Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 May 2023, 6:00 pmClosed
Garrison Engineer Brichgunj
GE Brichgunj Port Blair
REPAIR and MAINT OF CENTRAL AC PLANT OF LIKABALI AUDITORIUM and UNDER GE BRICHGUNJ PORT BLAIR
2023_MES_593398_1
8346A
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Brichgunj
As Per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Brichgunj
₹30,000
Yes
15 Jun 2023
4 May 2023
31 May 2023
4 May 2023
25 May 2023
19 May 2023
Amount
M&L for descaling the shell and tube condenser of 50TR (4x12.5TR) capacity chiller of AC plant by circulating the descaling chemical (scale gun/ HCL acid) through condenser tube by pressure feeding method after disconnecting condenser water lines and opening the end covers of both side, brushing condenser water tubing, removing the scales, normalising the copper surface by circulating chemical agent, refixing/ assembling all dismantled parts, replaceing gasket set, etc., testing, running the system to the required cooling effect and painting the condenser with two coats of synthetic enamel painting,complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed.
Disconnecting /removing of defective compressor unit from the chiller unit after carefully disconnect the electric wires and gas pipe line and repalcement with new screw/ scroll type compressor, hermetically sealed suitable for 12.5TR capacity : Make : Danfoss, Model No. SZ185S4RC
M&L for cleaning/ servicing the AHU of AC plant, 13000CFM capacity by pressure air method using air blower and cleaning 6 rows of chilled water cooling coil section 12 FPI with cleaning solution, descaling by chemical agent, cleaning the AHU filter by using high pressure air, greasing to AHU blower shaft/ motor bearing for smooth functioning, cleaning the AHU base tray, etc., complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed.
Material & Labour, spray painting of Central AC plant with 2 No, suction, discharge and liquid line, chiller, water lines in cooling tower basin by removing peeled off old paint with scrapper including writing SM No./Ser No. and painting with two coats of synthetic enamel paint of 1st quality as per standard shade and colour, complete all as specified and directed.
M&L for pressure leakage testing of complete system of Central AC plant using dry Nitrogen gas by isolating the cooling coil from both ends of high side and low side, pumping down the refrigerant gas, keeping in safe condition for refill, charging the dry nitrogen gas for pressure leak test, after detecting leak point release the nitrogen gas, rectifying the leak point by means of soldering/ brazing and connecting the cooling coil with system, vaccumised the complete system and re-charge the system by refrigerant, top up of additional quantity of refrigerant gas if required, etc., including testing and commissioning to the required cooling effect complete to the entire satisfaction of the Engineer-in-Charge all as specified and as directed by Engineer-in-Charge. Notes :- (a) Cost of Nitrogen gas required shall deemed to be included in the quoted rate. (b) Refrigerant gas required shall be measured and paid separately under respective item of this Schedule.
M&L for repair/ servicing Centrifugal pump set10HP capacity, three phase, 50 C/S by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the motor, cleaning, greasing to bearing/ bushes, replacing worn out bearings, nuts & bolts, dismantling/ taking down burnt out winding, rewinding the motor with same guage, weight and same number of turns of super-enamelled Copper wire and varnishing compound including heating and re-assembling the motor, brought back to site, refixing at its original position/ location with proper alignment including painting the pump with two coats of synthetic enamel painting, connecting, testing and commissioning after repair, etc., complete to the entire satisfaction of the Engineer-in-Chargeall as specified and as directed by Engineer-in-Charge. Notes : (i) Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule.
M&L for servicing of Centrifugal pump set 10HP capacity by disconnecting/ dismantling (electrically & mechanically) and transporting to workshop, opening the pump motor, cleaning the pump, removing scales, greasing to bearing/ bushes, replacing the worn out bushes, bearings, gland rope, gland nut & bolts, painting the pump with two coats of synthetic enamel painting, re-assembling the pump, brought back to site, fixing it at its original location with proper alignment including connecting, testing and commissioning, etc., complete all as specified and as directed by Engineer-in-Charge. Note : Bearing shall be measured and paid for separately as "supply only" under respective items of this schedule.
Supply only bearing suitable for 10HP three phase motor of Centrifugal pumpset.
Supply and top up Regrigerant gas R-407 C in manufacturer's sealed cylinder.
Supply and top up compressor oil in 10 ltrs pack suitable for compressor of Model SZ 185.
S&F in repair/ replacement of LP/ HP combination cut out/ cut off switch, type MP-15 suitable for working on R-407C gas complete with flare nut. [Make : Danfoss]
S&F in repair/ replacement of oil pressure control/ cut off switch, type MP-55 suitable for R-407C complete with flare nut all as specified. [Make : Danfoss]
S&F in repair/ replacement of water pressure cut out 1 PS-70 all as specified.
S&F in repair/ replacement of pressure gauge of LP/ OP (low pressure/ oil pressure) size 4"dia of rating 30 to 150 PSI suitable for working on R-407C gas complete with flare nut all as specified.
S&F in repair/ replacement of high pressure [HP] gauge of dial size 4" dia of rating 0-300kg/sqcm PSI suitable for working on R-407C gas complete with flare nut all as specified.
S&F in repair/ replacement of water pressure gauge of dial size 4" dia of range 0-7 kg/sqcm or 0-100 PSI rating all as specified.
S&F in repair/ replacement of thermostatic expansion valve of suitable flare size including brazing, welding work, etc., for 50Ton chiller plant all as specified.
S&F in repair/ replacement of Thermostat unit in Central AC plant 50TR capacity suitable on working 10˚C to 30˚Cas per OEM.
S&F in repair/ replacement of Humidistat unit in Central AC plant 50TR capacity suitable for 0 to 100% as per OEM.
S&F in repair/ replacement of Outlet Water Temperature sensor suitable for chiller of AC plant. [Model No.XWC4S-052 A RII]
S&F in repair/ replacement of 3 pole Power Contactor type MNX 18 with coil voltage 230Volts, AC suitable for compressor motor in AHU of Central AC plant all as specified and as directed.
S&F in repair/ replacement of overload relay, direct mounting type suitable for relay range of Amps 14 to 23 Amps. [Make : L&T or equivalent]
S&F in repair/ replacement of electronic type star delta starter fully automatic suitable for 10HP pump motor in sheet metal enclosure with single phase protection feature with motor rating AC - 3 duty, 415Volts, 50Hz, 3 phase all as specified and as directed.
S&F in repair/ replacement of Push Button suitable for Star Delta Starter
S&F in repair/ replacement of Neon Indicating Lamps 230Volts AC supply
M&L for checking of leakage in the chilled water pipeline at all joints and valves and arrest the leakage by replacing the gasket and tightening of nuts & bolts complete all as specified and as directed.
M&L in repair/ replacement MS tubing with all MS fittings such as bends, tees, reducers, etc., in any length, necessary leak proof welding work, etc., pressure testing, washing out of the pipeline including taking up or down unserviceable corroded MS water/ air mains with all fittings, complete all as specified and as directed. (a) 100mm bore
(b) 50mm bore
S&F in replacement, gun metal, globe or gate valves, ISI marked, suitable for 50mm bore with iron wheel head, screwed both ends and fixed including taking down old unserviceable gun metal, globe or gate valve complete all as specified and as directed.
S&F thermal insulation for air ducting using 25mm thick fibre glass wool of density 24kg/cum including dismantling existing old unserviceable air duct complete all as specified and as directed.
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with Copper stranded conductor 1100 volt grade of cross section area3 Core 6 sq mm
Supply, lay, test and commissioning under ground XLPE insulated and PVC sheathed, armoured heavy duty under ground cable, suitable for earthed system, laying in trenches/duct sleeving through pipe in duct, ISI marked with Copper stranded conductor 1100 volt grade of cross section area3 Core 16 sq mm
Suplly and fix MCCB four pole 400A 36 kA complete all as specified and as directed.
Suplly and fix MCCB three pole 160 A 25 kA complete all as specified and as directed.
S&F in replacement, Cast Iron Butterfly valve suitable for 100mm bore pipe confirming to IS 13095 with provision of suitable GI flanges, nuts, bolts, double washers, rubber gaskets including taking out old unserviceable valve, etc., complete all as specified and as directed.
S&F in repair/ replacement of Blower Motor 10 HP for AHU 13000 CFM capacity AC plant including taking down old unserviceable blower motor all as specified and as directed.
S&F in repair/ replacement of fan motor 3 HP for Cooling Tower 50TR capacity including taking down old unserviceable fan motor all as specified and as directed.
Suplly and fix MCB three pole 63 A complete all as specified and as directed.
Disconnecting and removing unseriveable Star-Coupling assembly set from the pump-motor drive system, supply and fixing new Star-Coupling set, sizes of 100/110 with nuts, bolts including making lathe machine work ,alignment and testing complete all as specified and directed.
Disconnecting and removing unseriveable Rubber Star-Coupling from the pump-motor drive system, supply and fixing rubber Star-Coupling sizes of 100/110 with nuts, bolts including making alignment and testing complete all as specified and directed
Supply only various sizes of Pillow block bearing . Make : SKF/NBF
S&F cooling fan vanes for morots of various capacity.
Supply and fix mechanical sealing for pump of capacity upto 10 HP
Taking down shaft from various type /capacity of pump set/ motor/ monoblock, welding, re-melting & turning of shaft in lathe machine and testing of machines all as specified and directed.
Disconnecting and removing unserviceable Chilled Water Sensors from the chiller and S&F new Chilled Water Sensor including connecting and testing complete all as directed. Make : Voltas/Bluestar/York/Trane/Dananbush
Removing unserviceable existing fills from cooling tower and Supply and fix new fills upto 10mm thickness including maintainance of basement of fills of any capacity cooling tower complete all as specified and directed.
Supply and fix as in replacement of Sprinkler assembly/Nozzle assembly with PVC pipes including dummies for 60 TR capacity cooling towers all as specified and directed.
M&L for repairs to cooling tower bottom by fibre reinforcing complete all as specified and directed.
M&L for repairs to cooling Tower Body by fibre reinforcing complete all as specified and directed.
Dismantling and taking out unserviceble canvas cloth box from AHU unit and S&F ew canvas cloth box including MS frames refixing with new nuts, bolts, washers,gasket etc and testing complete all as directed.
S&F cooling tower fan blades(Cast Metal) including HUB set as per sample.
Taking down micro processor based control panel of chiller package AC plant make Blue star /Voltas/ Carrier / Dhanham Bush of various capacities, removing the unserviceble PCB, supply and fix new PCB to micro processor based control panel and refixing to chiller package and programing of the entire panel for smooth functioning, testing complete all as specified and directed. Note : The work shall be executed through OEM of make Blue Star /Voltas/ Carrier /Dhanham Bush
Taking out unserviceable Pre-filter, Supply and fixing new Pre filter to 20 micron level of approximate size 60 X 60 X 6 Centimeters complete all as directed.
All as per item No 74 above but approximate size of 60 x 30 x 6 CM
All as per item No 74 above but approximate size of 30 x 30 x 6 CM.
Disconnecting and removing the unserviceable burntout Timer, S&F new Star Delta timer 0 to 10 Sec all as directed. Make:- GE /SIEMENS/L&T
Supply only Single Phasing Preventor with auto start ON Delay Timer (Auto Reset, 50Volts Unbalance, 1NO Contact) provision for connection of Auto/Manual switch externally 415V complete all as specified. Make: Minilec/Powertek/GIC/IndoAsian.
Supply only 'V" belts of size A-78 complete all as specified.
Supply only 'V" belts of size B-70 complete all as specified.
Supply and Fix ADD ON Blocks 1NO+1NC complete all as specied and as directed .
M/s Karbhagam Sales Agency
A. R. ELECTRICALS
RK TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .