Loading…
Loading…
Tender Value
₹4.0 L
EMD Value
₹8,040
Closing Date
21 Sept 2026, 6:00 pm6d left
GE (WEST) JRC
KABIR ROAD JALANDHAR CANTT
Provn of nine deep freezer for Offrs mess, JCO mess and Cook house of 26 Punjab and one refrigerator and 02 x Split AC at Dograi Guest room under GE (West) JRC
2026_MES_786467_1
GE/JAL(W)-69/2026-27
Open Tender
Civil Works
Item Rate
180 days
JALANDHAR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (WEST)
₹8,040
Yes
21 Sept 2026
26 Aug 2026
28 Sept 2026
26 Aug 2026
21 Sept 2026
9 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for (concealed Type) point wiring including necessary chase cutting of wall for one light/fan/call bell point with 2.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 2.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit medium grade with all accessories and sunk GI box for mounting of fittings like switch, socket and fan regulator and making good the disturbed surfaces as per the existing complete all as specified and as directed by the Engr-in-Charge.
Note:
A. Red colored cable shall be used for live connection; black colored cable shall be used for neutral connection and green colored cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
B. The Rate of point wiring includes the following: -
(i) Copper standard wire.
(ii) PVC conduit with accessories.
(iii) Chase cutting. | 10 | Point | - | - |
| 2 | S & F socket combination, 6 pin, 15 amps, flush type, multipurpose, 230 / 250 volts, AC with ISI marked complete all as specified and directed. | 10 | Each | - | - |
| 3 | S & F switch Piano 15 Amps, flush button type, multipurpose, one way, 230 / 250 Volts, AC with ISI marked complete all as specified and directed. | 10 | Each | - | - |
| 4 | Supply and fixing deep freezer, metal-top type, having a gross storage capacity of not less than 300 litres, with double-door/twin-lid arrangement, suitable for operation on 230 V, 50 Hz, single-phase AC supply, complete with compressor, condenser, thermostat/temperature control, suitable refrigerant system, insulated cabinet, internal storage arrangement, lockable lid/door, castors/legs and all standard accessories and fittings required for proper operation. The item shall include transportation, shifting, positioning, installation, testing and commissioning, complete with all necessary materials, labour, tools and accessories, all as specified and as directed. | 9 | Each | - | - |
| 5 | Supply and fixing refrigerator Double Door Refrigerator with smart invertor compressor, smart diagnosis to troubleshoot issues, auto smart connect, toughned glass shelves that can carry heavy load without any spillage, frost-free/direct-cool type as specified, electric driven, single-phase, 230 V, 50 Hz AC, having gross storage capacity of 310 litres, with maximum BEE Star energy rating, suitable for domestic/general institutional use, complete with compressor, condenser, thermostat/temperature control, insulated cabinet, adjustable shelves, vegetable/food storage compartments, door racks, internal lighting, suitable refrigerant system and all standard accessories and fittings required for proper operation. The item shall include transportation, shifting, positioning, installation, testing and commissioning, complete with all necessary materials, labour, tools and accessories, all as specified and as directed. | 1 | Each | - | - |
| 6 | Supply and installation hi wall split units indoor/ outdoor complete with cordless remote control unit and with in built heating and cooling arrangement and digital invertor twin rotary of capacity 2 TR with max BEE rating available complete all as specified and directed. | 2 | Each | - | - |
| 7 | Supply, installation & commissioning MCB Load Distribution board TPN 4 way double door, for mounting DP/ SP/TP/ MCBs/MCCBsas Incoming / outgoing, factory made, confirming to IS, fabricated out of CRCA sheet complete all as specified and directed. | 1 | Each | - | - |
| 8 | Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TPN 40 To 100 AMP complete all as specified and directed. | 1 | Each | - | - |
| 9 | Supply and fixing amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning SP 6-32 AMP complete all as specified and directed. | 2 | Each | - | - |
| 10 | M & L for sub main wiring with PVC insulated and unsheathed cable 4 x 10 sqmm with multi stranded copper conductor , FRLS type cable drawn through and including PVC concealed conduit not less than 25mm in size complete with all accessories alongwith provn of 10 sqmm PVC insulated and unsheathed ,multi stranded copper conductor, FRLS type cable as earth wire. (Four runs of cable and one run of conduit shall be measured as one length) complete all as specified and directed. | 30 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_881339.xls
BOQ • 0.26 MB
TenderDocuments69.pdf
Tender Documents • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .