Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Published by the portal on this tender, for queries and grievance redressal.
split air conditioner 1.8 - 2.0 ton
split air conditioner 1.5 ton
split air conditioner 1 ton
Automatic Voltage Stabilizer
copper tube
pvc conduict pipe
uninstallation
10206492
GEM/2026/B/8308992
Two Packet Bid
split air conditioner 1.8 - 2.0 ton
Hyderabad, Telangana
Total value wise evaluation
BOQ
8 documents required · 8 mandatory
3 yrs
₹3.9 L
₹21 L
80%
Office presence required
Main bid checked; linked documents have not been assessed. Review the source conditions for office type, district, timing and other eligibility requirements.
Buyer office clause · Page 11
AVAILABILITY OF OFFICE OF SERVICE PROVIDER: An office of the Service Provider must be located in the state of Consignee. DOCUMENTARY EVIDENCE TO BE SUBMITTED.
View source document · Page 11Exempted
Yes
25 Nov 2026
25 Nov 2026
17 Dec 2026
90 days from bid end date (until 16 Mar 2027)
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) | Spec |
|---|---|---|---|---|---|---|---|
| 1 | split air conditioner 1.8 - 2.0 ton | Supply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.8/2.0 TR with a minimum cooling capacity of 6,100 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work. | 2 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 2 | split air conditioner 1.5 ton | Supply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.5 TR with a minimum cooling capacity of 5,100 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work. | 9 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 3 | split air conditioner 1 ton | Supply, installation, testing, and commissioning (SITC) of single phase, 5 star, Inverter hi-wall split type air conditioner unit, capable of performing cooling with nominal capacity 1.0 TR with a minimum cooling capacity of 3,200 Watts and above. Unit shall be supplied with manufacturer offered copper pipe (3 meters), power & communication cable, drain pipe and mounting stands for both indoor and outdoor unit along with all necessary accessories for installation of air conditioning unit. This work also includes core cutting for accommodating refrigerant pipe, cables and drain pipe. Refer Annexure-I for detailed specifications and scope of work. | 1 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 4 | Automatic Voltage Stabilizer | Supply, installation, testing and commissioning of 5 KVA stabilizer including standard test reports Please refer annexure-I for detailed specifications and scope of work. | 2 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 5 | Automatic Voltage Stabilizer | Supply installation testing and commissioning of 4 KVA stabilizer including standard test reports
Please refer annexure-I for detailed specifications and scope of work. | 10 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 6 | copper tube | Supply and commissioning of Two 02 runs of Copper pipe suitable for connecting indoor and outdoor units of high wall split air conditioner units with 09 mm nitrile rubber closed cell insulation of following sizes
Refer annexure - I for detailed specifications | 35 | rmt | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 7 | pvc conduict pipe | Supply of ISI 20 mm outer dia rigid PVC pipe for connecting drain pipe of Hi-wall split ac indoor unit. | 35 | rmt | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 | |
| 8 | uninstallation | Removing of existing split air-conditioner units. | 14 | nos | Rajnish Kumar 500007,CSIR-IICT UPPALROAD TARNAKA | 15 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_10206492.pdf
GEM_BID • 0.17 MB
detailed_technical_specifications_2026-11-23-16-53-49_cdc54489019214e02b6ddf1bf7d117dc.pdf
BOQ • 0.64 MB
boq_item_sample_file_2026-11-23-16-53-49_1f65b51bb40e1cb889e8a3fdb20c8e81.csv
BOQ • 0.00 MB
DTC_3ae63964-23ec-408a-a0b11795606840906_panidhar.k@csir.res.in.pdf
GEM_OTHER • 0.64 MB
gtc.pdf
GEM_OTHER • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .