Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC 3 NO NIMUSI H NO 22 P O SIMALUGURI P S DHALPUR DIST LAKHIMPUR PIN 784165 | SIMALUGURI | LAKHIMPUR | ASSAM | 784165 | ₹2.2 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | Rejected-Technical CHEGELI POTHER P O JIADHAL CHARIALI P S DHEMAJI DIST DHEMAJI ASSAM | DHEMAJI | ASSAM | 787026 | - | - | Rejected-Technical Non Responsive |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
8 Jan 2021, 2:00 pmClosed
The Chief Engineer, PWRD (EAP), Assam
O/o The Chief Engineer, PWRD (EAP), Assam, Fatasil Ambari, Guwahati-781025
Market Modernization and Improvement Program (MMIP) of Simaluguri Market in Lakhimpur District under APART
2020_PWD_19577_6
CE/APART/79/2020/14
Open Tender
Civil Works - Building
Lump-sum
360 days
Lakhimpur District
Please refer Tender Documents
7 documents required · 7 mandatory
₹5,000
State Project Director, ARIAS Society
₹5.0 L
O/o The Chief Engineer, PWRD (EAP), Assam
25 Mar 2021
9 Dec 2020
8 Jan 2021
9 Dec 2020
8 Jan 2021
9 Dec 2020
9 Dec 2020 - 22 Dec 2020
22 Dec 2020
Amount
CIVIL WORKS Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinary soil
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified. (b) Other than Guwahati city
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1cement: 3sand :6coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M20 grade concrete or Prop. 1:1.5:3.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (B) In super structure above plinth level upto first floor. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. M20 grade concrete or Prop. 1:1.5:3.
Clearing and grubbing road land including uprooting wild vegetation,grass, bushes, shrubs, saplings and trees of girth upto 300 mm,removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By Manual Means (A) In area of non thorny jungle
(A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
WBM Grading II Using stone screening Type-B 11.2 mm for Gr.II Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. (A) By Manual Means
WBM Grading III Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Inter locking concrete Block pavement (A) Interlocking pavement block (i) Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage. (a) Including Edge block/ Edge restraints
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (B) In super structure above plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. M20 grade concrete or Prop. 1:1.5:3
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut. Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. Floors etc. upto 200mm in thickness. Using 25mm thick plank
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL TMT Corrosion resistant steel (CRS) reiforcement bar
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL. Super Ductile (SD) TMT reinforcement bars
Providing brick soling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and panel after preparing the sub-grade as directed including all labour and materials and if necessary dewatering, complete. Brick on flat soling.
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure. In superstructure above plinth level up to floor level. In proportion 1:4.(1 cement:4 sand)
230mm thick brick wall in cement morter with 1st class brick including racking out joints and curing complete as directed in structure. In superstructure above plinth level up to floor level. In proportion 1:3.(1 cement:3 sand)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary. In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 112mm thick brick wall. In cement mortar in proportion 1:4. (1 cement:4 sand)
65mm thick cement concrete floor consisting of 50mm under layer of cement concrete in prop. 1:3:6 (1 cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1 cement : 1 coarse sand : 2 coarse aggregate of 10mm down) laid in panels & finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg per square metre of floor area) including curing etc. complete as directed
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make Of size 600mmx600mm and above
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). Of size300mmx600mm and above
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor. 20 mm thick
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Rough Side In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Fair Side In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On rough side (backing coat 15 mm and finishing coat 5mm thick). In Cement Mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. On Fair side (backing coat 15 mm and finishing coat 5mm thick). In Cement Mortar 1:4
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior paint of approved brand of required shade, thining by adding water as per the specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered material as specified and directed by the department. Unicem Rakshak
Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.
Extra over item no. (b) and (c) above for every subsequent coat of water proofing cement paint of approved brand and manufactured.
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand manufacture (Asian Paint/ Berger Paint/ ICI Paint/ J&N Paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. Surfaces over 100 mm in width or girth. General purpose (Asian Paint/ Berger Paint/ ICI Paint/ J&N Paint/ Nerolac).
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter, sand papering and knotting. With ready mixed paint, wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.Surfaces over 100mm in width or girth. General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. Finally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid. Standard Ceilings of Everest make or equivalent as directed by the departement. Using 6 mm thick FC Board
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S bars with round headed bolts and nuts or screws. Plain grill Fixed to Brickwork/PCC/RCC
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement 0.50 mm thick.
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement 0.50 mm thick.
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. With 1st class timber (Bonsum/ Sundi)
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) 39mm Thick
Providing, fitting and fixing anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels. (Cement concrete to be measured and paid separately). Side hung and Top hung windows and ventilators 5 mm clear glass
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished). Door handles 150mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) Tower bolts 150mm x 10mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) Butt hinge 50mm x 35mm x 3.2mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) Mortice lock vertical type 100mm(Godrej with handle (6 lever)
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. 75mm thick slab
ELECTRICAL WORKS Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete as directed and specified by the Deptt. Short point up to 3.00 metre. length.
Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department. SYSTEM SPECIFICATION a. 7 W LED based luminaries/fixture (770 Lumen -typical.) b. LED Type: White High Powered LED’s 5500-6500 K temperature. c. Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System. d. Powered by a 12V, 35 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215 e. Certification. (Model: TBP 1235/ 1235M). (make: TATA BP SOLAR or equivalent) f. 12V, 40Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery. (make: TATA BP SOLAR or equivalent). Battery Box made of M.S fabricated with corrosion resistance paint. 4 m height MS Pole with corrosion resistance paint. Autonomy 5 Days. SUGGESTED UNIT PRICE Unit Cost Without Installation & Commissioning)
Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department. SYSTEM SPECIFICATION a. 7 W LED based luminaries/fixture (770 Lumen -typical.) b. LED Type: White High Powered LED’s 5500-6500 K temperature. c. Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System. d. Powered by a 12V, 35 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215 e. Certification. (Model: TBP 1235/ 1235M). (make: TATA BP SOLAR or equivalent) f. 12V, 40Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery. (make: TATA BP SOLAR or equivalent). Battery Box made of M.S fabricated with corrosion resistance paint. 4 m height MS Pole with corrosion resistance paint. Autonomy 5 Days. SUGGESTED UNIT PRICE Installation & Commissioning Charges
Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete as directed and specified by the Deptt. Medium point up to 6.00 metre. Length.
Wiring for light/ fan/ call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/ Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover, ceiling rose etc. complete as directed and specified by the Deptt. Medium point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq.mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537. Part - III conduit.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point up to 3.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point up to 3.00 metre. Length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) wiring system. With 3 x 10 sq. mm. + earth continuity with2x 6 sq. mm. cable in 25 mm. dia. rigid Steel conduit.
Supplying including and fixing of following Moulded PVC boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface system complete as per direction of department. 12 module horizontal surface Moulded PVC boxes
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial flexible cable conforming to IS-694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) wiring system. With 3 x 6 sq. mm. + earth continuity with2x 4 sq. mm. cable in 25 mm. dia. rigid Steel conduit.
Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 12-16 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 8 Module
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 16 Module
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. D Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. D Series (Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. D Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting fixing of T 5 luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection cable, as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. BATTEN LIGHT, MIROLTA SLIM T 5 TMS 540 with 1x28 W T-5 Fluorescent tube. (Philips make or equivalent)
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 6-8 module type Metal
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make)
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Ventilator DX 200 mm sweep Louver type (ORIENT make), Brisk Air 200 mm sweep Louver type (Crompton make)
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. Modular Motor Starter switch Relay Range 16 - 25 Amps in 3 Module
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make). 6 way SPN single door .
SANITARY WORKS Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 450 mm White Jaquar make
Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) White Sahara walvit Pan set (inclusive of seat cover and fittings) (white) (Cat. No. C0261)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware Make White Aquaseal (Cat. No.C0508)
Providing fitting and fixing vitreous china squatting plate urinal with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware Make White (Cat. No. C0503)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 75mm dia
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm dia
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm dia
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm X 110mm
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm X 75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 110mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 75mm dia
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. 110mm dia
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved uP.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches 32 mm dia
Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved uP.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches 25 mm dia
Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all plain and cpvc brass threaded fittings i/c fixing the pipe with claimps at 1.00 m spacing. This is includes jointing of pipes. Concealed pipe with cutting chases & making good the walls. 20 mm nominal outer dia pipe
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately). Jaquar Make 2-Way Bib Cock
Supplying fitting and fixing polymer bib cock (15mm dia) of Polymer Prayag make directed and specified.(G.I. & C.P pipes will be measured and paid separately) (c) Long body with flange
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately). Jaquar Make 15mm dia( Angular stop cock with long thread)
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. Jaquar Make Long neck with areator
Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified.(G.I. & C.P pipes will be measured and paid separately). Jaquar brand. Continental / Clarion Flush cock with wall flange 25mm with lever knob
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 40mm dia
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. CPVC pipe with CPVC fittings (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe). 40mm (OD) dia
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. PVC PIPE SUPREME /PRINCE / FUSION /SFMC Brand. 75mm dia
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches. 110mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or trenches. 110mm x75mm.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 75mm dia. PVC cowel of ISI make
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately). Wall Hang Basin Jaquar Make Cat. No.CNS-WHT-WB04 (550 x 400 x 198)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately). Table Top Basin Jaquar Make Opal (Cat. No.OPS-WHT-0556)
Providing fitting and fixing Decorative Mirror complete as directed and specified. Parryware Make Size 600mm x 450mm
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. Jaquar Make Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing CP towel rail complete as directed and specified. Jaquar Make Queen's - Grab bar (300mm long) (Cat.No.AQN-7711B)
Providing, fitting and fixing Chrome Plated Toilet Paper holder complete as directed and specified. Jaquar Make Kubix Spare roll holder (Cat. No. AKB-35755)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. Jaquar Make 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. Jaquar Make. Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. Parryware Make White Partion Magnum / Large (Cat. No.C0571/07)
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed. uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe) 110mm diameter
EXTERNAL WORKS: Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes 2000 litre capacity Sintex Make
Labour for erecting and placing PCVC Tank over the stagging up to a height of 5.00m complete as directed. 2000 litre capacity
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. Bore hole of 100mm diameter
Supplying, fitting and fixing lift and force Maya hand pump of approved with all accessories complete as directed by the Department..
A provisional sum of Rs 5,00,000.00 (Rupees Five Lakhs Only) to be quoted by the bidder in the Basic Rate coloumn without changing the value of Rs 5,00,000 for unknown items of resettlement of existing temporary market sheds and EMP requirements beyond the provison of SOR is provided which shall be operated and expended in whole or in part at the instruction of Enginner-in-Charge
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .