Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LAdmitted-Finance | -37.00% | ₹1.2 L | L1 | Admitted-Finance |
| 2 | L2₹1.4 LAdmitted-Finance | -31.00% | ₹1.4 L | L2 | Admitted-Finance |
| 3 | L3₹1.4 LAdmitted-Finance | -27.99% | ₹1.4 L | L3 | Admitted-Finance |
| 4 | L4₹1.7 LAdmitted-Finance | -16.05% | ₹1.7 L | L4 | Admitted-Finance |
| 5 | L5₹1.7 LAdmitted-Finance | -14.86% | ₹1.7 L | L5 | Admitted-Finance |
Tender Value
₹2.0 L
EMD Value
₹3,940
Closing Date
25 Apr 2026, 4:00 pmClosed
Ex. Engineer, Div. No. 01 JMC Dogra Hall, Jammu
Ex. Engineer, Div. No. 01 JMC Dogra Hall, Jammu
Construction of Soakage Pit and laying of PVC Pipe connect to Sewer Line near Govt. Women College, Parade, Jammu Ward No. 10. (Own Source 2025-26). (2nd Call)
2026_HAUDD_308113_2
Division No. 1/JMC/26-27/ Fresh e-NIT No. 06
Open Tender
Civil Works
Ward No. 10.
Please refer Tender documents.
2 documents required · 2 mandatory
₹600
Yes
Ex. Engineer, Div. No. 01 JMC Dogra Hall, Jammu
₹3,940
Yes
29 Apr 2026
18 Apr 2026
27 Apr 2026
18 Apr 2026
25 Apr 2026
18 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil : | - | cum | - | - |
| 2 | Providing and laying in position cement concrete of specified grade including curing but
excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) | - | cum | - | - |
| 3 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement lime mortar 1:1:6 ( 1 cement : 1 lime putty : 6 coarse sand) | - | cum | - | - |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with
5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) | - | cum | - | - |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in
position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. | - | Kg | - | - |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. | - | sqm | - | - |
| 7 | Cutting road and making good the same including supply of extra quantities of material i.e. crushed aggregate, moorum screening, red bajri and labour required.
16.14.1 Bituminous portion | - | cum | - | - |
| 8 | Providing and laying in position cement concrete of specified grade including curing but
excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) | - | cum | - | - |
| 9 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line- | - | no | - | - |
| 10 | Chequerred terrazzo tiles 22mm thick with graded marble chips of size upto 6mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, polishing and
curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Medium shade using 50% white cement and 50% ordinary cement. | - | sqm | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
BOQ_998868.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid