pipe of suitable size excluding cost and erection of pipe. (NS) Size 10 sqmm.
S/E of 5 Star AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. i) 1200mm sweep. Make: Usha, Orient, Crompton (NS)
S/E of AC ceiling fan capacitor type complete with shackle, 300mm down rod etc. i) 1400mm sweep. Make: Usha, Orient, Crompton (NS)
S.I.T.C of push ON/OFF type 25 A Modular type motor starter swithch ( white color) fr AC'S including the cost of petty meterial required to complete the job upto entire satisfaction of Engineer-in Charge. (NS)
Supply of propeller type AC ventilating fan (exhaust fan) with necessary earthing arrangements of fan with shutter complete in all respects Size 380mm(15”) sweep (Heavy Duty) 1400 RPM Make: Orient, Usha, Khaitan, Crompton. (NS)
S/E of LED tube rod ≤20watt double side connections with 4 feet long housing made of CRCA sheet steel with epoxy powder coated white after phosphochromate treatment and 2 nos. lamps push fit type white polycarbonate holders and reflector made of white powder coated CRCA sheet total system lumen of 20watt LED should be ≥2200 in cool day light ( 5700K to 6500K ) PF > 0.95 , CRI >80 , Avg. life >50000 hours complete with mounting bracket and accessories as required with connections Make Philiphs , Havells , wipro , Bajaj ( NS )
S/E of recessed type 42 watt full window glare free opal difffuse LED panel of size 595x595 mm suitable for Armstrong/POP/GB ceiling with M.S. Powder coated white housing. Total system lumen of 42 watt LED should be 5100 or above in cool day light (5600k to 6500k), Power factor >0.95, CRI (Ra) >80, LED lamp efficiency ≥140 lm/w, Average life >50000hours, complete with all accessories. (Industrial) Make Havell's, Philips , Bajaj (NS)
Dismantling of old panel and return old material to store with in radius of 2 KM. (NS)
Dismantling of old DB,BDBs, SPN Box & TPN Box and return old material to store with in radius of 2 KM. (NS)
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- Size 4x25 sqmm (Armoured) (NS) Make: Havells, Finolex, L S Power, CCI
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- (NS) Size 4x50 sqmm (Armoured) Make: Havells, Finolex, L S Power, CCI
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- (NS) Size 3.5x95 sqmm (Armoured) Make: Havells, Finolex, L S Power, CCI
Supply & erection of under ground cable lose in existing pipe or trenches complete with necessary connecitons:- (NS) Size 3.5x185 sqmm (Armoured) Make: Havells, Finolex, L S Power, CCI
Supply & erection of under ground cable laid 1 mtr below ground level with sand and bricks including refilling of trench complete with necessary connecitons:- (NS) Size 3.5x95 sqmm (Armoured) Make: Havells, Finolex, L S Power, CCI
Supply & erection of under ground cable laid 1 mtr below ground level with sand and bricks including refilling of trench complete with necessary connecitons:- (NS) Size 3.5x185 sqmm (Armoured) Make: Havells, Finolex, L S Power, CCI
Pdg. and fixing of precast RCC (1:1½:3) cable route marker of size 01 mtr. Deep / 0.25 mtr. Width 0.15 mtr. Thick 0.25 mtr. Below top of side wall and proper embedded in wall. The writing words, L.T. cable on three sides of route markers including arrow on two sides with approvrd make of enamel paint of yellow colour including white colour Apex of approved make 6 nos. horizontal strips for tor steel bar 8 mm dia and 6 nos. vertical tor steel bar 12 mm dia as instruction and as entire satishfaction of the Engineer in Charge of the work. (NS)
SITC of AMF Panel for one no. 160 KVA DG set with all necessary accessories/ items to make connections and accommodate the AMF function. Complete with all Petty required to full fill the job upto the entire satisfaction of Engineer -in charge. (NS)
Providing and installing split type air conditioners, five star rating inverter type with copper coils 2.0 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (NS) (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1450 cum/ hr. (iii) Sound level (H/M/L)- 41/38/34/25(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (five star rating) Model as approved by the Engineer-in-Charge
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 Meters length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four Meters length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 Meters of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 15.88mm(5/8") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit.
Providing and installing split type air conditioners, four star rating inverter type with copper coils 1.5 ton capacity ± 10%) fitted with super tropical - DC PAM inverter- return cooled - rotary compressor operating on refrigerant R-32 suitable for wall mounting confirming to IS : 1391 (part-2)/92 (except power consumption norms) with upto date amendments, suitable for operating on 230 volts, 50 Hz single phase A.C. supply having following specifications:- (NS) (i) Cooling coil row -3 Nos. (ii) Air flow (CMH) -1000 cum/ hr. (iii) Sound level (H/M/L)- 45/38/26(silent mode) (iv) Louvers swing- 3D + 3D Auto etc. complete in all respect MAKE :- O General/Mitsubishi (Heavy Industries) (four star rating) Model as approved by the Engineer-in-Charge
Providing and fixing extra copper tubing/regrigerent pipe for above split air conditioners (if required) consisting of inlet, outlet pipes, insulation and electric wiring etc. as per requirement, complete in all respect beyond 4.0 Meters length. (NS) NOTES :- INSTALLATION OF AIR CONDITIONERS INCLUDES:- 1. Mounting/ fitting indoor and outdoor units at their respective locations 2. Providing & laying refrigerant pipe line of four Meters length and beyond (if required) and connecting both the units after drilling holes in the wall, if required. Thickness of the copper tubing shall not less than 0.80 mm. 3. Insulating the suction pipe with expanded polythene pipe tubing. 4. Providing & laying drain pipe to throughout the condensate water being formed in the indoor unit 5. Leak testing entire system 6. Charging refrigerant gas in the unit 7. Electric wiring ; suitable electric wiring and switch should be provided with in 4 Meters of the location of the units as per requirement 8. PVC channels for concealing the pipes etc. 9. Refrigerant piping thickness- 18 guage (1 mm) (i) Liquid line :- 6.35mm (1/4") (ii) Gas line:- 12.7 mm(½") 10. Providing and fixing 2.5 sqmm x 4 core coper wire sheathed for connections and communication between indore unit to outdoor unit.
Providing and installation of automatic voltage stabilizer of 5.00 KVA capacity(heavy duty ) copper wound 100 up voltage of V-Guard /ISI marked complete in all respect. (N.S.)
Providing and fixing in position powder coated MS stands for outdoor units including suitable nuts & bolts etc., of best quality complete in all respect (NS)
Providing and fixing UPVC pipes and specials of ¾ " dia size (15 mm i/dia ) for drainage of condensed water from air-conditioner to nearest disposal point, complete in all respect to the direction of the Engineer In-charge. Make:- Prince/Supreme/Skipper (NS)
Supply & fixing of rotary handle for on /off operation of existing MCCB in the LT panel including fixing the same in postion with all labour and material required to complete the job in all respect (NS) Rotary handle up to 125 Amp. MCCB
Supply & fixing of rotary handle for on /off operation of existing MCCB in the LT panel including fixing the same in postion with all labour and material required to complete the job in all respect (NS) Rotary handle above 125 Amp. MCCB
Pdg. & Fixing of CO2 type 4.5 kg High Pressure portable fire extinguisher, filled with CO2 Gas as per IS 15222, Control discharge ,mechanism fitted with 1 Meter wire Barbed Hose & Flat Horn with diffuse nozzle for dispressed discharge of CO2, applicable on Class B,C and electrically started fire, fire rating 21B, External coating is of enamel spray painting, Valve Confirm to IS 3224 ISI Marked, CO2 cylender constructin : hot spinning by seamless pipes & bearing ISI mark, Body Confirms to IS 7285 and PESO Approved, Extinguishers confirmed to IS 15683 : 2006 and ISI marked. (NS) Make: SPAGO/SAFEGUARD/MINIMEX
Supply & Erection of 300 mm Sweep wall mounting fan with pull cord control for speed and oscillation including the cost of all petty material required to complet the job upto entire satisfaction of Engineer-in-Charge (NS) Make: Havells, Usha, Orient, Crompton
S/E of PVC pipe of 6 kg. pressure, laid 1 Meter below ground level including digging and refilling of the trech completing with joining with jute and cement etc. (NS) PVC PIPE SIZE 120 MM DIA.
S/E of PVC pipe of 6 kg. pressure, laid 1 Meter below ground level including digging and refilling of the trech completing with joining with jute and cement etc. (NS) PVC PIPE SIZE 65 MM DIA.
the creative infra and interiors pvt. ltd.
YASHRISHI ENGINEERING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .