| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.6 L+₹3.3 L (15.4%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not approved for opening of Cover-2 due to DD not uploaded |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Nov 2022, 6:00 pmClosed
CWE NO 2 DELHI CANTT-10
HQ CWE NO 2 DELHI CANTT-10
PERIODICAL SERVICES TO COMPOUND WALL AND EXTERNAL SERVICES AT NOIDA UNDER AGE(I) CG NOIDA
2022_MES_557279_1
CWE/NOIDA-32/2022-23
Open Tender
Civil Works
Item Rate
180 days
AGE (I) CG NOIDA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) CG NOIDA
₹60,000
Yes
11 Jan 2023
12 Oct 2022
12 Nov 2022
12 Oct 2022
10 Nov 2022
28 Oct 2022
Amount
M&L for preparation of old decoreated external wall / Ceiling surface of existing treatment by scrapping with TruCare Wall Sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7”/9” to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible up to 8 storey bldg complete all as specified and all as directed. 1. Each stage of prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for preparation of old decoreated/undecoreated external wall / Ceiling applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to 8 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean shall be allowed.
Taking down cement plaster on brick walls, or stone walls / ceilings etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean shall be allowed.
M&L for 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to G+7bldg including scaffolding complete all as specified and directed.
M&L for 5mm thick ready mix cement plaster ceiling / chhaja with bulk density 1.4 to 1.70KG per ltr water ration 17 to 19% by weight with compressive str as per IS 4031 part-VI applied as per the manufactore instr incl necesaery cement screed and prepartion of surface to received ready mix plaster up to G+7bldg including scaffolding. complete all as specified and directed.
M&L for preparation of newly plaster surface of wall / Ceiling surface applying two coats of weather proofing exterior acrylic emulsion paint by spray gun/ spray machine incl one coat of primer up to 8 storey bldg including scaffolding complete all as specified and all as directed by Engr- in-charge. Note :- 1. Each stage for prepration of surfaces shall be got approved from AGE(I) before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for preparation of old plaster surface of wall / Ceiling applying two coats of cement base paint by spray gun/ spray machine up to 10 meter height complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for preparation of newly plaster surface of wall / Ceiling surface applying Two coats of Oil bound distemper over one coat primer by spray gun/ spray machine up to 8 story bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Each stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for Guniting work in side and soffits of slabs, chajjas, fins,facias, parapets ,columns and beams etc complete including necessary scaffolding, shuttering at any height upto G+7storey buildings including removing of small trees shrubs etc all as specified the following :- (i) chipping of spalled and loose concrete/plaster work and cleaning rust from re-inforcement by steel wire brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry (ii) Applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement (iii) Applying a layer of bonding coat of a layer of epoxy adhesive on complete exposed surfaces of concrete (iv) Guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions (v) Applying 5mm thick cement plaster in CM 1:3 over gunite surfaces to give an even uniform and smooth finish to match with the existing surface. Note: steel welded mesh to be welded with the existing reinforcement. The cost of labour/machinery work and all the material as mentioned above is deemed to be included in the quoted rate.
M&L for preparation of old decoreated/undecoreated Internal wall / Ceiling applying two coats of Oil bound distemper by spray gun/ spray machine up to G+7 storey bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. Note rate quoted up to G+7 bldg including scaffolding
M&L for preparation of old plaster surface of Wall / Ceiling surface applying two coats of white wash by spray gun/ spray machine up to G+7 bldg complete all as specified and all as directed by Engr- in-charge. Note :- 1. Stage for prepration of surfaces shall be got approved from GE before applying the finishes. 2. Material shall be procured from manufacturer and work shall be got executed through authorised applicator. 3. Item no 1.00 to 11.00 The work pertaining to periodical services & Water Proofing shall be executed from authorized applicator through manufacturer of which the materials .i.e. Paint, Distemper, Primer,White wash,Exterior emulsion paint,Cement base paint, Putty etc. is proposed to be used by the contractor and approved by Engineer-in-Charge. 4. The contractor shall upload along with the documents under cover-I, ‘Memorandum of Understanding’ (MOU) with Auth aplicator & 5 yrs warrenty. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for Preparation of old painted surfaces of wood surfaces of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying two coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and directed. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
M&L for Preparation of old painted surfaces of steel of any description over 10 Cm width or girth by applying sand paper etc.for proper preparation and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks all as specified and directed complete all as specified and directed. Note: rate quoted by contractor deemed to be included scaffolding up to G+7bldg and No others mean of painting shall be allowed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wallscomplete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequalnd, 110 mm bore with access door complete all as specified and directed.
S&F in repair PVC (SWR) cowl, 75 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) cowl, 110 mm borecomplete all as specified and directed.
Demolition of (unreinforced) cement concrete of any description and in any position not otherwise specifically provided for and removing rubbish off the MD land complete all as specified and directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) as in Coping,benching,anchorage blocks, lintels upto 1.5m clear span,cills, steps, sesmic & other similar bands, plinth course, lacing course, parapets & ralling upto 60 cm in height, coping, kneelers, apex stones, bed plates, kerbs not provided for water trought & the like including weathering, slightly rounded or chemfered angels & throating complete all as directed and specified.
Demolition of brickwork built in cement mortar.
M&L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and as diredted.
Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
Demolition of mud phuska in roofs any thickness including plastering and leeping(whether full thicknessremoved or only a part thereof) complete including removal outside of MoD land complete all as specified and directed.
M&L 40mm thick Plain cment concrete B-1 1:2:4 (using 20mm graded stone aggregate surface even and smooth without using extra cement complete all as specified.
M&L for water proofing treatment to RCC roof slab incl parapet as under (a) Applying bituminious primer conforming IS 3384 1965 @ 0.50 Kg/Sqm over cleaned and dry roof surface incl parapet. (b) Laying one layer of APP based polymeric membrane, 3mm thick, weight not less than 3.6 Kg/Sqm reinforced with non woven polyster fiber reinforced (wight not less than 150gm/Sqm) sealed by torch application with a minimum overlap of 100mm and 75mm at end and side of polymeric membrane all as specified and as directed by Engrineer-in-charge.
M&L for 40 mm thick brick tiles laid, and joints grouted flush in cement mortar (1:3) mixed with 5% of curde oil by weight of cement complete
All as per item 29.00 here in above but except brick tiles.
Sanjay Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .