Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹43.4 L+₹95,223.39 (2.25%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹43.4 L+₹97,139.50 (2.29%)Rejected-Finance SHYAM BHAWAN OPP BANK OF INDIA CHOPASNI ROAD JODHPUR 342003 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
28 Mar 2022, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer -345001
PROVN OF 3 PHASE LT CABLE AND ASSOCIATED WORKS AND HIGH MAST TOWER AT MIL STN JAISALMER
2022_MES_511074_1
8172/21-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹60,000
Yes
23 Jun 2022
28 Feb 2022
30 Mar 2022
28 Feb 2022
28 Mar 2022
14 Mar 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in hard rock complete all as specified & directed by Engineer-in-Charge. Note (i) Hard rock obtained from excavation shall be stacked properly. Stacked hard rock shall be measured by deducting 50% quantity for voids for hard rock, remaining quantity will be considered of soft/disintegrated rock. (ii) Hard rock obtained shall be issued under Schedule of credit, which shall not be allowed for uses in work.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated materia soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar all as specified & directed by Engineer-in-charge.
M&L for plain cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge.
S&F of Second class hard-wood in scantlings(timer framed and fixed as per details of wooden flooring) bearer size 100mm x 150mm and joist size 75mm x 120mm with required cleat and bolt all as speficified and directed by Engr-in-Charge
S&F boarding in flooring & skirting Planed one side, with butt joints and fixed with nails supplied and fixed Softwood 2nd class 40mm thick in flooring and polished all as directed and specified by Engr-in-Charge
S&F of accord decorative wood acoustic wall paneling and polished all as per specified and directied by Engr-in-Charge
M&L for Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified.
M&L for Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S & F 12mm thick pre-laminated particle board, exterior grade, prelaminated both side with decorative choice lamination complete all as specified.
S&F, 5.5 mm thick sheet glass, ordinary quality and glazing in squares exceeding 0.5 Sqm in each pane with beads all as specified & directed by Engineer-in-charge.
S&F aluminium die cast body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed approved by Engr-in-Charge
S & F mild steel sliding bolt 300 mm long plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer-in-charge.
S & F Butt hinges Aluminum 100 mm type C21 complete all as specified and directed by Engineer-in-charge.
S & F aluminium handle 125 mm cast type anodized complete all as specified and directed by Engineer-in-charge.
S & F aluminium anodized tower bolt 150mm size complete all as specified and directed by Engineer-in-charge.
Taking down chowkat (without taking of shutter from the frame) not exc 1.5 sqm each including making good the disturbed surface in PCC 1:2:4 type B0 or CM 1:3 and white wash and cement base paint finished complete all as specified and directed by Engineer-in-charge.
All as per item No 19.00 above but exc 1.5 sqm and n exc 4 sqm each
M&L Precast cement concrete block masonry with solid blocks PCC (1:3:6) type C1 exc 10cm in width and setting in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement morter 1:4 on fair face of brick wall or concrete surfaces, finished even & fair complete all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered wall surfaces of any description and applying two coats of oil emulsion distemper over a coat of putty on wall for making uniform smooth surface and primer complete all as specified and directed by Engineer-in-charge.
S&F anodised aluminium snap grid frame work 600x600mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long complete all as specified and directed by Engineer-in-charge. Note :- Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm.
M&L 12mm thick medium density fibre board, exterior grade, fixed to timber framework with screws complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of ceiliing and applyg two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 core complete all as specified and directed by Engineer-in-charge.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core complete all as specified and directed by Engineer-in-charge.
Taking down the old existing unsv LT Cable of any type and any size complete all as specified and directed by Engr-in-Charge.
Taking down the old existing unsv LT pane of any capacity complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness shall only measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
M&L for bore earthing not less than 250mm dia 16 feet deep filled with black soil upto 7 feet from bottom complete with galvanised iron pipe 40mm bore medium grade 3m long tapers at bottom & provided 12mm holes (staggered) at 75mm centre to centre upto 2.5m of length from bottom, burried directly in ground filled with 45cm alternate layer of magnisium sulphate, charcol & salt up to ground level & connected to galvanised iron strip 32x6mm above ground level as earthing lead by means of bolt and nut, check nuts and washers of galvanised iron or steel including brazing work upto equipment and 40mm dia light grade GI pipe for earth lead protection and testing on completion complete all as specified & directed by Engineer-in-charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
S&F GI pipe light grade of dia 40 mm laying in road and along with poles for cable protection including taking down existing unserviceable GI pipe complete all as directed by Engr-in-Charge.
S&F GI pipe light grade of dia 50 mm laying in road and along with poles for cable protection complete all as directed by Engr-in-Charge.
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete all as directed by Engr-in-Charge.
S & F LT cable route indicator made out of cast iron plate of 150 mm dia 4 thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm) complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the tenderer shall be deemed to inclusive of earth work, excavation, PCC etc, complete.
Supply, installation, commissioning and testing of LT panel (CPRI Approved) out door type 415 Volts, 50 Hz, 3 Phase 4 wire supply Padastal mounted double door center opening with lockng arrangement, factory assembled, weather and vermin proof (protection class IP-54) canopy on top, outer door made out of 3.15 mm thick CRCA sheet for individual hinged type door for MCCBs, powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading, complete to accommodate including the following:-
Supply, installation, commissioning and testing of LT panel (CPRI Approved) out door type 415 Volts, 50 Hz, 3 Phase 4 wire supply Padastal mounted double door center opening with lockng arrangement, factory assembled, weather and vermin proof (protection class IP-54) canopy on top, outer door made out of 3.15 mm thick CRCA sheet for individual hinged type door for MCCBs, powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading, complete to accommodate including the following:-
(a) 4 No's alumnium bus bar of rating 800 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly) (b) MCCB 400 Amps 36 kA 4 Pole adjustable type -01 No (Incoming) (Icu = 100% Ics) (c) MCCB 250 Amps 25 kA 4 Pole adjustable type -01 No. (Outgoing) (Icu = 100% Ics) (d) MCCB 160 Amps 25 kA 4 Pole adjustable type -02 Nos. (Outgoing) (Icu = 100% Ics) (e) Digital type VAF meter-01 No (f) 100/5A, 5VA, CTs-03 Nos (g) Indicating lamp LED type set of three -01 No (h) Danger Notice board for LT 415 Volt.
Supply, installation, commissioning and testing of LT panel (CPRI Approved) out door type 415 Volts, 50 Hz, 3 Phase 4 wire supply Padastal mounted double door center opening with lockng arrangement, factory assembled, weather and vermin proof (protection class IP-54) canopy on top, outer door made out of 3.15 mm thick CRCA sheet for individual hinged type door for MCCBs , powder coated and supported on 50 mm x 50 mm x 6 mm angle iron frame and 3.15 mm thick MS rubber beading, complete to accommodate including the following:-
(a) 4 No's alumnium bus bar of rating 400 Amps mounted on heavy duty rubberised/porcelene support two set (Vertically and horizontaly) (b) MCCB 160 Amps 36 kA 4 Pole adjustable type -01 No (Incoming) (Icu = 100% Ics) (c) MCCB 100 Amps 25 kA 4 Pole adjustable type -02 Nos. (Outgoing) (Icu = 100% Ics) (d) Digital type VAF meter-01 No (e) 100/5A, 5VA, CTs-03 Nos (f) Indicating lamp LED type set of three -01 No (g) Danger Notice board for LT 415 Volt.
S& F High Mast Lighting tower 16 Metrer in two section with top 3mm and bottom 4mm having top diameter 150mm and bottom diameter 360mm suitable for 09 LEDs fixtures of 250watt with lighting protection finial GI single spike length 1200mm & lantern carriage of 9 arm in two segments having double drum winch of capacity SWL 500 KG self lubricating & stainless steel wire rope of grade AISI1316 dia 6mm having number of rope 3 Nos of 6mm for lantern carriege and 2 Nos of 6mm for double drum winch, having breaking load capacity 2350 Kgs per as wire rope with raising cable flexible copper 5 core 2.5 Sqmm and moter of capacity 1.5 HP single speed reversible type 415 Volt/240 Volts complete with anchor plate & template foundation bolts & nuts and with complete foundation as per manufacturer drawing and specification complete all as specified and directed by Engr-in-Charge. Note : High Mast lights should be of same manufacture.
S&F High Mast Light Integral type LED Flood Light of 250 Watt with 10KV Surge Protection IP-66 complete for high mast light aaplication complete with fixing arrangment & bolts complete all as specified & directed by Engineer-in-charge.
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 25x4mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified & directed by Engineer-in-charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, installation, commissioning and testing of High Mast Timer Panel tappered (CPRI Approved) out door type 415 Volts, 50 Hz, 3 Phase 4 wire supply Padastal mounted center opening with locking arrangement , factory assembled, weather and vermin proof (protection class IP-54) canopy on top, outer door made out of 3.15 mm thick CRCA sheet for individual hinged type door for MCBs , powder coated and supported on 40 mm x 40 mm x 5 mm M.S angle iron frame complete to accommodate including the following:-
(a) TPN MCB 32 Amp-01 No (b) TP Contactor 25 Amp-01 No (c) TP Contactor 9 Amp-02 Nos (d) Digital Timer Switch astronomical type-01 Not (e) SP MCB 6 Apm-01 No (f) Push Button-02 Nos (g) Toggle Switch-01 No (h) Glass Fuse-01 No (j) Neutral Link-01 No (k) Terminals (a) Incoming Suitable 35 Sqm-01 No (b) Outgoing 16 Sqmm(Close Type)-04 Nos © Outgoing 6 Sqmm (Close Type)-03 Nos
S&F LED Aviation Light single dome suitable for High Mast Light complete with fixing arrangment & bolts complete all as specified & directed by Engineer-in-charge.
Taking down existing unsericeable point wiing of any description /type size of light/fan/tube/power /two way /bell etc on TW batten/conduit including removal of batten .conduit gutties /wooden boards /switches /sockets/regulators /light fittings etc and removal of u/s material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down the existing unserviceable main switch /cut out/DBs of any type /capacity description as existing at site including MCBs any type and capcity making good the disturbed surfces to match with the existing finishes all as specified.
Taking down carefully the existing unserviceable submain wiring of any description with PVC surface conduit or casing caping and making good disturbed surfaces complete.
Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
(a) One light point controlled by one switch.
(b) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(c) One socket outlet 6 amp controlled by one switch on indepdendent board.
Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 4.0 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 4.0 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
S&F modular switch one way 6 A , 1 module
S&F modular socket 6A-2/3 pin combined 2 module
S&F modular switch socket combined 6A/16A, 3 pin 3 module
S/F vertical DBs TPN 8 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer with MCCB 160A , and with provision of SP/TP MCB's as outgoing MCCB FP 160A, 25 KA complete all as specified and directed.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
Supply and fixing MCB's TPN 40 to 100 Amps, 415 Volts,10 kA rapturing capacity 'C' curve complete all as specified and directed.
Supply and fixing MCB's single pole and neutral 40 to 63 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified and directed.
Supply and fixing MCB's single pole 20 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified and directed.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge.(Note :- (i) Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of conduit shall be paid as one unit length). (ii) Rate quoted by the contractor shall deemed to inclusive of cutting charges where necessary.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for three phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 25.00 Sqmm (FRLS) in conduit including two run of PVC insulated multistranded copper conductor nominal cross sectinal area of 16.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge.(Note :- Four runsof 25.00 Sqmm cable & one run of 16.00 Sqmm cable shall be paid as one unit length)
S&F Sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V 20 Amp for geyser complete all as specified and directed.
Supply and fixing of recessed mounted down lighter with extruded aluminium frame with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED 6K,ceiling cutout 2ft x 2ft with suitable lumen 2700/4300/6000k all as directed.
Supply and fixing of building security light fitting LED 30 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment and connecting as specified and directed. Make Havells cat pot No .EDDURAPEARLSL30WLED757SASYTOPCMP or equivalent as list of make)
S& F in repair bracket of GI pipe medium grade of 40mm dia,1.2 meter in length clamps made of FI 40 mm x 6mm incl nuts ,bolts & washers, painting complete as specified.
M&L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron strip 32x6 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing on completion complete including taking out old earthing all as specified & directed by Engr-in-Charge.
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
M& L Earthing Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and scewed including 3 nos 8 mm dia 25 mm long hex head screw.
Supply, installation, commissioning & testing of hi wall split type air conditioner of capacity 2 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser, plasma filter for better indoor air quality 5 star rating non CFC type with nominal cooling capacity including Hot & cold system complete all as specified and directed by Engineer-in-charge.
Supply, installation, commissioning & testing of hi wall split type air conditioner of capacity 1.5 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser, plasma filter for better indoor air quality 5 star rating non CFC type with nominal cooling capacity including Hot & cold system complete all as specified and directed by Engineer-in-charge.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA.
M/s Shree Construction Company
Shri Maruti Trading Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .