Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-Finance Lowest one | |
| 2 | L2₹23.5 L+₹2.0 L (9.24%)Rejected-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.2 L+₹2.7 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹28.4 L+₹6.9 L (32.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹31.2 L+₹9.7 L (45.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹99,980
Closing Date
3 Sept 2024, 6:00 pmClosed
GE (NW) NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIR REPLACEMENT OF DETERIORATED INTERNAL EM COPPER WIRING FITTING FIXTURES ALONGWITH LED LIGHTS AND CONNECTED ITEMS AT OUTLAYING AREA UNDER GE (NW) NOFRA COLABA MUMBAI
2024_MES_662086_1
8289
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Mumbai
Please refer tender documents.
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹99,980
Yes
30 Sept 2024
25 Jun 2024
5 Sept 2024
25 Jun 2024
3 Sept 2024
19 Jul 2024
25 Jun 2024 - 2 Jul 2024
Amount
Note : (a) Uniform for all deployed staff in duty supervisor as approved by GE. (b) Functional tools & plants shall be carried by tradesman all time for attending any site. (c) Necessary ladder / cloth or any other material reqd. (d) Debris / site clearance immediately before leaving site. (e) Safety eqpt to be carried all time. (f) In case of non-adherence of any of above fine/ penalty to be carried as under:- (i) 1st Time - Rs 200/- (ii) 2nd Time - Rs 500/- (iii) 3rd Time - Warning to contractor. (g) In case of 3 warning to contractor, it will be reflected in WLR for slow progress. (h) Complaint registered upto 11:00AM & emergency complaint to be attended same day. (j) Complaint Team consist of 02 Electrician alongwith reqd helpers.
Taking down carefully aluminium/ copper point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC Casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement , ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(f) One bell point controlled by one bell push 5 Amps.
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour point wiring for Geyser /AC complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC casing caping of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specified and directed by Engr in Charge.
Supply and fix Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by Engr in Charge.
S&F Modular type bell push , 6Amp, 1 module, ISI marked complete all as specified and directed by Engr in Charge.
S&F Bell electric AC 230Volt single pole musical type, ISI marked complete all as specified and directed by Engr in Charge.
Supply and fix support function blank plate single, 1 module complete all as specified and directed.
Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed.
Supply and fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified.
Supply and fix Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module.
Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed complete all as specified and directed by Engr in Charge.
Supply and fix Modular white cover plate with Frame 2 Module complete all as specified and directed.
Supply and fix Modular white cover plate with Frame 3 Module complete all as specified and directed.
Supply and fix Modular white cover plate with Frame 4 Module complete all as specified and directed.
Supply and fix Modular white cover plate with Frame 6 Module complete all as specified and directed.
Supply and fix Modular white cover plate with Frame 8 Module complete all as specified and directed.
Supply and fix Modular white cover plate with Frame 12 Module complete all as specified and directed.
Supply and fix Modular metal flush box 2 module including cutting, chassing, filling putti & good make of distrubed surface and matching with existing colour complete all as specified and directed.
All as per item No 20 but metal flush box 3 module.
All as per item No 20 but metal flush box 4 module.
All as per item No 20 but metal flush box 6 module.
All as per item No 20 but metal flush box 8 module.
All as per item No 20 but metal flush box 12 module.
Supply and fix in replacement Polymer extruded channel, with opaque diffuser for glare free light 1x18/20 WH 04 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.
Supply and fix in replacement Polymer extruded channel, with opaque diffuser for glare free light 1x10 WH 02 feet long accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size with all accessories complete all as specified and directed.
Supply and fix in replacement Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket for window type air conditioners or geyser complete all as specified and directed by Engr in Charge.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by Engr in Charge.
Supply and fix submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. [Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping]
Supply and fix submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 6 sqmm (green colour) for earthing. [Note :- (i) Two runs of 6 Sqmm cable, 1 run of PVC casing & caping and 1 run of 6 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping ]
Supply and fix submain wiring with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing and caping of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. [Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing & caping and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping ]
Supply and fix submain wiring cable Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 3 core , 10 Sqmm and including laying , sadling with clamps, / laid in duct / along pole/wall etc including making connection to DB complete all as specified and directed by Engineer-in-Charge. [Note :- (i) Two runs of 10 Sqmm cable, 1 run of PVC casing & caping and 1 run of 10 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC casing caping ]
Supply and fix in replacement sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed by Engr in Charge.
Supply and fix in replacement sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed.
S&F in repair MCB SPN (DP) 40 to 63 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.
S&F in repair MCB SP 6 to 32 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed by Engr in Charge.
S&F in repair MCB TPN (four pole) 40 to 100 Amps, 240 Volts, C curve, 10 KA complete all as specified and directed by Engr in Charge.
Material and labour for cleaning all dust, filling cavities with filler, prepartation of surfaces, painting of ceiling fans , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed.
Material and labour for cleaning all dust, filling cavities with filler, prepartation of surfaces, painting of Exhaust fan , in situ with one coat of synthetic enamel paint by spray painting complete all as specified and directed by Engr in Charge.
M & L for rewinding of unserviceable ceiling fans lot size 1200/1400 sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing split/ quarter pins, rubber bush, capacitor 2.5 Mfd and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
M & L for rewinding of unserviceable exhaust fans lot size 225/300/450/630mm sweep with approved copper enamalled wire of suitable guage, varnishing, replacing existing nut bolts pins, rubber bush, capacitor , bearing ,m bush, frastner etc and including taking down and refixing in exsiting position and testing complete all as specified and directed by Engr in charge.
S&F in repair Switch 5 Amps piano type, single pole 230 Volts complete all as specified and directed
S&F in repair switch socket combination multipurpose for 3/2 pin 5 Amps flush type ISI marked complete all as specified and directed.
S&F in repair switch socket combination multipurpose 2 in 1 for 3 pin 15 Amps & 3pin 5 Amp controlled by one switch flush type complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type 450 Watts, complete ISI marked all as specified and directed
Supply and fixing in repair Capacitor 2.5Mfd complete all as specified and directed.
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed.
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as directed by Engineer-in-Charge.
Supply and fixing GI strip 32/6 for building earthing and sadling in high rise bldg wall (G+ 15 floor), cable trench, building cable duct from the LT panel to DB up to height of 50 RM from ground and fix properly all as directed by Engr-in-Charge
Taking down unserviceable light and Supply and fixing Ceiling light 36 WATT 2 ft X 2 ft Recess mounting led ultra slimceiling light with extruded aluminium housing and milky diffuser.LED ultra slim panel complete all as specified and directed.
M&L for stopping the leakage of the geyser of any capaciry by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by engr-in-charge. [Note : Adequate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank leaked the same will be repaired by the contractor witout claiming any additional cost from the department.]
S&F in replacement of heating element as required at site of 1.5 KW ISI marked as required at site and approved by Engr-in charge.
S&F in replacement of heating element as required at site of 2.0 /3.0 KW ISI marked as required at site and approved by Engr-in charge.
S&F in replacement thermostate switch for geyser of any type ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement thermmal cut out for geyser of any type ISI marked complete all as specified and directed by engineer in charge.
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 06 Ltr complete all as specified and directed by engineer in charge.
S& F in replacement geyser steel inner tank assembly suitable for geyser capacity of 25 Ltr complete all as specified and directed by engineer in charge.
S&F in replacement steel inner tank for geyser of 03 Ltr capacity complete all as specified and directed by engineer in charge.
S&F CP in replacement non return valve 15mm bore with air lock relase arrangement ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement of glass wool for geyser of 6/25 ltr complete all as specified and directed by engineer in charge.
S&F in replacement of inspection cover stainless steel in 2 piece suitable for gesyer of 50/25/6 ltr capacity and having provision of fixing indiactor lamps complete all as specified and directed by engineer in charge.
S&F in replacement PVC insulated 3 core circular stranded copper conductor of 2.5 sqmm complete all as specified and directed by engineer in charge.
S&F in replacement CP gate valve of 15 mm bore suitable for existing fittings complete all as specified and directed by engineer in charge.
S&F in replacement hot water extension pipe made out of copper chromium plated 450 mm long with brass adaptor in existing position complete all as specified.
S&F in replacement Cold water extension pipe made out of copper chromium plated 450 mm long with brass adaptor in existing position complete all as specified.
S&F in replacement 15 mm Bib taps, cast copper alloy with crutch or round handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S&F in replacement hot water PVC pipe 15 mm bore with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site all as specified and as directed by engr-in-charge. [Note: Rate quoted shall also include the plumber work as per site requirements.]
S&F in replacement of top plug 15 Amp 3 pin complete all as specified and directed by engineer in charge.
Supply and fix in replacement electric water heater,instant type steel body with copper inner tank testing and commissioning of water heater (geyser) vertical type of 03 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 3000 watts, ISI marked, BEE 5 star rating including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete all as specifed and directed by Engr-in-Charge. (a) Taking down U/S geyser of any capacity will be deposited in MES store yard
S&F in replacement indicating lamp green/red in colour 230 volts complete all as specified and directed by engineer in charge.
Supply & Fixing 3 inch / 4 inch long 12 mm to 20 mm dia fastner including bolt , pin , washer complete all as specified and directed by engineer in charge.
Supply and fix PVC water tank top cover double lock of capacity of tank 500 Ltr to 2000Ltr design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.
Supply and fix PVC water tank top cover double lock of capacity of tank 3000 Ltr to 10000 design in round shape to provide complete coverage and protection to the water tank and equipped with a closing lid mechanism ensuring secure sealing and preventing contaminants from entering the water complete all as specifed and directed by Engr in Charge.
Checking serviceability of all geyser in each quarter and checking fastner nut, bolts, pins indicator lamps , NRV, thermostate , thermal cut out etc are in healthy condition If any problem in any items will be note down by electrician and informed concerned JE E/M and rectify the problem next day complete all as specified and directed by engineer in charge.
Supply and fix in repair Linear Aluminium Baten, inbuilt sensor based on smart LED auto dimmable from 100% of rated wattage to 30% on sensing of movement/occupancy, baten 10W Aluminium Extruded Chanel Powder Coated with opaque diffuser for glare free light complete with accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified.
B P ENTERPRISES (BID ID -3071266)
M/s Qureshi Construction Co (BID ID -3070583)
NOEL ENGINEERS (BID ID -3076434)
M/S V N ENTERPRISES (BID ID -3073400)
shubham construction (BID ID -3071534)
N.S.ENTERPRISES (BID ID -3070503)
SHREE JAGDISH FURNITURE CO. (BID ID -3069269)
Nayana Electric Corporation (BID ID -3067172)
DHARMESH ENTERPRISES (BID ID -3069271)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .