Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.6 L+₹80,555.70 (4.79%)Rejected-Finance C O S 1 ESS GEE COMPLEX NEAR J K BANK SONAWAR BAZAR B B CANTT SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹17.7 L+₹87,000.10 (5.17%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance Being L3 |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
11 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, 134 Works Engrs
HQ 134 Works Engrs, PIN-914134, C/o 56 APO
SPECIAL REPAIR / REPLACEMENT OF BER EQUIPMENT AND LT DISTRIBUTION SYSTEM AT SHAR-E-SHALI GARRISON UNDER GE 861 EWS.
2020_MES_395173_1
134 WE-60/2020-21
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please see tender documents
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹37,000
Yes
16 Feb 2021
13 Nov 2020
14 Dec 2020
13 Nov 2020
11 Dec 2020
28 Nov 2020
60 days
Amount
M&L earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5Mtr length, burried directly and preferably vertically in ground with top edge not less than 1.25 Mtr below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in plate No 2 to the earthing test point including earth continuity conductor drawn in conduit/pipe or fixed to poles of size 4mm dia galvanised iron or steel wire testing on completion complete all as specified and directed by engr-in-charge.
Stay assembly using 20mm dia MS stay rod and stay plate of size 300x300x6mm thick, stay bow, loop insulator 90x140 mm made of porcelain vitreous and galvanised stay strand of size 7/4mm suitable for 11m pole, nuts, bolts and check nuts of GI shackle and clamp etc all as shown in Electrical Plate No 01 of SSR Part-I of 2009 including taking down existing unservicable stay assembly, etc complete all as specified and directed. (Note : Excavation/earthwork and PCC in fdn shall be measured and paid separately.)
S&F (in repair) Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws (as per IS-2713 part 1 to 3 1980 figure 3 & 4 )as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out, plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer and marking of pole number with black paint in yellow circle and taking down old UNSV pole complete all as specified and directed by Engr-in-Charge. Note: The rates also include for shifting of conductor and insulator etc from old pole to new pole.
Replacemnt street light 25W LED type energy saving and environemenal friendly long life versatile pressure die cast aluminium fittings including necessary brackets, clamps etc and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge. Make Bajaj CAT PAT No BCLST25W LED1 or its equivalent in Philips/ Surya.
Dismantling of ACSR or AAC conductors complete all as specified and directed by Engr-in-Charge.
Supply and fixing LT overhead lines on existing poles with XPLE insulated AB cable 3 Core 35 Sqmm Phase +1 Core x 25 Sqmm Neutral +1 core x 25 Sqmm messenger cores including identification of phase by Ridge provided on the insulation of phase conductors 1 ridge of the 1st phase, 2 Ridges for the 2nd phase and 3 ridges for the 3rd Phase and 4 Ridges for Neutral, No RIdges for messanger, including accessories like Anchor Clamp, Suspension Clamp, Line connector, service clamp, insulation piercing connectors (IPC) for Tap from bare lines) dead end, Suspension clamp, 1 hook etc complete all as specified and directed by Engr-in-Charge.
Supply, laying, connecting and testing 1100 volt graded heavy duty XLPE cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 35 Sqmm nominal cross section 4 core including suitable size lugs laid in trenches fixed to pole or passing through pipes including all necessary clamps nuts, bolts and washers etc and taking down old and UNSV cable, complete all as specified and directed by Engineer-in-Charge .
Excavation in trenches for soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundatoin of poles/ stay/ cables etc including getting out in soft/loose of soil for taking up or laying of cables complete all as specified and directed by Engr-in-Charge.
Excavation in trenches beyond 1.5 metre wide and not exceeding 3 metre deep for foundatoin of poles/ stay/ cables etc including getting out in soft/loose of soil for taking up or laying of cables complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.5m above the starting point , complete all as specified and directed.
Sand cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured.
Brick well burnt locally available sub class "B" laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable all as directed.
PCC, M-7.5 (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete for poles complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete, M-15(1:2:4), type B-1( using 20mm graded crushed stone aggregates) as in coping, benching and the like upto 60cm in height, including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling & mass concrete for stay complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mesh and medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Notes:- (i) Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shall deem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion if desired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department.
Supply, installation,testing and commissioning silent diesel engine driven generating set developing BHP air cooled of capacity 40 KVA (32 KW), 415 volts, 0.8 power factor alongwith inbuilt AMF control panel, mounted on common base frame coupled, 1500 RPM along with sound proof enclosure (acoustic enclosure) design for reducing the sound level to 75dB (A) IS 10001/1002 part 10 as per approved CPCB norms and as per GSR 371 (E) dated 17.5.2002 with silencer pipe and silencer muffler covered with asbestos rope 25 mm thick indepedently supported from engine to outside of pump house up to 1.0 mtr cold start kit, battery start with suitable size of standard cable for connection from DG set to panel board, DG set shall be capable of operating in temperature range of (-) 20 to (+) 40 deg C with Including foudation of DG set as per manifacturer size and specification) and including the following :-
(A) Prime Mover Vertical diesel engine of suitable capacity 40KVA at NTP, air cooled type closed (Radiator Mounted), circuit as per BS-5514 or ISO-3046, direct injection type turbo Charged , battery starting system having rated speed 1500 RPM. The DG set shall be capable of running 24 hours continuously with 10% over loading for one hour in every 12 hours run as per BS- 5514/BS-649. Engine shall be equipped with all standard fittings as per manufacture’s recommendation & mounted common plate through flexible coupling with following fitting: - (i) RPM cum hour meter (ii) Battery charging ammeter. (iii) Ignition key and starting with button switch. (iv) Lubricating oil pressure gauge. (v) Mechanical / electric governor controlling. (vi) Toggle witch for idle running (vii) Oil temperature gauge (viii) Safety control with tripping facility for the following (a) Low lubricant oil pressure (b) Over speed (c ) High water temprature (ix) Starting equipment comprising of following:- (a) Battery as per manufacturer recommended Make :- Exide/Luminus/Amron. (b) Battery, charging alternator with inbuilt regulator. (c) Battery leads of copper cable of suitable size brass thimbles and terminals. (d) Self starter motor assy of suitable capacity (e) Cold Starting kit Make of engine – Kirloskar oil engine/ Mahindra and Mahindra/ Tata Ruston/ Cotton Greaves
(B) Alternator: - Alternators rating 40 KVA, 3 phase, 50 cycle, 415 Volts, 4 wire supply at NTP 0.8 power factor running @ 1500 RPM self excited, self regulated, mounted on strong steel fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. The alternator shall be conforming to BS-5514 or IS-4700, ISO - 3046. Make of alternator :- Kirloskar electric, Cummins electric/ Stamford/ Jyoti/ Bharat Bijlee
(C) AMF Control Panel: As per company design
(D) Other fitting :- (i) Battery Charger- Battery charges having electric circuit consisting of triodes, rectifies, capacitor and resistance etc. The battery charges should be able to charge the battery at all the time whenever electric supply given to battery charges through control panel or electric power point. (ii) Fuel tank made up of MS Sheet of suitable capacity as per manufacturer’s instructions capable to store fuel for 12 hours running of DG set fixed as per manufacturer`s design and return fuel pipe with all pipes connecting upto fuel pump including oil level indicating gauge, drain plug for cleaning and air vent plug etc. (iii) Cold Starting kit (iv) Power factor meter - 01 No (v) MCCB 4 Pole 63 Amps - 01 No for incoming (vi) Battery 12V 180 AH, Battery leads (vii) First fill of lubricating oil (e) Display Parameters : Phase voltage, line current, frequency, average voltage, average curent KW, KWH, KVA, KVAR, Power factor. (f) Mechanical Protections : Lube oil pressure, coolant temperature (for liquid cooled engines), cylinder head temperature (for oil cooled engines), Engine speed, Fuel status, Engine run hours, Battery voltage. (g) Protection :- (i) Electrical Protection : Under/over voltage, under/over frequency, phase failure or phase erase over current, over KW. (ii) Mechanical Protection : Under/over speed, low lube oil pressure, high engine coolent temperature (for liquid cooled Engines), Belt failure (for air cooled enignes) low fuel level alarm. Note : DG set shall be supplied alongwith original acoustic enclosure of the manufacturers suitable for 40 KVA set as per CPCB Norms. (ii) Pre and post commissioning test of DG set shall be carried out by the rep of Accepting Officer within overall cost quoted. (iii) Foundation of DG set shall be included in overall cost quoted.
M/S A.N CONSTRUCTIONs
FG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .