Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC Accepted , Being L1 | |
| 2 | L2₹43.5 L+₹58,268 (1.36%)Rejected-AOC 01 AALAM E NOOR UI MASJID OLD PAHAR GAON DOLLYGUNJ POLYTECHNIC ROAD SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹44.5 L+₹1.5 L (3.55%)Rejected-AOC 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹45.1 L+₹2.1 L (4.94%)Rejected-AOC | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹45.9 L+₹2.9 L (6.86%)Rejected-AOC | L5 | Rejected-AOC Not Being L1 |
Tender Value
₹43.4 L
EMD Value
₹86,860
Closing Date
11 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo, Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION ALTERATION TO COMCG OFFICE AND CERTAIN ALLIED WORKS AT CGRHQ A AND N UNDER GE HADDO PORT BLAIR
2024_MES_650740_1
8837/E8
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and Category b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹86,860
Yes
26 Jul 2024
23 Apr 2024
18 May 2024
23 Apr 2024
11 May 2024
6 May 2024
24 Apr 2024 - 29 Apr 2024
Amount
Dismantling floor, hearth or wall tiling including CM bedding, removing rubbish off the premises complete all as specified and as directed.
M&L Vitified Ceramic tiles 10 mm thick (square/ rectangular) polished, double charged with border design if reqd, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including cement screed bed 15mm thick in cement mortar 1:6, etc complete all as specified.
M&L for 25mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in sub base to flooring etc all as specified and as dierected.
Dismantling of False ceiling boarding including grid of any description fixed in any position with nails or screw etc all as specified and directed.
M & L seamless false ceiling made out of 12mm thick of gypsum board fixed to the ceiling section with 25mm long self drilling and tapping screws having Philips head with under head cutter at 200mm centre to centre, including finishing the joints of face board with specially formulated joining compound and 48 mm wide fibre tape to provide seam less finish and including GI channel 0.55 mm thick with two unequal flanges of 20 to 30mm and web of 27 mm fixed to surrounding wall using nylon sleeve and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 215 mm each and web of 45 mm suspended from soffits at approx. 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.20mtr length) of 0.55 mm thick having kurled web of 50 mm and flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including 6mm thick GI hangers adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40x3 mm size long and expansion hold fasteners 12.5mm dia 40mm long including thin layer of Pop with Gypsum binder, sanding the surfaces till smooth surface is obtained and finally applying two coats of acrylic emulsion over one coat primer over 3mm thick putty all as specified and as directed
Supply only plain sheet glass 5.5 mm thick ordinary quality and glazing with aluminum glazing clip in aluminum window shutter not exc 0.5 Sqm in each pane etc all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories) etc complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall or in floors etc using synthetic rubber adhesive cement solvent complete all as specified.
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified.
M&L precast cement concrete block masonry exc. 10 cm width with solid block C1 (1:3:6) (using 20 mm graded stone aggregate) and setting in cement mortar (1:6) all as specified and as directed.
M&L for 10mm thick plaster in CM (1:6) on fair faces of concrete/PCC block surfaces of walls finished even and smooth (without using extra cement) etc complete all as specified and as directed
M&L for rendering 15 mm thick cement plaster in CM 1:4 with WPC on fair faces of brick work or concrete surfaces at any height with neccesary scafoldings, finished even smooth without using extra cement etc complete all as specified and as directed.
M&L for Preparation of newly plastered internal wall surface and applying two coats of distemper oil emulsion over a coat of primer over the coat of 3mm thick wall care putty etc complete all as specified and as directed
M&L for preparation on newly plastered external wall surface and applying two coat of weather proof (exterior grade) acrylic emulsion paint with anti fungal property over a coat of primer of the same manufacturer as that of paint complete all as specified and as directed. (Make: Dulux Weather Shield Max or Apex Ultima from Asian Paints or Berger weather coat All guard or equivalent).
M&L aluminium composite panel sheet of 3.0mm thick with skin thickness of 0.25mm of aluminium on both sides, sandwiched by 2.5mm polyethylene core with PVDF coating of 30.0micron fixed over frame of aluminium tubular section 50x25mmx 2.0mm thick, having panels not exc 1200x1200mm with necessary silicon filling, in approved pattern as in column, beam, wall etc at any height with necessary scaffoldings as per the site requirement.
M&L for complete removal of existing treatment on internal wall surfaces and applying two coat of distemper oil emulsion over a coat of alkali resistant priming paint over a coat of 3mm thick wall care putty etc complete all as specified and as directed
M&L for 18mm thick rubco huat rubwood in built up interiors as in cupboards, shelves wall lining, box structure and including all fitting items complete all as specified and directed. After completing the carpentry works all the visible wooods area will be sanding by No. 60 & 80 wood sanding paper, after that will be applying sheenlac make Filler with mixing of NCD thinner (Sheenlac make) then pasing chock putty in the shabby/nailing area which will be sanding with No. 120 Sanding Paper, after that will applying sealer of sheenlac make and walnut colour stainer, then cutting with No. 320 Sand Paper, after completing the above process will spray Melamine Polish of Berger/Sheenlac make then cutting with No. 400 Sandng Paper, Finally will applying Silicon make Waxpol with soft Banyan Cloth for better shinning /finishing. Make of rubber wood members : RUBCO or equivalent
S&F Fabric Venetian blinds, roller type (Suitable for windows) complete set with slat thckness 50mm with cord tilter for adjustments fixed with necessary brackets etc all as specified and as directed. Note: 1. Colour of Fabric will be Finilized by Engr-in-Charge. 2. Size of Window opening will be measured for payment purpose.
Supply, laying, testing and commissioning of LT XLPE insulated, sheathed, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of size 3.5 core x 150 sq.mm. (laid in trenches, ducts, pole, wall etc.) complete all as specified and as as directed by engineer in charge. Note: (i) Necessary test results like continuity test, megger tests, shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation earth work will be measured and paid separately.
Excavation in tranches n.exc 1.5 mtrs wide and not exv 1.5 M deep in soft/loose soil and getting out all as specified and directed.
Returning, filling in incl spreading, levelling and well ramming in layers not exc 25 cm in soft / loose soil all as specified and directed.
Removing excavated soil to a distance not exc 50M and depositing where directed at level not exc 1.5 m above starting point all as specified and directed.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead strip of size 32X6 mm by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through 40 mm dia GI pipe for protection of GI pipe including 20mm dia GI pipe for watering GI funnel , PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing all as directed by Engr-In-Charge.
M&L earth continuity conductor or main earthing lead of size 32x6mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to ples or any other indicated situation for loop earthing etc complete all as specified and as directed
Supply and laying HDPE DWC pipe of size 120 mm(OD) x 103mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/ HT cable protection complete all as specified and as directed by engineer in charge.
S & F DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming MCCB 100amp Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete including taking down old unserv DB of any type /rating and making good to the distrubed surface /walls all as specified and directed. Make : Indo Asian/Havells/L&T/Legrad. complete all as specified and as directed.
Supply and Fixing in repair for 4 pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
Supply and fixing of SS Enclosure size II for 3P/4P MCCB's on wall with In-built neutral Link for TPN system for suitable for 250A MCCBs, 50kA with adequate space for cable termination all as specified and directed.
Supply and fix 3 Pole MCCB 350 Amp, 50 Hz, 415 V with rupturing capacity 50 KA all as specified and directed.
Supply, install, test & commissioning of Split type air conditioner, 4.0 TR capacity, vertical tower type having cord less remote control unit,non inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, three phase, 433 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum (3+8*) RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, complete all as specified and as directed. MAKE : Blue star VC148GBTUR3 or eqvt in Hitachi/Daikin NOTE:1. Extra all connected pipes Upto 8* RM shall be included in quoted rate. 2. The drain out water pipe connection should be connected up to ground level
Supply, install, test & commissioning of Split type air conditioner, 2.0 TR capacity, BEE 5-Star rating, having cord less remote control unit, wall mounted inverter type with built-in ioniser and plasma filter for better air quality, copper wound, electric driven, single phase, 240 volts, 50 Hz, AC supply including transporting to site, fixing of indoor and outdoor units with necessary wall mounting brackets, necessary copper piping minimum (3+5*) RM for connections, cutting, bending, brazing, proper insulation on copper pipe and all other pipes, PVC drain pipe upto ground level, installation complete with all accessories including connecting electrically between indoor and outdoor units with suitable size of PVC insulated multistranded copper conductor, complete all as specified and as directed. MAKE : Blue star IC 524 DNU or equivalention Hitachi/Daikin NOTE:1. Extra all connected pipes Upto 5* RM shall be included in quoted rate. 2. The drain out water pipe connection should be connected up to ground level
S & F of Starter switch of capacity 25 amps, working on 240 volts AC supply, suitable for air conditioner. Make : (Crabtree: Cat Part No.ACTO252504/ or equivalent in Anchor/ Standard
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials and making good disturbed surfaces of walls, floors, etc.
Taking down fuse Unit/DBs 415 Volt/230 Volt.
Taking down old aluminium sub main wiring of any size.
M & L point wiring complete with 1100 volts grade, 1.5 sq.mm (nominal area), single core, FRLS PVC insulated ,unsheathed, multi stranded copper conductor cable drawn through and including medium grade, rigid , non-metallic PVC concealed/ on surface conduit of size not less than 20 mm dia, with all necessary fittings, concealed in walls/ floor or surface on wall/ roof duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth duly including suitable size of factory made fabricated MS sheet modular terminal box, flush mounting in the wall for mounting switches/switch socket combinations/ fan regulators etc., covered with suitable size of modular cover plates complete in making good the existing surface with existing colour coding as required at site complete all as specified for the following :-
All as per item Sl No 38 above but for One light/fan point controlled by one modular switch 5 Amps one way complete all as specified and directed.
All as per Srl item No 38 above but two light points controlled by one switch 5 Amps one way.
All as per item Sl No 38 above but for one modular 3 pin 5 Amp socket out let on independent board complete all as specified and directed.
All as per item Sl No 38 above but for one modular 3 pin 5 Amps switch socket on same Board complete all as specified and directed.
All as per item Srl No.38 above but point wiring with 4.0 sqmm PVC FRLS insulated multistranded copper conductor suitable for one 3 pin 15 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed.
S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed.
S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed.
S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal complete all as specified and directed.
S & F stepped type electronic fan regulator modular type complete all as specified.
S & F motor starter switch of capacity 25 Amps working on 240 volts AC supply alongwith with 25 Amps mini MCB SP type 'C' 240 volts for air conditioner complete all as specified and directed.
Taking down carefully ceiling fan of any make, size from its location, handed over to AGE E/M store yard without any damage
S & F BLDC 5 star rated ceiling fan metallic body ISI marked 1200 mm sweep, 220V AC, 50 Hz with all accessories alogwith providing and connecting up with 1.0 sqmm 3 core flexible copper conductor of suitable length from fan connector to ceiling rose and testing complete all as specified and as directed by Engr In charge. Make: CG Model No : ENERGION Groove 28 watt or equvalent to Havells/ Usha
Supply & fixing Wall mounting fan 400 mm sweep incl all fixing arrangement complete all as specified and directed Make: Havells Model No : 400 mm FHWMWHSWHB16 (Marvel Wind HS White Blue) or equivalent to CG/ Usha/ Orient
Supply and fixing of Decorative ultra slim linear LED lighting fixture of 18 Watt recess mounted 220V , 50Hz with Aluminium housing ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make - Philips Cat Part No : Dura Slim or equivalent make in CG/Havels /Luker. NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting.
Description same as per item sl No 49.00 above but, 15 watt.
S & F Surface mounted general purpose square shaped luminaire with low height CRCA housing (white & grey housing with profiled & flat diffuser as per reqd) and high transmissivity diffuser of cap 36 watt including all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified and directed. Make :- Philips model No- SM366C LED32-6500 PSU OD GR or equivalent to Havells/ CG/ Luker
S & F Sub main wiring with PVC insulated FRLS cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and incl rigid PVC concealed/surface conduit (ISI marked) 25 mm dia incl all specials/ accessories (or) 32 mm wide rigid non-metallic PVC casing and capping and its accessories etc and provision of PVC insulated FRLS copper conductor single core 4.0 sq mm for earth continuity all as directed.
All as per item Sl No 52.00 above but sub main wiring with 2 single core 6 sq mm duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire. Note for item No 52.00 & 53.00 : 3 length of cable and one length PVC casing and capping shall be measured and paid for one length.
S & F SPN DB sheet metal enclosure double door suitable (IP-43) Protection 12 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete.
All as per item Sl No 54.00 above but 8 way.
S & F MCB SPN 40 Amps (`C’ series) having current rating 10 KA complete all as specified and directed.
S & F MCB SP 06-32 Amps (`C’ series) having current rating 10 KA complete all as specified and directed . Note for item No 55.00 & 56.00 :- All copper conductors should be connected with MCB alongwith copper reducer terminals of suitable size duly crimpled.”
M & L Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement all as specified and as directed by Engineer-in- Charge.
Supply and fixing with wall, piller, wooden structure etc. uPVC Panel Trunking of size 75 mm (H) x 75 mm (W) for running of wire, cable of any type etc complete all as specified and directed by Engr In charge. Make :- Precision or equivalent to Supreme .
All as per item No. 59.00 above but size 100 mm (H) x 75 mm (W).
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
LOOK UP ENTERPRISES
Ravi Enterprises
M/s Prem Enterprise
bansal construction
Kakolil Trade Agencies
M/s Karbhagam Sales Agency
Manas Patra Steel Fabrication
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .