| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹4.0 Cr+₹28.9 L (7.70%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | ₹4.0 Cr+₹28.9 L (7.70%) | L2 | Rejected-Finance Being other than lowest |
| 3 | L3₹5.0 Cr+₹1.3 Cr (34.4%)Rejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹5.0 Cr+₹1.3 Cr (34.4%) | L3 | Rejected-Finance Being other than lowest |
Tender Value
₹4.8 Cr
EMD Value
₹5.5 L
Closing Date
5 Jun 2020, 6:00 pmClosed
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
ADDITIONS ALTERATIONS TO CERTAIN BUILDING OF SAILORS MARRIED ACCOMMODATION SMA AT RS COLABA MUMBAI UNDER GE NW NAVY NAGAR
2020_MES_329883_1
8185/CWE(NW)MUMBAI
Open Tender
Civil Works
Item Rate
365 days
GE NW Navy Nagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
Yes
GE (NW) Navy Nagar
₹5.5 L
Yes
14 Jul 2020
29 Feb 2020
8 Jun 2020
29 Feb 2020
5 Jun 2020
20 Mar 2020
29 Feb 2020 - 19 Mar 2020
Amount
Taking down CI soil/waste/vent pipes including all fittings like shoes bends swan necks etc of any dia complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F CI soil/waste/vent pipe in any length with ears 100 mm bore ( centrifugally cast) in any length with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F CI soil/waste/vent pipe in any length with ears 75 mm bore ( centrifugally cast) in any length with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F in repair PVC (SWR) pipes 160mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F PVC (SWR) bends/shoes 160mm bore any radius complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
13th floor to up to and including 14th floor.
S&F CI bends (any radius) for soil/waste pipes 100 mm bore diminishing pieces or tapers with oval access door on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F CI bends (any radius) for soil/waste pipes 75 mm bore diminishing pieces or tapers with oval access door on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F CI branch pieces single 'Y' (equal or unequal) ordinary or inverted (spigot or socket type) with parallel branches for 100mm bore pipe with ovel access door complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F CI branch pieces single 'T' (equal or unequal) ordinary or inverted (spigot or socket type) with parallel branches for 75 mm bore pipe with ovel access doorcomplete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Demolition of lime concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge..
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Demolition of brickwork built in cement mortar or cement lime mortar including all quoins,arches, pillars complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L cement concrete 1:7:12 F2 type with with 40mm graded stone coarse aggregate in sunken floor complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M & L non skid ceramic tiles coloured of size 400x400x6 to 7mm thick laid in floors over cement mortar, screeding, set and jointed in white cement mixed with pigment including bedding layer of mortar 20mm thick in CM 1:4 for laying floor finishes complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M & L Coloured glazed ceramic tiles 450 x 300 x 7mm on vertical surfaces set & jointed in neat cement slurry and pointed in white cement mixed with pigment over backing layer of 10mm thick in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F stainless steel hooks 4 mm dia and100mm long fixed in walls for tieing the GI/naylon rope for drying clothes in balcony including drilling ,cutting and concreting complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L machine cut cudappah stone 20-25 mm thick over base,laid and jonted with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in shelves complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Cutting chases,pinning in ,making good to facing where required and pointing in cement mortar 1:3 to ends or edges of shelves etc,and making good ,cutting n exc 10 cm girth in brick walls
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S/F IS embossed (IS 13983) single bowl stainless steel kitchen sink with drainage board in glossy finish made of stainless steel grade 304/AISI 18/8 & 1mm thick with overall size 915mmx460mm and bowl size 410mmx330mmx160mm depth. Sink shall be connected with 32 mm dia waste coupling and PVC waste pipe of flexible type complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L hand cut Kota stone ( greenish colour, mirror polished) slab flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including polishing over and including 20mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L machine cut Kota stone ( greenish colour, pre mirror polished) slab in one piece as in cill /staircase treads flooring 18 to 20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of slab incl polishing over and including 20mm thick screed bed in CM 1:4 complete all as specified.( window cill single piece to be executed in two steps and rate shall be included)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Ditto all as per item above but as in riser/window Jambs (should be one piece) over 10mm thick backing coat in CM 1:3
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Ditto all as per item above but as in skirting .
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Rounding to edges of stone slabs one edge,such as in steps,cooking plateform,and other similar situations complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Extra for two No grooves over stair case treads complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L vitreous china squatting pan Orissa pattern of size 580 x 440 mm white with back inlet and integral footrest and anti syphonnage pipe including 'P' or 'S' trap and provn of lime concrete complete all as specified supplied and fixed in repairs complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F 32 mm dia., Waste fittings, brass chromium plated for stainless steel sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F pillar tap 15mm bore, cast copper alloy fancy type chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F PVC connection 15mm size with PTMT nuts of length 450mm
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 32mm dia LDPE PVC waste pipe for WHB in repairs includding socket & screw
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F High density PVC pipe of pressure rating 6 kgf/Sq.cm of 40 mm bore for outlet pipe for WHB and kitchen sink complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F Flushing cistern 10 Ltr capacity ISI marked ,white feather touch PVC low level of make as specified and appproved including with 32 mm bore polythene flush pipe of sufficient length , including internal fittings (valveless syphonic) white colour, ISI marked (IS 7231) and including brackets,all complete as directed by Enginner -in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L CI Nahani trap dia of outlet 75mm fixed in repairs including jointing to waste pipe in cement joint and fixing in cement concrete type B1 (1:2:4)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F PTMT grating doom over Nahani trap and floor trap of 100mm Dia complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down chowkats with shutter (without taking shutter from the frame) not exc 1.5 sqm each complete all as specified and directed by Engineer-in-Charge. .
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down chowkats with shutter (without taking shutter from the frame) exc 1.5 sqm each but not exc 4 Sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
Taking down shutters of any description exc 1sqm and n exc 2 sqm each complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F second class HW plain & framed solid stright chowkats & wrought framed rebated on the solid rounded to chamfered put together with glue pinned at joints.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm PLAIN COLOURED PVC sheet reinforced with MS square tube, to match complete all as specified.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M & L preparing surfaces of wood and wood based materials, and treating back of chowkats with tar or coal tar black paint etc area exc 0.1sqm but n exc 0.5sqm each complete all as specified and directed by Engineer-in-Charge.
S & F mild steel hold fasts, wall ties and similar small articles conforming to Fe 290-0 or E 165 complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain coloured PVC sheets and 5mm thick x 15mm wide PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail ; Panelling of PLAIN COLOURED PVC sheet joined together with solvent cement supplying & fixing in the frame at site as per specification and drawing complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
(c) 9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F 35mm thick second class hard wood factory made plain framed panelled shutters (two panes) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board medium density with commercial veneering both face. The size of rail shall be as per IS 1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F 40mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F 25 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F Second class hard wood factory made glazed and skeleton shutters 35 mm thick, open rebatede and prepared to receive glass, gauze etc (without sash bars), edges of framing plain chamfered of rounded, fitted with cut and mitred beads for securing glass etc. Sizes of members of shutters shall be as specified in SSR PartI, sec 8.24 (a).
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F stainless steel butt hinges100mm size, medium weight complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F in repairs stainless steel hinges100mm size, medium weight.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F aluminium anodised sliding door bolt with hasp and staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, length of bolt 300mm complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 150mm long aluminium anodised tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 125mm long aluminium anodised tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 150mm size extruded aluminium anodised alloy handles fabricated type complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
(d) 13th floor to up to and including 14th floor.
S&F 125mm size extruded aluminium anodised alloy handles fabricated type complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F anodised aluminium powder coated frame/track or shutters for windows, ventilators etc. with one or more rebates including joining cleat for fixing etc.fixed or sliding type/louvered window or ventilator without sash bar, aluminium including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws including looking arrangement etc. complete all as specified Complete all as specified. Note: Minimum 25 micron anodisation for all aluminium sections)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 100mm long aluminium anodised powder coated tower bolt of extruded section complete all as specified and directed by Engineer-in-Charge
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 100mm size extruded aluminium anodised alloy handles fabricated type complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L aluminium powder coated grill with suitable aluminium anodised frame section of ‘F’ section of size 23.4 x 15.3 x 1.4 mm thick manufactured by M/S Deco grill pattern DG-102 (7.5mm dia and aparture 50mm) complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F Floor door stopper of Aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, Overall length of cover plate 150 mm complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F aluminium alloy wire mesh 0.45 mm nominal dia of wire and average width of aperture 1.4 mm fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Ditto all as per item above but fixed in repairs
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 4 mm thick figured glass pin headed type and glazing with aluminium and neoprene beads in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F 4mm thick plain sheet glass ordinary quality and glazing with aluminium and neoprene beads in square exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L anodised aluminium sheeting 22 gauge thick fixed in repairs as in crumple section complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F mild steel, chromium plated curtain rails for cup boards shutters including brackets complete all as specified and directed by Engineer-in-Charge..
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F aluminium anodised 20mm dia, D type, 60cm long tubular towel rail complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for powder coated aluminium serrated finish 25mm dia curtain rod fixed with sheet metal C/P screws rovel plugs with and including MS powder coated decorative dome type, curtain rod side brackets pair fixed etc complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F teak wood lipping 6mm thick and 25 to 40mm wide around the flush shutter, panelled, glazed or gauzed joinery, re-newed, including mitres complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F Beads, straight (any size) 2nd class HW for around the prelaminated partical board, panelled,glazed or gauzed joinery, re-newed, including mitres complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S&F hasp and staple safety type,aluminium anodised including bolt to hinge plate and fixed with screws 150mm size complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
S & F 30mm thick block board, grade-1 quality exterior grade commercial type fixed with screws to timber frame work of width n.exc. 25 cm in shelves or built-in cupbords, almirahs and similar work with lipping patti & painting complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Dismantling of MS grill of any description and position etc.
S & F magic eye fancy type of brass for door including drilling cutting of holes and making good
M&L for fabrication of framed work as MS grills. with ends of bars shouldered and or riveted or forged into spikes, framed guard bars barred iron doors, ladders framed balusters, walk ways, railings, framework of water tanks and similar work conform to Fe 290 Gde-E-165 & fixed in position complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L Brick work with sub class `B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L type C1, 1:3:6 type(20mm graded stone aggregate) cement concrete cast in situ as in steps , bed block or hold fast complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking down cement plaster, any description on brick or stone walls, etc including racking out joints hacking for key scrubbing down with water complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L plastering 20mm thick in two coats 15 mm Backing coat in CM 1:4 and 5 mm thick setting coat in CM 1:3 using liquid WPC of approved make on Brick or concrete surfaces with recrene finish all complete as directed by EIC.(WPC shall be measured & paid seperately)
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Supply only liquid water proofing compound of approved make complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L Rendering 15mm thick in CM 1:6 on brick wall /concrete finished even and smooth complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L Rendering 10 mm thick in CM 1:3 on ceiling finished even and smooth complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Complete removal of existing treatment from wall surfaces by scrapping, washing & applying two coat of Oil bound distemper of approved make on wall over a coat of wall priming paint over a coat of Birla white putty on plastered surface and filling the surface inperfections such as holes, dirt, fine cracks all complete including preparation of surfacescomplete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M & L for preparing newly plastered or unplastered surface and applying two coats OBD over one coat of wall priming paint over 1 mm thick wall care putty all complete incl necessary scaffolding complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of surface plastered or unplastered new surfaces and applying three coats of white wash on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item above but on ceiling.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of surface plastered or unplastered old surfaces and applying two coats of white wash on walls complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Ditto all as per item above but on ceiling
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M & L for preparation of walls & applying two coats of chemical waterproofing treatment(601 raincoat of Pidilite or Dr.fixit or equivalent) of approved colour on wall such as Flexcoat, Beckcoat Exshield etc or equivalent over a coat of primeseal/primers complete as per manufactures Instructions complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item above but on ceiling.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L preparation of old decorated surfaces of wall including washing and applying two coat of Acrylic emulsion paint exterior grade (100% Acrylic) over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
All as per item above but on ceiling.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of new or previously untreated surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying one coat of pink primer and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of old painted surfaces of wood or wood based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paintcomplete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of new or previously untreated surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying one coat of red oxide primer and two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
M&L for Preparation of old painted surfaces of steel or steel based materials of any description not other wise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of anti-rust priming coat complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Writing letter or figures n exc 30 cm high complete all as specified and directed by Engineer-in-Charge.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Removing demolished materials outside MD land to a distance exc 5Km but n exc 10Km complete all as specified and directed by Engineer-in-Charge.
M/L for cement concrete work in pavement/hard standing of flexural strenght 40 kg/sqcm in field using 400kg of cement per cubic metre for thickness less than 25cm complete all as specified and directed by Engineer-in-Charge.
Forming contraction dummy joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A' in floor complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete colour interlocking tiles 60 mm thick having glossy finish/(colour and pattern approved by GE) strength not less than 350 Kg/Sq CM laid over and including 20 mm thick dry sand cushioning and void filled with dry and compact, including compation by means of surface vibratorcomplete all as specified and directed by Engineer-in-Charge.
M/L for Excavation in over areas in soft/loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
M&L Hard core of gauge n.exc 63mm deposited spread and levelled in layers n.exe 15 cm thick watered and rammed to a turre surfacecomplete all as specified and directed by Engineer-in-Charge.
M/L for 75mm thic PCC 1:3:6 type C2 ( using 40mm graded stone aggregates) as in sub base to floors, pavements complete all as specified and directed by Engineer-in-Charge.
M/L for forming groove in walls of uniform size 15mm wide and 15mm deep in CM 1:3 as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove at any height complete all as specified and directed by Engineer-in-Charge.
Taking down plaster (Chipping off ) removing ,carefully Loose plaster by low impact Hammer without damaging the structure and cleaning and disposal of debris out side the premises complete all as specified and directed by Engineer-in-Charge.
Chipping, removing carefully loose concrete work by low impact hammer ,breaker without damaging the structure & cleaning and disposal of debris outside the premises etc. ( Hard concrete should not be removed by force) complete all as specified and directed by Engineer-in-Charge.
Dismantling, Removing,Carefullly Concrete work by low impact Hammer ,Breakar without damaging the structure & cleaning and disposal of malba out side the premises complete all as specified and directed by Engineer-in-Charge.
Dismantling of brickwork of any discription and in any position complete all as specified and directed by Engineer-in-Charge.
M & L for clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete, Applying two coats of alkaline rust converting primer FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr Fixit Rust removal or sholirust of STP Ltd. on the rebars,including cleaning the reinforcement ,wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and directed by Engineer-in-Charge.
M & L for providing and fixing additional steel bar or stirrups of diameter in variuos structural elements like columns,beams and foundations including drilling,bending and fixing the bars with epoxy putty complete all as specified and directed by Engineer-in-Charge.
M & L for carry out application of ‘Bi-polar migratory corrosion inhibitor' EPCO-KP-100 on concrete surface. This inhibitor has migratory kind of property which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibiting the corrosion and de-passivating the Electro-chemical reaction. It has property to attack anode as well as cathode, which is purely alkaline in nature (pH-9.5), so it has no carcinogen activity with concrete complete all as specified and directed by Engineer-in-Charge.
M & L for applying two coats of anticorrosive Treatment to Reinforcement by application of two coats of anti-rust protective coating in the form of Acrylic Polymer with a minium splid content to 40% solid mixed with cement in 1:1.5 proportion ( 1 part polymer and 1.5 part cement) on rebars after cleaning of rust scales with time interval of minimum 4 hours between each coat by brush as per manufacturers instruction.Anti-rust protective shall be procured from one of manufacturer given below complete all as specified and directed by Engineer-in-Charge. (Make :- Fosroc/Sika/BASF/ Krishna Conchem)
M & L for providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster conforming to ASTM-C-882-91 (Arizona Slant Shear Test) to ensure bond between old concrete and new concrete complete all as specified and directed by Engineer-in-Charge.
M & L for provide and apply polymer bonding agent followed by flexible polymer based putty and shall be filled in properly cut 'V' groove in cracks of structural elements,finish with spatula etc. complete all as specified and directed by Engineer-in-Charge.
M & L for providing and applying jacketing around columns,beams,slabs,chajjas etc with Micro concrete (molith-MC) M40 including all lifts, shuttering,drilling holes and fixing shear anchor complete all as specified and directed by Engineer-in-Charge. Note: Reinforcement shall be measured and paid separately (Rates including jacketing, formwork and micro concret)
M & L for building up the profile of structural members by using latex B2 modified air cured mortar system in damaged areas (1Cement-3 part graded cleaned pre-packed river sand 10% latex mortar by weight of cement-0.5 w/c ratio) upto 20 mm to 40 mm thickness including leveling profiling and removing and cleaning existing vegetation growth in structural and Non structural items all complete etc. complete all as specified and directed by Engineer-in-Charge. (Make :- Fosroc/Sika/BASF/Krishna Conchem)
M & L for Injecting low viscosity MONOPOL (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout ,including ,mixing of materials : Mixing of material components(part a & b) in the required quantities as per manufacturer's instruction by weigfh batching. Grouting maintain the pressureat exit (0.5 to 1.0 kg/cm2 ) by monitoring pressure guage at exit.Grout the material through Prefixed nozzles in the structural elements @ 100 ml per nozzle. Repeat the process for all the nozzles.(Beam and Columns) complete all as specified and directed by Engineer-in-Charge.
M & L for anchoring reinforcement bar in exisiting RCC member in holes of minimum 10d depth for 8 to 12 mm dia. Bars and grouting in position with locfix (fosroc), including drilling of holes,cleaning etc.complete all as specified and directed by Engineer-in-Charge. (only applicable for complete recasting).
M & L for providing and Casting in position a mix of (M30 Grade) made clean sharp aggregates 10 mm and below along with addition of Non shrink admixure including transporting, mixing, laying, curing, etc complete all as specified and directed by Engineer-in-Charge.
M & L for brick work in 1:6 cement mortar around the structural members like column or beam after repair of structural members in proper line and level including raking of joints etc. complete all as specified and directed by Engineer-in-Charge. (Scaffolding and enabling items paid seperately)
M & L for centering and shuttering including struttings, propping etc. and removal of formwork in 12 mm thick plywood, including application of shuttering oil, complete all as specified and directed by Engineer-in-Charge.
M & L for providing & fixing of factory made Fibre glass Reinforced Plastic (FRP) "chajja"- 4mm thick of "fibreways" brand in required colour, size and design made by Resin Transfer Moulding (RTM) Machine Technology available with laminated single piece, having smooth gradual slope curvature for easy drainage of water and duly reinforced by 2 Nos vertically and 1 No horizontally 50x2mm thick MS Flat with 12mm in built hole for grouting on the existing wall along with the 50mm flanges duly inserted and sealed in the wall complete in one single piece casted monothically including all necessary fittings. Molded with unsaturated Polyster resin as per IS: 6746 duly reinforced with fibreglass chopped strand mat (CSM) as per IS: 11551. Available with protective gel coat U/V coating on top for complete resistance from the extreme of temperature, weather & sunlight complete all as specified and directed by Engineer-in-Charge. Make : FIBREWAYS/Equivalent as approved by GE
Removal of existing water proofing treatment of the roof, cleaning with wire brushes etc including demolition of PCC padding of any description and in any position. Note :- Work to be carried out above 14th floor.
M & L for Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) mixed with Shali Plast LW+ of STP/Pidilite URP of Dr. Fixit or Equivalent and appoved as per manufactures instruction. Before laying concrete surface shall be cleaned and a bond coat of slurry with Shali Crete URP (of STP) or quivalent with cement to be applied. Alll cracks in slab to be openend in 'V' groove and filled with Shali Fix RMC a Polymer Morter of STP/ equivalent complete all as specified and as directed. Note :- Work to be carried out above 14th floor.
M&L for 20mm thick rendering in CM 1:4 with the addition of Shaliplast LW+ @ 200ml per bag of cement on fair faces of brick or concrete surfaces complete all as specified and directed by Engineer-in-Charge. Note :- Work to be carried out above 14th floor.
M&L for protecting the roof including parapet wall with water proofing coating ,complete as specified below: (a) Clean the surface and apply one coat of primer (STP Shali Urethane BTD diluted in water in 1:1 ratio and applied @ 400 gm/sqm OR Dr, Fixit primeseal diluted in water in 2:1 ratio and applied @ 7-8 sqm/ltr) and allows to dry for 6 to 8 hrs. (b) Apply first coat of water proofing coating over primer surface (Shali Urethene BTD with non butuminous bleding of STP Ltd. @ 1 Sqm/Ltr without dilution OR Dr Fixit New Coat without any dilution @2 Sqm /Ltr) (c) Lay Non woven fiber glass mesh (Reinforcement of Shali Geo Text 40/50 gsm of size 2.5mm x 2.5mm) or equivalent with overlap of 50 mm on both direction while the first coat is still wet. (d) Apply second coat of water proofing coating as per manufactures instruction after 6-8 hrs of drying of first coat. (e) Apply third coat of water proofing coating (as per manucturer instruction) after 6-8 hrs of drying of second coat The total thickness of 1 to 1.2mm must be achieved after 7 days of air cure.Note : (1) The colour of each coat shall be as directed by GE. ( 2) The work shall be carried out by aithorised applicator only (3) Water proofing to rain water spouts to be done as per manufacturer instruction
Treatment of sunken floor slab comprises of the following specifications and all as specified (i) M&L for cleaning of the sunken /lowered portion of the RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chiesel out any mortar sticking to the surface and brooming / washing completely. 40 mm avg thk pcc 1:2:4 type B-0 using 12.5 mm graded aggregate as in padding conc to achieve proper slope including 50 mm dia 350 mm long medium grade GI pipe spouts with wire guage on inside mouth to be fixed (ii) Rendering of uneven surfaces with 6 mm thick CM 1:4 mixed with integral WPC @3% of weight of cement consumed. fill it with water and check dampness and seepage. where dampness and seepage noticed nozzles shall be fixed and grouting carried out( WPC shall be msrd & paid separately) (iii) All junctions points of side walls where CI/GI pipes are passing through shall be sealed with epoxy putty (iv) After drying putty wash the slab and sides of sunken portion with water and make it clean and clear. (v) M&L for applying two coat of polymer modified cementious water proofing coating as per manufactures instructions to bottom and vertical sides up to finished flooor level +100 mm height. The thickness of two layer shall be 1 mm. When the second layer is still sticky , coarse sand spry shall be carried out or vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20 mm thk cm 1:4 mixed with integral WPC 3 % of cement consumes as per manufacures specification including rounding of corners and junctions sloping towards spout ( WPC shall be msrd and paid seperately Note:Test the water proofed area (ponding test) by filling water for atleast 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. the treatment shall be carried out by authorised applicators of chemicals. (vii) All pipes laid in sunken portion shall be covered with 50 mm thk PCC 1:3:6 all around after painting with anticorrossive black japan paint (viii) Height up to and including 14 th floor Note- All works of structural items 1 to 23 shall be carried out upto G+14 floors including scaffolding, barricading and safety net as required and directed.
M&L granite (of any type) slab 18 to 20mmthick machine cut,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete for kitchen plateform etc.
Height upto and including 4th floor.
5th floor to upto and including 8th floor.
9th floor to upto and including 12th floor.
13th floor to up to and including 14th floor.
Taking up or down GI tubing including all fitting and fixtures fixed to wall in existing position at location and remove from the site complete all as specified and directed by Engineer-in-Charge. :-
15 mm bore
20 mm bore
25 mm bore
50 mm bore
80 mm bore
Supply and Fixing of steel water tubing, galvanised, Medium grade with all fittings in shafts such as nipple, union, socket, elbow, bends, fixed to wall including necessary & capacity up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/on wall and making good the disturbed surfaces complete all as specified and directed by Engineer-in-charge.Note Work to be carried out in high rise buildings plain wall or in shafts or in terraces or inside the flats for cutting the existing GI pipe line and replace the same with new GI pipe in short piece of full length complete all as specified and directed by Engineer-in-Charge.
15 mm bore
20 mm bore
25 mm bore
50 mm bore
80 mm bore
Supply and fix in repairs Valve, stop, screwed, supplied and Installed complete for size 15 mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs Bib taps,cast copper alloy with crutch or butterfly handle,screwed down,screwed for iron pipe or for brass ferrule and fixed of size 15 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC (LLDPE) rectangular loft tank with lid of net capacity 275 litres with gross capacity of tank at least 5 percent in excess of minimum net capacity including 03 Nos adaptor with water for inlet / outlet overflow as per manufacturer instruction and over all dimension as 995-1200 mm length, 620-820mm width, 285-485mm height, 300mm internal dia of hand hole, minimum wall thickness 2.75mm, complete all as specified and directed by Engineer-in-Charge. Note :- The weight of tank shall not be less than 11.0 Kg excluding lid .
Supply & Fix in replacement of PVC profile suitable for 275Ltrs PVC Loft tank including fixing of aluminium channel around the profile complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs in existing line, gun metal gate valve with iron wheel head screwed both ends for iron pipe including fittings i.e. union, socket etc complete all as specified and directed by Engineer-in-Charge with following sizes :- Make : HM/Zoloto/Leader ( ISI marked )
50 mm bore
80 mm bore
Supply and fix shower rose CP 125mm dia swivel suitable for 15mm bore GI tubing complete all as specified and directed by Engineer-in-Charge.
S & F in repairs of Bronze, pressure, reducing valve screwed ends for 25 mm bore GI pipe, suitable for a maximum inlet pressure of 20 Kg/cm2 reduced to 0.5 to5.5 Kg/cm2, valves incorporates inherent design advantages like noise free working, an metal construction, reversible double re-inforced food grade EPDM rubber (Colour coding Black) Diaphram cover, stainless steel bolts etc valve are calibrated for a maximum inlet pressure of 20 Kg/cm2. Make- Hawa/Leader/ Zoloto complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair/Rolled mild steel Gde 410-0 of Fe 310-0 Joist channel, angle of the steel on fixed independently without connecting plates etc (cut to ordinary length i.e.. within 20mm of the length indicated) including cutting holes in to or through brick wall built in cement mortar and making good in cement mortar (1:3) or cement concrete 1:2:4, type B-1, as required with preparation of newly steel iron surfaces of any description over 10 cm in width a girth not otherwise described and applying two coats of synthetic enamel point over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
S&F SMC panel tank of capacity 10000 Ltrs of length 2m x 2m x 2.5m made up of top and bottom of hot pressed moulded UV stabilized panels of size 1m x 1m and internal roof support of plastic with corner glass, manhole, sealant and nut and bolt of hot dip galvanised with external reinforcement of steel with anticorrosive paint and connection for inlet/ outlet and overflow of GI flanged type with air vent and water level indicator without glass of FRP. Make : Sintex Code No GS-PT-010-S2.5 or equivalent model of make in M/s BT composite Ltd / M/s Mahindra composite Ltd. NOTE: Rate quoted shall deemed to be inclusive of internal and external ladder made out of GRP/ Pultruted Section and necessary modifications to RCC foundation. MS supporting channels and necessary PVC profile.
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of ceiling, walls, floors complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLS, passing through PVC casing caping including accessories and fixing of modular PVC boxes for provision of mounting modular switches, switch socket, fan regulator etc, as directed by Engineer-in-Charge including one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLS earth wire and connected to earth dolly for the following:- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/ fan/ E'fan point controlled by one way switch
One light point controlled by two way switch.
One bell point controlled by one push button on the same board with other switches or independent.
One 3 pin socket outlet, 5 Amps on the same board with other switches.
One 3 pin socket outlet, 5 Amps, independent
All as per item above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch complete all as specified and directed by Engineer-in-Charge.
S & F modular switch piano, 1 module, flush type, single pole, one way 6 Amps, 240 Volts. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena) and complete all as specified and directed by Engineer-in-Charge.
S & F modular switch piano, 1 module, flush type, single pole, one way 16 Amps, 240 Volts. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena) complete all as specified and directed by Engineer-in-Charge.
S & F modular switch piano, 1 module, single pole, two way 6Amp. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena) complete all as specified and directed by Engineer-in-Charge.
S & F modular socket, 6A -2/3 pin combined 2 module, flush type, ISI marked, 240 Volts, all as specified. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
S & F modular socket, 6/16A -2/3 pin combined 2 module, flush type, ISI marked, 240 Volts complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
S & F modular stepped type (5 step) electronic fan regulator, 2 module, 230 volts ISI marked and connecting up complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
S & F ceiling rose surface bakelite 65x50 mm with 3 terminals complete all as specified and directed by Engineer-in-Charge. Make: Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC box of 8 module for mounting of modular switches including blank plate for blank module complete all as specified and directed by Engineer-in-Charge. Make- Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
All as per Item above but of 4 module.
All as per Item above but of 3 module.
All as per Item above but of 2 module.
All as per Item above but of 1 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 2 module.
S&F modular white cover plate with frame, 1 module.
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge. Make: Anchor/Crabtree/Legrand.
S&F Retrofit LED lamp 7 Watts complete all as specified and directed by Engineer-in-Charge. Make : C&S, Ordering No :LTHPLEDLAMP7W/B22 or eq in Bajaj/Havells/ Philips/Wipro.
S & F modular bell push, flush type, 5Amp shall confirm to IS-3854 of 1988, 240V complete all as specified and directed by Engineer-in-Charge. Make : Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
S & F bell, ding dong AC 230 Volts, single pole complete all as specified and directed by Engineer-in-Charge. Make : Legrand (Britzy)/Anchor (Roma)/Crabtree (Athena)
Taking down unserviceable FTL and supply and fix slim LED integrated batten of 20 watt 4 ft cool day light with powder coated CRCA decorative patti prewired complete with two Nos of PVC box of size 75 x 75 x 20mm for mounting light fittings complete all as specified and directed. Make of light fitting C&S cat part No LTTB4F2-0WLEDEW or BN 021C LED 20S PSU CW GR S2 of Philips or BCLSB20 WH of Bajaj
All as per item above but slim LeD integrated batten of 10 watt 2 ft complete. Make of light fitting C&S cat part No LTTB2F10WLEDEW or BN021 LED 10S 6500 PSU GRS1 of Philips or BCLSB10WH LED of Bajaj
Taking down unserviceable FTL/Bulk Head fitting and supply and fix Bulk head fitting IP-43 with die cast aluminium housing, heat resistant glass and galvanised wire guard and pin type holder with 9 Watt LED lamp ding replacement of old unserviceable ceiling rose with earth terminal connection, 3 terminal/PVC/Polycarbonate, isolated body. . Make of Bulk head- Halonix, Cat No- HBH0110CFMO or BJDB100BC or BJDB100BC of Bajaj or equivalent in CG/Surya/ Wipro/C&S.
Taking down old MCB DB any way, any type complete all as specified and directed by Engineer-in-Charge.
M&L for sheet metal enclosure for DBs when MCB to be used single phase 8 way, double door, arclic door, 240V having Din rail, Neutral & Earthing bar, IP 43 - IK 09 complete all as specified and directed by Engineer-in-Charge. Make - LEGRAND Cat part No: 507611 or its equivalent in Siemens/ Hagar/ Schneider.
S & F MCB SPN, up to 32 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge. .Make - LEGRAND Cat part No: 408612 to 17 or its equivalent in Siemens/ Hagar/ Schneider.
S & F MCB, single pole, upto 32 Amp, 10 KA, 230 Volt complete all as specified and directed by Engineer-in-Charge. .Make - LEGRAND Cat part No: 408590 to 95 or its equivalent in Siemens/ Hagar/ Schneider.
M&L for resaddling of existing submain/LT cable with suitable size PVC/Steel clamps after taking down and removal of existing rusted/broken clamps complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with PVC insulated, PVC sheathed, armoured, FRLS 1100 V grade, 2 core 5 sqmm stranded copper conductor with GI wire 1mm for earthing protection fixed on wall roof/duct complete and connecting from meter to DBs with glands including taking out existing damaged cables complete all as specified and directed. Make Polycab/Plaza/Havells/Finolax
S&F ceiling fan 1200 mm sweep, 230 V, 50 Hz, BEE rating and energy saving, hanging on ceiling and connect with copper conductor multi stranded 3 core wire of size 14/0.0076 including taking out old US one. Make - Havells model No. ES-50-5 or equivalent to Khaitan/ CG/ Havells. Note : Old U/S C/Fan deposit to MES store.
Taking down deterioted louvers from site and supplying and fix new louvers fixed type made out of 16SWG GI sheet with horizontal ventilation machine pressed cutted ventilation suitable for 300mm sweep exhaust fan complete all as specified and directed by Engineer-in-Charge.
Taking out U/S Exhaust Fan & S&F in repair ventilation fan, 4 blade, heavy duty, double bearing, 230 V, 50 Hz, 300 mm sweep having power input 70 W, speed 1440 RPM, with protective bird guard including connection as required at site with flexible copper cable complete all as specified and as directed by Engr-in-Charge and as per Hevells model-VENTIL AIR DB or equivalent in Khaitan/USHA /Almonard. Note : Old U/S Exhaust Fan deposit to MES store.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, of size 2.20 x 1.60 x 0.45 mtr made of 1.6mm thick CRCA sheet weather, vermin proof factroy fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 250 Amps rated bus bar, top and bottom cable entry including disconnecting cable connections and electronic meters from old meter cabin panel and fixing/connecting in new insalled panel with provisions of thimble/lugs and necessary farmwork and PCC foundation including shifting of existing panel if any making arrengement for fixing of panel and making good to disturbed surface as directed comprising of the following :-
Taking out old broken air termination, single pointed aluminium rod of any dia fixed over the GI Tube with the clamps and Material & labour for CPT Cirprotec CPT-L ESE lightning rod with stainless steel body type advance lightning protection system in compliance with standard NFC 17-102 & UNE 21186-96, working on the principle of early streamer emission technology which will offer level 1 protection for up to 42 mtrs radius when mounted on the RCC concrete base on building at a height of 4.5 mtrs from the place to be protected including taking out old, U/S lightning rod complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or approved by GE.
Supply and erection of mounting structure of 4.5 mtrs height with base plate suitabe for roof mounting on RCC concrete base on building including taking out old, U/S mounting structure complete all as directed by Engineer-in-Charge. Make- NIMBUS-JEF Techno or approved by GE.
Taking out old, broken Aluminium strip of size 25 x 3mm fixed on walls/roof top with saddles and screws complete and Supply & fixing aluminimum strip of size 25x3 mm with of single core PVC insulated and unsheathed cable with copper conductor in and including heavy duty PVC conduiot fixed with screw on wall and using cable size 1x50 Sqmm 1100 Volt grade stranded copper conductor after taking out old, U/S earthing strip complete all as specified and as directed.
Supply and fixing 4 digital electromechanical lightning even counter in weather proof resistance including taking out old, U/S copper strip complete all as directed by Engineer-in-Charge.
Taking out old, broken/unsrviceable earth testing point of any type complete and Supply and fixing test link box for each downconductor in order to disconnect the earth termination system to enable measurement of resistance.
Taking out old, unsrviceable earthing complete with earting material.and Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE.
Supply and replacement, installation, testing & commissioning of Micro processor based 2 wire fault tolerant loop, required loop networkable type 5 Loop (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFFrespective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel shall support 24 zones Addressable 2 way Talk Back fire fighter communication, in case of emergency. The panel shall have ability to get integrated with PA System for zone wise annoucements. The panel shall support both Loop Powered & conventional Notification devices for emergency responses. the Panel shall support Auto learn feature. The panel should support networking upto 99 panels with maximum distance of 12 Km between 1 & last & 1.5 KM between adjacent panels on RS485. Tha Panel shall support IP connectivity if requred to connect on LAN or WAN network. the panel shall support BMS connectivity through Bacnet/Modbus moduels. The Panel Shallbe Sheet Steel Painted, selaed to IP30. The Panel Shall have 24 Zones with Individual LEd Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 48 hours with battery charger complete as required.and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge , Voice Alarm controller with USB, MP3, AM/FM player )with 1000 watts Power Amplifier.
Supply & fix in repair fire hydrant landing valve type A (single head outlet) of 63 mm dia conforming to IS 5290
Supply & fix in repair fire hydrant landing valve type A (Double head outlet) of 63 mm dia conforming to IS 5290
Supply and fix in repair hose box for keeping 2 Nos hose pipe of length 15 meter each, branch pipe.nozzle, coupling etc of MS sheet of Thickness 2.0 mm
Supply and fix in repair 63 mm dia gun metal branch pipe with 12.5 mm nozzle conforming to IS 903
Supply and fix in repair hose reel of 20 mm dia and 30 meter length conforming to IS 5132
Supply and fix in repair branch pipe 25 mm with nozzle of 20 mm dia for hose reel conforming to IS 8090 of lenth 15 m.
Supply and fix in repair 63 mm dia 15 meter long hose conforming to IS 636 complete with male and female coupling conforming to IS 903
Supply and fix in repair fire hydrant stand post with provn of single outlet conforming to IS 908
Supply and fix in repair Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric / Optical with base with self built intelligence as per IS: 11360
Supply and fix in repair Addressable manual call point resettable type.
Supply and fix in Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 450 LPM discharge
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 0.5 sq mm ,5 core, 1100 Volts grade.Make : Kirloskar/RSB/Beacon/Crompton Greaves
Supply ande fix three layer PVC Storage tank of capacity 5000 ltr .inclunding 2 Nos niple and neccessary Foundation work .
Supply and fix in repair MS pipe 100mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer Note for similar items to be given :- (i) In case of similar items with different quoted rate are observed, the lowest quoted rate amongst all shall be considered and amount will be accordingly amended. The tenderer shall be note the above requirement & shall have no claim on this account (ii) The work is to be carried out at any height and rate quoted shall be deemed to be included necessary scaffolding and safety measures of labours as per latest labour laws
AGRAWAL ASSOCIATES
Idustrial products India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .