Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
17 Nov 2023, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SO-I(Wks)
SO-I(Wks) ARTC and School Shokhuvi
Additional/alteration incl repair/maint incl replacement of internal and external services under for ARTC S at Shokhuvi
2023_ARMHA_779552_1
28028/ARTCS/Engr/NIT/23-24/39
Open Tender
Civil Works
Works
365 days
Shokhuvi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Commandant, ARTC and School
₹81,000
23 Jan 2024
4 Nov 2023
18 Nov 2023
5 Nov 2023
17 Nov 2023
5 Nov 2023
5 Nov 2023 - 16 Nov 2023
M/L for submain wiring, wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC casing/caping as required on replacement of 1.5sqmm size (2x1.5sqmm +1x1.5 sqmm earth wire.) Make : Havells/finoilex/KEI/Prestoplast)
ditto but 2x4 sqmm + 1x 4 sqmm as earth wire
ditto but 2x6 sqmm + 1x 6 sqmm as earth wire
M/L for painting of ceiling fan in installed position with one or more coats of spray painting with sysnthetic enamel paint of approved board and manufacture to give an even shade, including cleaning of surface with detergent etc as required and numbering etc asrequired.
Supplying and fixing 5 amps switch socket on the existing board including connections but excluding modular plate etc as required (on replacement)
Supplying and fixing 15 amps switch socket on the existing board including connections but excluding modular plate etc as required (on replacement)
Supplying and fixing stepped type electronic fan regulator on the plate switch box including connections but excluding modular plate etc as required (On replacement)
Supplying and fixing batten/angle holder including connection etc as required.
Supplying and fixing following rating, double pole, (Single phase and neutral) 240 volts, residual current circuit breaket (RCCB)/ELCB, having a sensitivity current upto 300 miliamperes in the existing MCB DB complete.
Instllation, testing and commisioning of pre wired , LED fitting of 18/20 watt complete with all accessories directly on ceiling /wall including connections with 1.5 sqmm FRLS PVC insulated, copper conductor, single core cable and earthing etc as required.
Supplyingand fixing call bell/buzzer suitable for singlephase 230 V, complete as required.
Supplying and fixing fan capacitor of 2.5 mfd of approved quality (Make : Havelles/USHA/Cromptor)
Rewinding the ceiling fan motor of 1200/14mm sweep, with enamelled copper wire of approppriate guage in replacement of insulating material such as laminated elytroid paper, sleeves, necewssary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing , replacement of missing /worne out nuts/bolts/washers, quater pins etc and testing after reassembling the same complete all as specified and directed by Engineer-in-charge.
Replacement of bearing No- 6201,6202,6203) ball bearing for 1200/1400 sweep ceiling fan of any model complete all as specified and directed Make : NBC/SKF/HRC.
Supply and fixing following modular switch/socket on the existing modular plate & switch boxincluding connections but excluding modular plate etc as required as per sample/make of 5/6 A switch.
Supplying and fix 3 pin 5/6 A socket outlet of approved quality as per sample,modular type of required make as approved by engr-in-charge.
Supplying and fixing following capacity TPN disconnector fuse switch unit inside the existing panel board with ISI marked of 63 Amps Capacity. Make : Havells/L&T
Supplying and fixing 63 amps rating 230/415 volts, 10 amps "C" curve miniature breaker suitable form inductive load of following polesw inexisting MCB DB complete with connections, testing and commissioning etc as required triple pole and neutral of 63 Amps capacity.
Supplyingand fixfing 4 pole Moulded case circuit breaker 100 Amps , 415 volts 50 Hz with rupturing capacity 25 KA. Make : Havells/L&T/Seimen/Schiender.
Supplyingand fixfing 4 pole Moulded case circuit breaker 125 Amps , 415 volts 50 Hz with rupturing capacity 35 KA. Make : Havells/L&T/Seimen/Schiender.
Supplyingand fixfing 4 pole Moulded case circuit breaker 200 Amps , 415 volts 50 Hz with rupturing capacity 35 KA. Make : Havells/L&T/Seimen/Schiender.
Supplyingand fixfing 4 pole Moulded case circuit breaker 250 Amps , 415 volts 50 Hz with rupturing capacity 35 KA. Make : Havells/L&T/Seimen/Schiender.
Supplyingand fixfing 4 pole Moulded case circuit breaker 400 Amps , 415 volts 50 Hz with rupturing capacity 35 KA. Make : Havells/L&T/Seimen/Schiender.
Supply and fix HT 11 KV, outdoor type gang operated air break switch suitable for horizontal or vertical mounting fixed tupe complete with 9 insulators of rating upto 400 amps complete.
Supplying only 25mm dia ISI marked PVC conduit/PVC casing/caping of approved quality (Make : Richa /presto plast/finolex
Supply only 25mm dia PVC bends suitable for conduit/casing/caping.
Supply only 3 mm thick phenolic laminated sheet 3 mm thick of approved quality of size 8x10 inches size
Supply MS nails of assorted size.
Supply only PVC flexible hose pipe of approved brand of 25mm-32 mm dia
Supply only GI unior 15mm nomical bore
Supply only GI unior 25mm nomical bore
Supply only GI unior 40mm nomical bore
Supply only GI unior 50mm nomical bore
Supply unplastesised PVC connection pipe with brass union 45cm long 15mm bore
Supply only bolts and nuts 16mm dia 60mm long
Providing and fixing chlorinated polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, includig all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.m spacing complete . This include jointing of pipes and fittings with one step CPVC solvant cement and testing of joints complte as per directed of engr-in-chargge 25mm nominal bore as outer dia of pipe. Make : Finolex/ or as approved brand.
ditto but 20mm nominal dia of pipes
Providing and fixing ball valve (brass) of approved quality, high , low pressure with plastic floats complete of 15mmdia
Providing and fixing ball valve (brass) of approved quality, high , low pressure with plastic floats complete of 20mmdia
Providing and fixing ball valve (brass) of approved quality, high , low pressure with plastic floats complete of 25mmdia
Supplying and fixing CI double acting air valve of approved quality with nuts, bolts, rubber insertions etc complete of 100 mm dia.
Providing and fixing mixture CP brass angle valve for basin mixture and geyser points of approved quality conforming to ISI8931 of 15mm dia.
Supply only rubber gaskets of approved quality.
Supply and filling transformer oil of approvede quality as per IS Specification . Make Savita
Supply and fix PVC board of size 8x10 inches size
Supply and fix PVC board of size 6x8 inches size
Supply only gland packing of size 8/10 size of approved quality.
Earthing of machinery/equipment installed at power house/sustation 25x3mm copper strip and copper plate of size 300x300x3mm, as earth electrode.
Providing and fixing 25mmx5mm copper strip on surface or in recess for connections etc as required.
Supplying and fixing following rating, four pole, 415 v, isolator in the existing MCB DB complete with connections, testing and commisioning etc as required of 40 Amps capacity.
M/s Kuhoi Zhimo
M/S SWETA ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .