1)REPAIRS TO LIBRARY BUILDING IN KOLLAPURAM PANCHAYAT
Dismantling the existing damaged Plastering Surface Including cost and conveyance etc. complete.
Dismantling the excisting damaged Plastering Surface Including cost and conveyance etc. complete.
Earth work excavation for foundation in all soils and sub soils to full depth etc., ordinary soil complete
Supplying and filling in foundation and basement with filling sand including water consolidating etc.,
CC 1:4:8 using 40mm HBGs jelly for foundation concrete including cost and conveyance and all other labour charges etc., completed
Brick work in cement mortar 1:5 using country bricks of size 83/4"x41/4"x23/4" etc., complete
Plastering with CM 1:5 mix, 12mm thick including cost and conveynace and all laour charges etc., completed
Plastering with CM 1:3 mix, 10mm thick including cost and conveynace and all laour charges etc., completed
Paving the Floor with scratch proof Antiskid tiles of size 305x305x6mm including cost and all other labour charges etc., completed
Finishing the top of Sloped roof with ornamental tiles with cm in 1:3 12mm thick
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.
Painting two coat with ready mixed plastic emulsion of first quality paint and of approved colour over a priming coat including thorogh scarpping clean removal of dirt etc., complete as per standard specification.
Painting two Coat old Iron Works including through scarpping clean removal of dirt etc., complete as per standard specification.
Painting two Coat new Iron Works including through scarpping clean removal of dirt etc., complete as per standard specification.
Provision for NEW Window 1.20x1.30m charges
Provision for NEW Window 0.90x1.20m charges
Repairs to Main Door charges
Service connection wire
Wiring with 2x1.5(22/0.3) sqmm PVC unsheathed SC Copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with T.W. switch box with 5amps F.T. switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wireconnection of 14 SWG wire for cocealed Light point/fan point (5 points per coil) [ SD No. 21 ]
Wiring with 2x1.5(22/0.3) sqmm PVC unsheathed SC Copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with 150×100×113mmTW switch box for 5A - 3 pin- non inter locking CS plug Including pin top with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for concealed PVC Plug Point [SD NO 37 ]
Supply and fixing ofCFL Blub with guard ( Philips / Bajaj / Crompton / K Lite ) suitable for incandescent lamp with 60 W bulb.SD 80
Supply and fixing of 1200 mm ( 48") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 112
2)REPAIRS TO LIBRARY BUILDING IN KOTTUR (W/F) PANCHAYAT
Dismantling the existing damaged Plastering Surface Including cost and conveyance etc. complete.
Dismantling the excisting damaged Plastering Surface Including cost and conveyance etc. complete.
Earth work excavation for foundation in all soils and sub soils to full depth etc., ordinary soil complete
Supplying and filling in foundation and basement with filling sand including water consolidating etc.,
CC 1:4:8 using 40mm HBGs jelly for foundation concrete including cost and conveyance and all other labour charges etc., completed
Brick work in cement mortar 1:5 using country bricks of size 83/4"x41/4"x23/4" etc., complete
Plastering with CM 1:5 mix, 12mm thick including cost and conveynace and all laour charges etc., completed
Plastering with CM 1:3 mix, 10mm thick including cost and conveynace and all laour charges etc., completed
Paving the Floor with scratch proof Antiskid tiles of size 305x305x6mm including cost and all other labour charges etc., completed
Finishing the top of Sloped roof with ornamental tiles with cm in 1:3 12mm thick
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.
Painting two coat with ready mixed plastic emulsion of first quality paint and of approved colour over a priming coat including thorogh scarpping clean removal of dirt etc., complete as per standard specification.
Painting two Coat old Iron Works including through scarpping clean removal of dirt etc., complete as per standard specification.
Painting two Coat new Iron Works including through scarpping clean removal of dirt etc., complete as per standard specification.
Provision for Ornamental Tiles Painting Labour charges
Provision for NEW Window 1.20x1.30m charges
Provision for NEW Window 0.90x1.20m charges
Repairs to Main Door charges
Service connection wire
Wiring with 2x1.5(22/0.3) sqmm PVC unsheathed SC Copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with T.W. switch box with 5amps F.T. switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour with continuous earth wireconnection of 14 SWG wire for cocealed Light point/fan point (5 points per coil) [ SD No. 21 ]
Wiring with 2x1.5(22/0.3) sqmm PVC unsheathed SC Copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with 150×100×113mmTW switch box for 5A - 3 pin- non inter locking CS plug Including pin top with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for concealed PVC Plug Point [SD NO 37 ]
Supply and fixing ofCFL Blub with guard ( Philips / Bajaj / Crompton / K Lite ) suitable for incandescent lamp with 60 W bulb.SD 80
Supply and fixing of 1200 mm ( 48") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 112
3)REPAIRS TO LIBRARY BUILDING IN KURUNKULAM PANCHAYAT
Dismantling the existing damaged Weathering course Including cost and conveyance etc. complete.
Dismantling the excisting damaged flooring concrete Including cost and conveyance etc. complete.
Dismantling the excisting damaged Plastering Surface Including cost and conveyance etc. complete.
CC 1:4:8 using 40mm HBGs jelly for foundation concrete including cost and conveyance and all other labour charges etc., completed
Paving the floor with pre-polished concrete Anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 complete
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2
Providing weathering Course in roof tile including cost and conveynace and all laour charges etc., completed
Providing Pressed Tile with CM 1:2:4 of size 305x305x6mm including cost and all other labour charges etc., completed
Plastering with CM 1:3 mix, 10mm thick including cost and conveynace and all laour charges etc., completed
Plastering with CM 1:5 mix, 12mm thick including cost and conveynace and all laour charges etc., completed
White washing two coats using shell lime including cost of materils and all labour charges etc., completed
Distembering two coats with best approvde distembering including cost of materils and all labour charges etc., completed
Exterior emulsion two coats with best approvde distembering including cost of materils and all labour charges etc., completed
Painting two coats over old iron works using ready mixed enamel paint including cost of materils and all labour charges etc., completed
Repairs to door and window including cost of materils and all labour charges etc., completed Window
Door Repair Outer L Angle Shutter Replace
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 21
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 89
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for concealed PVC plug point SD 37
Supply and fixing of 1200 mm ( 48") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 112
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick -Service Wire
Providing IWC water Closet
Provision for water Supply charges etc.,
4)REPAIRS TO LIBRARY BUILDING IN UBAYAVEDHANTHAPURAM PANCHAYAT
Dismantling the execting wall plastering including cost and conveyance and all labour charges etc., completed
Earth work excavation and all class of soil execpt hard rock etc., completed as per std., specification etc.,
Supplying and filling with good river sand from approved quarry to work site including cost and conveynace ofall other labour charges etc., completed
Cement concrete 1:4:8 mix using 40mm HBG Metal including cost and conveyance of all materials and all labour chages etc., complete
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 sincluding cost and conveyance of all materials and all labour chages etc., complete
Granolithic Floor Finish with 1:2:4 mix using 25mm HBG Metal including cost and conveyance of all materials and all labour chages etc., complete
Brick work in CM 1:5 mix usihg country bricks of size 8¾x4¼x2¼ including cost and conveyance and all other labour charges etc., completed
Platering with CM 1:5 mix, 12mm thick including cost and conveynace and all laour charges etc., completed
Pointing with CM 1:3 using WCC including cost and conveynace of all material etc., completed
White washing two coats using shell lime including cost of materils and all labour charges etc., completed
Distembering two coats with best approvde distembering including cost of materils and all labour charges etc., completed
Exterior emulsion two coats with best approvde distembering including cost of materils and all labour charges etc., completed
Painting two coats over new iron works using ready mixed enamel paint including cost of materils and all labour charges etc., completed
Providing New window including cost of materils and all labour charges etc., completed
Providing New door including cost of materils and all labour charges etc., completed
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3 mm thick Hylum sheet cover with TW box And 5 A FT switch with continuous earth connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed Light point / fan point (For electronic Regulator) SD 21
Tube Light Fitting
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick Hylum sheet cover for 5 A 3 pin non interlocking CS plug with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for concealed PVC plug point SD 37
Supply and fixing ofCFL Blub with guard ( Philips / Bajaj / Crompton /K Lite) suitable for incandescent lamp with 60 W bulb.SD 80
Supply and fixing of 1200 mm ( 48") AC ceiling fan complete with stepped electronic 300 W regulator with 300 mm down rod on the existing clamp. SD 112
Wiring with 2 X 1.5 Sq.mm (22 / 0.3) PVC insulated SC unsheathed Copper conducutor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 mm X 100 mm X 113 mm TW switch box with 3 mm thick -Service Wire
Repair to Window Charges
RAINWATER HARVESTING STRUCTURE
Earthwork Excavation in Hard Soil - Earthwork excavating and depositing with in initial lead of 10mand lift of 2m (For roads, supply channels, desilting of MI Tanks, Pond & Kulam) - upto 0.30m depth
Filling the soak pit with 40mm metal as per specification
Filling the soak pit with 20mm metal as per specification
Collection and supply of Sand and filling into the basement including cost and conveyance to the site and all labour charges for filling as per standard specification.,
Supplying and fixing P.V.C rainwater down fall pipe of 110m dia with necessary shoes, bends,& clamps etc.
Cement mortar 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying, and curing etc complete for 10 cum
Brick work in cement mortar 1:5 mix using country bricks 83/4"x41/4"x23/4" and conveyance of all materials to site and all labour charges etc complete
Plastering with cement mortar 1:5 mix to 12mm thick including cost and conveyance of all materials to site and all labour charges etc
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
CHANDRASEKARAN VIJAYALAKSHMI (BID ID -1408298)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .