Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.8 CrAccepted-AOC | ₹50.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹52.5 CrRejected-AOC B 1 NEELA APARTMENT MANDPESHWAR INDL PREMISES S V P ROAD BORIVALI WEST MUMBAI 400 092 | ₹52.5 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹56.0 CrRejected-AOC | ₹56.0 Cr | L3 | Rejected-AOC L3 |
| 4 | L4₹71.6 CrRejected-AOC DADRA AND NAGAR HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | ₹71.6 Cr | L4 | Rejected-AOC L4 |
| 5 | Not Admitted-Fee/PreQual/Technical 403 GITANJALI ARCADE NEHRU ROAD VILE PARLE EAST MUMBAI MAHARASHTRA 400057 | MUMBAI | MUMBAI | MAHARASHTRA | 400057 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹44.8 Cr
EMD Value
₹54.8 L
Closing Date
17 Apr 2023, 3:00 pmClosed
CEO, SSCL
O/o the Chief Executive Officer, Silvassa Smart City Ltd, first Floor, SMC building, Silvassa.
Development of Truck terminus/Transport Nagar and provision of laybyes at Silvassa consisting of RCC, Architectural Finishes, MEP Services, Landscape and miscellaneous works including one (1) year Defect Liability Period.
2023_UTDNH_6368_1
SSCL/DNH/E-TENDER/TRANSPORT NAGAR/2022/72/133
Open Tender
Civil Works
730 days
Silvassa
As stipulated in the tender document.
4 documents required · 4 mandatory
₹15,000
Chief Executive Officer, SSCL
₹54.8 L
SSCL, Silvassa
21 Jul 2023
21 Mar 2023
20 Apr 2023
21 Mar 2023
17 Apr 2023
21 Mar 2023
21 Mar 2023 - 31 Mar 2023
31 Mar 2023
Amount
CIVIL WORK : Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials, disposing off the excavated stuff within the site at all lift/depth and Dewatering in all sorts of soil and strata, including removal of surface water, water from foundation, trenches, & ground water etc as necessary and as directed by Engineer-in-charge (B) Dense or Hard soil
Excavation for foundation upto 1.5 m to 3.0 m depth including sorting out and stacking of useful materials, disposing off the excavated stuff within the site at all lift/depth and Dewatering in all sorts of soil and strata, including removal of surface water, water from foundation, trenches, & ground water etc as necessary and as directed by Engineer-in-charge (C) Hard Murram
Excavation for foundation upto 3.0 m to 5.0 m depth including sorting out and stacking of useful materials, disposing off the excavated stuff within the site at all lift/depth and Dewatering in all sorts of soil and strata, including removal of surface water, water from foundation, trenches, & ground water etc as necessary and as directed by Engineer-in-charge (C) Hard Murram
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each deposited layer by ramming and watering.
Filling in plinth with sand under floors (brought from outside including any lead and lift, loading and unloading, spreading) including watering, ramming, consolidating etc. complete
Providing Material & Labour For filling in Foundation (Footing Base) & Plinth With Rubbles including filling Un screened gravel in Gaps & Consolidating Deposited ramming and consolidating etc. as directed.
Providing Material & Labour For Dry stone pitching 22.5 cm thick (including supply of stones ) 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. finished with Rulled Pointing in CM 1:3 all complete
Carrying out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatment including labour and material consistent with I.S.I specification. Using Chlordane and Chiorpurfiles 20 EC. As Per 6131_paret-II Concentration Weight one percent is recommended i.e. one litre 20 EC chemical emulsion with 19 litre give 1 % concentration inclusive of one litre chemical emulsion application at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S. Code
PCC & RCC: Providing material and labour for laying cement concrete 1:4:8 (1- Cement : 4 coarse sand : 8- hand broken stone aggregates 40 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Foundations, Footings, Base of columns and Mass concrete.
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts (Up to Plinth)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all the lead and lift including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts (Above Plinth Up to Two level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work , using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying, including the cost of centering shuttering finishing and the cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) excluding the cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts (Above Floor two level upto floor three level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts (Above Floor three level upto floor four level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Beams, Girders, Cantilevers, Lintels (Up to Plinth)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Beams, Girders, Cantilevers, Lintels (Above Plinth Up to Two level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Beams, Girders, Cantilevers, Lintels (Above Floor two level upto floor three level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Beams, Girders, Cantilevers, Lintels (Above Floor three level upto floor four level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Slabs, landing, cantilevers (Up to Plinth)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Beams, Girders, Cantilevers, Lintels (Above Plinth Up to Two level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Slabs, landing, cantilevers (Above Floor two level upto floor three level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Slabs, landing, cantilevers (Above Floor three level upto floor four level)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in RCC Walls (All floors)
Providing material and labour for laying in position Ready Mixed M-250 grade concrete for reinforced cement concrete work, using cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of work in transit mixer having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying with all lead and lift, including the cost of centering, steel/ply shuttering, strutting, steel scaffolding and propping, finishing etc and the cost of color pigments, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and durability as per direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS 456 shall be maintained) (Cement Level 450kg) excluding the cost of reinforcement for reinforced concrete work in Staircase (All Floor)
Providing Material and Labour for laying and fixing 50 mm thick expansion joint by hydro cel l semi rigid UV resistance with high performance laminated closed cell polythene foam joint filler in sheet foam as directed, etc. complete.
Providing Material and Labour for laying and fixing 25 mm thick expansion joint by hydro cell semi rigid UV resistance with high performance laminated closed cell polythene foam joint filler in sheet foam as directed, etc. complete.
Extra for additional height of propping and centering where the height of propping and centering exceeds 4.0 M between supporting floor to ceiling including temporary brick or stone pillars for supporting as required.
STEEL REINFORCEMENT Providing material and labour for Thermo Mechanically Treated bar (T.M.T.) (I.S.I. Mark) conforming to I.S. - 1786 Fe-500 D Steel for R.C.C. work including bending, binding and placing in position complete.(All Floor) Make: TATA, SAIL, TISCO, RINL, JINDAL, JSW Steel or Equivalent
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional (below/up to Plinth) including curing etc. complete
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional (Above Plinth Up to Two level) including curing etc. complete
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional (Above Floor two level upto floor three level) including curing etc. complete
Providing material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:6 (1- Cement : 6 -fine sand) (B) Conventional ( above floor three level upto floor four level) including curing etc. complete
Providing Material and labour for Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional (below/up to Plinth) including curing etc. complete
Providing Material and labour Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional (Above Plinth Up to Two level) including curing etc. complete
Providing Material and labour Half brick masonry in common brunt clay building bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:3 ( 1-Cement : 3-coarse sand ) with 2 Nos of 6mm Mild steel round bars after every three course embedded in Cement Mortar (B) Conventional (Above Floor two level upto floor three level) including curing etc. complete
Providing Material & Labour and fixing rolling shutters of approved make made of 80 mm wide M.S. laths inter-locked together through their entire length and jointed together at the ends by end locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation including the cost of hood cover and spring etc. complete.(A) Shutters having width below 3.5 M.
Providing Material & Labour For Fixing Glass Doors (Size 1800mm x 2400mm or As Required) using Teak Wood Frame of size 75 x 250 mm (1st Class CP teak wood) having 12mm thick Toughened Glass with Film (3M or equivalent Non reflective)of pattern and brand as approved by the Architect including fixing of all required accessories of approved brand as per detailed drawing / as directed by Engineer In-charge etc.complete. Including Floor Spring, S.S. Pipe Handle for door 30 Cm x 25mm dia ASIS 316 Grade , Door stoper, Godrej Mortice lock with cover , all Necessary hardware etc& including polishing work on teak wood Part as required Complete (Glass Make- saint gobian, Modi) (Hardware Make-Ozone,Kitch,Inox)
Providing Material & Labour with fixing of 35 mm thick Double Shutter Paneled Doors (1500mm x 2400mm Or as required)using Polished Teak Wood Frame of size 75 x 250 mm (1st Class CP teak wood) having Plywood Shutters with both size 4mm thk Decorative Veneer fixed with waterproof adhesives having pattern and brand as approved by the Architect,including S.S. Pipe Handle for door 30 Cm x 25mm dia ASIS 316 Grade , S.S. Stopper 30 Cm long of ASIS 304, Godrej Mortice lock with cover , all Necessary hardware aldrap etc(Veneer Make-century, green lam/) (Hardware Make-Ozone,Kitch,Ionx)
Providing Material & labour With fixing of 35 mm thick Single Shutter Flush Doors (900mm x2400mm or as required size) using Teak Wood Frame of size 75 x 150 mm (1st Class CP teak wood) having BWP Shutters with both size 1mm thk.Decorative Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, Including with S.S. Handle for Door 15 Cm size of ASIS 304 Grade , SS Aldrops 30 Cm long of ASIS 304 Grade , Stopper 30cm long SS 304 grade,Godrej Mortice lock with cover,fixing of all other accessories of approved brand as per detailed drawing Complete. (Laminate Make-century, green lam/Marino) (Hardware Make-Ozone,Kitch,Inox)
Providing Material & labour with Fixing of 35 mm thick Single Shutter Flush Doors (750mm x 2100mm ) using Polished Granite Stone Frame with round moulded edges having BWP Shutters with both side 1mm thk Laminate fixed with waterproof adhesives having pattern and brand as approved by the Architect, Including with S.S. Handle for Door 15 Cm size of ASIS 304 Grade , SS Aldrops 30 Cm long of ASIS 304 Grade , Stopper 30cm long SS 304 grade,Godrej Mortice lock with cover,fixing of all other accessories of approved brand as per detailed drawing Complete. (Laminate Make-century, green lam/Marino) (Hardware Make-Ozone,Kitch,Inox)
Providing Material and Labour With Fixing of coloured Powder Coated/Anodized Alluminium sectional Sliding door using JINDAL Delux series sections or equivalent having MIn. Wt 1.02 Kg /Rmt. and with shutter made of Alluminium Composite Pannel 5 mm thick including anodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge. Coplete with all required accessories & Hardware Like aluminium Powder coated Handle,Stopper, lock etc .(Alu. section Make Jindal, / ACP : Alu Decor,Aluco Bond,Eva bond, )
Providing Material and Labour With Fixing of coloured Powder Coated/Anodized Alluminium section Three Track windows using JINDAL Delux series sections or equivalent having Min. Wt 2.50 Kg /Rmt.for Frame and Min. Wt 1.02 Kg /Rmt. for Shutter and having Shutter of 5 mm thick transperant glass and Mosquito Nets including anodized aluminum fixture and fastenings etc. complete as per detailed drawings and directions of Engineer in-charge.Complete with all required accessories of approved brand.(Alu. section Make Jindal, /Glass : Modi, sant gobin)
Providing Material and Labour With Fixing of coloured Powder Coated/Anodized Alluminium section Ventilation using JINDAL Delux series sections or equivalent having Min. Wt 1.20 Kg /Rmt.for Frame and having Louvers of 5 mm thick transperant glass fixed with Aluminium borders and Mosquito Nets including anodized aluminum fixture and fastenings etc.( 2 Tracked) complete as per detailed drawings and directions of Engineer in-charge.Complete with all required accessories of approved brand.(Alu. section Make Jindal, /Glass : Modi, sant gobin)
Providing Material and Labour With fabricating & Fixing of M.S. grills / Gates of required pattern to brick walls / Columns prepared with M.S. flats, angles, Square / round bars, square pipes, at required spacings with necessary cutting, bending, jointing, connecting, welding and / bolting and / riveting and fabricating and erecting in position etc complete for all levels as directed . The rate to include all necessary fixtures, fastening etc & Ceaning with sand paering, Cleaning Weld dots with grinder machine with smoth joint of welding, & also including one coat of primer and two coats of mat finished oil painting etc complete. hold fasts as per detailed drawing and fixing brick walls / coping / columns etc. (Oil Paint Make asian, Narolac/MS Steel Jindal, asian, Tata) (A) Ornamental Grill
Providing Material and Labour With Fabricating & Erecting of Structural Steel Works in required pattern/ design using Structural Steel like ISMC, Box Pipe, ISMB, Angle, Plates/Bright Bars , round pipes,as per detailed design/ drawings/ instructions including Straightening, Cleaning, Derusting,Cutting,bending, Fabricating, Welding, Bolting, riveting Hoisting , jointing, connecting,& Fixing and erecting in position for all levels For Roof work & Side Flashing works Also providing & painting with one coat of zinc chromate primer and two coats of enamel paint of Asian/ Narolac make & shade etc. providing welding electrodes of the approved make and nuts, bolts etc complete with necessary labour, tools, scaffolding, platforms, props, ropes, pulleys , Cost included of furnish and erect at all height, all required Members as per detail ,all expenses derricks, shear legs, staging, & necessary Scaffolding, loading, unloading for the proper completion of the work. Frame work Making frome /Tata, Vizag / asian make & also side support Frame fabrication with Supporting at Roof trusses with fabricating & fixing at Supporting vertical member as per Detail drawing ( Structural steel Make Tata, Vizag / asian )
Providing Material and Labour with laying of Mirror polished Jet Black Granite slab 18-20 mm (Average) thick for Doors / Windows sill & Jams Cladding as per design incl. full moulded round both edge on 10 mm thick cement mortar 1:3 (1 -cement : 3 coarse sand ) jointed with grey cement slurry including rubbing and polishing etc. complete
Providing Material and Labour With Laying Lather finished Kota stone slab 18-20 mm thick (Single piece not more than 150 cm long) for Entrence stair steps and riser as per design incl. finishing the edges in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement : 6 coarse sand) and risers and skirting on 10 mm thick cement Plaster 1:3 (1 -cement : 3 coarse sand ) and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as per direction of Engineer In-charge.
Providing Material and Labour with laying of Lather finished Granite stone slab 18-20 mm thick {Single piece not more than 150 cm long} for stair steps and riser as per design incl. finishing the edges in trade of steps laid on 20 mm thick cement mortar 1:6 (1 -cement : 6 coarse sand) and risers & Skirting on 10 mm thick cement Plaster 1:3 (1 -cement : 3 coarse sand ) and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc & Also Provide Anti Slip Groove on (3 Nos 4mm x 3mm ) Stair Steps as per Drawing . all complete as per direction of Engineer In-charge.
Providing Material and Labour with laying of Lather finished Granite stone slab 18-20 mm thick flooring in Strips (Ramp) as per the drawings and directed by Engineer in-charge over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete.
Providing Material and Labour with laying of 60 cm x 60 cm MATT Vitrified Tiles (9mm thk) (Basic Rate of ₹ 1000/Sq.M) flooring over 20 mm (average) base of cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismantling of existing flooring and jointed with colour cement slurry including finished with flush pointing & cleaning the surface and including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning etc. complete. (Tiles Make- AGL, RAK, Somany, Sunheart)
Providing Material and Labour with laying of 60 cm x 60 cm MATT Vitrified Tiles (9mm thk) (Basic Rate of ₹ 1000/Sq.M) 8 mm thick of approved shade in skirting, risers of steps and dado on 10 mm thick cement plaster 1:3 (1 Cement : 3 coarse sand) and jointed with white cement slurry including filling the joints with Approved Epoxy Grout in 3-4 mm width and10 mm Depth including cost of PVC Spacers, Rubbing, Cleaning etc. complete. (Tiles Make- AGL, RAK, Somany, Sunheart)
Providing Material and Labour with fixing of Roof Top & flashing for roof panel shall be made out of 0.5 mm thick pre coated Gl sheet. The Precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of minimum 120 gsm as per 15:277:1992, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 micron. The PPGI Sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The ridge shall be fixed to the steel members by pop rivet or self drilling/self stitching fastners @ maximum 450 mm cjc along length of capping/flashing etc complete. (This GI Sheet will be supported on structural steel beam with shear studs. & structural steel qty Measured & paid separately.GI Sheet Make JSW,Tata )
Providing Material and Labour and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, Before starting treatment all crack need to fill in bare slab and it should be dust free, after treatment pond testing is must for 3-4 days should be The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.complete in all respect as per the direction of Engineer-in-Charge etc. complete. (Make - Fosroc,Laticrete, Basf, Sika)
Providing Material & Labour and laying of Broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto surface using white cement including rounding off junctions, and sealing with cement vata and extending them upto 15 cm along the wall, clearing with water and oxalic acid etc. as directed.
Providing Material & Labour and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like Toilet sunk slab retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. Before starting treatment all crack need to fill in bare slab and it should be dust free, after treatment pond testing is must for 3-4 days should be The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm For horizontal surface one coat @1.10 kg per sqm. (Make - Fosroc,Laticrete, Basf, Sika)
Providing Material and Labour with fixing of stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.Apx length of railing 123 Rmt)
Providing material and labour for 15mm thick cement plaster in single coat on brick concrete wall surface for plastering above plinth level upto floor two level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry also including providing Fiber mesh at all Horizontal & Vertical juction of Rcc Column/ beam & Brick work as directions of Engineer in charge Complete.
Providing material and labour for 15mm thick cement plaster in single coat on brick concrete wall surface for plastering above floor two level upto floor three level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry also including providing Fiber mesh at all Horizontal & Vertical juction of Rcc Column/ beam & Brick work as directions of Engineer in charge Complete.
Providing material and labour for 15mm thick cement plaster in single coat on brick concrete wall surface for plastering above floor three level upto floor four level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry also including providing Fiber mesh at all Horizontal & Vertical juction of Rcc Column/ beam & Brick work as directions of Engineer in charge Complete.
Providing material and labour for 10mm thick cement plaster in single coat on SLAB ceiling surface for plastering above plinth level upto floor two level finished leven and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry. as directions of Engineer in charge Complete.
Providing material and labour for 10mm thick cement plaster in single coat on SLAB ceiling surface for plastering above floor two level upto floor three level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry. as directions of Engineer in charge Complete.
Providing material and labour for 10 mm thick cement plaster in single coat on SLAB ceiling surface for plastering above floor three level upto floor four level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry. as directions of Engineer in charge Complete.
Providing material and labor for 20 mm thick rough finished cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick rough finishing coat of C.M. 1:1 (1-cement : 1-sand) on exterior brick / concrete work for reciving texture paint's base coat etc. complete. For plastering above plinth level upto floor two level complete. as directions of Engineer in charge Complete.
Providing material and labor for applying Two coats of wall care Putty & two coat of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth as directed by engineer in charge complete. (All Floor) Make: Birla White.Asian Paints, JK Wall Care Putty or equivalent.
Providing material & labour for Wall painting (two coats) with plastic emulsion emulsion paint of approved brand and manufacture on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth as directed by engineer in charge complete. (All Floor) Make: Make-Asian Paint, Dulex, Nerolac, Berger or equivalent.
Providing Material & labour For Two coat of primer and two coats of Pattern Texture Paint on Exterior Surfaces at all heights of surfaces including cleaning, preparing the surface, applying primer - scraping by sandpaper, scaffolding etc. including - (a) All surface preparation, suitable number of base coats required, primers and suitable finishing to the complete satisfaction of the Engineer in Charge, (b) Scaffolding and all leads and lifts,(c) Proper curing in between the two subsequent coats, (d) Touch ups to the paint after the scaffolding is removed, (e) All measurements for paints to be as per IS-1200. f) Minimum Guarantee of Ten Years Waterproofing and Paint performance for all external paints by manufacturer . Make - Asian Paint Apex Createx, Jotun Jotashield Tex Fine OR Equivalent
Providing Material , labour and fixing Chicken Wire Mesh/jali of 25 gauge having 150 mm minimum width at the junctions of Brick Masonry and reinforcement cement concrete members using cement mortar of 1:3 at all height as per direction of Engineer In-charge including cutting, fixing, scaffolding etc. complete.
Providing Material & Labour for 12 to 25mm wide grooves/ notch in plaster at the junctions including finishing the same etc. complete at all height.
Providing Material Labour for Constructing Sandwich Platform (600mm Width) of 18 mm thick Polished Black Granite at top and 30 mm thick Kota stone slab flooring fitting at bottom with cementing Materials / adhesives including making necessary grooves in walls including all labour material of approved quality incl. full moulded round front edge fixed in wall for partition and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing Material & Labour for laying Both side mirror polished Granite stone slab 18 mm (Average) thick of approved quality incl. full moulded round front edge fixed in wall for Urinal partition (1200ht x 600 width shape as per drawing) and jointed with grey cement slurry including rubbing and polishing etc. complete
Providing Material and Labour with jointing in true line and level110 diameter U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to lSI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diameter x 149 mm length x 145 mm height at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement include ing cost of all materials.(Make:Astral,Ashirvad,Suprime)
Providing Material and Labour of Fitter Media 600mm thick directed at the back of abutments,returns and wing walls as per detailed specifications.
Providing Material & Labour for 6 mm thick Lexan Polycarbonate multi wall roofing sheet fixed with hilti screw and rubber silicon sealer and Alluminium strip of size 50 x 3 mm etc complete as directed by Engineer in charge.
Providing Material and Labour for applying of Metallic Paint Thermo plastic Acrylic Solvent base Paint on MS Structure wall surface MS Plate (two coats) to give an required Texture and Shade as per approved Architectural Elevation after thoroughly Spraying the surface to remove all dirt, and remains of loose powdered materials etc complete Including Scaffolding, staging, Spray machine etc.(Make-Asian Paint, Dulex, Nerolac, ICI)
PAVEMENT WORK : Clearing and grubbing road land including uprooting rank Hectare vegetation grass bushes,shrubs,sapling and trees girth up to 300 mm removal of stumps of trees cut earlier and disposal of unserviceable materials (C) By mechanical means in area of light jungle
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pits.) Girth from 300 mm to 600 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pits.) Girth from 600 mm to 900 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pits.) Girth from 900 mm to 1800 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pits.) Girth above 1800 mm
Earthwork for embankment including breaking clods, dressing with all lead and lift and including watering rolling and consolidation of subgrade in layers at O.M.C. to required dry density including filling the depression which occur during the process using power roller 8T to 10T.(B) From Borrow area within 0.5 Km lead
Construction of dowel jointed, Cement Concrete Pavement (Concrete Grade M-40) over a prepared sub base with 53 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including cost of expansion joint, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, M.S. Dowel Bar, Tie Bar, admixtures as approved, curing compound, finishing to lines and grades.
Construction of Dry Lean Cement Concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a pavefr with electronic ensor, compacting with 8-10 tonnes vibratory roller, fininshing and curing.
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.
Construction of Subgrade (Construction of subgrade with approved material obtained from borrow pits (Outside Murrum within any Lead) with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)-For Subgrade Material CBR > 8.
Providing Material & labour for laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. WMM 1st Layer & 2nd Layer as per MORTH Clause : 406.
Providing Material and labour for Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 - Using Concrete Batching and Mixing Plant.
Providing Material and labour for Kerb Painting: Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Providing Material and labour for fixing pre-cast Rubber Dye inter locking concrete block 80 mm thick with grade of concrete M40 pumatic compressed by mechanically pressed and as per approved desing including 35 mm sand layer for levelling and filling the joint with sand in proper line and level. (Make vyara or eqvalent)
Providing Material and labour for fixingof pre-cast Rubber Dye inter locking concrete block 60 mm thick with grade of concrete M30 pneumatic compressed by mechanically pressed and as per approved desing including 35 mm sand layer for levelling and filling the joint with sand in proper line and level.(Make vyara or equivalent)
Providing Material and labour for fixing of Solar road stud (cats eye) of 100x100 mm, die-cast in aluminium, resistant to corrosive effect of salt and grit, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973
Providing Material and labour for Providing and fixing sign boards made out of 2mm aluminium sheet /4mm ACP (Aluminum composite Panel); size size 60 x 60cms. square plus 60 x 20cms rectangular additional plate as as per the design of I RC-67- 2012. Pre treated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with High Intensity Prismatic Grade retro refiectivesheeting of Type-4 as per ASTM D-4956 and latest M.O.S.T.Specifications; 3.6mtr long stand post of Iron Angle 75 x 75 x 6mm / 65NB Circular MS Pipe as required and frame fabricated from suitable size iron angle of 35 x 35 x 3mm; painted with bestquality epoxy coatings in black and white bends. The details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg including excavation, curing etc. complete under the supervision of engineer in charge. A warranty for 7 years for the Retro reflective sheeting from original manufacturer & a certified copy of 3 year outdoor exposure test report from third party test lab for the product offered shall be submitted by contractor. (B) C!ass-B Type-4 Retro Reflective sheeting.
Providing Material and labour for sign boards made out of 2mm aluminium sheet; size 60 x 60cms. square plus 60 x 20cms rectangular additional plate as as per the design of IRC- 67-1977 pre treated with phospheting process & acid etching; coated with one coat of epoxy primer and two coats of best quality epoxy paint; reflectorised with retro refiective sheeting as per latest M.O.S.T. Specifications; 3.1m long stand post and frame fabricated from suitable size iron angle of 35 x 35 x 3mm 75x75x6mm as required painted with best quality epoxy coatings in black and white bends. the details of symbol for each board shall be as per the instruction of engineer in charge. The fixing at site shall be in 1:2:4 CC block of size 45 x 45 x 60cms. for each leg. including excavation curing etc. complete under the supervision of engineer in charge.(A)Engineer Grade(VR)
Providing Material and labour for retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (xii) 60 cm X 45 cm rectangular
Providing Material and labour for retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing (xii) 80 cm X 60 cm rectangular
Providing Material and labour for Road marking with hot applied thermoplastic paints with reflectorising glass beads on bitumin surface providing and laying a hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250gms per sqm area, thickness of 2.5mm is excluding of surface applied glass beds as per IRC:35-2015. The finished surface to be level, uniform and free from streaks and holes. zebra patta /bump patta lane/center line/ edge line/cut patta. The white color marking should provide liminance coefficinet on cemend road shalll be min 130 mcd/m2/lux and Asphalt road shall be min 100 mcd/m2/lux during the service life during the day time. The marking should meet the performance criteria for night time reflectivity, wet reflectivity and skid resista nee as mentioned in the section-15 of IRC 35-2015. Warranty for the Retro reflectivity should be two years.
LANDSCAPE & HORTICULTURE WORK : Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff (A) Loose or Soft soil
Providing Material and labour for Brick work using common burnt clay building bricks having crushing strength not less than 35kg/Sqcm. in foundation and plinth. In cement mortar 1:5 (1 cement : 5 fine sand) (A) Modular
Providing 20 mm thick double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement: 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trove! including scaffolding curing etc. complete.
Providing Material & Labour for laying of PCC 1:3:6 (1-Cement : 3- coarse sand : 6- hand broken stone aggregates 40 mmnominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block 30cm length,30cm height and 15cm thick of M250 grade concret as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete. (Brands: Vyara, Alcock)
Providing and laying polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A) 25mm thick
Providing and fixing Washed stone grit peeble Plaster with 12 mm cement plaster bedding 1:4 (1 cement: 4 coarse sand ), furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 2 Kg of cement per square metre, top layer 15 mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10 mm nominal size), in panels with groove all around as per approved pattern including scrubbing and washing the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-incharge
Providing and laying Riverwash/natural finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge : Flamed finish granite stone slab Jet Black or equivalent.
Providing and laying Mandana stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge : Colour Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Paver Cobel Granite Stones (100 mm x 100 mmx50mm) over 1:3 cement mortar (1 cement : 3 graded medium coarse sand) bedding of average 1” thickness, floated with thick and neat cement paste with consumption of cement @4.4kg/ sqm and 2 kg /sqm for joints mixed with approved pigment to match the shade of the stone including dressing, rubbing, curing, cleaning etc. complete at all levels and heights. (the rate shall be for the patterns and details provided by the Architect. If required, residues will be provided and no extra amount will be paid for residues to be used to achieve the pattern).
Providing, Supplying and Fixing Pergolas using • Frame of 80x40x3.0 mm thickness crc pipes with required support for outer framing of pergola • Middle members of (20x40x1.6x2.0mm) required define sizes and as per the drawing and the reference image • Footing and fitting of the required metal pillars with a desired angle support in bottom of pergola • Fitting till the height of 10-12 ft from ground level • curves in pergola dimensioned with be as of triangle shaped will be given precisely at site visit • pergola size approx 18mtr x 12mtr x 21mtr curved from edges and triangular in shaped pergola designed • Includes of required material with all labor charges, fitting, transport, color work etc
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).
Carting of soil from inside plant area, including to loading , unloading and transport complete, as directed.
Supplying, Spreading of sludge, dump manure and/or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Pongamia pinnata
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Bauhinia variegata
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Lagerstoemia flos reginae
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm).Samanea saman
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm).Erythrina variegata
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Gliricidia sepium
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Cassia fistula
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Tamarindus indica
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Tabebuia rosea
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Cassia javanica
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Alstonia scholaris
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm).Markhamia lutea
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Terminalia catappa
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Tabebuia argentea
Planting saplings of plants/ trees in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer, insecticides/pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Big Trees (The height of plant shall be considered as 8'-10’ and girth size 60mm-80mm). Millettia peguensis
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed. 1) Pandamus Baptisti "variegated"
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.2) Cymbopogon Cytratus
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.3) Ficus Nitida
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.4) Hamelia Patens
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.5) Ixora Singaporensis
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.6) Pennisetum Setaceum
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.7) Pennisetum Setaceum "cuprus"
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.8) Hibiscus variegated
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.9) Cocolaba Unifera
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed.10) Adhotoda Vasica
Planting the hedges/shrubs approx 10-12 plants per sq mtrs, border plants as mentioned below including making pits/trenches suitably to implant shrubs, including filling the fresh earth and manure and maintaining the same for Two months involving all the operations like multching , de- weeding ,hoeing, forking , application of chemical fertilizer ,insecticides / pesticides and trimming in proper shape.Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 0.15 m dia and 0.15 m deep. Shrubs approx 2'-3' height and girth size 8mm-12mm: as directed. 11) Jatropha integring
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Wadelia Trilobata
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Senecio Confusus
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Caryssa Macrophylla "nano"
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Asystacia Gangetica
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Portulaca Grandiflora
Planting saplings of ground covers in the proper beds as prepared , and maintaining the same for Two months by involving all the operations like multing, de-weeding , hoeing , forking, watering and application of chemical fertilizer , insecticides / pesticides etc. for the following trees/ plants (the pit shall be filled with fresh soil and manure, i.e as stacked at site,Digging holes in ordinary soil and carting away the excavated earth and refilling the holes with the fresh soil mixed with manure or in the ratio of 2 : 1 by volume . the excavated earth shall be placed within premises at required place, rolling, levelling, watering and compaction etc. in required gradient complete as directed.Holes 1.2 m dia and 1.2 m deep. Ground Covers approx 6020 nos. and min. 6" height and girth size 5mm-8mm: Alternauthera Bettaikiana
FIRE FIGHTING WORKS: (A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) (B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 2850 Ipm at 88 m Head
(A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-’F' insulation, conforming to IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 2850 Ipm at 88 m Head
(A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 HzAC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F’ insulation, conforming to IS : 325. (D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads. 300 Ipm at 88 m Head
Supplying, installing and commissioning of Bourdon type Pressure gauge (150mm dial) with gauge cock - range 0-25 kg/sq.cm(g).
Supplying, installing and commissioning of Pressure switch (2SPDT) with needle valve.
Supplying, installing and commissioning of Exhaust pipe - 150 mm dia M.S. 'B' class pipe with Rockwool insulation & 24SWG aluminium sheet cladding. Including MS supports
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 250mm nominal dia (wall thickness 6.3mm)
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200mm nominal dia (wall thickness 6.3mm)
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm nominal dia
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm nominal dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 200mm nominal dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm nominal dia
Supplying, installing and commissioning of Cast iron wafer type lever operated butterfly valve conf. to IS: 13095, PN-16 with fittings, flanges, nut, bolts & washers, etc. MOC of the Body & disc shall be CI as per IS:210 FG200, EPDM / Neoprene seat, carbon steel (EN8) shaft and nylon / Teflon bearing. Valves exceeding 150 mm dia shall be gear operated. 150mm nominal dia
Supplying, installing and commissioning of Cast iron wafer type lever operated butterfly valve conf. to IS: 13095, PN-16 with fittings, flanges, nut, bolts & washers, etc. MOC of the Body & disc shall be CI as per IS:210 FG200, EPDM / Neoprene seat, carbon steel (EN8) shaft and nylon / Teflon bearing. Valves exceeding 150 mm dia shall be gear operated. 100mm nominal dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 200mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,sheet with 3 mm dia holes with stainless steel flange. 200mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304,sheet with 3 mm dia holes with stainless steel flange. 150mm dia
Providing, fixing, testing and commissioning of air-cushion tank (air vessel) 350mm dia. & 1500mm high with dished top, made of 8 mm thick M.S. sheet and 10 mm thick dished ends with 25mm dia. brass air release valve (ball type).
Providing, fixing, testing and commissioning FM approved Fire Pump test Flow Meter, venturi / magnetic type, reading in m3/hr or GPM, suitable meter range, suitable for maximum working pressure 25 KG/SQCM , in-line installation as shown in drawings and of approved make as specified. 200mm Dia
Providing, fixing, testing and commissioning FM approved Fire Pump test Flow Meter, venturi / magnetic type, reading in m3/hr or GPM, suitable meter range, suitable for maximum working pressure 25 KG/SQCM , in-line installation as shown in drawings and of approved make as specified. 100mm Dia
Supply, installation, testing & commissioning of Flexible connections for pumps 200mm Dia
Supply, installation, testing & commissioning of Flexible connections for pumps 100mm Dia
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 200mm nominal dia (wall thickness 6.3mm)
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm nominal dia
Providing, laying, testing & commissioning of ’C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80mm nominal dia
Providing, laying, jointing and testing in excavated trenches the following sizes of ductile iron K-9 class , 6.8mm thickness pipes (6mtr per length) with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. For Underground Piping , excavation and refilling will be paid separately 200mm nominal dia
Providing, laying, jointing and testing in excavated trenches the following sizes of ductile iron K-9 class , 6.8mm thickness pipes (6mtr per length) with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers including excavation in all kind of soil, refilling, ramming, shoring, removing the excavated surplus material, providing adequate support to the pipe and making good the same complete as required. Rate shall include for dewatering necessary to execute the work. The pipe shall not be less than 1.0 m below ground level at any point. For Underground Piping , excavation and refilling will be paid separately 150mm nominal dia
Wrapping & Coating of Underground Pipe with pypcoat tape by thermo fusion process and surface preparation by applying cold primer (bitumen) 200mm nominal dia
Wrapping & Coating of Underground Pipe with pypcoat tape by thermo fusion process and surface preparation by applying cold primer (bitumen) 150mm nominal dia
Supplying, installing and commissioning of Cast iron wafer type lever operated butterfly valve conf. to IS: 13095, PN-16 with fittings, flanges, nut, bolts & washers, etc. MOC of the Body & disc shall be CI as per IS:210 FG200, EPDM / Neoprene seat, carbon steel (EN8) shaft and nylon / Teflon bearing. Valves exceeding 150 mm dia shall be gear operated. 150mm nominal dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 200mm nominal dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 150mm nominal dia
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
2 lengths of 15 Mtr long, 63mm dia RRL hose as per IS:636 Type B with instataneuos couplings and Hoses shall be stored in side the hose cabinet.
Providing and Fixing SS-304 , 63 mm dia instantaneous pattern branch short pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 1 no. SS-304 short branch pipe with nozzle
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Supplying, installing and commissioning of fire brigade Siamese connection of 4 way with 4 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. Non-return valve etc. complete. Piping to be considered as per the approved route at site.
Supplying, installing and commissioning of fire brigade Breeching connection of 2 way with 2 nos. 63 mm dia. built - in Gun metal Non- return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to fire water tank. Qouted rate shall be included with C.I. Butterfly valve etc. complete.. (For fire tank filling)
Supplying, installing, testing and commissioning of 25mm dia GM air release valve with copper alloy globe valve.
Supply installation testing and commissioning of MS Steel Structure for supporting all types of fire pipe dia from 25mm to 200 mm.
Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (Gas Cartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with dry powder, ISI marked confirming to IS:15683 : 2006 complete with standard discharge valve with tube, CI bracket for wall mounting. 9 kg
Providing & fixing ISI marked (IS:2878) portable CO2 type fire extinguisher type4.5 kg capacity. Including valve, discharge hose of not less than 10 mm dia & 1 M long complete in all respects including initial filled with CO2 gas confirming to IS:307-1966 & filled to a filling rate of not more than 0.667 and wall suspension bracket.
Providing & fixing 9 Ltr. Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked/ approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and conforming to IS:910.
Providing & fixing ISI marked portable chemical fire extinguisher, water (gas pressure) type capacity 9 litres conforming to IS: 2878 with gun metal cap and nozzle and complete in all respects including initial fill and wall suspensionbrackets. (Water Type CO2 type - 9 L. Capacity as per IS:15683)
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and black on the bottom, inscribed with letters '' FIRE'' in black and gold with fire sand. The scope shall also include the stand for mounting the sand bucket as per IS:2546
Supply & Installation of M.S stand & canopy for housing 2 nos of sand buckets of 9L capacity painted with red.
Providing & fixing of FRP MOBILE FOAM TROLLEY 200 Ltrs. Stored Pressure Type Controllable discharge mechanism applicable.
Making all liasoning work for getting provisional & Final CFO NOC, as filling necessary applications, submission of forms for approval to the municipal authorities, depositing and making channels for the necessary fees and other amounts as required for getting the premises / installations inspected and approved and all other formalities required till the sewer / storm water connection is obtained. All the expenses incurred in this regard shall be borne by the Contractor, except for the payments to be made for any security deposits which will be reimbursed on production of original voucher.
WATER SUPPLY, SANITARY & DRAINAGE WORKS : Supply,checking, storing and fixing S. S. sink, single bowl with tap point on wall / counter comprising of Concealed type brackets fixed to wall with adjustable clamp to push against counter rim,40 mm heavy plated C.P. waste coupling JAQUAR(ESSCO)-ALE-544NFT fitting without pop-up,with flexible PVC pipe with connector,CP swan neck sink faucet model JAQUAR(ESSCO)-MQT-522AKN Painting brackets with two coats of white enamel paint over one coat of primer,table mounted / wall mounted. Kitchen sink with drain board)(model :Nirali-olympia or equivalent)
Supply, checking, storing and fixing in position European water closet comprising of Wall hung European W.C. MODEL JAQUAR(ESSCO)-MVS-WHT-951SPP in white colour, on approved type of chairs, flushing tank MODEL:JAQUAR(ESSCO)-WHE-WHT-183T as directed,C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks MODEL:JAQUAR(ESSCO)-MQT-526KN for flushing tank,C.P. brass 2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN ,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with brackets and accessories in position,Necessary pipe connection to PVC / PP / CI soil pipe,Painting bracket with two coats of white enamel paint over a coat of primer.
Providing, fixing, testing & commissioning of viterous china Indian type (Orissa pattern) water closet MODEL:ECS-WHT-451 set in cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 stone agrregate 20 mm nominal size) with 100 mm dia C.I. deep seal trap,built-Metropole flush Valve (Jaquar-FLV-1085NSQ) and connection pipe C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube,2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN including cutting and making good the wall & floors complete as required.
Supply, checking, storing and fixing in position European water closet comprising of Anglo Indian W.C. MODEL JAQUAR(ESSCO)-ECS-WHT-355PNPP in white colour, on approved type of chairs, flushing tank MODEL:JAQUAR(ESSCO)-WHE-WHT-183T as directed,C.P health faucet MODEL:JAQUAR(ESSCO)-ALE-ESS-583 with required length of flexible tube, clamp and bracket for fixing to wall,15 mm C.P. brass heavy quality angle stop cocks MODEL:JAQUAR(ESSCO)-MQT-526KN for flushing tank,C.P. brass 2-way bib cock MODEL:JAQUAR(ESSCO)-MQT-512ANKN ,Solid bakelite water closet cover and seat with C.P. hinges and rubber buffers,Fixing W.C. unit with Fixing accessories in position,Necessary pipe connection to PVC / PP / CI soil pipe,Painting bracket with two coats of white enamel paint over a coat of primer.
Supply, checking, storing and fixing Under Counter wash hand basin MODEL:JAQUAR(ESSCO)-MVS-WHT-801 ith ,32 mm heavy plated C.P. waste coupling JAQUAR(ESSCO)-ALE-544NFT fitting with pop-up,32 mm heavy plated C.P. bottle trap JAQUAR(ESSCO)-ALE-733ML 190X125 with cleaning eye with extension piece and wall flange,Painting brackets with two coats of white enamel paint over one coat of primer,CP Basin Faucet JAQUAR(ESSCO)-MQT-508KN with 15 mm C.P. brass heavy grade flexible inlet connection with C.P. nut (minimum length 450 mm) made to measure.
Supply, checking, storing & fixing CP Over Head shower MODEL:JAQUAR(ESSCO)-EOS-542A complete as per instructions of the engineer-in-charge.
Supply, checking, storing & fixing CP single lever wall mixer MODEL:JAQUAR(ESSCO)-ORB-105055K with Concealed body Shower Valve MODEL:JAQUAR(ESSCO)-ALE-055 & Bath Spout MODEL:JAQUAR(ESSCO)-SPE-101429 complete as per instructions of the engineer-in-charge.
Supply, checking, storing & fixing C.P. brass towel ring MODEL:JAQUAR(ESSCO)-AEC-1121 Round to PVC cleats with C.P. brass screws including cutting and making good the walls wherever required .
Supply, checking, storing & fixing C.P. brass angle valve for basin & Sink MODEL:JAQUAR(ESSCO)-MQT-526KN, of approved quality conforming to IS:8931 for a) 15mm Nominal Bore
Supply, checking, storing & fixing C.P. brass Long Body bib cock MODEL:JAQUAR(ESSCO)-MQT-512KN of approved quality conforming to IS:8931. a) 15mm Nominal Bore
Supply, Checking, Storing and fixing vitreous Large flat back urinals Model No. JAQUAR-URS-WHT-132530 or Equivalent with Conceal Flushing Stop Cock MQT-514AKN or Equivalent in white colour with concealed type wall hanger or special bracket in wall and hinged type C.P. dome gratings.C.P. flush pipes from auto flush, spreaders, full bore inlet caps as necessary made to measure.C.P. waste pipe and Speader under each urinal pan, leading to the CP bottle trap Model No.JAQUAR-ALD-CHR-769L300*190 or Equivalent below and painting with two coats of white enamel paints and cutting and making good the walls wherever require.
Supply, checking, storing & fixing straight/offset type Macfit single body push fit type WC Pan Connector Jaquar-ZPS-WHT-VB01 with factory supplied spring loaded seal guard with integrated single mould sealing fins made of flexible EVA Body, including bush/adaptor for use with CI Pipe as supplied with Pan Connector (For European water closet)
Installation testing and commissioning self contained pressure type water coolers suitable for operation on 230 voltage - 10% single phase AC supply and generally confirming to the requirements of IS :1476/78 having following nominal cooling capacity at an ambient temperature of 30 deg.c and drinking water inlet temperature of 35 deg c and drinking water outlet temperature of 13.5 deg. complete with compressor over head protector, thermostat and steel tank. 40 Ltr. Cooling and 80 Ltr Storage.Cap.(Make:Voltas,Blue Star,Usha)
Drinking Water RO - Providing & fixing Wall Mounted RO plant with UV Technology I.S.I marked,C.P brass push cock, inlet float valve with all plumbing and electrical accessories, inlet, outlet, overflow and PVC drain out connection. Flow-2 LPM(Make:Aquaguard,Eureka Forbes,Kent)
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 75 mm
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 110 mm
Providing and fixing PVC SWR Pipe confirming to IS 13592-92 TYPE B and fitting as per IS 14735-99 for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance, cutting, chases /holes in walls/floors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 110 mm 150 mm
Providing and fixing PVC Agri 6Kg/cm2 and fitting for SOIL & WASTE water discharge, including all fittings with and with out inspection doors, including supports brackets as per supplier specification and distance,cutting, chases/holes in walls/flors/slab etc. (Pipes to laid in Toilets)(Make:Astral,Ashirvad,Suprime) 50mm
Providing and fixing PVC traps of self cleansing design with water seal not less than 50mm with or without vent, including setting the trap in 1:2:4 cement concrete etc. complete. The trap shall be `P' type as required. Trap with 100 mm inlet and outlet 75mm/100mm dia.(Make:Astral,Ashirvad,Finolex)
Providing and fixing in position Multi Floor Trap/Plain Floor Trap self cleansing design moulded or fabricated with 50 mm water seal conforming to IS:14735-90 including setting the trap in 1:2:4 cement con'crete etc. (Make:Astral,Ashirvad,Finolex) (100mm Outlet)
Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating) complete as required.(Make:Neer,Weimer) 300x 300 mm (75mm outlet pipe dia )
Supply , installation , testing and commissioning rain water Sidewall Parapet CI Body With Aluminium Grate With 4 SS Screw Drains ,size as per drawing required depth with Making Khurra with Proper water proofing and fixing the fittings (Horizontel/vertical arrangment grating) complete as required.(Make:Neer,Weimer) 450x 450 mm (100mm outlet pipe dia )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic & Flushing ) (Inside Toilet) 15 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic & Flushing ) (Inside Toilet) 20 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic & Flushing ) (Inside Toilet) 25 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Cold Water Lines ( Domestic & Flushing ) (Inside Toilet) 32 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 25 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 32 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 40 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. For Cold Water Lines ( Domestic & Flushing ) (In shaft & Terrace & Exposed On wall) 50 mm nominal outer dia Pipes ( SDR 11 )
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC high bonded solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(The pipe length inserted in the fitting shall not be measured for payment) For Cold Water Lines (Inside Shaft & Terrace & Riser)(Make:Astral,Ahirvad,Finolex) 65 mm nominal outer dia Pipes ( SCH 40 )
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 20 mm dia
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 25mm dia
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 32mm dia
Providing, fixing and testing of heavy quality CPVC BALL Valves of 15 Kg / sqcm pressure with all necessary unions and nipple collars fixing on CPVC lines.(Make:Astral,Ahirvad,Finolex) 50mm dia
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.(Make:Sant,Zoloto,leader) BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 65 mm dia.
Providing and fixing Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for cold / hot water circulation including insulation as specified.(Make:Sant,Zoloto,leader) 65 mm dia.
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. 25 mm outer dia
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. 32 mm outer dia
Providing & laying UPVC pressure pipes of 10Kg/Sq.cm pressure rating class V (IS : 4985-2000) including fittings, tees, bends, clamps, coupling and adaptors supports, and jointing with solvent joint, testing and necessary earth work in excavation, backfilling, disposal of surplus earth with a lead up to 100m complete, compaction and consolidation Including sand bedding all around UPVC pipe & fittings and thrust blocks at bends as per standard design. 40 mm outer dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm outer dia
Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 150 mm dia
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 200 mm dia
Providing, laying, jointing and testing heavy quality DWC (Double wall Corrugated ) under ground application pipes for Sewer and strom line with Snap-Fit Coupler with Rubber Ring / In-line Socket Molded Coupler / Socket-Spigot Arrangement fittings of SN8 class of approved make laid to required alignment and slope trenches inclusive of excavation in all soil types, bailing or pumping out water from trenches, shoring, whenever necessary testing, refilling, in layers, ramming & consolidation, removing away the surplus earth & spoils, dumping it on site or carting away to lead of 100 meters as directed incl. 250 mm dia
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design b)150 mm dia diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design c) 200mm dia diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes /UPVC /DWC Pipes including bed concrete as per standard design d) 250mm dia diameter
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type.
Constructing brick masonry manhole in cement mortar 1:4 (1cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 R.Mt. for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (3) C type depth 2.25 R.Mt. for 150mm diameter sewer.
(I) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No.24.27 (I) for depth from 0.9M to 1.5M.
(II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
(III) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. or Part thereof over item No. 24.27 (III) for depth from 2.25M to 3.15M.
Providing and fixing cast iron steps of size 500mm x 150mm x 22.5mm and painting with two coats of Anti-corrosive paint etc. complete.
Constructing Brick masonry road gully chamber 500mm x 450mm x 600mm including 500mm x 450mm C.I. horizontal grating wih frame complete. (more than 10 ton)
Constructing brick masonry road gully chamber 1100mm x 775mm including 500mm x 450mm (C.I. horizontal grating with frame and vertical grating complete.) (more than 10 ton)
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with briocks having croshing strength not less than 35Kg. Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line. (more than 10 ton)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 R.Mt. depth below ground level. All type of soil 300 mm dia R.Mt.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Providing and fixing factory made precast RCC perforated drain covers,having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
HYDROPNEUMATIC SYSTEM AND VARIOUS PUMPS Variable Speed Hydro-booster System for domestic water supply : Compact self contained Hydro-booster system comprising of following : In-line, vertical multistage, centrifugal clear water pumps with SS-316L /304 casing, S.S 3I6L impeller and SS-304/316 shaft, SS-316L/C.I. Base CED coating & head TEFC IE4/IE5 magnetic motor (IE5 is preferable motor for Suitable duties, if duties is not available in IE5 motor then you can quote pump with IE4 motor) with mechanical seal with Company fitted with company compliance certificate. Vendor to submit performance curves and technical catalogue with all GA Drawing of the proposed model for review and information.Panel mounted PLC and HMI Based multi pump controller with large graphical display with VGA 240 x 320 pixels and variable frequency drive (VFD) integrated in a Panel/Inbuilt with pump motor with IP54 class with pressure sensor transmitter (each pump each VFD), diodes to indicate pump ready, pump running and fault and capable to communicate with other controllers following MODBUS-RTU or BACNET Class-2 protocol through RS485 port. All alarms should be displayed in the controller. System should be equipped with dry running protection by both, reputed make Float (NO/NC) having 20 Mtrs Submersible Cable installed in the Tank & 0-10V DC Device installed on Suction Header. Indication of all type of faults / on-off status / electrical parameters shall be available on panel and central IBMS monitors. On-off operation for all pumps shall be available on BMS system.Global / Equivalent Make Pre-charged diaphragm pressure vessel with 3 years warranty from manufacturing date and company tested replaceable membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts etc. complete (size of pressure vessel shall be following capacity or as per manufacturer recommendation). Vessel Shall be pre-charged with Nitrogen as per respective Pump Head. Each Vessel shall be installed with 2 1/2" SS 304 Glycerine Filled Manometer on Top.Set of accessories such as SS 304 / MS with CED Coated headers for suction and discharge, control valves, non return valves, pressure transducers, pressure gauge, inter connecting power and control cabling etc. complete.Capacity of Pilot pump (Working) - 200 LPM Capacity per pump - 300 LPM Head - 50m Pressure vessel - Min. 100 liters or as per manufacturer recommendation 1 Set = 3 Nos. Pump (1Pilot Working + 1 Working + 1 Standby - cascade operation) Suction head - flooded positive suction Supply, Installation, testing & commissioning
Supply, installation, testing & commissioning of Submersible Multi stage borewell pumps (Sutable for 150mm dia )connected to submersible motor (The motor shall be IE3 watertight according to IEC class IP 68, and incorporate class F, insulation materials to withstand a continuous operating temperature of 155 deg C) for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit Or Auto Coupling with rubber diaphragm and bend, vertical discharge pipe,Control Panel,Cable,Column pipe etc complete to the entire satisfaction of the Engineer-in-charge. Flow-30000 Ltr/Hr, Head-50m
Design,Supply installation, testing and commissioning of water treatment plant comprising of FRP body pressure sand filter, multi media, carbon filter,chlorination, softner plant etc. accrording to input water quality/analysis. softner plant consisting of fiber glass reinforced plastic (FRP) tank,dosing pump for disinfection, filter media, resins, piping, isolation valves, instruments supports.The scope shall include interconnection Cpvc piping, valves, instruments, back wash arrangement,power and control cabling etc. duly complete . (vendor Make: Cleantech,W18 tech,Aqua Drop) ( Pump make : wilo & Grundfos) Capacity:12 m3/hr Following shall be the Parameters for design of Treatment Plant. Acceptable Limits 1.Turbidity (NTU) 1.0 2. Colour 5.0 3. Taste & odour Unobjectionable 4. pH 7.0 – 8.5 5. Total Dissolved Solids 500 mg/ltr. 6. Total hardness as CaCO3 200 mg/ltr. 7. Chlorides 200 mg/ltr. 8. Sulphates 200 mg/ltr. 9. Fluorides 1.0 mg/ltr. 10. Nitrates as No3 45 mg/ltr. 11. Calcium 75 mg/ltr. 12. Magnesium <=30 mg/ltr. 13. Iron 0.1 mg/ltr. 14. Mn & Cu each 0.05 mg/ltr. each 15. Zinc 5.0 mg/ltr. 16. Bacteriological standard (E.coli) <100 mg/ltr. 17. Total Suspended Solids <30 mg/ltr. Notes:pumps with SS-316L casing, S.S 3I6L impeller and SS-304 shaft, SS-316L/C.I. Base CED coating & head TEFC IE4/IE5 magnetic motor (IE5 is preferable motor for Suitable duties, if duties is not available in IE5 motor then you can quote pump with IE4 motor). Contractor to submit performance curves and technical catalogue with all GA Drawing of the proposed model and take a approval from architect/Consultant.
ELECTRICAL WORKS: Providing and erecting ISI Marked 3core 185 Sq.mm XLPE insulated 11 KV armoured cable Aluminium conductor to be laid on wall with clamps or in provided cable trench / pipe approved manner as directed.
Providing and erecting cable end terminatation kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 185 Sq.mm (A) Outdoor type
Providing and erecting cable end terminatation kit, heat shrinkable Push on type Densons/ Raychem/ Elastimold make suitable for 11 KV XLPE cable 3core 185 Sq.mm (B) Indoor type
Supply, Installation Testing and commissioning of 11KV/433V 400KVA Outdoor Type USS with 400A HT VCB Section, 750 KVA Distribution Transformer (DRY TYPE WITH OFF LOAD TAP LINKS, TAP OF +/- 7.5 % IN STEP OF 1.5) Section and LT Section with 800A FP MOTORISED MICROPROCESSOR BASED MCCB - 50KA Section complete as per detailed Technical Specifications
SUB-STATION ACCESSORIES AS PER LOCAL NORMS - Safety Signages, Fire Extinguisher, First Aid Kits, Hand Gloves, Rubbers Mats etc
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated indoor type cubical panel board having IP-64 protection made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions with necessary supporting angles, flats including cutting, bending, drilling, welding, riveting with internal partitions & cable alley as per requirements & instruction of engineer-in-charge with erection, supplied switch gears, BUSBARS, with suitable size of inter connecting PVC copper wire / copper-aluminium strips, rubber grommets, rib, bakelite control fuses for measuring instruments, earth bus & earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles with locking arrangement and rubber gasket complete. The Panel shall be painted with epoxy powder coating. (The rates includes the cost of switchgears, bus bars, inter connecting mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured excluding base beams) The panel shall be supplied with following approved manufacturers as per attached SLD - MAIN LT PANEL (as per attached Single Line diagram)
2X250KVA DG AUTO SYCH, AUTO LOAD SHARING PANEL (Specification as above & as per attached Single Line diagram)
Dormatory - Main LT Panel (Specification as above & as per attached Single Line diagram)
Ware House - Main LT Panel (Specification as above & as per attached Single Line diagram)
Service Station - Main LT Panel (Specification as above & as per attached Single Line diagram)
Admin - Main LT Panel (Specification as above & as per attached Single Line diagram)
Charging Station - Main LT Panel (Specification as above & as per attached Single Line diagram)
CNG-Diesel Pump : Main LT Panel (Specification as above & as per attached Single Line diagram)
External Lighting Panel (Specification as above & as per attached Single Line diagram)
High Mast - Lighting Control Panel (Specification as above & as per attached Single Line diagram)
185KVAR APFCR PANEL (Specification as above & as per attached Single Line diagram)
METER PANEL FOR COMMERCIAL BLOCK (Specification as above & as per attached Single Line diagram)
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) - Three phase 8 way SS Double door for horizontal single phase outgoing
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) - (D) Single phase 6 way SS Double door
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark - SP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 6 to 32 Amp. - DP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity 40Amp. - DP MCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 6 to 32 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 40 Amp.
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box having following capacity 63 Amp.
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 25 Amps.DP
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 40 Amps.DP
Approved make ELCBs / RCCBs conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable for operation on single phase 240 V. having characteristic of quick action & tripping with all advance feature & do not incorporate any electronic component. for following Max. rating erected as directed 63 Amps.DP
Supplying & erecting approved make RCCB + MCB (Electro magnetic type only) working on residual current device having 6 KA short circuit breaking capacity and 30 mAmp. Sensitivity & 30 mili sec. tripping time conforming to IS 12640 test knob facility trip free mechanism operating for rated leakage at nominal ten volt, complete erected including all materials lugs screws etc. completed. 32A DP
Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards as specified in 8.1, 8.2 & 8.3 1.4KV Protection level FP ,Class 'I', (Imax-40KA, 8/20µS) LEGRAND Cat no. 3938 or Equivalent
1.2KV Protection level FP, Class 's', (Imax-15KA, 8/20µS) LEGRAND Cat no.3943 or Equivalent
1.2KV Protection level DP, Class 's', (Imax-15KA, 8/20µS) LEGRAND Cat no. 3941 or Equivalent
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 125A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 250A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Approved make Four pole moulded case circuit breaker having breaking capacity ICU of 35 KA. at 415 V. having normal current rating up to 400A. with Fixed thermal & magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections & complete erected in existing 16 G.M.S. housing. ICS=100% of ICU only with Sheet metal Enclosure
Providing and erecting metallic vitrified danger notice board for MEDIUM VOLTAGE installation to be erected as per IS.
Providing and erecting metallic vitrified danger notice board for HIGH VOLTAGE installation to be erected as per IS.
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative and operate battery backup 1 channel day clock with 14 memory programme, suitable to operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum & LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in fire proof thermoplastic enclosure & transparent cover erected as required with necessary connection erected as directed.
Providing and erecting approved make light control unit suitable to operate on 230V +20% having ON/OFF delay time of 30-50 seconds and having facility for Auto/manual system having two LDR lens to intensity light having capacity of 5A complete erected on section pillar with pipe and stand. Supplying & erecting power contactor for time switch complete erected as per direction Cat III 4 pole 440V 40 Amp.
Making trench in soft soil of suitable width of 90 cms deep for laying cable or locating the fault all over the run and backfilling the same and making the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of sand above & below cable (16 bricks per meter)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a) 4 core 2.5 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(a-1) 4 core 4 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of following size of cables.(B) 4 core 6 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(c) 4 core 10 Sq. mm
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(d) 4 core 16 Sq. mm
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (A-1) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (B) 3 1/2 core 50 Sq. mm ( 25 Sq.1/2 mm core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables(C) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (D) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (E) 3 1/2 core 120 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (F) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (G) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (H) 3 1/2 core 240 Sq. mm( 120 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (I) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of following size of cables (J) 3 1/2 core 400 Sq.mm ( 185 Sq. mm 1/2 core)
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 4 Sq. mm / 4 core 2.5 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 6 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 3 & 1/2 core 25 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (C) 3 & 1/2 core 70 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (D) 3 & 1/2 core 95 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (E) 3 & 1/2 core 120 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (F) 3 & 1/2 core 150 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (G) 3 & 1/2 core 185 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (H) 3 & 1/2 core 240 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (I) 3 & 1/2 core 300 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated armoured cable complete with out going tails, insulating tape etc for following size of cables. Solderless crimping type Aluminium lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (4) 3 & 1/2 core 400 Sq. mm
Supplying & laying under floor pregalvanised corrosion proof rectangular sheet steel cable trunking of 1.6 mm thick having with stand point load up to 1.33 Ton & free from seepage of concrete of screed water having following size of dimensions and No of compartments (W x D x T) : 150mm x 38mm x 1.6mm with Three Compartments
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.150mm x 150mm x 60/75 mm depth
[C] G.I. Junction cross over box for metal / Al. trunking with duct entry 25mm x 38mm size having epoxy powder coated trap lead with corrosion & rust free having load bearing capacity of 3.6 TONS with adjustable levelling screw of following size.300mm x 300mm x 60/75 mm depth
Supplying and erecting approved make GRP Ladder type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections - Polyester Resin System, Glass Content : 55 – 60 % - Thickness- Rung Sq. Hollow Tube 25mm x 25mm - Fixing of Rung to Side Rail with Thermoplastic Pin & Epoxy Adhesive, Assembly Single Stroke 3 Mtr. Length- Rung Spacing – 300mm - Length of Tray: 3000mm- Support Span – 2500mm, Deflection L/200 or < 10mm whichever is less - Specification Followed NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Oxygen Index – Minimum 30% as per ASTM D 2863 Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (A) Width 150 mm, Side Member “C” Section : 75 x 25 x 25mm with 4mm Thickness, Loading 30Kg./Mtr. With Concentrated Load 70Kg. at center of the span
(B) Width 300 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 60Kg./Mtr. With Concentrated Load 70Kg. at center of the span
(C) Width 450 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 75Kg./Mtr. With Concentrated Load 70Kg. at center of the span
(D) Width 600 mm, Side Member “C” Section : 100 x 35 x 35mm with 4mm Thickness, Loading 90Kg./Mtr. With Concentrated Load 70Kg. at center of the span
Supplying and erecting approved make GRP Perforated type Cable Tray Material – Corrosion Resistant Polyester Flame Retardant U.V. Stabilized Resin System - Manufactured from Pultruded Sections- Polyester Resin System, Glass Content : 55 – 60 % - - Standard Length : 3000mm- Support Span – 1500mm, Deflection L/200 - Specification NEMA FG1 1993- UV Resistant - Flame Retardant – IS 6746 - Appendix K/UL 94, Very Low Flammability - Specification Followed NEMA FG1 1993 Oxygen Index – Minimum 30% as per ASTM D 2863 - Flame Spread (Extent of Burning) – 20mm as per Standard ASTM D 635 - Tensile Strength – 4000 – 8000 Kg/Cm2 as per Standard ASTM D 638 - Flexural Strength – 2500 – 10000 Kg/Cm2 as per Standard ASTM D 790- Izod Impact Strength – 130 Kg/Cm2 as per Standard ASTM D 256- Compressive Strength – 2500 – 5000 Kg/Cm2 as per Standard ASTM D 695- Barcol Hardness – 50 – 65 (D) Width - 150mm, Pultruded “C” Channel with 30mm Sides 3mm Thickness, Loading 15 Kg./Mtr.
(E) Width - 200mm, Pultruded “C” Channel with 40mm Sides 4mm Thickness, Loading 25 Kg./Mtr.
(F) Width - 300mm, Pultruded “C” Channel with 50mm Sides 4mm Thickness, Loading 30 Kg./Mtr.
Fabrication : Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
HEAT / FIRE RESISTANT COATING OF CABLE Supply and application of intumescent based coating on cables/ cable tray using CP 678 firestop cable coating of HILTI make or equivalent. The coating shall have a density in the range of 1.2 to 1.4 Kg/ L. The coating shall be non-toxic, asbestos and halogen free and shall have good mechanical strength. The coating shall comply with IEC 332 part 3 (1992).
Point wiring for Light Point / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in/ on surface on wall/ceiling complete with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.with medium class Rigid PVC pipe and accessories
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (a) 2 wire 1.5 sq. mm
Additional Wire : Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size in (a) with medium class Rigid PVC pipe and accessories Wire : (b) 2 wire 2.5 sq. mm
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling, complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC box covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling ,complete with 6A Modular type switches and following type of accessories erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand copper wires, in following type of pipe to be erected concealed in / flushed on wall/ceiling complete with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic box, single mounting base frame covered with textured/metallic front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed. (a) with medium class Rigid PVC pipe and accessories
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories
Do - As - Above but for 6 A x 5 pin 250 Volt switched socket outlet point at convenient location. ( Plug & Switch can be together or at different location )
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [II] For 6/16A Plug with 2-2.5 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [III] For 16A Plug with 2-4 sq.mm Cu. Wire (a) with medium class Rigid PVC pipe and accessories
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (B) 50 mm Dia. (2.5Kg/6RMT)
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (D) 75 mm Dia (5.5 Kg / 6RMT)
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3) to be erected at road crossing on or floor as directed for laying of cable. The pipes as following size of dia & weight per 6 mtr. (E) 90 mm Dia (8.0 Kg / 6RMT)
Supplying & erecting Electronic Type Cordless Call Bell erected on PVC/Metal board having portable bell push working on D.C. & bell on 230V A.C. supply with cells / battery
Computer : Power Plugs 1 no. universal plug-switch combined + 1 Nos swithc for Below table 2 nos. 6A 5 pin Plug as below Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket erected on PVC / Metallic box, single mounting base frame covered with textured / metallic front plate modules erected on / in wall / ceiling with following type accessories Cat. III + Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed in / on surface of wall / ceiling complete with Modular type switch & 5 pin Plug erected on PVC / Metallic box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug with 2-1.5 sq.mm Cu. Wire (Car.iii) + [II] For 16A Plug with 2-2.5 sq.mm Cu. Wire (Car.iii)
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 4 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with following sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 6 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected in / on wall / ceiling with 2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size : 4 wire 10 sq. mm
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. It should be BLDC motor -5, 320RPM, 30-35W 5-Star rating Power saving Fan
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/ O.20, 3 core flexible wire with earthing.
Supplying & erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers & square frame.
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [C] 380 mm dia 1400 RPM
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM [D] 450 mm dia 900 RPM
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Internal light fixtures of 1200mm long LED Tube light (20W) IP-65 with 110LPW white color Aluminum extruded body with PC transperant diffuser diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Internal light fixtures of 600mm long LED Tube light (14W) with 110LPW white color Aluminum extruded body and milky white diffuser.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 Surface Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 Surface Mounted 16W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp with inbuilt driver and driver. LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Recessed Mounted 10W LED down light with White Aluminum dia cast, powder coated housing, reflector, PMMA Deep Down LG7 Diffuser with LED lamp and driver.LUMEN EFFICACY >90lm/W / 110lm/W, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Recessed Mounted 18W LED down light with White Aluminum dia cast , powder coated housing, reflector, PMMA Deep Down LG7 Diffuser cover with LED lamp and driver.LUMEN EFFICACY >110lm/w, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of 600x600mm LED Panel Light of 42W LED Lamp White CRCA Luminaire Body and Micro prismatic diffuser, LUMEN EFFICACY > 120lm/w, PF >0.90, THD <20%,SPD 4kv CCT 6000K, powder coated housing, reflector, Diffuced PC cover with LED Panel and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Suspended Hi-Bay IP-65 100W LED light with Aluminum Die cast/Extruded housng with LED lamp and driver.LUMEN EFFICACY >100lm/W, PF >0.90, THD <20%, CCT 6000K, with Liquid Cool technology Make : Trilux, Wipro, Philips, Tucana
Supply,installation, testing and commisioning of Surface Mounted IP-65 100W LED light with Aluminum Die cast/Extruded housng with LED lamp and driver.LUMEN EFFICACY >100lm/W, PF >0.90, THD <20%, CCT 6000K, Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 -IK 07 ,10-12W LED Bollard light with die cast aluminum die cast powder coated housing, reflector,with LED lamp and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of Wall Mounted IP-65 2x6W LED up-down light with die cast construction, Double reflector, toughened glass cover with LED lamp and driver.-PF>0.9 ,THD <20% ,Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 3-6W LED foot light with die cast aluminum 150-200 mm long Recessed / surfaced, IP-65 powder coated housing, reflector, toughened glass cover with LED lamp and driver. Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 3-6W LED Spike light with die cast aluminum 300 mm long spike, powder coated housing, reflector, toughened glass cover with LED lamp and driver.Make : Trilux, Wipro, Philips
Supply,installation, testing and commisioning of IP-65 35-40W LED Each LED Lmap Post made up of die cast aluminum, powder coated IP-65 housing, reflector, toughened glass cover with LED lamp and driversuitable for mounting on 3.0 Mtr FRP Light Pole. Make : Trilux, Wipro, Philips, K-Lite
Supply of approved make GRP / FRP Pole having following specifications: GRP Light Pole made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. The pole should be in one piece and tapered round in shape, having smooth finish and should be totally free from corrosion as well as non conductive & shock proof Pole should be provided with FRP Anchor Base and it should be heavy duty, or MS Material duly painted with Epoxy paint. Pole should be flame retardant as per IS 6746. Resin used shall be UV resistance and pigmented. A highly weather resistant polyurethane coating shall be applied to the pole after applying suitable primer system that ensures proper adhesion of the paint. Minimum coating thickness shall be 80 to 100 micron. Deflection of the pole shall not exceed more than 10% of the length of pole for the given load“? Pole should be generally made as per the dimensional data, performance criteria and some interchangeability features of poles as per standard ANSI C 136.20 latest version or ASTM D 4923/01 . The size of pole and type of installation are as below . [D] Overall length of 4 Mtr. Average Thickness: 7mm. Top/ Bottom OD Dia A/F 89/145 mm ± 2mm approx. Approx. Weight of Pole 19 kg approx. (Without Base) Anchor Base (Size 250X250 & 12mm th.)
High Mast : Supplying, erecting, testing, commissioning approved make M.S. Polygonal High Mast Pole having following general Specification. (a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot deep galvanised minimum 65/86 micron (as per IS 01461) Lantern carriage with ring and rubber lines for erection of luminaries of suitable site. (b) Maximum telescopic section not more than four (c) Double drum gear pipe motorised winch with 6mm dia S.S. Rod (For 16 mtr and above size) (d) Approved make L.E.D. aviation light = 1 No. Lighting arrestor = 1 No. with necessary wiring of 2.5 sq.mm 5 core ISI copper cable Unarmoured. (e) Bottom most section suitable for mounting reversible motor and switchgears having door not more than 1400mm x 300mm with waterproof gasket & hinges & locking arrangement. (f) Pole structure comprises suitable size of reversible motor, cable and necessary switchgears. (g) bottom section shall have suitable size of thickness supports ribs foundation bolts nuts etc. (h) Item not comprises the cost of lanterns. (i) Necessary Cement Concrete foundation as per IS including testing & commissioning of the entire structure for following size of High Mast poles [CAT.II] [10] High Mast 30 Mtr. TOP A/F 170 Mm, BOTTOM A/F 610 Mm, No. of Sec. No. - 3, Bottom Thickness - 5 mm, Middle Base Sec. mm - 4 Top Sec. - 4 mm, Size Base Plate - 840 x 32, Foundation Bolt Size M36 x 1200, Qty - 12 Nos., Suitable for mounting Fitting of Light - 20 Nos. Make : Velmont, K-lite, Transrail
Supply,installation, testing and commisioning of 350-400W Flood Light on 35-36 Mtr High Mast with IP-66 Protection, Made up with die cast construction, CRI (Colour Rendering Index): - ≥ 70%, System Efficacy of Lighting fixtures 115Lm/W, Beam angle : -30D, Driver inbuilt Surge withstands capability should be ≥4KV, PF>0.9 ,THD <12% ,Make : Trilux, Wipro, Philips, Panasonic, K-lite
Providing M-20 / 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cms. Deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia x 45 cms) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
Supplying & erecting approved make SMC press moulded composite FRP. loop-in, loop-out approx. 2mm thick box complete with bakelite connector strip 4way & hinged doors having locking arrangements with mounting clamp with nuts, bolts & washers suitable for erection on pole with cable clamps& earth bolt of following size of box.: (b) 250mm x 200mm x 100mm [deep]
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (c) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing, A.C.Plant & Sensitive Computer System(like Automation, SCADA) i.e independent Earthing in normal soil. Length of Pipe : 3.00 mtrs Back filling Compound :2 nos Bags of 25 Kg.
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications. (b)For Electrical installation up to 11 KV in normal soil. Length of Pipe : 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg.
Supplying & erecting of Conventional Lightening arrestor with Test loop and Counter as per IS standard
Providing and erecting required size Copper strip for earthing of H.T. OCB / ACB/ Transformer, LT panel board, Motors etc. using copper clamp.
Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (8) Modem Jack for Computer Open RJ-45 - cat-III
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. (3) Two Pin/RJ-11 Telephone Socket for One Gong Bell - cat-iii
Supplying & erecting push button type telephone instrument having speaker phone Caller ID & hands free dialing system & 30 memories with display system (a) Single line BEETEL/panasonic or equivalent make
Supplying & erecting approved make LAN cable of following size in existing pipe as per direction : [C] CAT - 6
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 10 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 20 Pair
Supplying & erecting Delton or approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs, & wrapped with FRLS PVC tape & sheathed with FRLS PVC or HFFR outer Jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos.of pairs. With necessary connections. (b) Armoured [Jelly Filled] - 50 Pair
Supplying, erecting, commissioning and testing EPABX CMOS microprocessor based system having common features With remote programming & remote dialling having following other common features. (Accord Matrix or equivalent approved make)- Auto Call Disconnector- (Incoming - Local- STD) with programmable timing- External Call forward with DOSA- Walk in Class of service & trunk reservation- Boss ring & call back on No Reply last caller recall CLI- Hot Line with Delay & with No.- Unsupervised Conference- Serial DISA ( DISA with option to dial another No. if Extn. is No Reply)- Programming Flexibility of all features related to timer( 41 Timer)-10 Different group of out going call restriction like 95, 97, 98 etc.Having following capacity. [C] No of Extension 48, No of Junctions 8, No of expandable ports:128, Operators Console - 01 Compatible: ISDN
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark (embossed) RIGID PVC PIPES of following size complete erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following type of erection.2) For erecting concealed in RCC / Brick wall/slab or Open along with continuous fish wire to draw mains, laid in approved manner with plastering by cement mortar & finishing the surface to match the wall/ceiling. Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness .
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-6 Cable
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. RG-11 Cable
Providing following type of Modular Type Accessories mounted with pvc / metallic box, single mounting base frame covered with textured / metallic front plate , modules erected with necessary connection. for (4) TV Co-axial Socket outlet
Supply, Installation, Testing and Commissioning of 5 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Indoor IR Eyeball, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, 3.6mm lens, 4 IN 1
Supply, Installation, Testing & Commissioning of 2 Megapixel HD Dome Camera, HD1080p,1/2.7" CMOS, 24 pcs LEDs, 20m IR, Outdoor IR Bullet, ICR, 0.1 Lux/F1.2, 12 VDC, Smart IR, DNR, DWDR, IP66, 3.6mm lens, 4 IN 1 OUTPUT
Supply, Installation, Testing and Commissioning of 16-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 16 Turbo HD input, 16-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Supply, Installation, Testing and Commissioning of 8-Channel Digital Video Recorder recording with 4TB HDD with all require installation and integration with all camera system, 8 Turbo HD input, 8-ch video&1-ch audio input, 2 SATA interface, 1280×720P: 25(P)/30(N) fps/ch, 380 1U caseW/O HDD with all require software
Installation, Testing and Commissioning of 32" Full HD LED monitor with Power Cord complete as required & necessary video cards complete as required (if required). Make - Sony, Samsung, Philips
Supply, Installation, Testing and Commissioning Power Supply for Camera
Supplying & Laying 24U Wall mounted Rack for the CCTV DVR installation with all require power ports fixed wall rack has a tempered glass door and removable locking side panels. Included with this rack is one set of fully adjustable cage-nut style rails and removable top and bottom cable slot panels, allowing easy installation of CAT5 or fiber optic cables.
Supplying & Laying 24 port rack mounted switch for the following specfiication Approved by cUL Listed, CE, EN 60950, FCC Part 15 Class A, TUV, UL Listed 24 10/100/1000Mbps RJ45 ports
Supply, Installation, Testing & Commissioning of Bio metric Access Control with face detection and having a memory storage of 35 days for 200 members
Supplying & erecting recess speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size. (a)Round Shaped, 230mm dia. Speaker Make - JBL, Harman, Yamaha
Supplying & erecting wall mounting speaker with 5W rated input power 3.3 K. Ohms / 3W impedance, 100 - 10000 Hz frequency response with 6 inch dia. cone type 8 ohms speakers duly fitted in ABS plastic cabinet of colour match with wall or ceiling of following size. (a)Round Shaped, 230mm dia. Speaker - Make - JBL, Harman, Yamaha
Supplying & erecting of Amplifier having following specification: Power Output :250W (RMS) (300W Max.) inputs : 6 Misc. & 2 Aux. frequency Response :50-1500HZ I3db Tone Controls :Cut & Boost type LED Meter :5 LED Arrays The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections.Make - JBL, Harman, Yamaha
Supplying & erecting of Amplifier having following specification: Power Output :400W (RMS) (300W Max.) inputs : 6 Misc. & 2 Aux. frequency Response :50-1500HZ I3db Tone Controls :Cut & Boost type LED Meter :5 LED Arrays The amplifier suitable to operate 240V A.C.& 24volt D.C. (Battery) with automatic changeover from AC to Battery operation, duly protected by wrong Battery Polarity connections.Make - JBL, Harman, Yamaha
Supplying & erecting, Philips / Ahuja make Secretary unit comprising - 63 dBV, 7.5 mv/pa gooseneck microphone, Talk switch, Priority switch, Talk Switch LED, Ring LED indicator, connecting cable 6 core shielded, 2.5mtr long with female plug, 300 mw 8 ohms impedance speaker, connector for Delegate unit, volume control device fitted in heavy cast aluminium housing
Supplying & erecting, of 2cx1.5 Sq. mm Cu Flexible Speaker cable
Supply installation testing and commissioning High Speed quick power charging station for Trucks & Car for Electrical vehicle as per standard voltage rating with 40A FP MCB and 2 Nos 6A power plugs, it should have digital screen and all parameter recorders.
Supply installation testing and commissioning of roof top solar system with 20 years performance warranty , cost include high efficiency solar SPV module, require earthing, Lightening arrestor, supporting fabrication hot dip GI structure with paint, all require wiring, ACDB DCDB, Solar power meter, and inverter as require with consideration of 1-Year DLP
AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 1st Year after DLP (period 3% of Initial Cost) Cleaning of panels, Preventive maintenance, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with performance guarantee for the Installed Solar Panel for 2nd Year after DLP (period 3.5% of Initial Cost) Cleaning of panels, Preventive maintenance, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with performance guarantee for the Installed Solar Panel for 3rd Year after DLP (period 4% of Initial Cost) Cleaning of panels, Preventive maintenance, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with performance guarantee for the Installed Solar Panel for 4th Year after DLP (period 4.5% of Initial Cost) Cleaning of panels, Preventive maintenance, Checking of all wire connection, Inverter, Monthly Report to AMC etc
AMC : Comprehensive AMC with performance gurantee for the Installed Solar Panel for 5th Year after DLP (period 5% of Initial Cost) Cleaning of panels, Preventive maintenance, Checking of all wire connection, Inverter, Monthly Report to AMC etc
Supplying certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 1st Year Scope of work to Operate & maintenance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplying certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 2nd Year Scope of work to Operate & maintenance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Supplying certified, trained 2+Year Experienced / Electrician man-power for the Monthly Basis for 3rd Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Supplying certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 4th Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Supplying certified, trained 2+Year Experienced Electrician man-power for the Monthly Basis for 5th Year Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc.
Comprehensive AMC for the Full Electrical System for 1st Year after DLP (period 3% of Initial Cost) - Performance bank guarantee to be submit at time of completion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 2nd Year after DLP (period 3.5% of Initial Cost) - Performance bank guarantee to be submit at time of complwetion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 3rd Year after DLP (period 4% of Initial Cost) - Performance bank guarantee to be submit at time of completion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 4th Year after DLP (period 4.5% of Initial Cost) - Performance bank guarantee to be submit at time of completion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Comprehensive AMC for the Full Electrical System for 5th Year after DLP (period 5% of Initial Cost) - Performance bank guarantee to be submit at time of completion of work Scope of work to Operate & maintnance of the following Work HT VCB Panel, RMU, Transformer, Lt Panel, Cables, DB, MCB, MCCB, Capasitor, Light Fixtures, Fire Alarm Panel, Smoke-Heat Detector, HVAC System cable work, Light Pole, Facade Lighting, Data-TV-Telephone network and Equiment etc
Liaisoning with Local Electricity Board & Electrical Inspector for upgradation of Existing 11KV HT Power & Electrical inspector certification in totality to charge the power other related accessories. etc. complete. Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the authorities shall be prepared and furnished by the EPC Vendor. Any modification / rectification as required by these authorities shall be carried out by the EPC Vendor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
Liaisoning with local authority / Fire Dept for roof top solar system Charges for doing liasioning work for obtaining the necessary clearances from the Electrical inspector/competent Authorities for the total Electrical installation, Elevator Inspection, co-ordinating with various agencies. All necessary drawings, calculations, test certificates, etc. as required by the authorities shall be prepared and furnished by the EPC vendor. Any modification / rectification as required by these authorities shall be carried out by the EPC vendor at free of cost. The fees required to be paid to these authorities for inspection shall be borne by Owner on production of documentary evidences.
Supply, Installation , Testing and Commissioning of High Speed Microprocessor based with activation system comprising Hydraulic pump unit , Plunger pistons, balancing by compression spring ,internal stops adjustable for open or close beam positions . the barrier for continuous use for vehicular span of up to 6 meter, includes Boom with controller & accessories , 100% duty cycle. with complete as required
Supply, Installation , Testing and Commissioning of Twin Channel Exit Push put-on for open close with green and red Buttons.
Supply, Installation , Testing and Commissioning of Photocell based safety device to avoid closing of the barrier when a Vehicle is crossing the barrier.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Supply of Connectors, interfaces, Mounting hardware, Cords, Jacks, Plugs, tags, identifiers, fixtures, clamps, screws, nut - bolts etc as required for the installation and commissioning.
R and B Infra Project Private Limited
M/s D. H. Patel and Co
SHANTI PROCON LLP
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid