SUPERINTENDING ENGINEER
OFFICE OF THE SE EUDC NUMAISH CAMP MUZAFFARNAGAR
The work of relasing of connection of 785 KW (LMV-7) at 22 MLD STP Jansath road on the Sahavali Nala under Namami Gange programme in the area of Electricity Urban Distribution Division-I, Muzaffarnagar
2023_PVVNL_775347_1
SHORT TERM E-TENDER NO. 62/2022-23 OF EUDC MZN
Open Tender
Electrical Works
Lump-sum
90 days
IN THE AREA OF EUDD-I
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE EUDC MUZAFFARNAGAR
₹16,500
Yes
14 Mar 2023
15 Feb 2023
28 Feb 2023
15 Feb 2023
28 Feb 2023
15 Feb 2023
Amount
Carriage of Following line materials from ESC, Muzaffarnagar to work sites including safe loading and unloading at both ends as per site condition (0 to 15 km.)
11 KV VCB out going
ST Pole 11 mtr Long
ACSR Rabit Conductor
11 KV Composit Polymeric Pin insulater
Disc fitting 45KN
Stay Set complete
GI wire 4MM 8-SWG
11 KV TVM Meter Category-C
11 KV composit polymeric disc insulater
MS Chanel 100X50MM
11 KV XLPE cable jointing KIT I/D 3X120 SQMM
11 KV XLPE cable HT 3X120 SQMM
MS angle 65X65X6 MM
11 KV draw out fuse set
Earth road
11 KV XLPE cable jointing KIT O/D 3X120 SQMM
GI X-ARME angle 65X65X6 MM V-TYPE
11 KV CT/PT O/D Combine unit
Meter cubical pilfer froof 11 KV CTR 50/5AMP
Safely installation of 11 KV VCB out going panel at Sub Station
Connection with existing bus coupler of new 11 KV VCB outgoing panel (Fixing All Accessories As per Norms)
Errection of 11 KV Double Pole for STP 11 Mtr. long pole with fixing all accessories as per norms (Nuts, Bolts, Washer and Clamps will be provided by contractor)
Errection of 11 KV Four Pole for STP 11 Mtr. long pole with fixing all accessories as per norms (Nuts, Bolts, Washer and Clamps will be provided by contractor)
Errection of 11 KV single support for STP 11 Mtr. long pole with fixing all accessories as per norms (Nuts, Bolts, Washer and Clamps will be provided by contractor)
Febrication of MS channel/angle
Spreading And Sagging of ACSR Rabit Condouctor
Work Of 11 KV Line Gaurding (Fixing All Accessories As Per Norms)
Errection of stay complete and Grouting of stay rods including all work of excavation, cement concreet in size .60x.60x.30mm in ration 1:4:8 (Cement, sand, 40mm brick ballast) as per drg. including back filling & proper ramming etc. with fixing tightening & nuzzling of stay set with the pole
Grouting of STP pole with cement, sand, bricks CC ratio1:4:5 as per RESPO norms (all materila provided by contractor)
Leaying and pulling of 11 kv XLPE cable 3x120 sqmm through HDPE pipe and GI pipe properly from Double Pole to out going new vcb panel as per norms (HDPE Pipe and GI Pipe will be provided by contractor)
Filling and connect 11 KV XLPE 3x120 sqmm cabble Jointing Kit I/D with 11 KV VCB Panel (Fixing All Accessories As Per Norms)
Wearing and Fixing 150 MM DIA 4.0 Mtr GI Pipe Over 11 KV 3x120 SQMM For XLPE Cable and Provided GI Pipe
Filling of 11 KV XLPE 3x120 sqm calbe Jointing Kit O/D and connect with double pole as per norms.
Digging of tranch 0.75 mtr deep of leaying of 11 KV 3x120 sqmm cable and Laying of HDPE Pipe in the Tranch Including Proveding OF HDPE Pipe 150 MM DIA.
Errection Of 11 KV CT/PT O/D combine unit (Fixing All Accessories as per norms)
Errection Of 11 KV Meter cubical pilfer proof 11 KV CTR 50/5 amp. (Fixing All Accessories as per norms
M/S ABID CONTRACTOR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .