Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical Civil Contractor, ineligible |
Tender Value
₹6.9 L
Closing Date
15 Jan 2022, 4:00 pmClosed
Executive Engineer, ED-3rd srinagar
Office of Executive Engineer, ED-3rd srinagar
Creation of 100KVA Sub-Station along with its HT-LT network at Shah Avenue Colony T.K College, Srinagar falling under the jurisdiction of ESD Zainakote, ED-3rd (Turnkey Basis)
2021_PDD_155352_1
ED-III /76 of 2021-22, Dated- 29-12-2021
Open Tender
Electrical Works
Turn-key
15 days
Office of Executive Engineer, ED-3rd srinagar
Refer SBD, Technical Specification, Drawings
6 documents required · 6 mandatory
₹500
Executive Engineer, ED-3rd srinagar
Exempted
20 Jan 2022
29 Dec 2021
17 Jan 2022
29 Dec 2021
15 Jan 2022
1 Jan 2022
30 Dec 2021 - 15 Jan 2022
Amount
Creation of 100KVA Sub-Station along with its HT-LT network at Shah Avenue Colony T.K College, Srinagar falling under the jurisdiction of ESD Zainakote, ED-3rd (Turnkey Basis)
Supply, Installation, Testing & Commissioning of 100 KVA,11/0.433,3 phase Distribution Transformers with Bimetallic Terminal Connectors Energy efficient Level-2, (Al. wound) ONAN, Filled with T.Oil as per IS 1180 Part-I of 2014 (including SL Clamps, Jumpers including integration with system). (As per the Specification)
Supply, installation, testing and commissioning including transportation, loading and unloading of Gapless Surge Arrestor, 9 kV, 10 kA, Lighting Arrestor Set Heavy duty with Polymer Housing, Station type conforming to IEC-99-4 Capable of withstanding Maximum continuous operating voltages (M.C.O.V)
Supply, installation, testing and commissioning including transportation, loading and unloading of 11KV 200 Amperes, Triple pole switches Gang Operated (G.O. Set) conforming: IS-2544, IS: 5340 (Part-III) and SS: 9921 (Part-I -V)
Supply, installation, testing and commissioning including transportation, loading and unloading of 11 KV Horn, Gap (fuse 3-phase 200A) as per Relevant IS.
Supply, installation, testing and commissioning including transportation, loading and unloading of 185 mm² (2Ckt inclusive of total length) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type including Aluminum lugs. (Havells, Polycab, Gloster, 3M, paramount/equivalent make).
Supply, Installation, Testing & Commissioning including digging/excavation up 1.5 meter deep for planting of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300 mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, Installation, Testing and Commissioning including Transportation, loading Unloading of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, fabrication and fixing including Transportation, loading Unloading of of G.I Channel Iron / Angle Iron /Flat/F-tops of sizes including clamps/Collars 50 x 6 mm
Supply and fixing of GI Nuts and Bolts full thread of sizes Galvanized as per IS
Supply, Installation, Testing & Commissioning of Earthing of Substation-Excavation of earth pit of dia 650mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 75mm*10mm & 50mm*6mm for connection of transformer body, G.O Set & lightening Arrestor (Including Baby Insulators, if required) as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials & earth chamber made of brick masonry with RCC slab cover.
Supply, Installation, Testing and Commissioning of including Transportation, loading Unloading of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply, fabrication and Fixing of Danger Plate With Clamps as per Standards wih writing in English & Urdu.
Supply, Installation/fixing including Transportation, loading Unloading of Anti-Climbing Device with Clamps
Supply and Painting of poles with one coat of Red oxide Primer and two coats of Aluminium Paint
Supply and fixing of PG Clamps/wedge Connector
Providing of material & Laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole
Supply, Laying, stringing/Installation, testing and commissioning of 30 sqmm ACSR Conductor as per IS.
Supply, Laying, stringing/Installation, testing and commissioning of 50 sqmm ACSR Conductor as per IS.
Supply, Installation, Testing & Commissioning including digging/excavation up 1.5 meter deep for planting of S.T. poles 8 Mtr. Long Pole ST-410 SP15 , IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5 ms (SP 15).Top plate 3 mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
Supply, fixing, testing and commissioning of 16KN Polymer Shackle including GI U-Clamp for Shackle insulators
Supply of material and carrying Earthing Complete of ST Pole by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing of material & Laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole
M/S BUDOO ELECTRICALS AND SUPPLIERS
M/S ROYAL ELECTRICAL MECHANICAL and SUPPLIERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .