Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.8 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹12.2 L+₹3.3 L (37.1%)Rejected-AOC 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹13.5 L+₹4.6 L (51.5%)Rejected-AOC | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹14.5 L+₹5.6 L (63.0%)Rejected-AOC | L-4 | Rejected-AOC Other than lowest bidder | |
| 5 | L-5₹15.8 L+₹6.9 L (77.4%)Rejected-AOC | L-5 | Rejected-AOC Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
3 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR REPLACEMENT OF MINOR ACCESSORIES AND SPARE PARTS AT BIRPUR MIL STN UNDER GE KALUCHAK
2022_MES_516023_2
GE/KC/NIT-64/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Kaluchak
₹30,000
Yes
25 Jul 2022
6 May 2022
10 Jun 2022
6 May 2022
3 Jun 2022
20 May 2022
6 May 2022 - 13 May 2022
90 days
Amount
Dismantling of totally damaged portion of the exposed duct insulation consisting of sand cement plaster chicken wire mesh glasswool etc and disposing of the same within 100mtrs, complete all as specified & directed by Engineer-in-Charge.
Scrubbing of bare GI duct with steel wire brushes ,emery cloth for removing stuck material iron oxides etc and dusting with air blower to make the surface clean, complete all as specified & directed by Engineer-in-Charge.
Rubber/ metal based synthetic adhesive to the so cleaned bare duct and the rubber insulation sheets with brushes including applying adhesive on each surface as per requirement at site, complete all as specified & directed by Engineer-in-Charge.
Nitrile rubber insulation 25mm thick with Alum foil facing as UV protection, cut to size as per duct sizes including covering all longitudinal/ transverse joints with 500 wide alum tape, complete all as specified & directed by Engineer-in-Charge.
Routine checking of complete central AC plant of 3 x 12 TR capacity as required during the contract period, fault detection by OEM/authorised partner of OEM with whom MOU stands signed for smooth functioning of the plant as well as for uninterrupted running all as required at site, complete all as specified & directed by Engineer-in-Charge.
Supply and topping of chiller/ compressor unit (12TR AC Plant) with R-407C refrigerant including leak testing and necessary associated repair works, complete all as specified & directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of microprocessor controllers with scanners/ under voltage/ over voltage protections for chillers including caliberation/ settings as per the requirement of the system of chiller controller for proper safeties like under voltage, overvoltage, low pressure and high pressure complete including taking down old unserviceable controllers, complete all as specified & directed by Engineer-in-Charge. Make: As per OEM
Pressure transducers for suction pressure of compressors including taking down old unserviceable and testing, complete all as specified & directed by Engineer-in-Charge.
Pressure transducers for discharge pressure of compressors including taking down old unserviceable and testing, complete all as specified & directed by Engineer-in-Charge.
Complete overhauling of Delta cooling tower by chemical cleaning of sump, dismantling and servicing of cooling tower strainer, dismantling of cooling tower motor and fan and sprinkaler assembly, descaling of sprinkler pipes and adjustment of sprinkler speed and refitting of motor and fan assembly after satisfactory operation including descaler and replacement of PVC honeycomb fills, complete all as specified & directed by Engineer-in-Charge.
Servicing of condensor water pumps including replacement of impellors and seals, complete all as specified & directed by Engineer-in-Charge.
Servicing of chilled water circulations pumps including replacement of impellors and seals, complete all as specified & directed by Engineer-in-Charge.
Servicing of AHU cooling coil including chemical cleaning with OEM recommended chemical 'scalefoe', complete all as specified & directed by Engineer-in-Charge.
Disconnecting the electric connections of the electric motor 2 HP of the cooling tower blower, taking out the old unserviceable winding wire, cleaning the slots for rewinding, rewinding the electric motor 3 Phase, 415 volts with existing size of super enamelled copper winding wire including allied materials like cotton tapes, glass sleeves, varnishing and assembling the complete motor and testing, complete all as specified & directed by Engineer-in-Charge.
Descaling of condensors with 'scalefoe' 100 chemical by pressure pump, opening of condensor head and rodding with nylon brushes including fixing new gasket, condensors covers and refitting with covers, complete all as specified & directed by Engineer-in-Charge.
V-Belt as per existing for AHU including taking down old unserviceable V-Belt, complete all as specified & directed by Engineer-in-Charge.
Start push button assembly, complete all as specified & directed by Engineer-in-Charge.
Stop push button assembly, complete all as specified & directed by Engineer-in-Charge.
Water pressure gauge 100mm range ( 0 to 75psi) including taking down old unserviceable gauge, complete all as specified & directed by Engineer-in-Charge.
Temperature gauge stem type including taking down old unserviceable gauge, complete all as specified & directed by Engineer-in-Charge.
MCB, triple pole, 63 Amps, AC, 415v, 50Hz, breaking capacity 10 KA, C-curve including taking down old unserviceable MCB, complete all as specified & directed.
MCB, triple pole, 32 Amps, AC, 415v, 50Hz, breaking capacity 10 KA, C-curve including taking down old unserviceable MCB, complete all as specified & directed.
MCCB of capacity 100 Amps, 3 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 125 Amps, 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, including taking down old unserviceable MCCB, complete all as specified & directed.
Contactor, triple pole, 440 volts 4 KW, 20Amps including taking down old unserviceable contactor, complete all as specified & directed.
Contactor, triple pole, 440 volts 15 KW, 32Amps including taking down old unserviceable contactor, complete all as specified & directed.
Contactor, triple pole, 440 volts 22 KW, 40Amps including taking down old unserviceable contactor, complete all as specified & directed.
Voltmeter (0-500V) digital flush type 96mm, square type including taking down old unserviceable voltmeter, complete all as specified & directed.
Ammeter (0-60A) digital flush type 96mm square type including taking down old unserviceable ammeter, complete all as specified & directed.
Ammeter (0-100A) digital flush type 96mm square type including taking down old unserviceable ammeter, complete all as specified & directed.
Over load relay with range (12- 18) Amps including taking down old unserviceable relay, complete all as specified & directed.
Over load relay with range (07- 10) Amps including taking down old unserviceable relay, complete all as specified & directed.
Supply, installation, testing and commissioning of maintenance free lead acid battery, 12V, 180 AH conforming to IS:7372 including dismantling of old unserviceable battery, complete all as specified & directed.
On load change over switch in sheet metal enclosure, 200 Amps, 415 volts, 4 pole, modular type, positive isolation, door interlock & padlock facility, conforming to IS:13947 (Part-3); IEC:60947-3 including all connecting/ jointing materials & taking down old unserviceable change over switch, complete all specified & directed.
MCCB of capacity 160 Amps, 4 pole, 415volt, 50Hz, breaking capacity 25 KA (minimum) or higher, adjustable thermal and fixed magnetic release, complete as per OEM standard design including taking down old unserviceable MCCB, complete all as specified & directed.
MCCB of capacity 200 Amps, 4 pole, 415volt, 50Hz, breaking capacity 25 KA (minimum) or higher, adjustable thermal and fixed magnetic release, complete as per OEM standard design including taking down old unserviceable MCCB, complete all as specified & directed.
Cable jointing kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50-95 sqmm including testing and commissioning, complete all as specified & directed.
XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) of size 120 Sqmm, 3 core with aluminium conductor (multistranded) 11000 volts grade (earthed) connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion and removal of old unserviceable cable, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
Galvanised iron tube 80mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Prakash Trading Corporation
VEE ESS ENGINEERS
KAMAL CONSTRUCTION
Sarbat Construction Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .