Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹29.3 L+₹5.5 L (23.1%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹43.0 L
EMD Value
₹86,000
Closing Date
29 Aug 2023, 6:00 pmClosed
Cdr, HQ 138 WE
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
SPL REPAIR REPLACEMENT OF UNDERGROUND CHS PIPELINE AND CONNECTED ASSESSORIES FROM PLANT NO 02 TO OFFRS MESS OFFRS LIVING ACCOMODATION AT LADAKH SCOUTS REGIMENTAL CENTRE AND PROVN OF STANDALONE CHS IN OR DINNING HALL BLDG NO TO 431 IN 129 SATA
2023_MES_610804_1
138WE/L-48/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹86,000
Yes
24 Jan 2024
27 Jul 2023
5 Sept 2023
27 Jul 2023
29 Aug 2023
10 Aug 2023
Amount
Supply , laying, fixing and testing of Pre insulated MS Pipe of size 150mm dia bore, class 'C' having thickness of PUF insulation 36mm of density 36 Kg/ Cum and 26 gauge GI cladding complete suitable for above ground complete incliding taking down old existing pipe, complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 1 above but for Pre- insulated MS Pipe of size 100mm dia bore, complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 1 above but for Pre- insulated MS Pipe of size 80mm dia bore, complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 1 above but for Pre- insulated MS Pipe of size 65mm dia bore, complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 1 above but for Pre- insulated MS Pipe of size 50mm dia bore, complete all as specified and directed by Engr-in-Charge.
S&F PPR Pipes 40mm dia PN 16/SDR 7,4,3 layer UV stabilized and anti microbial fusion welded having thermal stability for hot and cold water supply including all PPR plain and brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc including taking down old existing pipe, complete all as specified and directed by Engr-in-Charge.
All as per item Ser No. 6 above but 32mm dia bore, complete all as specified and directed by Engr-in-Charge.
S&F PPR Gate valve (Brass insert) conforming to ISO 9001-2000 conforming ISO-15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PPR pipes or for union and fixed including taking down old existing valve for the size of 40mm, complete all as specified and directed by Engr-in-Charge.
S&F PPR Gate valve (Brass insert) conforming to ISO 9001-2000 conforming ISO-15801 screwed down high pressure with crutch or butterfly handle screwed both ends for PPR pipes or for union and fixed including taking down old existing valve for the size of 32mm, complete all as specified and directed by Engr-in-Charge.
S&F tracer cable for binding water pipe lines raising main and distribution lines including electric connection etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Non return butterfly valves of 100mm bore as per existing, including taking down, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Non return butterfly valves of 80mm bore as per existing, including taking down, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Non return butterfly valves of 65mm bore as per existing, including taking down, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Non return butterfly valves of 50mm bore as per existing, including taking down, complete all as specified and directed by Engr-in-Charge.
S&F in replacement bronze Globe valve including taking down flanged 100mm dia, complete all as specified and directed by Engr-in-Charge.
S&F in replacement bronze Globe valve including taking down flanged 80mm dia, complete all as specified and directed by Engr-in-Charge.
S&F in replacement bronze Gbobe calve flanged 50mm dia including raking down, complete all as specified and directed by Engr-in-Charge.
M&L for excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc, or for laying UG cavble in trenches on plan and n exc 1.5m in depth in hard dense soil and getting out, complete all as specified and directed by Engr-in-Charge.
M&L for Returning, fillings in (hard dense soil), including spreading, leveling, watering and well ramming in layers not exc 25m, complete all as specified and directed by Engr-in-Charge.
M&L for Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the strating point, complete all as specified and directed by Engr-in-Charge.
Supply and installation testing and commissioning of ductable type standalone oil fired kerosence/ HSD based heating system (Top Mounting) Complete with stainless steel heat exchanger chamber consisting of furnance fabricated out of high temmperature resistence stainless steel, automatic burner assembly control panel with sequence controller. photocell, for flame failure. HT Transformer electrode fan assembly with motor temperature controller stainless steel reflector, built in fuel oil piping exhaust chimney all housed in powder coated cashing suitable for operator on 50 Hz single phase 230 volt AC Supply capacity 75000L K/CAL/Hr including ducting for Hot air blowe to room with following:- (a) Heat Output - 75000 K/Cal/Hr. (b) Hot Air Temp - 40C (c) Temperature Rise - 90 C Max (d) Fuel Consumption - 2.5-2.9 Lt/Hr (e) Thermal Efficiency - 80-90% (f) Electrical Supply - 220 Volts 50 Hz (g) Temperature Control - Automatic (h) Fuel - Kerosene/ Diesel (j) Bruner - Riello/ Ben-tone
Supply and fix Ducting for Hot air blower to room of size 26x1x1 feet with complete insulation 6mm thick as per site reqmt, complete all as specified and directed by Engr-in-Charge.
M&L for point wiring for power point 3 pin switch socket 15 Amp with PVC copper counductor cable multistrand unsheathed 2.5 Sqmm on independent board incl one run 1.5 Sqmm multistrand PVC copper conductor cable for earth continuity in and including PVC casing and capping fixed on wall, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of sheet metal enclosure for DBs douoble door when MCBs to be used single pole & neutral 240 Volt 4 ways, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB SPN 40 to 63 Amp 240 Volts AC ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB SPN 5 to 32 Amp 240 Volts AC ISI marked, complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electode 600mm x 600mmx 6mm thick buried directly in ground. (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanized earth lead wire 4mm dia by GI Watering pipe with funnel and wire mesh amd 15mm dia pretection pipe earth work etc complete all as shown in electrical plate No 5 of MES plate No 6, complete all as specified and directed by Engr-in-Charge.
M&L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/ recessed as required in PVC casing caping wire size 2x6.0 Sqmm + 1x4.0 Sqmm earth wire, complete all as specified and directed by Engr-in-Charge.
EESSI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .