Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC L1 BIDDER ACCEPTED |
| 2 | L2₹2.2 Cr+₹44.1 L (24.9%)Rejected-AOC | ₹2.2 Cr+₹44.1 L (24.9%) | L2 | Rejected-AOC REJECTED |
| 3 | L3₹2.3 Cr+₹52.0 L (29.3%)Rejected-AOC | ₹2.3 Cr+₹52.0 L (29.3%) | L3 | Rejected-AOC REJECTED |
| 4 | L4₹2.3 Cr+₹55.0 L (31.0%)Rejected-AOC | ₹2.3 Cr+₹55.0 L (31.0%) | L4 | Rejected-AOC REJECTED |
| 5 | L5₹2.3 Cr+₹57.5 L (32.4%)Rejected-AOC OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹2.3 Cr+₹57.5 L (32.4%) | L5 | Rejected-AOC REJECTED |
Tender Value
₹2.4 Cr
EMD Value
₹4.7 L
Closing Date
11 Jan 2020, 6:00 pmClosed
AGM (E-E)
Civil Airport, Gorakhpur.
ELECTRICAL WORKS FOR DEVELOPMENT OF KUSHINAGAR AIRPORT FOR RCS OPERATIONS
2019_AAI_38680_1
AAI/Kush./Engg.-Elect./2019-20
Open Tender
Electrical Works
Works
60 days
Gorakhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,180
Revenue Collection, Lucknow Airport A/C
₹4.7 L
18 Feb 2020
26 Dec 2019
16 Jan 2020
26 Dec 2019
11 Jan 2020
26 Dec 2019
26 Dec 2019 - 4 Jan 2020
Amount
Wiring for light point/fan point/ exhaust fan point/ call beel point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modulat switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper stranded conductor single core cable etc. as required. (Group C)
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group C)
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS OVC insulated copper conductor, single core stranded cable in surface/ recessed Steel conduit as required.2x1.5 sq.mm+ 1x 1.5 sq.mm earth wire.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS OVC insulated copper conductor, single core stranded cable in surface/ recessed Steel conduit as required. 2x2.5 sq.mm+ 1x 2.5 sq.mm earth wire.
Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS OVC insulated copper conductor, single core stranded cable in surface/ recessed Steel conduit as required. 4x 2.5 sq.mm + 2 x 2.5 sq.mm earth wire
Wiring for power plug with 2 x 4 sqmm FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit along with 1 No 4 sqmm FRLS PVC insulated copper conductor, single core stranded cable for loop earthing as required.
Wiring for light/ power plug with 4 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface. Recessed steel conduit along with 2 nos. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supply and drawing following sizes o FRLS PVC insulated copper conductor, single core stranded cable in the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq.mm.
2 x 4 sq.mm.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Telephone socket outlet
TV antenna socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
4 Module
6 Module
8 Module
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. As required.
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
Supply and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted inclusice of 200 amps tinned copper bus, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing and circuits. (But without MCB/RCCB/Isolator).
4 way (4+12), Double Door, Vertical type
8 way (4+24), Double Door, Vertical type
12 way (4+36), Double Door, Verical type
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V "C" curve TP MCB complete with connections, testing and commissioning etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(1 run of cable)
Supply of 600mm x 600mm recess Mounted LED fixture (38 watt) with CRCA powder coated housing, high efficiency PMMA diffuser complete with electronic ballast, PF≥0.95, THD<10% & surge proctection of ≥ 2.5kv, rated life of L-70@ 50,000 hours having lumen output not less than 3300 Lumens with luminaire efficacy of not less than 85 Lumens / watt with CRI >80, operating range 150V – 270V, 50Hz AC supply, CCT 5700K- 6500K. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. (Similar to Philips CAT No/type- RC366B LED33-6500 PSU OD GR or equivalent)
Supply of 600mm x 600mm recess Mounted LED fixture (32 watt) with CRCA powder coated housing, high efficiency PMMA diffuser complete with electronic ballast, PF≥0.95, THD<10% & surge proctection of ≥ 2.5kv, rated life of L-70@ 50,000 hours having lumen output not less than 4000 Lumens with luminaire efficacy of not less than 110-125 Lumens / watt with CRI >80, operating range 150V – 270V, 50Hz AC supply, CCT 5700K- 6500K. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. (Similar to Philips CAT No/type- RC600B LED40S/865 PSD ACW W60L60 or equivalent)
Supply of Mirror LED Light with heat dissipation capability with Opal diffuser creates optimum light uniformity with minimum glare with integral constant current led driver. It has a system lumen output not less than 1800 lumens with luminaire efficacy of not less than100 lm/W and lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, operating range 150V – 270V, 50Hz AC supply, CCT of 5700K - 6500K with PF≥0.95 and THD must be <10% & surge proctection of ≥ 2.5kv. The luminaire is IP 20 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. (Similar to CAT No. BGSLO SLEEK SURFACE 18 WH RD or equivalent).
Supply of 3W LED bidirectional Exit Signage Light with inbuilt 2hours battery back up. (Similar to Bjaj CAT No.BESL 03 LED DSD WBB Redor equivalent ( Green / Red )
Supply of following sizes of celing fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies hanging shackle, 30 cm down rod and without speed regulator suitable for 230 V/240 V 50 HZ, AC supply confirms to 5 star rating as required complete ( Havells ES 50 or equvl.) (1) 1200 mm sweep.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply of 400 MM, 1250 RPM wall mounting swinging fan suitable for single phase 230 Volt, 50 Hz AC supply complete with motor, capacitor, mounting clamps etc. With all accessories as required complete.
Supply of 900 RPM heavy duty exhaust fan suitable for single phase 230 volt, 50 HZ AC supply complete with motor, capacitor, louvers/ shutters and all accussories as required complete. (I) 300 mm, Sweep with louvers.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard lenght (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable etc. As required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/LED luminaire fittings of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (upto 450 mm sweep)
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings/LED fittings as required.
SITC of 400KVA Oil Type Compact Sub Station (Outdoor type) Supply, Intallation, Testing and Commissioning of distribution network, 11KV 400KVA Oil Type Outdoor Compact Sub Station totally factory assembled (non walk in Type) consisting of 2 way RMU Type, 1 No. 11KV/433V, 400KVA Oil Type transformer, 1 Set of HT-LT PANELS, APFC PANEL ETC as under. Approved Makes of PSS should be-Siemens/Schneider/ABB/ AAI approved make 1.MV COMPARTMENT- 11 KV, 630A, 25KA/1Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271-202.IAC of 20 kA for 1 s for tank and cable box category IAC-AFL . The Switchgear includes the following HV cubicles- The indoor non -extensible SF6 insulated RMU manually operated consist of 1 No. incomer Riser and 1 no. outgoing Vacuum Breakers with self powered relay for protection of transformer . Rated for Voltage 12kV, 630A, 25 KA for 1 sec. a.Rated voltage should be - 12 kV b.Rated power frequenecy voltage be - 28 kV c.Rated lightening withstand voltage -75 KV d.Rated current for Ring main feeder -630 amps e.Rated current for VCB feeder -630amps f.Vacuum Circuil Breaker of RMU should clear minimum 40nos. of dead short circuit operations g.Rated short time cuirrent -25 KA /3sec h.Rated short time making cuirrent -50 KA i.Amdient temp (0deg C to +40 deg C) j.Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFL k.The cicuit breaker feeder shall be self powered/powered by external source and shall be provided with OC + EF protection for transformer and shall have serial port for communication on modbus protocol. l.RMU manufacturere shall have in house NABL accredited testing lab. 2.Transformer (Oil Type) Three phase a.Standard: IS : 1180 Part 1 Lavel 2 b.Vector group : Dyn 11 c.Rating : 400 KVA d.Cooling System : ONAN e.Winding : Copper , Class of Insulation: A f.% impedance: 6.25% (IS Tol) g.High voltage :11KV - 50 Hz h.System highest voltage : 12kV at the HV side i.H.V.Power Frequency (KV rms): 28 kV j.H.V. Impulse withstand voltage (KV peak ): 75 kVp k.Off load Tapping: +5% to -10% in steps of 2.5% l.Oil temperature rise /winding temperature rise as per IS 1180 Part 1 m.Losses at 50% loading at rated voltage & frequency: 5.05KW (Max) n.Losses at 100% loading: 15KW (max) o.Make of Tranformer shall be ABB, Siemens, Schneider, BHEL/ AAI Approved make 3.LV COMPARTMENT The LV compartment with Degree of protection -IP54 designed for a 50 degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment a.433V air insulated Alumimum busbar having capacity 800A, 50Hz, 50KA withstand fault level capacity. b.Incommer cum Outgoing - 4 Pole, 600A, Fixed Manual Microprocessor based, fixed type ACB with S/C, O/C & earthfault release. The fault system of 50KA, Ics=Icu=Icw for 1 sec. Make-Schneider/ABB/Siemens c. 150KVAR APFC panel 4.Outdoor Enclosure:- The Enmclosure shall be made of 2.0 mm thickness Galvanized Sheet Steel tropicalised to meet Indian weather conditions including all the partition sheets & doors. The base of the enclosure shall be made of 4.0 mm thickness Hot Dip Galvanized Sheet Steel to ensure rigidity for easy transport and installation. The entire package Substation shall be factory assembled & Factory fitted. The enclosure shall have IP54 degree of protection for HT< switchgear compartment IP34 degree of protection for transformer compartment. The enclosure to be tested for Internal Arc Fault Test to the tune of atleast 20KA for 1 second adhering to as per latest IEC 62271-202.The temperature rise test on enclosure for K10 class.The enclosure exterior shall be powder coated.The compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. RMU, Transformer and LT Panel of the same make preferred.
Supply, Installation and testing commissioning of DG set with AMF panel comprising of minimum 250 KVA prime continous (actual) rating, multi-cylinder diesel oil engine with rated capacity of suitable BHP at 1500 r.p.m, direct electronic fuel injection type vertical 4 stroke along with base frame coupled to alternator of suitable capacity capable of delivering true 250 KVA (144 KW at 0.8 PF), brushless type, 3 phase 4 wire 415 V AC supply, self exiting alternator with residential silence and self regulated through an AVR, acoustic enclouser and exaust piping as per pollution control board standards, Lube oil system, Electronics Governor, water cooled with radiator,fly wheel , electric starting equipments, batteries, battery charger, instrumentation , fuel tank with minimum 990 ltrs. Capacity fabricated with 14SWG sheet metal complete with drain valve, air vent, inlet and outlet connection, level indicator including necessary G.I. pipe line from day diesel tank to DG set, return line, controling valve etc with M.S frame structure support as required, Silencer with bellows, alarms, Engine control panel, AVM pads, AVR panel, AMF control panel,including cable termination box with all other associated equipment/ work as per specifications. The work should be as per Centeral Electrical Inspectorate/pollution control board standards. (Refer technical specification).
Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
Supply, installation, testing and commissioning of suitable size MS Black Pipe (B-Class) complete with Bends ,Flanges, clamp, fastner, nuts and welding at joint as required for Silencer Extention With Aluminium Clading as per CPCB and providing stack analysis port as per norms of pollution control board. (250 KVA).
Supply , Fixing, connecting and commissioning and testing of company Make Power factor improvement panel of capacity 200 KVAR fully type test according to IES 614319- 1&2, IEC transformer (indoor) type Panel factory made, weather proof, dust and Vermin Proof (IP42) suitable for Humidity: up to 95% average daily temprature : +35'C max, Ambient termperature : 5'C to 45'C , Miximum altitude :2000 m,110 V/660V grade 3 Phase 50 HZ AC supply floor mounted, fabricated out of 14 SWG MS sheet welded on 40 x 40 x3 mm angle iron frame /base of appropriate size and having four Nos angle iron legs made out of 40 x40x 6mm 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with sutable size thimbles , lugs duly painted with siemens grey epoxy powed coating after suitable chemical treatment, Legs duly embedded in ground in PCC1:3:6 of suitable size including locking arrangement suitanle for mounting, with required sheet metal enclosures, thimbles, all as specified and directed by Engr-in-charge and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper NYVIN cable of suitable size and PVC flexible conduit medium quality as required , comprising of the following:- (a) Insulated Bus Bar linergy which is of extruded Aluminium infused with copper at contact terminals of copper of 800 Amps capacity for three phase, fixed on insulators, Busbar should be PVC sleeved with Red, Yellow & Blue colour , Bus bar support should be of SMC/DMC , Rated impulse withstand Voltage 8 KV (b) Incommer MCCB 400 Amp , Electronic trip unit Micrologic 2.3 (LSI protection ) Three Pole ,Ics = 100% Icu as per IEC 60947-2 , Adjustable thermal setting 0.7 - 1 x in, Class II front face, 50KA rupturing capacity, Isolation with positive Break indication with Double Break Contacts, Standard Exended Rotary Handle , speraders, Phase Barrier. c) Capacitor 200 KVAR (2 x50 KVAR+1 x100 Kvar, 1:1:2) Metallised polypropylene film with Zn/Al alloy can type capacitor bank of reted 525 Volt, Miximum over current:1.8 In, Overpressure protection , Discharge resistance 50V -1 min , Capacitance Toletance -5% +10%, Miximum permissible over current (With thermal protection included) 1.43 In , Maximum permissible over Voltage 1.1 x Un , 8 h every 24 h, of rated 480 volt with detuned Reactor of detuning factor (P) 14% and suitable output of 200 KVSr at 440 volt overheating protection by thermostat confirming to IS-13340-1993/,13341-1992 & IES-60831-1+2. d) Varplus logic APFC relay- Advanced Range (Ref:-VPLO6N) VPLO6, 6 step, LCD Display, 90 V-550V 50/60HZ 1A/5A with RS485,(144 x 144mm). e) CT 400/5A , 10 V.A, CL : 1.0, Resin Cast , CT Secondary wire size should be 2.5 sq mm. f) Accessories for 50 KVAR Capacitor Bank. (i) Capacitor Duty Contactor (AC6b) 50 Kvar with damping resistors which limit inrush current , 440 volt ,3 ph,50 Hz, coil-220 Vac. (ii) MCCB, TB ,100Amp, 50 KA , TMD, g) Accessories for 100 KVAR Capacitor Bank :- (i) Capacitor Duty Contactor (AC6b) 50 Kvar with damping resistors which limit inrush current , 440 volt ,3 ph,50 Hz, coil-220 Vac. (ii) MCCB, TB ,100Amp, 50 KA , TMD h) Ventilation fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switchin ON and OFF of fans depending upon the temperature of the panel. 230 V AC, 2650 rpm, 160 cu.m/h, flying leads. (i) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to with stand high temperature, housed in cubical panel (CPRI approved ) made out of 2mm thick MS sheet factory made as per , the enclosure sustms for the varset are type tested as per IES 62208, The enclosure sustem are certified to IES 62202 duly powder coated front and rear door open able with loking arrangement complete with, IK 10 protection against mechanical shocks as per IEC62262 foundation as required or recommended by manufactured Make of APFC panel : schneider cat No :-VS200R27T or equvilant.
Supply of 3 Core, following sizes of XLPE insulated PVC sheathed aluminium conductor armoured Power cable of 11 KV grade (11 KV earthed system) conforming to IS: 7098 (part-II) amended up to date.
a) 3C x 300 Sq mm
Supply of 3.5 core 1.1 KV grade XLPE insulated, armoured armoured Alumimium Conductor Cable confirming to IS 7098 (Part-I) 1988 amended upto date of following sizes :
3.5C x 300 Sq mm
3.5C x 240 Sq mm
3.5C x 70 Sq mm
3.5C x 25 Sq mm
4C x 16 Sq mm
4C x 10 Sq mm
Supply of following size control copper conductor Cable confirming to IS 7098 (Part-I) 1985 amended upto date of following sizes :
10C x 2.5 Sq mm
4C x 2.5 Sq mm
Supply and making end termination with brass compression gland i/c proper socketing etc. as reqd for 1.1 KV grade XLPE Al . cond.cable of following sizes.
3.5C x 300 Sq mm
3.5C x 240 Sq mm
3.5C x 70 Sq mm
3.5C x 25 Sq mm
4C x 16 Sq mm
4C x 10 Sq mm
10C x 2.5 Sq mm
4C x 2.5 Sq mm
Supplying & making indoor cable end termination with heat shrinkable jointing kit complete with all acccessories, including lugs suitable for 3 core 300 sq.mm size of 3 core XLPE aluminium conductor cable of 11 KV grade complete as required.
Supplying & making outdoor cable end termination with heat shrinkable jointing kit complete with all acccessories, including lugs suitable for 3 core 300 sq.mm size of 3 core XLPE aluminium conductor cable of 11 KV grade complete as required.
Supplying and laying of following size DWC HDPE pipe PE 63 Grade ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. Mm
Above 35 sq. mm and upto 95 sq. Mm
Above 185 sq. mm and upto 400 sq. Mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.
Upto 35 sq. Mm
Above 35 sq. mm and upto 95 sq. Mm
Above 185 sq. mm and upto 400 sq. Mm
Supplying of Rubber hand gloves suitable for 11kV grade .
Supplying and fixing of Shock treatment chart both in Hindi & English and framed with 5mm thick glass as required.(Frame A2 Size).
Supplying and fixing single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. As required complete on wall.
Supplying and fixing of flame retardant electrical insulation mat having no adverse effect of mineral oil, high insulation resistance and water proof of nominal size: 2.5mm +/- 10% thick and 1000mm +/-20mm wide Antistatic Electric Insulated Synthetic Mat confirming to IS: 15652: 2006 with upto date amendments suitable for 11 KV installation alongwith adhesive/resin, sealing material and similar type of taping on sealing at all joints and corners as per recommendations etc as required .The Mat shall be ISI marked. Its leakage current at 11 KV shall not be more then 10 mA.The mat shall be welded by hot gas lending with filler martial method by making V grove cut at joints with suitable welding cord of insulation material of matching colour to provide a seamless jointed surface as per IS:8002
Supply of Electrical safety kit, Voltage 11 KV Consisting of safety shoes,discharge rods, rescue sticks, safety signage,first aid box, safety torch, fire blanket, gloves, electrical rubbermat etc.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Supply, installation, testing and commissioning of 80 Ltrs. Self contained Stainless steel, storage type, water coolers with inbuilt Stage purification Reverse osmosis Water Filter Cum purifier suitable for operation on 230 ± confirming to the requirements of ISS 1475/78 havimg refrigeration system capacity of 60 ltrs at 17 degree centigrate ± 1 degree complete with compressor, thermostat and stainless steel tank i/c placing the water cooler at concern location and as per site requirement.
SITC of 5 KVA automatic voltage stabilizer suitable for 60/120 Ltr. Capacity storage water cooler in/c provision of time delay relay setting of 3 to 5 min., automatic cut off low & high voltage connection of suitable size complete etc. as required.
Supply, installation, testing and commissioning of following Automatic Stainless Steel Air Curtains with in built sensors suitable for entry/exit doors in City side and Air Side of Terminal Building as per site requirement and direction of Engg.In-charge.
900mm length
1800mm length
Supply, installation, testing and commissioning of Automatic Stainless Steel Hand dryers in toilets in Terminal Building as per site requirement and direction of Engg.In-charge. (Make-toshi Model-HK-2400 CA or equivalent)
SITC of Integral LED Solar Street Light Pressure Die Cast Aluinium Housing (LM6 Alloy), reliable & robust construction, Minimum 4500 system lumens with system wattage 12V DC, efficacy of 170 lumens/watt, SMD LEDs with PMMA Lens plate, External built proper heat sinks and UV stablized Toughen Glass/PC ensuring IP65 & life of LED luminaire engine should be 50000 hrs along with built in high efficiency MPPT charge controller & driver along with LiFePO4 (Lithium ferro Phosphate) battery chemistry & high efficiency reliable PV Module suitable for even harsh conditions, CCT>5700, CRI 70. Solar panel module capacity 12V Battery capacity 380Wh, 60Watts peak & Solar cell efficiency min 12% polycrystalline. The fixture should have designed for street light application & should have flexible angle of mounting from 0-15 Degree for divers, geographical condition. Factory configured LED's load & dimming for optimum of autonomy uses up to 18 hrs. The luminaire should work on Hybrid mode with priority for solar, in case solar charging is not available the it should automatically switch to AC grid supply for reliable operation. Solar panel performance should confirms to EN53030. System should have smart self-diagnostic feature for indicating batter charging, cut off & fault if any. Company Logo shall be engraved to avoid any distrusts, complete system should have minimum warrantee of 36 months etc. as required. (Similar to Philips BRP. LED45 CW MR S1 12V LFP AIO Solar Equip IN, OSRAM LT or Equivalent)
Supply of LED street light fitting having system lumen output not less than 4500 lumens and system efficacy of not less than 110 lumens per watt and lumen maintainence of 70% at the end of 50000 burning hours, Power Factor≥0.95 & THD<10%, CRI>70, CCT : 4000K ± 300K, made of high pressure die cast Aluminium/ standard alloy housing with separate optics and control gear compartment, toughened glass protector, permanently sealed and a removable control gear plate, mounting spigot suitable for horizontal mounting (Ø 32 – 42mm) with tilt flexibility upto (+)(-) 15 degrees, operating range 150 – 270V AC supply voltages, surge protection≥10KV with minimum IP:65 Protection. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. (Similar to Philips CAT No. BRP062 84 CW SLC S1 PSU or equivalent).
Supply of LED decorative post top luminaire consisting of a high-pressure powder-coated die-cast aluminium housing suitable for vertical mounting on 75 mm outer dia pole having system lumen output not less than 2450 lumens and system efficacy of not less than 110 lumens per watt and lumen maintainence of 70% at the end of 50000 burning hours, Power Factor≥0.95 & THD<10%, CRI>70, CCT : 4000K ± 300K, operating range 150 – 270V AC supply voltages, surge protection≥10KV with minimum IP:65 Protection. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection. (Similar to Crompton Maple LPTO-40-CDL or equivalent).
SITC of 17-25 Watt LED Bollard having lumen not less than 900 lumens with luminaire efficacy of not less than 110 lumens per watt, lumen maintainence of 70% at the end of 50000 burning hours with constant current driver output, Power Factor ≥0.95 & THD <10%, CRI>70,neutral white light and made of GI pipe bottom housing the control gear speen Aluminium dome shaped type cover with cylindrical dome shaped top cover, overall lenght of bollard to be minium of 600 mm, operating range 150V – 270V, 50Hz AC supply, inbuilt driver with surge protection ≥10KV. The luminaire shall be minimum IP:65 protected. LM 79 report to be submitted for luminaire from NABL accrediated lab and LM 80 for LED source issued by LED manufacture. LED shall have reverse polarity, open and short circuit protection.(Similar to Philips BCP400 LED09 CW PSU GR S1 or equivalent).
Supply of 6 mtrs. high GI OCTAGONAL continuously tapered galvanised street light pole with minimum 1000 mm long single arm GI bracket (length of bracket shall be based on design) for installation of LED street light luminaire suitable for wind velocity as per IS 875 (but not less than 50 m/sec.), fabricated out of 3 mm MS plate in single section, suitable for installation on a precast foundation with supply of 4 nos. of foundation bolt & anchor plate, rigid flange plate (200x200x12mm min.) welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistant door flush with the exterior surface containing a terminal plate of 5 mm thick backlite sheet with 32 Amp heavy duty connector for loop in loop out cable terminations suitable for upto two numbers 4 core 25 Sq.mm cables & 2A DP MCB for each fixture connections, earthing bolts for continuous earth connection complete as required & as specified.
Erection of 6 Mtr.high OCTAGONAL street light pole & bracket with all accessories in reinforced cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling including positioning of template & foundation bolts (supplied with pole to match with pole base plate) & providing and fixing of DWC HDPE pipe of size 50 mm dia (2 pieces of min. 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole complete as required and as specified.
Installation, testing and commissioning of LED street light fitting with all accessories on existing street light pole of 6 mtr height with bracket, including supplying and drawing of 3core 1.5 sq.mm. PVC insulated PVC sheathed flexible copper conductor cable from loop-in-loop-out box upto the individual streetlight fitting(s), connection etc. complete as required & as specified.
Supply, installation, testing and commissioning of 20 KVA,3- Phase input and 3- Phase output UPS alongwith lead acid batteries giving a back up of minimum 30 min. at full load as per specification alongwith all accessories including interconnecting cables, lugs, Base Frames, Battery Rack & Battery Circuit breaker complete as required. 20 KVA / 20KW (Modular Construction) , UL Certified Online UPS (3Ø-3Ø) operating in stand alone Mode. WARRANTY : 1 Year On UPS. SPECIAL FEATURES of UPS : Unity power factor Paralleling up to 4 units Dual mains option Voltage Range : 307 - 477 VAC INPUT FREQUENCY : 45-65 HZ OUTPUT VOLTAGE : 400 VAC DSP Controlled Double Conversion online technology using IGBT Efficiency: > 97% DC BUS : 384VDC Input power factor correction to unity Emergency Power Off Inbuilt automatic & manual by pass
Battery bank consisting of 12V-26AH EXIDE / U-PLUS / LEOCH / QUANTA or Equivalent Make sealed maintenance Free (SMF) batteries for 30Mins. Battery back up mounted in open iron rack. Warranty : 02 Years Included accessories & Components:- Open iron rack for battery bank Battery connectors DC Breaker
LT Panel for UPS shall comprises of :- Input & Output switchgear (4-pole, 65KA, 100A MCCB)-1set Output Copper cable from UPS to Load distribution panel (4X10sqmm)-15MTR. Input Copper cable from LT panel to UPS- (4X10sqmm)-15MTR.
Design and supply of powder coated single sided LED illuminated sign board made out of 2mm thick aluminium profile with suitable angle support, 1.5 mm thick aluminium backcover, 5 mm thick cast Acrylic sheet on front with letter & symbol on self adhesive vinyl sheet ( 3M/Avery/LG) applied on the acrylic sheet, uniformly internally illuminated with required LEDs to achieve illumination level, convertor/driver, operate without flickering on single phase 230 V, 50 Hz AC supply,with mounting arrangement as required.
SIZE 400 mm (L)x 300mm(W) x 75 mm(D)
SIZE 600 mm (L)x 400mm(W) x 75 mm(D)
SIZE 1200 mm (L)x 400mm(W) x 75 mm(D)
Design and supply of powder coated Double sided LED illuminated sign board made out of 2mm thick aluminium profile with suitable angle support, 5mm thick cast Acrylic sheet on front & back with letter & symbol on self adhesive vinyl sheet (3M/Avery/LG) applied on the acrylic sheet, uniformly internally illuminated with required LEDs to achieve illumination level, convertor/driver, operate without flickering on single phase 230 V, 50 Hz AC supply,with mounting arrangement as required.
(a) SIZE 1200 mm (L)x 400mm(W) x 150 mm(D)
Design, supply, installation, test and commissioning of heavy duty bed conveyor for departure/arrival area as per lengths given below measured across the centre line having frame 1050 mm (useful width not less than 1000 mm) and 400 mm height from finished floor level for easy handling passenger baggage weighing 60 Kg. per linar mtr of size 120 X 90 X 45 cm at a speed of 21 mtr/mints complete with PVC belt on bed construction as specified i/c drive unit & end pulleys, take up pulley/ side panels with 1.6 mm thick. stainless steel all other accessories for successful commissioning of the conveyor as per following length & specification / drawings.
For Arrival Area:- 09 mtr. Long Take - Collector / away conveyor
For Departure Area:- 12 mtr. Long Take - Collector / away conveyor
Supply and & installation of draught curtain cover the opening of conveyor belt both in Arrival and departure fabricated with 3 mm thick Nylon Rubber flaps, to be fixed by SS flat strip as per the size of shutter opening etc. Complete as required for the opening size as per dimentions/ drawings approved by Engg-in-charge etc. as required : 1.5 mtr.(L) X 1.35 mtr.(W)
SITC of electrically operated rolling shutter to suit to the opening in wall fabricated extruded Aluminium provided with suitable rated tubular geared single phase motor directly coupled to the shaft of the shutter, limit switch or sensor interlock with conveyor starter, complete with guide channels, wiring, earthing, painting, etc. as require for the successful operation of the shutter for the opening size : 1.5 mtrs. (L) X 1.35 mtr. (W)
Design, supply , installation, testing and commissioning of gravity roller structure of 1.5 mtr. In length measured along the Centre line complete in all respects i/c frame section, MS rollers, ball bearings supports and MS side guards.
Design, supply , installation, testing and commissioning of gravity roller structure of 1.5 mtr. In length measured along the Centre line complete in all respects i/c frame section, SS rollers, ball bearings supports and SS side guards.
Wiring:- Wiring for motor with 3 X 1.5 sq.mm. stranded copper conductor1.1 KV grade PVC included cable in recess/surface steel conduit/Cable Tray as required including termination at motor and panel board complete with making connections with the existing earthing system.
For Arrival Area:
For Departure Area:
SITC of weighable feed conveyor completed digital display weighing scale of minimum 300 Kg. Capacity with suitable PVC belt, pulley fitted with bearings in pillow block, return rollers, slider bed with useable width of 650 mm side guard of SS Sheet of 1.6 mm thick and overall width of 820 mm X 1200 mm long with suitable capacity driver motor, coupled with gear motor assembly including all electrical interconnections, operatable with foot switch etc. as required and as per specification/ drawings approval by Engg In - Charge etc. as required.
SITC of feeder conveyor (Dispatch Conveyor) complete with suitable PVC belt, pulleys fitted with bearings in pillow blocks, return rollers, slider bed with useable width useable width of 650 mm side guard of SS sheet made of 1.6 mm thick and overall width of 820 X 1200 mm with suitable capacity drive motor, gear box assembly including all electrical interconnections, etc. as required and as per specification / drawing approval by Engg-In-Charge etc. as required.
Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS as required.
2- LOOPS
Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications. (Cost of plug in common base shall deemed to be included in cost of detectors)
Supply, installation, testing and commissioning of UL / EN listed (Latest Version) Response Indicators for getting fire indications of detectors installed above false ceiling area interconnecting to loop cable complete as required.
Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable Manual call station (pull type) suitable for semi flush mounting, IP 54 for indoor use & IP 65 for outdoor use with inbuilt fault isolator / isolator module with double gang outlet box, equipment for key operated test-reset lock, electronic or rotary switches for address setting. Manual pull station shall be connected with two wire to SLC loop of Fire Control Panel. Cover shall be made out of LEXAN (or poly carbonate equivalent) with clear operating instruction and the word Fire appearing on the front complete with connections etc. as required and as per enclosed specifications
Supply, installation, testing and commissioning of UL / EN listed (Latest Version) Addressable Intelligent sounder with range of 25-30 meters with 5 Watt Output including connection etc. as required (as per specification).
Supplying & laying of 2 x 1.5 sqmm fire survival armoured cable, 600 / 1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. .
NOC Charges of fire alarm detection & Fire fighting system..
Supply, erection and testing of ISI marked M.S. Pipes (Class C and special etc. as per IS:1239 for above/under ground laying for hydrant system including transportation of materials up to the worksite, cutting the pipes to required length, edge prepation, welding, fixing/laying of pipes including special i.e. bends tees, reducers flanges etc in proper position including all supports as per layout, by welding aligning the pipes line, wrapping & Coating with Pyp coat etc. providing taping of pressure gauge and for other instruments etc. Hydrostatic testing of systems as specified, flushing & cleaning by water etc complete as per drawing & direction of the engineer-in-charge.
150 mm dia
100 mm dia
Supply & installation of ISI marked single headed 63 mm dia S.S. Hydrant Valve, flanged inlet with 63 mm female instantaneous outlet confirming to IS 5290 on the fire wel riser/down comer including marking 80 NB pipe connection with riser fixing the landing valves in proper positions, including supply of nuts, bolts gaskets, caps chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer-in-charge. (Make: Fires/Safex/Mi8nimax/Newage/Kartar/GETECH)
Supply & fixing in position ISI marked cast iron double flanged Butterfly Valve as per IS : 13095, suitable for pressure 15 KG/cm² including transporting to worksite, supply & fixing nuts, bolts, gaskets, flanges & washers etc including testing, complete as per drawings & direction of the Engineer-in-charge (Make: Kirloskar/Venus/IVC/Zoloto/Kalpana/Kartar.
100 mm dia
150 mm dia
Supply, installation, testing and commissioning of ISI marked cast iron Dual type Non Return Valve with provision of cutting, flanges, welding, nuts, bolts labour and material complete all as directed for the following sizes Make: Getech/Minimax/Newage/Kartar.
100 mm dia
150 mm dia
Supply, fixing testing & commissioning of 20 mm bore and 30 meter long hose (Rubber lined Dunlopi pipe) and hose reel for first aid fire fighting confirming to IS:884, with full swing drum, fixing brackets, 5 mm dia shut off Plastic nozzle 32 mm dia, hand level operated ball valve, connecting directly from the riser through 32 mm dia G.I. pipe with sockets, elbows, nipples etc including providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respect as per drawings and directions of Engineer-in-charge. (Make: Dunlop/Goodyear/Getech).
Providing S.S. ISI marked 63 mm dia instantaneous paitem short branch pipes & 16 mm dia Nozzle suitable for interconnections to hose pipe coupling as required. (Make: Minimax/Firex/Safex/Newage/Getech)
Providing ISI marked RRL (IS:636 type-II) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS:903) stainless steel male and female coupling complete as required. (Make: Joyshree/Newage/Getech/BRG).
Supply & installation of 4 way 63 mm instanteous inlet for fire brigade connection and making connection with 100 NB fire fighting wet riser pipe or under ground water tank and fitting inlets with caps and chains in a 4 mm thick glass fronted box of 16 SWG MS sheet, fixing it on the ground level on concrete base or on MS Angle Iron frame painting with two coats fire red paints over primer coat, complete the work in all respect as per the directions of the Engineer-in-charge. (Make Firex /Safex /Minimax /Newage /Getech).
Supply, Installation, Testing and commissioning of Fire brigade drawout. Make Getech/Minimax/Newage/Kartar.
Supply and fixing of Pressure Switch.
Supply and fixing of Pressure Guage.
Providing and fixing weather proof standard fire hose cabinet (900 mm X 900 mm X 600 mm) suitable for accomodating single headed hydrant valve made of not less than 16 SWG MS sheet having central opening glassed door (4 mm thick cleaned glass) including necessary locking arrangement with handle of housing two nos. 15 meter long fire hose pipes, branch pipe and hydrant valve as required including painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on suitable raised brick masonry (i.e.) paltform or on MS Angle iron frame as desired. The words "FIRE HOSE" to be painted on the box.
S/I/T/C of Electric driven Main Fire Pump of Kirlosker Make with desired head and 2280 lpm @ 2900 rpm with bronze Impeller and stainless steel shaft of suitable H.P., complete as required so as to develop a minimum pressure of 3.5 Kg at the fartest and Highest Point.
S/I/T/C of Diesel Engine Driven Standby Fire Pump of Kirlosker Make with desired head and 2280 lpm @ 1500 rpm with bronze Impeller and stainless steel shaft of suitable H.P., complete as required so as to develop a minimum pressure of 3.5 Kg at the fartest and Highest Point.
S/I/T/C of Driven Jockey Pump of Kirlosker Make with desired head and 180 lpm @ 2900 rpm with bronze Impeller and stainless steel shaft of suitable H.P., etc. complete as required.
Design, manufacture, supply storing, inspection, handling, assembling, installation in correct alignment, position, affecting proper connections, testing and commissioning of 18 SWG CRCA sheet steel fabricated cubical type Electrical Control Panel for fire fighting pumps floor mounting, dust & vermin proof front operated construction, enclosure class-IP 52, Painting by one coat of red oxide primer with two coats of approved synthetic enamel paint complete with top/bottom removable gland plates, as required, double compression type cable glands earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connection shall wiring by min 2.5 sq.mm. copper wires, ckt labels. The Copper Bus Bas shall be of suitable length 500 volts, 3 phase 50 Hz TPN. Electronic copper.
Hydro Pneuymatic System Supply, Installation, Testing and Commissioning of Hydro Pnematic pump System (01 main + 01 Standby ) with Flow (LPH ) 15000 (Each Pump) , Head (Mtrs.) 22.0 , Motor Size 2.2 KW Each which includes 02 Nos. Pumps with Motor (IES), GI Suctin and Discharge manifolds along with necessary valves m NRVs Pr. gauge , Base frame and Microprocessor Based Panel connected with Variable frequency drive (VFD) as per site requirment and approve make list.
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body,squeeze lever discharge valve fitted with internal dischargetube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with initial charging (In each FHC). Capacity 4.5kg. I.S.I. Marked. (IS : 2878)
Providing and fixing ABC type (stored pressure) extinguisher as per IS : 13849 - 1993 consisting of welded MS cylindrical body ,with discharge hose, discharge valve, suspension bracket, initial filling etc complete as required.
(I) Capacity 6 Kg.
(II) Capacity 9 Kg.
Supplying and fixing of Mechanical foam stored pressure type fire extinguisher 9 kgs. capacity of approved make with wheeled trolley as required conforming to IS: 15683.
S. N ELECTRICALS
M/s Anil Enterprises
Deora Electricals
DOSHI ELECTRIC ENGG. CO.
PRAGYA ELECTRIC AND ELECTRONICS CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .