| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-Finance | ₹1.4 L | L1 | Accepted-Finance First Lowest |
| 2 | L2₹1.4 L+₹1,323.96 (0.96%)Accepted-Finance | ₹1.4 L+₹1,323.96 (0.96%) | L2 | Accepted-Finance Second Lowest |
| Sl No | Description | Qty | Unit | ALLWIN COOL SERVICE L1 | SRI GANESH REFRIGERATION L2 |
|---|---|---|---|---|---|
| 1.00 | Renewal by Supply and Installation of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of
Cooling
Dehumidifying
Air Circulating
Filtering | 2 | Nos | 46,130 ₹92,260 Lowest | 46,150 ₹92,300 |
| 1.01The installation works for the above split type AC units includes the following. 1.Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/O General) (Pediatric ICU) | |||||
| 2.00 | Renewal by Supply and Installation of 5KVA Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt-270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 2 | Nos | 4,600 ₹9,200 Lowest | 4,700 ₹9,400 |
| 3.00 | Renewal by Supply and fixing of MS stand to rest the Outdoor unit. | 2 | Nos | 970 ₹1,940 Lowest | 1,000 ₹2,000 |
| 4.00 | Renewal by Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) | 9 | Mtrs | 978 ₹8,802 Lowest | 1,000 ₹9,000 |
| 5.00 | Renewal by Supply and fixing of water drain pipe | 27 | Mtrs | 58 ₹1,566 Lowest | 70 ₹1,890 |
| 6.00 | Towards the charges for removal Split Type AC units. | 2 | Nos | 1,300 ₹2,600 Lowest | 1,400 ₹2,800 |
| 7.00 | Transportation Charge from Kanyakumari Medical College and Hospital | 1 | Job | 500 ₹500 Lowest | 600 ₹600 |
| 8.00 | GST | 1 | Nos | 21,036.24 ₹21,036.24 Lowest | 21,238.2 ₹21,238.2 |
Tender Value
₹1.4 L
EMD Value
₹1,400
Closing Date
18 Sept 2026, 10:00 amClosed
Executive Engineer (Elec),PWD.,Electrical Division
OFFICE OF THE EXECUTIVE ENGINEER (ELECTRICAL), PWD., Electrical Division, Tirunelveli.
Renewal of 2 Nos 2.0 TR Airconditioner units to the Pediatric ICU of Second floor, B block building in Kanniyakumari Govt. Medical College Hospital at Asaripallam in Kanniyakumari District.
2026_PWD_699569_1
5(19)EE/2026-27 dated.27.08.2026
Open Tender
Electrical and Maintenance Works
Lump-sum
30 days
Asaripallam
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1,400
21 Sept 2026
3 Sept 2026
18 Sept 2026
3 Sept 2026
18 Sept 2026
3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Renewal by Supply and Installation of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of
Cooling
Dehumidifying
Air Circulating
Filtering | 2 | Nos | 46,140 | ₹92,280 |
| 1.01 | The installation works for the above split type AC units includes the following.
1.Mounting / Fitting Indoor and outdoor units at their respective locations.
2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.
3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.
4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.
5. Leakage testing the entire system unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/O General) (Pediatric ICU) | - | - | - | - |
| 2 | Renewal by Supply and Installation of 5KVA Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt-270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. | 2 | Nos | 4,646 | ₹9,292 |
| 3 | Renewal by Supply and fixing of MS stand to rest the Outdoor unit. | 2 | Nos | 979 | ₹1,958 |
| 4 | Renewal by Supply and laying of 5/8" and 3/8" copper pipe (Extra beyond 3 metres supplied with AC unit) | 9 | Mtrs | 980 | ₹8,820 |
| 5 | Renewal by Supply and fixing of water drain pipe | 27 | Mtrs | 58 | ₹1,566 |
| 6 | Towards the charges for removal Split Type AC units. | 2 | Nos | 1,500 | ₹3,000 |
| 7 | Transportation Charge from Kanyakumari Medical College and Hospital | 1 | Job | 500 | ₹500 |
| 8 | GST | 1 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.85 MB
TNO54.pdf
Tender Documents • 0.79 MB
BOQ_840972.xls
BOQ • 0.39 MB
corrigendum5.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .