Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹55.4 L+₹5.0 L (9.85%)Rejected-AOC 03 PATEL STREET GANDHI NAGAR AVADI TIRUVALLUR TAMIL NADU 600054 | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹58.1 L+₹7.6 L (15.1%)Rejected-AOC NO 51 TOWN HALL 3RD STREET ARAKKONAM TAMIL NADU 631 001 | ARAKKONAM | RANIPET | TAMIL NADU | 631001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹58.3 L+₹7.9 L (15.6%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹58.6 L+₹8.2 L (16.2%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
26 Nov 2020, 6:00 pmClosed
GARRISON ENGINEER M
GARRISON ENGINEER M NAVAL AIR STATION ARAKKONAM - 631006
REPAIR/ REPLACEMENT TO STREET/ SECURITY LIGHTS SOLAR LIGTS AND DISPERSAL LIGTS, STREET LIGHT CONTROL PANELS INCLUDING ALLIED ITEMS AND RENEWAL WORKS TO UNSERVICEABLE LT UG CABLES, LT PANEL ETC AT ARAKKONAM
2020_MES_392674_1
8944 OF 2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
ARAKKONAM
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE M NAS ARAKKONAM
₹98,000
Yes
15 Dec 2020
5 Nov 2020
28 Nov 2020
5 Nov 2020
26 Nov 2020
19 Nov 2020
Amount
Dismantling and taking out following size cable from existing feeder pillar/ LT panel and removing/ cutting burned part of cable including taking out loop for extension of cable upto required length and fixing /connecting the cable in existing position including necessary nuts, bolts, lugs of approriate size and refixing of cable gland for following sizes complete all as specified and as directed by Engr-in-charge. Note: The quoted rate includes neccessary earth work and supply and fixing of lugs of appropriate sizes.
185 sqmm to 240 sqmm
95 sqmm to 120 sqmm
50 sqmm to 70 sqmm
25 sqmm to 35 sqmm
Material and labour for welding works to existing LT feeder pillar box/ panel board doors including removing broken hinges and supply and fixing new heavy duty hinges as per existing type and quantity including painting with synthetic enamel paint over redoxide on the welded surfaces to make good the disturbed surface and match with existing tint complete all as specified and as directed by Engr-in-charge.
Taking down existing defective panel board indication lamp (R /Y /B colour) from the panel and replaced with LED indicator lamp complete all as specified and as directed by Engr-in-charge.
Taking down existing defective VAF meter from the panel board and replace with new VAF meter, class1, with LED display, for showing voltage, Amps, frequency including necessary wiring and wiring materials complete all as specified and as directed by Engr-in-charge. Make: AE/ Siemens /Schneider /L&T
Material and labour for cleaning and servicing complete for LT ACB of capacity upto 630 Amps any type including contacts and busbars connections with CRC spray, checking the incomming and out going bus bar connections /power cable and tightening of all bolts, nuts at power cables/ bus bar including replacement of burnt copper/ aluminium lugs as per site requirement, removing the carbon deposit and reconditioning of door lock complete all as specified and as directed by Engr-in-charge.
All as per item No.05 here-in-before but for LT ACB capacity above 630 Amps and upto 1250 Amps any type.
Material and labour for writing in coming and out going details in LT panel as per site requirement, with letter height not less than 15mm, boldly and solidly with thin self adhesive sticker of approved tint complete all as specified and as directed by Engr-in-charge. Note: Writing for each incomming/ out going feeder /breaker in the panel shall be measured as one job.
Material and labour for dismantling, taking down, checking, cleaning and servicing of switch gear of rating 315 A to 400 A MCCB any type contacts with CRC spray including checking the bus bar connections /power cable from Main Bus bar to MCCB and out going cable connections of MCCB, tightening of incomming and outgoing cables including replacement of Copper /Aluminium lugs as per site requirements including removing the carbon deposit and replacing the gasket of compartment door, reconditioning of door lock complete all as specified and as directed by Engr-in-charge. Make: Schneider /ABB /Legrand /Siemens
All as per item No.08 here-in-before but for switch gear of rating 200 A to 250 A MCCB any type. Make: Schneider /ABB /Legrand /Siemens
All as per item No.08 here-in-before but for switch gear of rating 100 A to 160 A MCCB any type. Make: Schneider /ABB /Legrand /Siemens
All as per item No.08 here-in-before but for switch gear of rating 63 A MCCB any type. Make: Schneider /ABB /Legrand /Siemens
Material and labour for preparation of old plastered or unplastered cemented surface and applying two coats of white wash on cemented surface/ wall etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for MCCB adjustable thermal and fixed magnetic setting 4 Pole of rating 400 Amps, ICS=100% ICU, breaking capacity 35 KA including additions /altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting in /out going bus bar or cable connections including supply and fix suitable rating/ size lugs, extended terminals as per site requirements and making good disturbed panel surfaces complete all as specified and as directed by Engr-in-charge. Make: Schneider /ABB /Legrand /Siemens
All as per item No.13 here-in-before but for MCCB of rating 320 Amps, ICS=100% ICU, 4 pole, Breaking capacity 35 KA. Make: Schneider /ABB /Legrand /Siemens
All as per item No.13 here-in-before but for MCCB of rating 250 Amps, ICS=100%ICU, 4 pole, Breaking capacity 35 KA. Make: Schneider /ABB /Legrand /Siemens
Material and labour for straight through cable heat shrinkable joint kit for 1.1 KV grade complete with jointing material and accessories like lugs etc., complete suitable for following size XLPE cables complete all as specified and as directed by Engr-in-charge.
150 sqmm 3.5 core to 185 sqmm 3.5 core
50 sqmm 3.5 core to 120 sqmm 3.5 core
25 sqmm 4 core to 35 sqmm 4 core
Surface excavation not exc 30 cms deep and average 15 cms deep and getting out in soft/ loose soil including removing green vegetation, roots, bushes etc., from surroundings of poles, panels, etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for cutting of bituminous road/ floor for laying of pipe/ cables not exc 1.5m wide and not exc 1.5m deep including refilling with material and watering well ramming compacting and making good with PCC 1:2:4 type B-1 suitable thick complete all as specified and as directed by Engr-in-charge. Note: PCC shall be measured and paid separately under respective item of schedule.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth for taking up/ laying cable etc., and getting out for soft/ loose soil complete all as specified and as directed by Engr-in-charge.
Taking up existing old/ unserviceable/ burnt under ground cable from the existing positions/ trenches etc., including testing with the help of megger, disconnecting and removing unserviceable portion of cable complete all as specified and as directed by Engr-in-charge. Notes: (i) Excavation/ earth work shall be measured and paid seprately under relavent items. (ii) Retrived serviceable bricks from site be properly stacked and reused as protection to UG cable and shall be measured and paid separetely under relevent items. (iii) Serviceable portion of cable shall be relayed as directed and shall be measured and paid separetely under relevent items.
240 Sqmm 3.5 core
185 sq mm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
Relaying serviceable portion of cable as obtained against item No.20 here-in-before in the trench including neccessary connections with suitable lugs complete all as specified and as directed by Engr-in-charge. Note: Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
240 sqmm 3.5 core
185 sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
Supply, laying XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 V grade, with aluminium conductor of following size for replacement of unserviceable portion of cable including connecting up with proper size aluminium lugs, glands wherever necessary in LT panels/ bus bar chamber panel /joints etc., all as per site requirement including testing complete all as specified and as directed by Engr-in-charge. Make: POLYCAB/ NICCO/ PLAZA/Havells/ KEI Notes: (i) Rates includes supply and fix necessary glands,lugs, etc., (ii) Excavation/ earth work shall be measured and paid separately under relevent items. (iii) Cable straight through joints/ bus bar chamber if any as per site requirement shall be measured and paid seprately under relevent item of schedule.
240 sqmm 3.5 core
185 sqmm 3.5 core
120 sqmm 3.5 core
95 sqmm 3.5 core
50 sqmm 3.5 core
25 sqmm 4 core
Spreading riddled earth as obtained from item No.19 here-in-before for UG cable cushioning complete all as specified and as directed by Engr-in-charge. Note: If the required quantity of riddled earth not obtained from above item the contractor should bring the same from other location shown (not beyond 50m) including necessary earthwork as directed for borrow pit /trench to obtain the required quantity including removing surplus soil without any additional cost and the cost deemed to be included in the rate quoted by the contractor.
Supply and lay pipe galvanised iron tubing light grade of 50mm dia in trenches/ under road or floor/on wall/ near pole/ panel etc., including taking out the corroded old pipe complete all as specified and as directed by Engr-in-charge. Make: Tata /Jindal /Prakash /Surya
All as per item No.24 here-in-before but galvanised iron tubing light grade of 80mm dia. Make: Tata /Jindal /Prakash /Surya
All as per item No.24 here-in-before but galvanised iron tubing light grade of 100mm dia. Make: Tata /Jindal /Prakash /Surya
All as per item No.24 here-in-before but galvanised iron tubing light grade of 40mm dia. Make: Tata /Jindal /Prakash /Surya
Supply and lay standard size common burnt clay building bricks sub class 'B' for cable protection, laid dry complete all as specified and as directed by Engr-in-charge.
Relaying of serviceable bricks as obtained from item ser No.19 here-in-before complete all as specified and as directed by Engr-in-charge.
Material and labour for PCC in roof kerb or mud stops, rounded or chemfered on edges type, road cutting filling etc., PCC 1:3:6 (Using 20mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cms for soft /loose soil complete all as specified and as directed by Engr-in-charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with using GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground and connected to GI earth strip 32x6mm by means of GI bolts and nuts, check nuts, washers and GI strip protected by GI pipe light grade 40mm bore and connecting to Panel /DBs etc., as per site requirement including alternate layers of charcoal and salt crystal, neccessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC Cover with 6mm dia MS bars 10cm c/c on both ways as reinforcement complete including watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No.3 of MES Schedule Part 1 complete including testing on completion complete all as specified and as directed by Engr-in-charge. Notes: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc., (ii) GI earth strip, GI tubing light grade 40mm bore upto 7.5m deemed to be included in the rate quoted by the contractor. (iii) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm. If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Material and labour for MCCB adjustable thermal and fixed magnetic setting 415V, 3 Pole of rating 200 Amps, ICS=100% ICU, breaking capacity 36 KA including additions/ altertions to existing MCCB mounting place in the panel for properly fixing and reconnecting in/ out going bus bar or cable connections including supply and fix suitable rating/ size lugs, extended terminals as per site requirements and making good distrubed panel surfaces complete all as specified and as directed by Engr-in-charge. Make: Schneider /ABB /Legrand/ Siemens
All as per item No.34 here-in-before but for MCCB of rating 160 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA. Make: Schneider /ABB /Legrand/ Siemens
All as per item No.34 here-in-before but for MCCB of rating 63 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA. Make: Schneider /ABB /Legrand/ Siemens
All as per item No.34 here-in-before but for MCCB of rating 100 Amps, ICS=100%ICU, 3 pole, breaking capacity 16 KA. Make: Schneider /ABB /Legrand/ Siemens
Taking down the existing unserviceable power contactor from the panel and replaced with new contactor complete for the folowing capacity complete all as specified and as directed by Engr-in-charge.
3 phase power contactor, 440 volts, 50Hz, 350 Amps
3 phase power contactor, 440 volts ,50Hz, 230 Amps
3 phase power contactor, 440 volts, 50Hz, 160 Amps
Supply and fix GI pipe light grade 15mm dia on walls, roof/ laid on floors, ground etc., with all fittings as GI wire protection complete all as specified and as directed by Engr-in-charge. Make: Tata /Jindal /Prakash/ Surya
Supply, fix, drawn GI strip 32x6mm in replacement complete all as specified and as directed by Engr-in-charge.
Material and labour for cleaning and preparation of old painted surfaces and painting with one coat of aluminium paint on LT steel tubular poles upto 9m height and including clamps and street light brackets and three runs of photo reflective self adhesive weather proof tape in three approved tint in three layers complete all as specified and as directed by Engr-in-charge.
Material and labour for earthing complete with using GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground and connected to GI earth wire 4mm by means of GI bolts and nuts, check nuts, washers and GI earth wire protected by GI pipe light grade 15mm bore and connecting to Panel /DBs etc., as per site requirement including alternate layers of charcoal and salt crystal, neccessary excavation, earth work in any type of soil PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC Cover with 6mm dia MS bars 10 cm c/c on both ways as reinforcement complete including watering pipe 20mm dia medium grade with funnel complete with mesh all as shown in electrical plate No.3 of MES Schedule Part 1 complete including testing on completion complete all as specified and as directed by Engr-in-charge. Notes: (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc., (ii) GI earth wire, GI tubing light grade 15mm bore upto 7.5m deemed to be included in the rate quoted by the contractor. (iii) Quoted rate include testing after completion from test point and the desired earth resistance shall be not more than 2 ohm. If the desired result is not obtained the earthing will be re done by the contractor at no extra cost.
Supply, fix, drawn GI wire 4mm complete all as specified and as directed by Engr-in-charge.
Taking down old unservicaeble cable any make /type/ size and supply and draw PVC insulated unarmoured round flexible copper conductor cable multistranded of 3 core 1.5 sqmm with necessary lugs etc., complete all as specified and as directed by Engr-in-charge. Make: Plaza/ Finolex/ Havells/ Polycab/ KEI
Taking down old/ unserviceable/ burnt LED light fittings from existing positions including necessary T&P, ladder etc., as per site requirement carefully, checking of fitting for defect and refixing the same in existing position or any other location after repair as directed complete all as specified and as directed by Engr-in-charge. Notes: (i) Spare parts as required shall be arranged by the Dept from fitting manufacturer aganist their warranty of fittings with Dept, However if any replacement of minor burnt wires require, the same shall be included in the rate quoted. (ii) Quoted rate is deemed to be included the charges of T&P, labour etc., complete as per site requirement.
Taking down old unservicaeble security light junction box /bus bar box etc., from existing security light poles/ wall from existing positions including disconnecting existing cable connections carefully and MS clamps etc., complete all as specified and as directed by Engr-in-charge.
Taking down old /burnt out aluminium sub main wire from existing street light pole of any type/ other similar locations complete all as specified and as directed by Engr-in-charge.
Material and labour for black stove enamelled rigid ERW steel conduit 20mm dia fixing with suitable size and type MS clamps/ saddles as per site requirement complete all as specified and as directed by Engr-in-charge. Make: BEC /EMCO/ GARWARE /JINDAL/ WAVIN/ FINOLEX Notes: (i) Quoted rate for conduit is deemed to be included for the taking down existing unserviceable conduit as per site requirement complete. (ii) New sub main wiring for replacement of unserviceable wiring as required as per site requirement shall be measured and paid separately under relevant schedule items.
Material and labour for sub main wiring with two single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wiredrawn in existing conduit complete all as specified and as directed by Engr-in-charge. Make: Plaza/ Finolex/ Havells/ Polycab/ KEI
Supply and fix for MCB TPN 415 V, 40- 63 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/ Schneider /ABB
Supply and fix for MCB SP 230 V, 6-32 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/ Schneider /ABB
Supply and fix for MCB SP 230 V, 40-63 Amps 'C' curve including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. Make: Legrand/ Siemens/ Schneider /ABB
Supply and fix for GI bracket for street light made out of 40mm dia GI pipe medium grade 1.5m length bend in shape/ as required complete including MS flat iron clamps, nuts and bolts etc., all as directed and specified including dismantling, taking down old damaged one complete all as specified and as directed by Engr-in-charge.
Supply, fixing and testing LED street light luminaire fitting not less than 60 Watt and not less than IP 65 protection comprises of pressure die cast aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge. Make: Surya Roshini Ltd Cat Part No. SLE UL 60W IP66 LXN /Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd Notes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Material and labour for removing of existing cable loop from under ground, and rectification of fault/ removing damaged cable portion and rearrange the cable in same existing location and making proper connections including lugs, nuts, bolts and necessary earth works etc., complete all as specified and as directed by Engr-in-charge.
Supply, fixing and testing powder coated outdoor street light control box of size not less than 300x200x80mm CRCA 3mm thick IP 65 fabricated by CPRI certified panel manufacturer including suitable terminal TPN 10 KA SMC connector (for 3 Phase Cable Line IN and OUT) and provision of dimrail for mounting 3 Nos MCB SP including supply and fix 01 No MCB 6 A SP 'C' curve (Make: Siemens / Schneider /Legrand /ABB), canopy weather proof, hinged door with Two hinges, pad side locking system - 02 Nos (top and bottom), for fixing on PCC/ steel poles in and including necessary MS clamps - 02 Nos of suitable shape and size with nuts, bolts and washers as per site requirement complete all as specified and as directed by Engr-in-charge. Notes: (i) Drawing shall be approved from Dept by the contractor before placing a order to CPRI certified panel manufacturers. (ii) The cost deemed to be included in the quoted rate for reconnecting old existing cables to boxes carefully using a suitable glands and also taking up loop from the under ground and making good in all respect where ever required as per site requirement including necessary earth work complete all as specified and as directed by Engr-in-charge.
Supply, fixing and testing LED street light luminaire fitting of not less than 45 Watt and not less than IP 65 protection comprises of Pressure die cast Aluminium housing powder coated, with luminaire efficiancy not less than 100 lm/w provided with surge suppressor 5 KV complete including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge. Make: Surya Roshini Ltd Cat Part No. SLE UL 45W IP66 LXN/ Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd Notes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Cutting and Trimming of tree branches around street/ security poles or light fittings etc., to clear the tree branches around the pole and maintain a clearance of 1.50m radius aroung the pole top or light fitting complete all as specified and as directed by Engr-in-charge. Notes: (i) An area of 1.5m surrounding the pole to be cleared off trees branches. (ii) Measurement and payment will be made for all cutting/ trimming near top of the each pole as one job only.
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer including preparing the surface and removing old corroded item complete all as specified and as directed by Engr-in-charge.
Taking up broken and unserviceable standalone solar street light pole complete from the existing locations and store aside for repair complete all as specified and as directed by Engr-in-charge.
Demolition and dismantling of concrete of any description of standalone solar street light pole foundation, coping etc., complete all as specified and as directed by Engr-in-charge.
Re-erecting stand alone solar light pole as obtained item No.60 here-in-before, after necessary welding works including MS work to pole and making good in all respect as per site requirement, testing complete all as specified and as directed by Engr-in-charge. Note: PCC shall be measured and paid separately under relevant item.
Supply, fixing and testing LED flood light fitting of not less than 100 Watt and not less than IP 65 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 100 lm/w provided with surge suppressor 10 KV including taking down the old unserviceable/ damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge. Make: Surya Roshini Ltd Cat Part No. SLE FL 100W IP66 LUMOS/ Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd Notes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Material and labour for PCC foundation for standalone solar street light pole wherever necessary 1:4:8 type D-2 (Using 40mm graded stone aggregate) complete all as specified and as directed by Engr-in-charge.
Material and labour for servicing, overhauling, caliberation, conditioning, repairing, cleaning to old/ unserviceable PV cell system, charge controller system complete of stand alone solar street light system as per site requirement to make functioning of PV cell system, charge controller system in all respect complete all as specified and as directed by Engr-in-charge.
Taking down old/ unserviceable lead acid battery from existing standalone solar street light system located at various locations carefully all as per site complete all as specified and as directed by Engr-in-charge.
Supply and fix for sealed maintenance free lead acid battery 12 V, 100 AH in and including new terminals/ lugs, wiring as per site requirement complete all as specified and as directed by Engr-in-charge. Make: Exide/ Amaron/ TATA
Supply, fixing and testing LED flood light fitting of not less than 150 Watt and not less than IP 65 protection comprises of pressure die cast aluminium housing powder coated, toughened glass, luminaire efficiancy not less than 110 lm/w provided with surge suppressor 10 KV including taking down the old unserviceable /damaged light fittings and making good disturbed surfaces complete all as specified and as directed by Engr-in-charge. Make: Surya Roshini Ltd Cat Part No. SLE FL 150W IP66 LUMOS/ Philips /Wipro /Crompton/ Luker Electric technologies Pvt Ltd Notes: (i) Quoted rate is deemed to be included the charges of necessary Ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS frame work if any complete as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Supply and fixing in repair of LED street light luminaire complete suitable for solar street light DC supply of not less than 15 Watt with LED driver and auto dusk and dawn off control, IP65 outdoor type in and including all necessary new wiring with 1.5 sqmm copper for PV panel, battery, MCB, including supply and fix charge controller as per site for making functioning of LED on solar light on existing stand alone solar system, servicing, cleaning of PV panel complete, testing and commissioning complete all as specified and as directed by Engr-in-charge. Make: Surya Roshini Ltd/ Philips /Wipro /Havells /Crompton/ Luker Electric Technologies Pvt Ltd Notes: (i) Quoted rate is deemed to be included the charges of necessary ladder, tools and plants, necessary drilling, bolts /screws for fixing new one etc., as per site requirement and MS work as per site requirement. (ii) Contractor should submit warrenty certificate for 5 years for the luminaries from manufacturer.
Taking down unserviceable LED light fittings of any watt and type from existing position on pole/ wall/ tower/gate, complete for and including repair and refixing in existing position after repair complete all as specified and as directed by Engr-in-charge. Notes: (i) New spare parts required for replacing old unserviceable parts shall be measured and paid separately as 'Supply only’ under relavent item here-in-after. (ii) Labour cost for replacing spare parts, removing unserviceable parts, dismantling light fitting and refixing are deemed to be included in the quoted rate.
Supply only surge protection devices any type and KV for following capacity flood lights/ post top latern lights/ street light/ security lights including necessary connecting arrangements as per site requirement complete all as specified and as directed by Engr-in-charge. Make: Philips /Wipro /Surya Roshini Ltd/ Crompton/ Havells/ Luker Electric technologies Pvt Ltd
Surge protection devices not less than 5 KV suitable for LED light fittings upto 75 watts.
Surge protection devices not less than 5 KV suitable for LED light fittings 75 watts to 150 watts.
Supply only oudoor drivers any type and following wattage for flood lights/ post top latern lights /street light/ security lights including necessary connecting arrangements as per site requirement complete all as specified and as directed by Engr-in-charge. Make: Philips /Wipro /Surya Roshini Ltd/ Crompton/ havells/ Luker Electric technologies Pvt Ltd
Out door type drivers suitable for 25 watts LED lights
Out door type drivers suitable for 40 watts LED lights
Out door type drivers suitable for 45 watts LED lights
Out door type drivers suitable for 75 watts LED lights
Out door type drivers suitable for 150 watts LED lights
Material and labour for preparation of old plastered or unplastered cemented surface and applying two coats of white wash on cemented surface /wall etc., complete all as specified and as directed by Engr-in-charge.
Material and labour for writing pole number on any type of pole, painted with thick paint, boldly and solidly with white colour letters over black colour circular base complete all as specified and as directed by Engr-in-charge.
Supply, laying, testing 16 sqmm 4 core XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with aluminium conductor for replacement of unserviceable portion of cable, connecting with proper size aluminium lugs, glands whereever necessary near LT Panels/ Bus bar chamber panel/ joints /poles including taking down the old unsevicaeble cable complete all as specified and as directed by Engr-in-charge. Make: POLYCAB/ NICCO/ PLAZA/ Havells/ KEI
SIVA ENTERPRISES
C SRINIVASAN
RD ENTERPRISES
K R ENTERPRISES
SREE BALAJI ENTERPRISES
SRI VIGNESH BUILDERS
Raju Builders
N SRINIVASAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .