Garrison Engineer St Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
SOIL INVESTIGATION FOR PROVN OF TRANSIT ACCN AND COMMUNITY HALL CUM RECREATION CENTRE AT DAD RESIDENTIAL COMPLEX NANDAMBAKKAM CHENNAI
2021_MES_488153_1
3120-SOIL INVESTIGATION FOR PROVN OF TRANSIT ACCN
Open Tender
Job Works
Item Rate
30 days
St Thomas Mount
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
7 Dec 2021
13 Nov 2021
7 Dec 2021
13 Nov 2021
4 Dec 2021
17 Nov 2021
13 Nov 2021 - 16 Nov 2021
Amount
SOIL INVESTIGATION PROVN OF TRANSIT ACCN AND COMMUNITY HALL CUM RECREATION CENTRE AT DAD RESIDENTIAL COMPLEX NANDAMBAKKAM CHENNAI(ESTIMATED COST Rs.80000.00)
Mobilisation of Mechanical drilling equipment / rig and shifting of entire arrange ment from one bore to another bore hole location and setting of boring/drilling rig as required/directed by Engineer-in-charge (LS)
Boring 150mm dia bore hole to 10 mtr through the following type of strata for Mechanical Laundry. 02 Nos (LS) Note: Depth of bore holes may be taken 10m (minimum N value reaches 50), in any type of soil/soft disintegrated rock/hard rock for isolated /combined / raft foundation. To ensure that boulders or layers of cementeous soil is not mistaken for bed rock, core drilling to be done to a depth of atleast 1.0m in bed rock in areas where boulders are found & collection/ preparation of rock samples and determination of bulk density, water absorption and compressive strength is done. However the maximum depth of bore hole is 10m in any case.
Collection of undisturbed soil sample at 1.5m intervals or at any change in strata in 150mm bore thin walled tube including waxing, sealing, packing and transporting to the lab.
Carrying out Standard Penetration test(SPT) including collection of disturbed soil samples in bore holes at every 1.5m depth or any change in strata and submit the report with all requisite data.
Conducting necessary tests as per relevant IS codes :-1892/NBC 2005/SP36 on all collected samples which include the determination of:- (Each bore hole ) (a) Atterberg limits- Liquid limit, Plastic limit , Shrinkage limit (b) Wet and dry density, degree of saturation of soil. (c) Unit weight(Bulk density), Natural Moisture content, Plasticity index, Specific gravity (d) Grain size analysis, Identification and classification of soil, Soil particle size distribution using sieve/hydrometer analysis (e) Shear parameter (C-ø Analysis), Tri-axial shear test and C-ø determination. (f) Consolidation test and permeability test (g) Specific gravity test for sand/rock (h) Crushing strength, Degree of weathering(CR value) and RQD of rock samples (j) Permeability test (k) Chemical analysis of ground water sample (min 02samples) (water to be obtained from the bottom of bore hole) (l) Free swelling Index and Swelling pressure if expansive soil is encountered. (m) Depth of water table below Ground level (maximum and minimum) (n) Presence of loose soil if any and its depth (o) If weak soil with lesser N value as specified in Table-I of IS 1893(Part-I):2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (p) Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation. (q) Recommendation for filling under floors and filling under protection including plinth protection.
(r) SBC and its calculation based on N value, shear strength and settlement creteria should be worked out for following footings size: 1.5 x 1.5m, 1.5 x 2.5m, 2.0 x 2.5m & 2.0 x 3.0m
Trial Pit of size 1.2m x 1.2mx 2.0m at various locations as directed by Engr-in-Charge - 01 No (LS) i) Atterberg limits ii) Natural moisture content iii) Wet and dry density iv) Particle size (soil grain size) v) Triaxial shear test or Direct shear test vi) Specific gravity vii) Free swelling test
Submission of report in four sets giving site plan showing the test points, sub soil profile, results of field investigations, laboratory test results, calculation of SBC, Comprehensive type of foundation (LS-01). Note: Soil Investigation and report shall be as per NBC, IS 1882, 2131, 2132,1888, 2720, 1904, 6403, 8009, 1498, 4968 and SP 36 in general
Note: The bidder shall be quote alongwith inclusive of all taxes (including GST)
JOSMAR CONSULTING ENGINEERS
Ashhirwaad Analytical Laboratory
SAKTHI DEVELOPMENTS COY
J Geotech
DECCAN ENGINEERS INDIA
Poongodi Constructions
stage.html
html • 0.03 MB
finance_544821.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .