Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹24.5 L+₹73,939 (3.12%)Rejected-Finance SADAR BAZAR DANAPUR CANTT PATNA 801503 | PATNA | PATNA | BIHAR | 801503 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹26.5 L+₹2.7 L (11.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹26.9 L+₹3.1 L (13.2%)Rejected-Finance B 150 GROUND FLOOR BACK SIDE PANDAV NAGAR DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹29.3 L+₹5.5 L (23.3%)Rejected-Finance 32 GRAND SQUARE DANAPUR CANTT PATNA PIN 801503 | PATNA | PATNA | BIHAR | 801503 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
25 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT 801503
REPAIR MAINT OF LT OVER HEAD LINE LT CABLES AND OTHER ALLIED WORKS IN AGE EM UNDER GE DANAPUR CANTT
2022_MES_504564_1
8563/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DANAPUR CANTT
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹46,000
Yes
22 Apr 2022
29 Jan 2022
3 Mar 2022
29 Jan 2022
25 Feb 2022
12 Feb 2022
29 Jan 2022 - 11 Feb 2022
60 days
Amount
Dismantling of old unserviceable LT junction box including foundation after disconnecting of all elecrical connection complete.
Dismantling of old unserviceable LT feeder pillar box including foundation after disconnecting of all elecrical connection complete.
M&L for taking out old unserviceable cable of any size , GI pipe protection, bricks including separating serviceable bricks & set aside and removing un-serviceable bricks from position all complete as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable including taking out old bricks from trenches and set aside for reuse complete all as specified and as directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm each layer ,complete all as specified and directed.
Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand shall be measured 18 cm thick after punning.
Supply and laying sub class B bricks of size 25cmx15cmx7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
Supply and laying bricks obtained from item No: 3 for protection of UG cable complete all as specified and as directed.
M & L for horizontal boring by mechanically across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of BOQ).
M & L for Directional horizontal boring (trenchless boring) by piercing the ground with a drilling bit/head at a low angle. The bit is spun and pushed through the soil. ... When the boring reaches its destination, a pipe, line, or conduit is pulled back through the hole. across the existing road without disturbing the road surface for inserting 80/40 mm bore GI pipe all complete all as specified and as directed by EIC. ( Note :- GI pipe will be measured and paid respective item of BOQ).
Materials and labour for plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in sub base of floor complete all as specified and directed.
Materials and labour 50mm thick sand cushioning filling under floors or in foundations including watering and consolidation complete all as specified and directed by EIC.
Taking out & refixing of Machine pressed precast concrete interlocking paver block any shape and size confirming to IS: 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment complete.
S & F MS Galvanised chain link fencing 3.40 mm dia & 100mmX100mm mesh including line wires wt n.exc. 4.00 Kg/Sqm.
M & L for Machine pressed precast glazed colour reflective PCC interlocking paver block 60 mm thick mixed with grey cementand pigment laid dry and bedded on sand cushion complete all as specified and as directed by Engr-in-charge. The pattern of paver block shall be approved by GE and shall be of approved make. Note: Payment of sand cushion shall be measured and paid separately.
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / ZINDAL /prakash surya
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete. Make - TATA / ZINDAL / prakash surya
Laying only cable any sizes obtained from item No 3 with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Digging out incoming and outgoing cables of any sized from loops near/back side junction box/feeder pillar box/ LT panel in trenches, cutting burnt out uninsulated portion of cable and relaying refixing in trenches and returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminium lugs, complete all as specified and as directed.
Supply ,fabrication, installation and testing of LT out door type factory made CPRI Approved, water and vermin proof protection pedestal type junction box of size 900mmX600mmX400mm (over all dimension) made out of 3.15 mm thick CRCA sheet dully supported with mild steel angle iron of size 25X25X5mm vertical frame and legs with mild steel flat iron 25X5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of size 0.80m X 0.6m X 0.90m depth (0.30m below ground level and 0.60m above ground level ) and connections of all outgoing / incomming existing cable of any size drawing / digging out cable from loops in trenches inclusive of necessary excavation and earthwork as required and relaying the cables including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item. (a) Alluminium bus bar of size 50 mm X 6 mm X 400mm long wrapped with PVC sleeves with maintained the colour code and provision of making holes as required with nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (b) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation and testing of LT factory made CPRI approved water and vermin proof protection pedestal type feeder pillar box of minimum size 1000mm (Height) x 600mm (Breath) x 400mm (Depth), outdoor type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable and air ventilation arrangement including provision of cable looping box of size 450mm (Height) x 600mm (Breath) x 300mm (Depth) made out of 3 mm thick CRCA sheet with front side openable double door shutter hinged door and locking arrangement at back side complete painted with Powder Coated paint of approved shade and suitable for 3 phase 4 wire system 500 voltage grade complete wiring and all incoming connections with copper strip busbar of required size to MCCB input including PCC (1:3:6) type C-2 as in foundation of size 0.80m x 0.60m x 0.60m depth (30 cm below ground level & 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item.
(a) Aluminium strip busbar of current carrying capacity 400 amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with suitable size GI nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. b) Copper strip busbar of current carrying capacity 200 amps wrapped with PVC sleeves with maintained the colour code and provision of making holes with suitable size GI nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos. (c) MCCB adjustable thermal magnetic release type of IP 66 protection,4 poles, 415 Volts, Lcu = 100% Ics, 25 KA breaking capacity of rating 100 Amps including all fixing accessories with both ends spreader links - 01 No. (Make :- L& T / Legrand/Schneidder (d) Neon indicator lamp with holder (RYB) = 03 Nos (L&T/AE/C&S). (e) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No.
Supply, fabrication, installation and testing of LT Outdoor Panel of factory made CPRI approved water and vermin proof protection pedestal type of minimum size 1000mm (Height) x 600mm (Breath) x 500mm (Depth), outdoor type made out of 3.15 mm thick CRCA sheet with frame and legs of mild steel angle iron of size 40 x 40 x 6 mm in all side with double door, front and back side openable and air ventilation arrangement including provision of cable looping box of size 450mm (Height) x 1300mm (Breath) x 500mm (Depth) made out of 3 mm thick CRCA sheet with front side openable double door shutter hinged door and locking arrangement at back & front side complete painted with Powder Coated paint of approved shade and suitable for 3 phase 4 wire system 500 voltage grade complete wiring and all incoming connections with copper strip busbar of required size to MCCB input including PCC (1:3:6) type C-2 as in foundation of size 0.80m x 0.60m x 0.60m depth (30 cm below ground level & 30 cm above ground level) including necessary excavation and earth work complete all as specified and as directed alongwith comprising of the following accessories :- NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item.
Supply, installation, commissioning and testing LT Panel Board factory made CPRI approved panel, weather, dust & vermin proof outdoor cubical compartmental type, double door, front and back side openable, with providing rubber/PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip busbar of suitable rating toACBinput and ACB output of suitable length, made out of 3.15 mm thick mild steel CRCA sheet with 40 x 40 x 6mm size angle iron supporting frame and MC 75 channel base including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming including PCC foundation complete all as directed and specified and comprising of the following fitment accessories :-
OUTGOING :- (a) MCCB, of IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 160 Amps, adjustable thermal magnetic setting type with O/L, S/C protection including all fixing accessories with both ends spreader links -02 Nos (Make : Legrand/Schneider/L&T). (b) MCCB of IP 66/67 protection, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 63 Amps, adjustable magnetic setting (from 3.5 to 10 In), thermal release range ( 64 to 100 %) with O/L, S/C protection including all fixing accessories with both ends spreader links -01 Nos (Make : Legrand/Schneider/L&T). (c) MCB SPN 32 Amps 240 volts 'C' curve = 03 Nos Make :- AE/L&T (d) Spare Pockets for MCCB - 01 No
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 120 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this BOQ).
All as per ser item No 13 above but of cross sectional area 70 sqmm 3.50 core
All as per ser item No 13 above but of cross sectional area 50 sqmm 3.5 core
All as per ser item No 13 above but of cross sectional area 35 sqmm 3.5 core
All as per ser item No 13 above but of cross sectional area 25 sqmm 4 core
All as per ser item No 13 above but of cross sectional area 16 sqmm 4 core
All as per ser item No 13 above but of cross sectional area 10 sqmm 2 core
M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm dia GI suspension wire of wire 10 Sqmm 2 core,complete all as specified and directed .
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 70 to 120 sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 25 to 50 sqmm sqmm 3.5 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 10 to 16 sqmm 4 core cable complete all as specified and as directed Make : Raychem / 3M / Denson.
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 400 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 200-250 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T.
Supply and fixing MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 36 KA breaking capacity of rating 100-160 Amps including all fixing accessories with both ends spreader links and disconnecting and taking out old U/S MCCB complete all as directed. Make -Simence / Legrand / L&T. NOTE FOR ITEM NO- 30 TO 32 :- MCCB shall be replaced as per existing frame size/ Model and as per requirement of site.
Supply and fixing in repair for switch disconnector fuse unit in sheet steel enclosure TPN current rating 125 Amp with HRC Fuse including disconnecting and taking out unserviceable one complete all as directed. Make - L&T / Havells / HPL .
Supply and fixing in repair for in changeover switch disconnector open execution type 4 pole 415 volts AC of current rating 400 Amps including disconnecting and taking out unserviceable one complete all as directed. Make - L&T/ Havells / HPL .
Supply and fixing in repair for in changeover switch disconnector open execution type 4 pole 415 volts AC of current rating 250 Amps including disconnecting and taking out unserviceable one complete all as directed. Make - L&T/ Havells / HPL .
Repair / Servicing / maintenance of Battery Charger Panel to checking of all connection of internal power supply complete with replacement of old unserviceable parts as per required at site all as specified and directed by Engineer-in-charge.And after complete servicing results to be required: (a) Boost Voltage -upto 2.75 Volt/Cell (b) Output Current- 45 Amps(Max) (c) Float Mode-21 Amps (d) Boost Mode- (i) Starting Rate- 24 Amps (Max) upto 2.35 V/Cell (ii) Finishing Rate- 12 Amps (Max) upto 2.75 V/Cell (e) Output Voltage Reg.-within 10% (f) Mode of Operation- Automatic/Manual complete all as specified and as ditected by Engg-in-charge. Note: Servicing of 200 AH Capacity Lead Acid Cells of 17 Nos. Tubular type included in quoted rate.
M&L in repair prepration of old painted surfaces steel / Iron of any description over 10 cm in width or girth not otherwise described and two coats of synthetic enamel painting after one coating of red oxide primer in existing surface after proper cleaning complete all as specified and directed. (Note:- Painting of panels / feeder filler boxes shall be carried out in different colour of paints as required at site and as directed.)
M&L for preparation of new surfaces of steel/ iron sheet and panels surfaces of any description not otherwise described , over 10 cm in width or girth and applying one coat synthetic enamel paint over and including a coat of primer complete.
Material and labour LT Cable rout indicator made out of PCC Post of 1:2:4using 20mm gradedsone aggregate of size not less than 20 x 15 cm and one meter height with making embossing the following letters of size 100 mm in the PCC Post " LT CABLE with ARROW" including necessary excavation and PCC 1:2:4using 20mm gradedsone aggregateusing 20mm gradedsone aggregate (30CM X 30CM x 30 CM ) for embeding in the ground complete all as specified and directed.
M & L for Earthing to OH /Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES Schedule part-I 2009, GI earth lead wire protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion & earth work complete all as specified and directed.
RC GUPTA AND SONS
MS SHANTI AND SONS
PAPPU ROY CONSTRUCTION
M/s KUMAR ENTERPRISES
M/S Harsh Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .