Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹21.4 L+₹1.9 L (9.80%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹23.6 L+₹4.1 L (21.0%)Rejected-Finance C O M KHARKARANG LUMJINGSUK BLOCK A MADANRTING SHILLONG 793021 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793021 | L3 | Rejected-Finance Being L3 |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
20 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Priyanka Tak GE I AF Shillong
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
REPAIR OR MAINTENANCE OR REPLACEMENT OF UG LT
2023_MES_630217_2
8068/23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE I AF SHILLONG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE I AF SHILLONG
₹47,000
Yes
7 Feb 2024
5 Jan 2024
22 Jan 2024
5 Jan 2024
20 Jan 2024
5 Jan 2024
Amount
Disconnecting of incoming, outgoing cables and earthing lead and taking down carefully existing unserviceable LT Feeder Pillar-Box/Panel/Busbar Enclosure with all accessories, including removing unserviceable cubicle with accessories from site, complete all as directed.
Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 25 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge. Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked) Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately
Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 16 Sqmm 4 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge. Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked) Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately
Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 240 Sqmm 3.5 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge. Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked) Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately
Supply and laying, connecting, testing, commissioning LT UG cable XLPE Insulated,armoured, electric power cables (heavy duty) 1100 Volts grade conforming to IS 7098 with aluminium conductor multi-strand of cross-sectional area 95 Sqmm 3.5 Core laid in trenches / ducts/ inside protection pipe including cable glands, lugs and suitable size of MS saddle clips etc. also taking out existing unserviceable UG cables all as directed by Engr-In-Charge. Make: Polycab(ISI Marked)/ Finolex(ISI Marked)/ Havells (ISI Marked)/ KEI (ISI Marked)/ Gloster (ISI Marked) Note:-(a) Excavation, sand cushioning, bricks shall be measured and paid separately
Material and labour for excavating in trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed.
Returning filling in soft/loose soil, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. NOTE : The top of filled trench shall be made proud by using the excavated soil to cater for subsequent settlement of soil.
Removing excavated materials (soils) not exc 50.00mtr and depositing where directed at a level not exc 1.50 mtr above the starting point in soil, complete all as specified and as directed.
Supply and filling for dry sand in cable protection trenches before and after the cables are laid, for sand cushioning to cables complete all as specified and directed. NOTE : thickness after punning of sand shall be (minimum as specified in SSR) measured and paid in this item.
Labour for boring under road, manually suitable for inserting 50 mm bore pipe at a depth 0.5 mtr to 1.0 mtr complete all as directed by Engineer-In-Charge.
Material and labour for brick protection for UG XLPE cable with burnt clay old size sub class 'B' bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge. Make: Best quality locally available which is duly approved by GE.
Relaying of bricks laid dry and flat abutting each other with gaps between adjacent brick not more than 10 mm and width equal to length of brick in trenches across the cable complete all as directed by Engineer-In-Charge. Note: Old good quality bricks shall be used which was obtained during taking out unserviceable UG cables.
Material and labour for cutting the road/hard standing and making good disturbed surface by using PCC type C2 (1:3:6) by using 40 mm graded crushed stone aggregate for the fixing the pipe complete all as directed by the Engr-in-Charge at site.
Material and labour for tubes "light grade" galvanised with all fittings laid in trenches of 50 mm bore dia including taking out old unserviceable GI/ HDPE/ polythelyne flexible pipes of any description all as directed by Engineer-In-Charge. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd
Material and labour for tubes "light grade" galvanised with all fittings laid in trenches of 100 mm bore dia including taking out old unserviceable GI/ HDPE/ polythelyne flexible pipes of any description all as directed by Engineer-In-Charge. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd
Material and labour for repairing LT panels/ LT feeder pillar box (Bus-bar system) with dismantling of bus-bar strips 4 Nos from insulators & disconnect/removing all incoming/outgoing cables/wires connections from bus-bar, change over etc, welding of sheet metal enclosure as required. Dressing/cleaning of bus-bar strips for removing sulphating, carbonisation, scales, dirt etc. Thoroughly, re-mounting on insulators rigidly, wrapping up of PVC insulation tape entirely over the bus-bar strips maintaining red, yellow, blue for phase & black for neutral. Dressing up of all incoming/outgoing cables/wires with replacement of aluminium cable lugs nuts/bolts properly crimpling/socket ting, re-fixing the cable glands (duly dressing of cable armoured) for all incoming/outgoing cables, change over etc. all as directed & specified by the Engr-in-Charge of following sizes:-
1200mm x 1500mm x 500mm
1200mm x 900mm x 500mm / 1000mm x 800mm x 500mm
Supply and fix as in replacement following components/parts in existing LT panel boards complete all as directed:-
MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts, Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links . Make :- Siemens / Legrand / Schneider/ ABB
MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts, Ics = 100% Icu, Lcu = 16 KA breaking capacity, rating 125 Amps including all fixing accessories with both ends spreader links . Make :- Siemens / Legrand / Schneider/ ABB
Digital type Frequency meter CI 0.2, 3 Phase, 4 digit, high resolution LED type. Make :- ABB / Legrand / Schneider/Siemens
LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC (set of three) Make :- ABB / Legrand / Schneider/Siemens.
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 240 to 300 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge. Make: M-Seal/ Cab-Seal/ Denson/3M
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 150 to 185 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge. Make: M-Seal/ Cab-Seal/ Denson/3M
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 70 to 120 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge. Make: M-Seal/ Cab-Seal/ Denson/3M
Supply and fix cable jointing kit for 1.1 KV grade cable for end joint complete with jointing materials heat shrink type and accessories suitable for 3.5/4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 sqmm, indoor/ outdoor type complete all as directed by Engineer-In-Charge. Make: M-Seal/ Cab-Seal/ Denson/3M
Supply, installation, testing & commissioning CPRI approved outdoor cubical type LT feeder pillar box suitable for 415V, 3 phase , 4 wire 50 Hz, AC supply system fabricated outer shell from MS sheet 3.15 mm thick and MS angle of size 50 mm x50 mm x6 mm frame front and back openable single door system lockable /openable by keys from both sides having lock system totally enclsoed dust, weather & vermin proof having and inner shell 2mm thick made of MS sheet compartmentlised for each control gear front openable single door system lockable/openable by keys having louvers and air vent gaskets for natural flow of Air. 'U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incommer/outgoing MCCBs and TPN copper busbars of rating 1.5 times that of controlling MCCB. TPN busbar and extension link shall be insulated with color coded heat shrinkable sleeve and shall be mounted on suitable size SMC insulator at suitable inteval throghout the length of TPN busbar. supported on SMC insulator, bottom base channel of MS section not less than 100mm x50mm x5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size of copper bus bars. All control wiring with minimum 1.5 sqmm PVC insulated multistranded copper conductor cable, cable alleys, cable gland, plates in two half and general construction confirming to IS:8623/93. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided on the busbar chamber and front of outer shell and The degree of protection of outer shell shall be IP-54 and mounted on suitable PCC foundation. A detechable pre drilled gland plate of thickness 3mm should be used at bottom shell. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillat box safely shall be made. Indicating lamps LED type, 230volts, AC at the incomer of the unit to show three phase availability at the outgoing of incomer including tamper proof digital meter to measure voltage, current with CT & PT (Make- Secure/L&T/HPL/Schneider). An inspection lamp with 5 watt LED bulb shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 & including carry the following controls :- Note: Contractor shall be submit feeder pillar box drawing before placing order and approved from GE.
INCOMING (a) MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts, Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 250 Amps including all fixing accessories with both ends spreader links - 01 No. Make :- Siemens / Legrand / Schneider/ ABB
(b) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three) Make :- ABB / Legrand / Schneider/Siemens.
(g) Supply and fixing changeover switch C-line type 250 Amps open execution type ,415 volt,50 cycles complete with operation handle. Make :- ABB / Legrand / Schneider/Siemens
OUTGOING (a) Aluminium bus bar of suitable rating-04 Sets
Supply, installation, testing & commissioning CPRI approved outdoor cubical type LT feeder pillar box suitable for 415V, 3 phase , 4 wire 50 Hz, AC supply system fabricated outer shell from MS sheet 3.15 mm thick and MS angle of size 50 mm x50 mm x6 mm frame front and back openable single door system lockable /openable by keys from both sides having lock system totally enclsoed dust, weather & vermin proof having and inner shell 2mm thick made of MS sheet compartmentlised for each control gear front openable single door system lockable/openable by keys having louvers and air vent gaskets for natural flow of Air. 'U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incommer/outgoing MCCBs and TPN copper busbars of rating 1.5 times that of controlling MCCB. TPN busbar and extension link shall be insulated with color coded heat shrinkable sleeve and shall be mounted on suitable size SMC insulator at suitable inteval throghout the length of TPN busbar. supported on SMC insulator, bottom base channel of MS section not less than 100mm x50mm x5mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size of copper bus bars. All control wiring with minimum 1.5 sqmm PVC insulated multistranded copper conductor cable, cable alleys, cable gland, plates in two half and general construction confirming to IS:8623/93. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided on the busbar chamber and front of outer shell and The degree of protection of outer shell shall be IP-54 and mounted on suitable PCC foundation. A detechable pre drilled gland plate of thickness 3mm should be used at bottom shell. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the feeder pillat box safely shall be made. Indicating lamps LED type, 230volts, AC at the incomer of the unit to show three phase availability at the outgoing of incomer including tamper proof digital meter to measure voltage, current with CT & PT (Make- Secure/L&T/HPL/Schneider). An inspection lamp with 5 watt LED bulb shall be fitted on top side of inner shell. The degree of protection for inner shell shall be IP-42 & including carry the following controls :- Note: Contractor shall be submit feeder pillar box drawing before placing order and approved from GE.
INCOMING (a) MCCB, adjustable type thermal magnetic release type,4 poles, 415 Volts, Ics = 100% Icu, Lcu = 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader links - 01 No. Make :- Siemens / Legrand / Schneider/ ABB
(b) LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts,AC -01 set (set of three) Make :- ABB / Legrand / Schneider/Siemens.
OUTGOING (a) Aluminium bus bar of suitable rating-04 Sets
Supply and fix as in replacement onload change over switch of current rating 400 Amps, 4 pole, 415 Volts with sheet metal enclosure, fixed-in-repairs, including taking down old unserviceable one, complete all as specified and as directed. Make: ABB/ Siemens/ Schneider/ Legrand/ Hagger/ L&T/ GE
Material and labour for digging of old chemical earthing pit (as directed by OEM/Engr-in-Charge) upto a level of 1.5 Mtr and filling of BARON Back filling compound(conductolite) or equiv chemical compound for improving the earthing result and testing after jointing in test terinal as specified and refilling / making good the disturbed earth pit as specified and directed .
Supply only chemical i.e. ground enhancing compound (GEC) in bag of 25 Kg BARON Back Fill Compound (Conductolite) each complete all as specified and directed.
Material and labour for adding salt in the ratio of 1:3 (as directed by Engr-in-charge minimum salt 8 kg) to each conventional earth pit and repairing the damaged earth pit cover after excavating the surface if required and making good,connecting it to earth test point.measuring the value and fixing funnel in repair as directed by Engr-in-Charge.
Material and labour for digging and filling in existing earthpits by charcoal and common commercial salt in alternate layer around the earth plate electrode in addition to existing(Charcoal 50 Kg & salt 25 Kg minimum) all as shown IN electrical plats No. 3 on page 497 of SSR Part-I and repairing the damaged earth pit cover after excavating the surface if required and making good,connecting it to earth test point.measuring the value and fixing funnel in repair as directed by Engr-in-Charge.
Supply and filling in existing earthpits by magnesium sulphate powder around the earth electrode complete all as directed.
Taking out old unserviceable galvanised iron earth strip and Material and labour for Earth continuity conductor of 32 mm x6mm galvanised iron earth strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as directed.
Taking out old unserviceable copper earth strip and Material and labour for Earth continuity conductor of 20 mm x3 mm copper strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, complete all as directed.
Material and labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required earthing galvanised wire 4.00 MM
Material and labour for earthing complete with galvanised steel earth plate electrode 60 cm × 60 cm.× 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip of size 32 mm x 6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified.
Taking out old unserviceable LDPE pipes and Supply and fixing low density polythelene pipes (LDPE) 40mm dia for insulation of earth strip from building at entry points complete all as directed.
Taking out old unserviceable 20mm bore GI watering pipe of earthing and Supply and fix 20mm bore Galvanised steel tubing medium grade as watering pipe of earthing etc conforming to IS-1239 complete all as directed. Make : Tata / Jindal Steel / Prakash/ Surya Roshni ltd
Taking out old unserviceable porcelain ceramic insulator and Supply and fixing white porcelain ceramic insulator with nut, bolt and washers for fixing earthing strip on wall/ceiling/roof all as directed. Make: BHEL/ Jaypuriya Brothers/ Pactil/ Southern Insulators
Material and labour for preparation of external and internal old painted steel surfaces of LT Panel boards/LT feeder pillar boxes/Bus Bar Chambers etc in position by removing/scrapping old disintegrated and deteriorated paint and painting two coats of synthetic enamel paint by spray gun over a coat of red oxide zinc chromer primer including writing letter complete all as specified and directed.
Material and labour for plain Cement Concrete type C2 (1:3:6) using 40 mm graded aggregate) in Foundation, Filling and Mass Concrete, complete all as specified and as directed.
Material and labour for for Glow sign board made with MS frame 3.5X1.2 Mtr X 0.45 Mtr and polycarbonate sheet internally provided with 04 LED FTL internally wired housed on gate pillars with GI pipe legs and connected with junction box,back side opening for changing of LED tubelight with MES logo on flex board in blue colour with thickness 1.5 MM minimum written the name of installation further as directed incl the rate for taking down old U/S by Engr-in-Charge.
M/S DEEDAR ENTERPRISE
Bhuiya Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .