Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | Admitted-Finance |
Tender Value
₹23.4 L
EMD Value
₹46,800
Closing Date
15 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI T C SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR-342010 (RAJ)
Repair/Maintenance to various petty items connected to E/M nature of works in the different buildings of OTM and Md Accn at Ralawas under AGE (I) Nagtalao
2021_MES_413695_1
CWE (A) JODH/NAG-129 OF 2020-21
Open Tender
Civil Works
Item Rate
330 days
ARMY AREA JODHPUR
4 documents required · 4 mandatory
₹500
AGE(I) Nagtalao
₹46,800
Yes
1 Mar 2021
18 Jan 2021
16 Feb 2021
18 Jan 2021
15 Feb 2021
8 Feb 2021
60 days
Amount
Skilled Electrician - 01 Nos in each shift for three shift is required for attending complaints i.e. repair of internal electrical items like Fan, Exhaust Fan, Air Circulator, Geyser, Light Points, Tube Lights, Mirror Light, Bulb Holder, 2x2 square fittings, Switch, Sockets, Door Bells, Repair to DBs, MCBs, Ceiling Rose, Fan Regulator, MCCBs, Minor repair to Panel Board and related cables, Earthing, Point Wiring, Desert Cooler, Flame Proof Fittings, High Bay Fittings, Metal Clad Sockets, Special Power Supply, No Light Complaint, Sub Main Wiring, Loose Wire Complaint, Casing Caping/ Conduit Pipe Complaint and other specific complaints as directed and specified by Engg In Charge of the following location under AGE (I) Nagtalao AOR (a) Md accns MAP (b) Md accns Ralawas (c) OTM line area (d) Tech area Note:- (a) Contractor will arrange facility for registering of Complaints / opening of ARMAAN complaints on day to day basis and issue the complaint slip in triplicate to workers and also forwarding necessary report/feedback to concerned JE, AGE, AGE(I) etc as directed and specified by JE / Engg-in-charge. (b) Cost of T&P, Transport, Stationery and Equipment etc required for running of complaint management system is deemed to be included in the respective items. (c) Materials taken in this schedule as supply only will be fixed by contractor's labour at site without any extra cost.
Unskilled Helper - 01 Nos in each shift for three shift is required for attending and assisting to the Electricians, , etc of the following location under AGE (I) Nagtalao AOR (a) Md accns MAP (b) Md accns Ralawas (c) OTM line area Ralawas (d) Tech area Ralawas
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, lamp holder and conduit etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC. Note:- The damaged surfaces to be made good with plastering & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by one switch, complete all as specified for the following:- (a) One light / fan point controlled by one, one-way switch, SP, 6 Amps.
All as per Srl Item No 4 above but One socket outlet, 3 pin, 5 Amp, 230 volt flush type on same board.
All as per Srl Item No 4 above but One switch socket outlet, 3 pin, 5 Amp, 230 volt flush type on independent board.
All as per Srl Item No 4 above but with 2.5 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 1.5 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed.
Supply only switch piano, flush type, single pole, one way, 5 Amps 230 Volts ISI Marked. complete all as specified and directed by EIC.
Supply only switch piano, flush type, single pole, one way 15 Amps 230 Volts ISI Marked complete all as specified and directed by EIC.
Supply only socket outlet 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply only socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, ISI Marked complete all as specified and directed by EIC.
Supply only switch socket combination 2-in-1, 3 pin, 5 Amps, flush type with shutter, ISI Marked complete all as specified and directed by EIC.
Supply only switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type with shutters, ISI Marked complete all as specified and directed by EIC.
Supply only electronic regulator, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd.
Supply only ceiling rose, surface bakelite, three terminals all as specified and as directed by EIC.
Supply only Batten/Angle Holder ISI Marked for fixing bulbs complete all as directed by EIC.
Supply only Pin Top 5 / 15 Amp ISI Marked complete all as directed by EIC.
Supply only buzzer, ding dong AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply only Bell push, AC 230 Volt, Single pole (ISI Marked) all as specified and as directed by EIC.
Supply only SPN DB's, 240 V, double door 200 amps rated bus bar, complete all as specified and as directed., (a) 12 way
All as per Srl Item No 20 above but 8 way
All as per Srl Item No 20 above but 4 way
Supply only 4 way TPN DB, 415 V, double door 200 amps rated bus bar, complete all as specified and as directed by EIC.
Supply only 4 way VTPN DB, 415 V, double door 200 amps rated bus bar, including 100 Amps 4 pole, 16 KA MCCB, complete all as specified and as directed by EIC.
Supply only Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp.
Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, copper conductor cable 1100 volts grade drawn through and incl 20 mm size of of non mettalic PVC FRLS conduit accessories and fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. (a) 02 runs 6 sqmm conductor cable and 01 run of 6 sqmm as earth continuity conductor.
All as per Srl Item No 26 above but 02 runs 4 sqmm conductor cable and 01 run of 4 sqmm as earth continuity conductor.
All as per Srl Item No 26 above but 02 runs 2.5 sqmm conductor cable and 01 run of 2.5 sqmm as earth continuity conductor.
Supply only condenser 240 volts 2.5 MFD, Heavy duty incl testing.
Supply only condenser 240 volts 4 MFD, Heavy duty incl testing.
Supply only PVC boards for mounting, switches, sockets, fan regulator, etc. (a) 3 module. Note:- (i) Switches, sockets, fan regulator, etc.used in PVC boards will be measured and paid seperately under relevent items.
All as per Srl Item No 31 above but 6 module
All as per Srl Item No 31 above but 8 module
All as per Srl Item No 31 above but 12 module
Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following :- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. Note : Irrespective of the complaints, work against entire qty under this item of BOQ shall be completed with in set period of 45 days after handing over the site as per work order No 1 failing which recovery @ Rs 200/-/per geyser per day delay shall be effected from the contractors payment.
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repair of heavy duty pin type fastener 4 long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed.
Supply only heating elements ISI Marked of following different capacity complete all as directed by Engineer-in-Charge :- (a) Capacity 1.50 KW
All as per Srl Item No 37 above but Capacity 2.00 KW
Supply only thermostat suitable for 1.5/2.00 KW geyser all as directed by Engineer-in-Charge.
Supply only PVC connection 15mm bore,heavy duty suitable for 1.50/2.00 KW geyser all as directed by Engineer-in-Charge.
Supply and fix in and replacement of glass wool for geysers complete all as specified and as directed.
S&F in replacement base assembly, compatible to existing gyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F in replacement indicator lamp for geyser of any type colour green & red complete all as specified and as directed.
S&F in replacement stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample complete all as specified and as directed.
S&F in replacement of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample complete all as specified and as directed.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enameled paints complete all as specified and as directed.
S&F in replacement outer body of MS sheet not less than 20 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repair 3 core PVC insulated copper cable of size 2.5 Sqmm multi stranded complete all as specified and as directed.
M&L for painting of outer surface of 25/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
vijay enterprises
Shree Karni Construction
vinayandsons
Bhawna Emporium
M/s Pankaj Enterprises
M/S JAGDAMBA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .