| 1.00Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish | ||||||
| 1.01 | 8 Mtr [E- 14 / 2(c)] | 43 | Pt. | 1,503 ₹64,629 | 750 ₹32,250 Lowest | 875 ₹37,625 |
| 2.00Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish | ||||||
| 2.01 | On Board [E- 14 / 4(a)] | 6 | Pt. | 220 ₹1,320 | 44 ₹264 Lowest | 68 ₹408 |
| 2.02 | 3 mtr. [E- 14 / 4(c)] | 9 | Pt. | 572 ₹5,148 | 372 ₹3,348 Lowest | 408 ₹3,672 |
| 3.00SUB-HEAD 2 - PLUGS & SOCKETS | ||||||
| 4.00 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connections as required [E-7 / 23] | 1 | no | 2,200 ₹2,200 | 510 ₹510 Lowest | 600 ₹600 |
| 5.00SUB-HEAD 3, SPNDB | ||||||
| 6.00Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. | ||||||
| 6.10 | 2+10 Way, Make - Legrand (Enclosure - 607712), Siemens (Enclosure - 8GB32102RC14) [D- 9/13] | 1 | no | 2,970 ₹2,970 | 1,550 ₹1,550 Lowest | 1,851 ₹1,851 |
Tender Value
Refer Docs
EMD Value
₹5,500
Closing Date
28 Feb 2024, 4:00 pmClosed
A.E, Hooghly Electrical Sub Division-I
Sarat Sarani Kodalia hooghly 712123
Repair, renovation of E I work at Annexe part of Hostel Building of ITI Hooghly.
2024_WBPWD_668522_1
WBPWD/HESD-I/ NIeQ-09/ 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
HOOGHLY
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,500
o/o the Assist. Eng, Hooghly Elec Sub Divn,PWD
16 Sept 2026
16 Feb 2024
1 Mar 2024
16 Feb 2024
28 Feb 2024
16 Feb 2024
19 Feb 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
8 Mtr [E- 14 / 2(c)]
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
On Board [E- 14 / 4(a)]
3 mtr. [E- 14 / 4(c)]
SUB-HEAD 2 - PLUGS & SOCKETS
Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite /perspex cover and making necessary connections as required [E-7 / 23]
SUB-HEAD 3, SPNDB
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+10 Way, Make - Legrand (Enclosure - 607712), Siemens (Enclosure - 8GB32102RC14) [D- 9/13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as per GS (Make-Legrand/Siemens) as per direction of EIC.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make-Legrand/Siemens/Schneider) as per direction of EIC.
S & F double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. L&T Enclosure (LTSD12N) with inbuilt locking arrangement (2+10 way) 1) S & F 24 Hr. timer (L & T AUTS03ANA00 , ) analog type – 1 no. 2) S & F 440 Volt 40A DP contactor (L & T, ML – 3 , SS90721) – 1 no. 3) 6 amp auto manual toggle switch – 1 no. (L &T) 4) Indicating lamp B & G (L&T) – 2 nos. 5) 440V, 40A, 10KA, C series TP MCB (L&T/ Legrand)on din rail for incoming- 1no. 6) 100A capacity 4W Brass stud type connector on FRP chair for I/C & O/G- 2nos All control circuit wiring would be made by 1x1.5 sqmm stranded Cu wire(FRLS) and the I/G & O/G circuit with 1x6sqmm copper wire maintaining colour code incl taping, socketing to complete the work. The box should be fixed on wall with suitable size of flush nut and necy. connection.
SUB-HEAD 4 - Laying of pipe & drawing of copper wire
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools
19 mm dia. 3 mm thick polythene pipe with 1x14 SWG GI earth continuity wire [E- 3 / 6(b)]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size [E- 16 /7 (a) ]
25mm size [E- 16 /7 (b) ]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
3 x (1.5 sqmm) [ E- 9 /1(b) ] (separate plug )
2x(2.5 sqmm)+1x(1.5 sqmm) [ E-9 / 1(s) ] (computer board)
2x(6 sqmm)+1 x (4 sqmm) [ E- 9 / 1(y) ] (HTPN to STPN)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 2.5 sq. mm. [ F-5 / 9 (i) ]
b) 4 sq. mm. [ F-5 / 9 (ii) ]
c) 6 sq. mm. [ F-5 / 9 (iii) ]
SUB-HEAD 5 - Laying of cable
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm. [F- 3 / 5(i)]
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make--Gloster/KEI/Polycab]
2 Core 6 Sq. mm (For compound illumination) [ NS ]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
2 Core 6 Sq. mm. [F4 / 7(b)]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
2 Core 6 Sq. mm. [ F5 / 8(b)-ii ]
SUB-HEAD 6 - Fixing of Light Fittings
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2 / 17]
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required [C-2 / 13(d)]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [ C-2 / 16 ]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [ 18/C-3 ]
SUB-HEAD 7 - Suppply of Light Fittings
Supply and delivery of Single Fittings (make- Philips, Cat No. TMC-501 P 1xT-LED 22W P3241 or equivalent model of CG / Bajaj / Wipro) incl. 1 no. 18W Master LED Tube [NS]
Supply and delivery of Twin Fittings (make- Philips, Cat No. TMC-501 P 2xT-LED 22W P3242 or equivalent model of CG / Bajaj / Wipro/Magik) incl. 2 nos. 18W Master LED Tube [NS]
Supply and delivery of flood lighting luminaire(Crompton TFS-504-100-57-60D-HL2-GL-NSG/Philips/Wipro/Magik) [NS] (for back side of the building)
SUB-HEAD 8 - Fixing of Fans
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire [ C-3 / 21(a) ]
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) [ D-14 / 29 ]
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire as per GS. [ C-3 / 21(b) ]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. [ E-6 / 18(a) ]
Engraving the deptt. number with 10 mm lettering on the body as per GS. [C-3 / 24(a)]
Extra for additional one letter incl. hifen, stroke and stop [ C-3 / 24(b) ]
Fixing only exhaust fan after making holes in wall as per GS
Supply & Fixing louver shutter ( Aluminium) on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS
SUB-HEAD 9 - Supply of Fans
Supply of ceiling fans complete with all accessories without regulator. ( Make -Crompton high speed/Usha/Orient)
1200 mm Sweep [NS]
Supply of heavy duty Exhaust fan (Make - Crompton TRANSAIR / EPC as approved by E.I.C.)
9"( 225 mm ) Ball bearing type [NS]
SUB-HEAD 10 - Miscellaneous
SSupplying & Fixing GI waterproof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sq. mm. PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. [ H5 / (H)5 ]
SUB-HEAD 11 - Earthing
Excavation of soil for installation of Earth Electrode and filling & ramming.
(a) For Soft Soil [ G-1/1(a) ]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ G-1/2(a) ]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [ G-2/3(a) ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [ G-2/4(a) ]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No. - 4 SWG [ G-2/5(a)(i) ]
Add GST @18% :- Rs.
Add LWC @1% - Rs.
A. R. CONSTRUCTION
ANEEK ENGINEERS CO OPERATIVE SOCIETY LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .