Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.9 LAdmitted-Finance VILL KAKDWIP SUBHASH NAGAR P O KAKDWIP DIST SOUTH 24 PARGANAS PIN 743347 | KAKDWIP | SOUTH 24 PARGANAS | WEST BENGAL | 743347 | -0.05% | ₹9.9 L | L1 | Admitted-Finance |
| 2 | L2₹10.2 L+₹28,177.29 (2.85%)Admitted-Finance 104 SARAT GHOSH GARD EN ROAD CAL 31 700031 | KOLKATA | WEST BENGAL | 700031 | +2.80% | ₹10.2 L+₹28,177.29 (2.85%) | L2 | Admitted-Finance |
| 3 | L3₹10.2 L+₹30,154.64 (3.05%)Admitted-Finance 15A PALMER BAZAR ROA D CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | +3.00% | ₹10.2 L+₹30,154.64 (3.05%) | L3 | Admitted-Finance |
Tender Value
₹9.9 L
EMD Value
₹20,000
Closing Date
26 Feb 2026, 5:00 pmClosed
D.G ( S and D)
5 , S. N. Banerjee Road Kolkata , 700013.
Manufacturing, fabrication, supplying and commissioning of MS base plate structure with feeder pillars for solar panel installation at Itkhola-I under KMC.
2026_KMC_1008121_1
KMC/S_D/ITKHOLA/BP/25-26
Open Tender
Electrical Work/ Equipment
Percentage
7 days
Itkhola
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹20,000
6 Aug 2026
18 Feb 2026
28 Feb 2026
18 Feb 2026
26 Feb 2026
18 Feb 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, fifling & fixing of M.S fabricated pedestal stool of suitable size, consisting of bottom plate, top plate, four nos legs etc febricated with suitable sizes m.s plate, m.s angle conforming to I.S 2062 of latest revision and as per approved drawing & direction of Engineer in charge. The cost includes cost of materials, man power employed for dismantling and fitting fixing, civil works consumables like cutting tools, gas, oxygen, welding rod, anchor bolt of required size, hire charges of machineries, like gas cutting set, welding set, tools & tackles etc including carriage loading & unloading.. ... Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE-2022 item no. 5.1 F-2, page no 85 | 585 | KG | 139 | ₹81,315 |
| 2 | Structural M.S Bolt/Nut/Washer (Black)…… Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE-2022 item no. 21, page no 68 | 520 | KG | 100 | ₹52,000 |
| 3 | Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint &provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3phase, 50 Hz, 4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere , Volt , selector switches, frequency , phase indicating lamp, Energy complete including cost of busbar supports, detachable cable gland plates,2 earthing terminals, internal wiring &fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere , Volt , selector switch as per approved design & specification. ... Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT MECH SCHEDULE-2022 item no. 5.3 D1, page no 105. | 295 | KG | 323 | ₹95,285 |
| 4 | Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and direction of E.I.C. c) For large size feeder pillar box.... Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 37, page no 7 | 3 | Each | 3,776 | ₹11,328 |
| 5 | Supply of aluminium busbar for electricat power distribution…………Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE-2022 item 5.3 D6, page no 105. | 38 | KG | 240 | ₹9,120 |
| 6 | Erection, testing & commissioning of up to 12.0 / 12.5 / 16.0 meter high mast on the existing civil foundation by bolts with suitable tools, tackles, machines etc, all complete, as per direction of the EIC. ... Rate as per UDMA ELECT-MECH SCHEDULE-2018 item no. 05, page no 54 | 13 | item | 25,483 | ₹3,31,279 |
| 7 | Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. …. Rate as per PWD Elect. Sch, rate 2017, ITEM NO. 3 A) page no-F-1. | 300 | RM | 46 | ₹13,800 |
| 8 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) f) 50mm dia 3mm thick Polythene Pipe. .... Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 1 f) page no-E-2 | 300 | RM | 65 | ₹19,500 |
| 9 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection Legrand, FP 100A. … Rate as per PWD Elect. Sch. rate - 2017 , ITEM NO. 10 page no-D-8. | 2 | item | 7,143 | ₹14,286 |
| 10 | Supply and delivery of extended rotary handel of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE) b) Extended rotary handle 100-160A, 415V … Rate as per UDMA ELECT MECH SCHEDULE - 2018 item no. 52 b), page no 21 | 2 | item | 1,015 | ₹2,030 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
Tendernotice_2.pdf
PDF • 0.66 MB
BOQ_2474245.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .