Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹15.1 L+₹43,160 (2.94%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹15.8 L+₹1.1 L (7.35%)Rejected-Finance | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹16.2 L+₹1.5 L (10.3%)Rejected-Finance A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L4 | Rejected-Finance NOT L1 |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
22 Feb 2021, 6:00 pmClosed
GE FATEHGARH
GE MES FATEHGARH
ROOF TREATMENT,SUNKEN TREATMENT AND CONNECTED MISC WORK TO MD ACCN UNDER AGE B/R-II SUB DIVISON AT FATEHGARH CANTT
2021_MES_415601_1
GE/FAT/ET-31 OF 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
GE MES FATEHGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE FATEHGARH
₹38,000
Yes
17 Apr 2021
23 Jan 2021
24 Feb 2021
23 Jan 2021
22 Feb 2021
7 Feb 2021
23 Jan 2021 - 6 Feb 2021
Amount
Demolition of brick work built in cement mortar or cement lime mortar etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks straight or curved on plan exc 6m mean radious built in CM 1:6 etc complete all as specified and directed.
Taking down cement plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish of the MD Land complete all as specified and directed.
M&L Rendering 15mm thick on Brick / Concrete Surfaces in CM (1:4) finished even & smooth without using extra cement all as specified and directed.
M&L Rendering 15mm thick in CM (1:6) on brick/concrete surfaces, finished even & smooth without using extra cement all as specified and directed.
M&L Rendering 5mm thick on concrete surfaces such as sofit of slab, chajja etc in CM (1:3) finished even & smooth without using extra cement all as specified and directed.
Preparation of Newly Plastered surfaces of Wall and applying Two coats of Oil Bound Distemper over a coat of primer complete all as specified and directed.
M&L Preparation of Newly Plastered surfaces of Ceiling and applying Three coats of White Washing complete all as specified and directed.
Preparation of Newly Plastered surfaces and applying two coat of Cement Base Paint on walls complete all as specified and directed.
Dismantling of roof brick tiles fixed in cement mortar in single layer complete all as specified and directed.
Demolition mud in roofs any thickness, including and leeping(whether full thickness removed or only a part thereof)including tarfelt etc and removing debris by any means outside of defece land complete all as specified and directed
Removing exsiting old plaster/roof treatment surface all as directed by Engineer-in-charge and disposing off out side Defence Land complete all as specified and directed.
Cleaning the surface by roughening, sweeping clean and washing down and applying cement slurry @ 3 kgs/sqm complete all as specified and directed.
M&L cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate as in levelling /slopping course as in sub floors finishing the top surfaces fair and even as in padding of roof complete all as specified and directed
M&L applying water proofing treatment to roof slabwith APP modified polyeric membrane with centre core 100 micron HMHDPE out film 20 micron each having thickenss 3 mm , weight not less than 3.00 kg/Sqm with 100 mm side overlap and 150 mm end lap and laid with following course of descritiopn below:- (a) Applying evenly a coat of bituminous primer conforming to IS 3384-1965 @ 0.50 ltr/sqm prepared surface till the surface is properly impregnated and solvent oil in primer shall be allowded to evaporate completely. (b) Second caot of bonding material using hot blown grade bitumen 85/25@ 1.2 kg/Sqm conformoing to IS 702-1988 over bituminous primer . (c) third course i:e laying APP Modififed polymeric membrane describe hereinbefore with 100 mm overlap in longitudinal direction and 150 mm in traverse direction , (d) Fourth course of bonding material using hot blown grade bitumen 85/25 conforming to IS 702-1988 @ 1.2 Kg/Sqm over membrane. (e) Fifth course is sprinkling a layer of course sand dusting @ 1kg/Sqm as directed.
M&L applying water proofing treatment to roof slab with APP modified polymeric membrane with centre core 100 micron HMHDPE out film 20 micron each having thickenss 3 mm , weight not less than 3.00 kg/Sqm with 100 mm side overlap and 150 mm end lap and laid with following course of descritiopn below:- (a) Applying evenly a coat of bituminous primer conforming to IS 3384-1965 @ 0.50 ltr/sqm prepared surface till the surface is properly impregnated and solvent oil in primer shall be allowded to evaporate completely. (b) Second caot of bonding material using hot blown grade bitumen 85/25@ 1.2 kg/Sqm conformoing to IS 702-1988 over bituminous primer . (c) third course i:e laying APP Modififed polymeric membrane describe hereinbefore with 100 mm overlap in longitudinal direction and 150 mm in traverse direction
M&L for 40mm thick brick tile laid over 15mm thick bedding layer in CM 1:6 and grating and pointing with CM (1:3) with including crude oil 5% of wt of cement complete all as specified and directed.
…..ditto as above but except tiles….ditto…
M&L for PCC 1:2:4 type B1 (using 12.5mm graded stone agg) Providing cement concrete in roof kerbs or mud stops, rounded or cmamfered on edges complete all as specified and directed.
Dismantling of floor hearth or wall tiling any type including cement mortar bedding complete all as specified and directed.
M&L glazed ceramic coloured tiles 350 x 250 x 7 mm th/450 x 350 x 7 mm th thick as in vertical surfaces set and jointed in neat cement slurry and jointed or coloured cement to match etc complete laid over screed bed or bedding layer of mortar CM (1:6) , 15mm thick ,complete all as specified and directed.
S&F Non Skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceedifng 0.11 sqm but not exceeding 0.18 sqm in floors and skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm screed bed in CM 1:4 complete all as specified and directed.
Demolition cement concrete of any description and in any position complete all as specified and directed.
M&L for water proofing treatment to floor and vertical surface of sunken portion complete all as specified and directed with including following :- (a) After demolition of floor and cement concrete remove all loose particles alongwith existing water proofing treatment (any no of layers) with wire brushes a d cleaning the surface with water. (b) Brushing cement slurry with 1.2 kg of cement per square metre duly blended with acrylic water proofing compound. (c) 15mm thick (average thickness) plaster in cement mortar (1:3) mixed with acrylic water proofing compound on sunken surface and wall. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accommodate sump pipe. (d) Brushing cement slurry with 1.2 kg per square metre duly blended with acrylic water proofing compound. (e) Curing the sunken portion with water minium for 48 hours by ponding. Applying APP modified polymeric membrane with centre core 100 micron HMHDPE out film 20 micron each,having thickenss 3 mm, weight not less than 3.00 kg/Sqm with 100 mm side overlap and 150 mm end lap and laid with following course of descritiopn below:- (a) Applying evenly a coat of bituminous primer conforming to IS 3384-1965 @ 0.50 ltr/sqm prepared surface till the surface is properly impregnated and solvent oil in primer shall be allowded to evaporate completely. (b) Second caot of bonding material using hot blown grade bitumen 85/25@ 1.2 kg/Sqm conformoing to IS 702-1988 over bituminous primer . (c) third course i:e laying APP Modififed polymeric membrane describe hereinbefore with 100 mm overlap in longitudinal direction and 150 mm in traverse direction
M&L for Cement concrete Type E2 1:5:10 ( 40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed.
S&F in repairs Vitreous China Squatting Pan “Orissa Pattern” of size 580mm x 440mm, white with, integral foot rests front or back inlets including lime concrete bedding and P Trap complete all as specified and as directed by Engr-in-Charge etc complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (padestal pattern) white including fixing bolts,seat cover and fixtures etc complete all as specified and directed.
S&F in repair for PVC low level flushing cistern 10ltr capacity, with cyphonic action PVC float valve, brackets and 32mm bore PVC flush pipe etc and fixed in repair complete all as specified and directed.
S&F in repair 15mm dia stop valve standard of PTMT any colour screwed,for iron pipe and fixed.(Minimum weight 15mm - 90gms complete all as specified and directed.
S&F in repair 15mm dia bib tap standard of PTMT any colour screwed,for iron pipe and fixed.(Minimum weight 15mm - 90gms complete all as specified and directed.
S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
S & F in repair gun metal,globe or gate valves, 15 mm size wuith iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
S & F in repair gun metal,globe or gate valves, 20 mm size wuith iron wheel head,screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15mm dia CP concealed type with long shank and capstan head for (Bath shower) complete all as specified and directed.
Taking up or down steel tubing and connectipons including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed.
S & F GI tubes medium grade with all fittings fixed to walls and ceiling or laid in floors of 15 mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connectipons including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed.
S & F GI tubes medium grade with all fittings fixed to walls and ceiling or laid in floors of 20 mm bore of pipe complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc.measured separately) complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed up, capacity in 500 Ltrs, hoisted and fixed in position with all fittings and fixtures including float valve 20 mm bore in position complete all as specified in SSR Part-I. include is dismantling of existing water tank etc complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed up, capacity in 1000 Ltrs, hoisted and fixed in position with all fittings and fixtures including float valve 20 mm bore in position complete all as specified in SSR Part-I include is dismantling of existing water tank etc complete all as specified and directed.
S&F 100mm dia GI pipe medium grade as in spouts fixed to parapet walls on roof terrace,incl setting and fixing in cement concrete 1:2:4 and making necessary repairs etc incl removing old pipe complete all as specified and directed.
M/s Moti Babu Agarwal
M/S SRI JAGDAMBE TRADERS
M/S WASEEM KHAN CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .