Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NOT FOUND | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Rejected-Technical H NO 28 KAMAL PURA CHERHAR CHERHAR POOCHAL KISHTWAR KISHTWAR JAMMU KASHMIR 182204 | KISHTWAR | JAMMU AND KASHMIR | 182204 | Rejected-Technical Techno Commercially Disqualified |
Tender Value
₹24.1 L
EMD Value
₹49,000
Closing Date
16 Aug 2024, 6:00 pmClosed
GSM (CnP)
Group Sr. Manager (CnP), Pakal Dul HE Project, CVPP, Chenab Nagar-II, Kishtwar, JnK.
Renovation of Internal Electrical wiring of A-type, B-type and C-1 type quarters under the possession of Pakal Dul H.E Project, CVPPPL, Kishtwar, JnK
2024_CVPP_818458_1
CVPPPL/PDHEP/CnP/NIT-301/2024/ 445 Date-26.07.2024
Open Tender
Electrical Works
Works
120 days
PDHEP, CVPPPL
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
PDHEP, CVPP(P) Ltd
₹49,000
Yes
15 Jan 2025
26 Jul 2024
20 Aug 2024
26 Jul 2024
16 Aug 2024
26 Jul 2024
Amount
Wiring for light point/fan point/exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A points
Wiring for light point/fan point/exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-B points
Wiring for light/power plug with 2X4 Sq.mm FRLS PVC insulated, Copper Conductor, single core cable in surface/recessed medium class PVC conduit along-with 1 no. 4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit /Sub main wiring along with earth wire with following size of FRLS PVC insulated Copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5sq.mm.+ 1x2.5 Sq mm earth wire
Wiring for circuit /Sub main wiring along with earth wire with following size of FRLS PVC insulated Copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x10 sq.mm + 1x 6 Sq mm earth wire
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp Switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp Socket outlet
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amp Switch
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
Supply and fixing of 5 amp to 32 amp rating, 240/415V,10KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (10 amps)
Supply and fixing of 5 amp to 32 amp rating, 240/415V,10KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (16 amps)
Supply and fixing of 5 amp to 32 amp rating, 240/415V,10KA "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (32 amps)
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 A
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way double door
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing 3 pin 5A ceiling rose on the existing junction box/wooden block including connection as required.
Supply of 4 feet complete tube light fitting including all accessories LED type (20 Watt)
Supply of 1 feet complete tube light fitting including all accessories LED type (5 Watt)
Installation, testing and commissioning of pre-wired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100 mm x 75 mm)
Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
GANAI CONSTRUCTION AND SERVICES PRIVATE LIMTED (BID ID -3070017)
Tanveer Ahmed (BID ID -3070099)
JP Infratech (BID ID -3071045)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .