| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.4 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹27.1 L+₹68,984.52 (2.61%)Rejected-Finance | L-2 | Rejected-Finance BEING L-2 | |
| 3 | L-3₹27.3 L+₹83,032 (3.14%)Rejected-Finance 1 AL SHEIKH COMPLEX 1ST FLOOR PEERBAGH CHOWK SRINAGAR PEERBAGH SRINAGAR BUDGAM JAMMU KASHMIR 190014 | BUDGAM | JAMMU AND KASHMIR | 190014 | L-3 | Rejected-Finance BEING L-3 | |
| 4 | L-4₹29.1 L+₹2.7 L (10.2%)Rejected-Finance R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-4 | Rejected-Finance BEING L-4 | |
| 5 | L-5₹31.0 L+₹4.5 L (17.2%)Rejected-Finance | L-5 | Rejected-Finance BEING L-5 |
Tender Value
₹34.6 L
EMD Value
₹69,200
Closing Date
2 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS C/O 56 APO
PROVN OF SENTRY POSTS AND FLOOR TILING IN OR LIVING BARRACKS AT CERTAIN UNITS UNDER AGE B AND R P OF GE 861 EWS
2022_MES_543074_1
GE 861EWS-43/2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹69,200
Yes
30 Sept 2022
3 Aug 2022
9 Sept 2022
3 Aug 2022
2 Sept 2022
19 Aug 2022
Amount
Demolition of cement concrete (unreinforced) in ground floors & paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches n exc 1.50m wide and n exc 1.50m in depth for foundation etc or for shaft wells, cesspits manholes pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
RCC M-25 design mix using 20 mm graded aggregate in foundations, including rafts, footings, foundation beams, plinth beams, base for columns, etc basements slabs under rammed piles and mass concrete complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in beams, cantilevers, bressummers lintels over 1.5 m span complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate in column, pillars, piers, posts and struts complete all as specified and directed.
RCC M-25 design mix using 20 mm graded aggregate as in slab supported on walls, beams and columns in floors, roofs landings balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Form work to sides of concrete foundations, footings, bases of columns, raft beams sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Form work to sides and soffits of floor or roof beam haunching , lintels, cantilevers shelved including supports overhangs etc also splays between floors and beams, etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finish surface of concrete square, rectangular or polygonal complete all as specified and directed.
Form work to sides and soffits of suspended slab such as roof slab, floor slab, shelves and similar works n. exc. 200 mms thick (Horizontal or sloping), finishing rought the concrete surfaces, complete all as specified and directed.
MS TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not les than 0.9 mm dia or securing with clips quality conforming to complete all as specified and directed.
MS TMT Bars of 5 mm dia and over up to 10 mm dia in stirrups, spacers and binders, cut to length bent to shape required including cranking, binding spirally for hooping for columns hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Walling of random rubble masonry with best quality stone, uncoursed, well bonded, bedded and solidly hearted and built in CM 1:4, all as specified.
Precast cement concrete type C-1(using 16mm graded crushed stone aggregate) hollow block masonry with hollow blocks exceeding 10cm in width and setting in mortar 1:6, complete all as specified and directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 finished the surface even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in CM 1:6 finished even and smooth without using extra cement, complete all as specified and directed.
5mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:3 finished the surface even and smooth without using extra cement, complete all as specified and directed.
Plain cement concrete M-10, 1:3:6, type C-2, using 40mm graded mechanically crushed stone aggregate, 75mm thick, as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified and directed. Note:- The unit rate include for use of form work (straight or curved).
75mm thick PCC 1:3:6 Type C-2 (40 mm graded stone aggregate) as in sub-base of floors, complete all as specified and directed.
40mm thick PCC 1:2:4 Type B-0 (12.50mm graded stone aggregate) as in sub-floor, sub-base, floor and pavings, etc., complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.06 sqm but not exc 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6, complete all as spcified and directed.
Chequered coloured cement concrete tiles of size 200 x 200 x 25mm thick, glossy finished, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid in floors, over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Rolled sections as in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in cluding cleats, brackets, etc. complete, conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
35mm thick, 2nd class hardwood factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
30mm thick, 2nd class hardwood factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (b) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, worught, framed rebated on the solid, rounded of chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
6mm thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed in ceiling flat and sloping with nails to timber frame, complete all as specified and directed.
2nd class softwood plain fillets square/rectangular or triangular in section of sectional area exc 13 Sqcm but n exc 25 Sqcm, complete all as specified and directed.
2nd class softwood plain fillets bull nosed splayed chamfered or rounded on one edge or face in section of sectional area exc 6 Sqcm but n exc 13 Sqcm complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plaind steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mps as in roof covering /cladding to wall, fixed with self tapping screws as specified and directed.
200mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
150mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
125mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
125mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
75mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed.
3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying two coats of cement base paint (camouflage pattern) over a coat of alkali-resistant priming coat, completed all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including PVC casing and capping/Conduit medium grade of suitable size run on wall/surface with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size or PVC Gang Box with 3 mm thick plastic laminated sheet cover of adequate size for one light point/fan point controlled by one switch and making good disturbed surfaces with CM (1:3) to match with the existing surface, complete all as specified and directed.
All as per srl item No-54 here in above but for one 3 pin 5A socket outlet independent controlled by one switch, complete all as specified and directed.
All as per srl item No-54 here in above but for one 5A socket outlet on the same board controlled by one switch, complete all as specified and directed.
All as per serial item No 54 here-in-before but for 3 pin 15 Amps socket outlet independent board with 2.5 sqmm PVC FRLS insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 Sqmm PVC FRLS insulated unsheathed copper conductor single core cable (green color) as earth lead, complete all as specified and directed.
Switch piano flush button types 6 Amp, single pole, one way complete all as specified and directed.
Socket outlet, 3 pin, 6 Amps flush type, complete all as specified and directed.
Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp, flush type universal, complete all as specified and directed.
Stepped type electronic fan regulator flush type, AC 230 volts, duly ISI marked including connector on the existing sheet etc. as reqd., complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
LED lamp 9 W, complete all as specified and directed.
LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
MCB Distribution board , 240 volts single pole and neutral , double door, sheet steel, enclosure powder coated with 100 Amps rated copper busbar with neutral link, 4 ways, IP-43 protection and making good disturbed surfaces of walls etc, including two coats of white/colour washing/distempering etc to match the existing surface, complete all as specified and directed.
MCB, SP, AC, 240 volts "B" series capacity of 06 to 32 Amps, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts "C" series capacity of 32 Amps, 10kA and making connections, complete all as specified & directed.
Supply and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor (solid), served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10.0 sqmm, complete all as specified and directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00, BEE 5 star rated with brushless direct current motor (BLDC), complete all as specified and directed.
BHAT CONSTRUCTIONS AND BUILFERS
M/S Sofi Brothers
M/S GASSI CONSTRUCTION AND CO
JANDOO AND CO.
NAJAR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .