Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC AT 381 341 SARITA APARTMENT P O KHARAGPUR KHARIDA MAIN ROAD MIDNAPORE WEST WEST BENGAL 721301 | MEDINIPUR WEST | WEST BENGAL | 721301 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹36.9 L+₹6.5 L (21.3%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹37.3 L+₹6.8 L (22.4%)Rejected-Finance 30 SHIVTALLA STREET KOLKATA 700 007 | KOLKATA | KOLKATA | WEST BENGAL | 700007 | L3 | Rejected-Finance Being not L1 | |
| 4 | l4₹41.2 L+₹10.7 L (35.2%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | l4 | Rejected-Finance Being not L1 |
Tender Value
₹43.4 L
EMD Value
₹86,800
Closing Date
25 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR M K YADAV
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
ADDITION ALTERATION OF WORK SERVICES FOR PROVISION OF POWER SUPPLY FLAME PROOF FITTINGS AND ALLIED WORK IN VARIOUS TECHNICAL BUILDING AT AF STATION KALAIKUNDA UNDER GE AF KALAIKUNDA
2024_MES_651500_1
8011/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹86,800
Yes
29 Jun 2024
29 Apr 2024
27 May 2024
29 Apr 2024
25 May 2024
13 May 2024
Amount
Supply and fixing for surface type sub main wiring with two run of 2.50 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid stove enamelled steel conduit ISI marked of size 20mm bore with all fittings like Tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 20 mm including one run of 2.50 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 2.50 sq mm and one run earth wire 2.50 sqmm and one run of Rigid stove enamelled steel conduit with all fittings will be measured as one unit length.
Supply and fixing for surface type sub main wiring with four run of 10.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid stove enamelled steel conduit ISI marked of size 25mm bore with all fittings like Tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. of nominal size 20 mm including one run of 10.00 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 10.00 sq mm and one run earth wire 10.00 sqmm and one run of Rigid stove enamelled steel conduit with all fittings will be measured as one unit length.
Supply & fixing Flame proof weather proof rotary switch, certified by CIMFR protection type Ex- ‘d’ , Zone 1 gas group IIC, IP 65. with cable termination box in High Pressure Die Cast Aluminum Alloy LM6 housing single Pole 16 Amp, 240 volts complete as specified.
Supply & fixing flame proof weather proof metallic hose conduit 3/4 " dia , M20 /3/4" conduit MxM / FM x M / Fx F 3/4 " dia 300 mm long, certified by CIMFR protection type Ex- ‘d’ , Zone 1 gas group IIB, IP 65. incl all as specified including taking down the existing one.
Supply & fixing flame proof weather proof metallic hose conduit 3/4 " dia , M20 /3/4" conduit MxM / FM x M / Fx F 3/4 " dia 500 mm long, certified by CIMFR protection type Ex- ‘d’ , Zone 1 gas group IIB, IP 65. incl all as specified including taking down the existing one.
Supply & fixing flame proof, weather proof Plug in switch socket 32 A, 5 Pin (4P+E), certified by CIMFR protection type Ex- ‘d’ , Zone 1 gas group IIC, IP 65 complete all as specified.
Supply & fixing Flame proof weather proof Distribution board , TPN, 04 Way, 415 Volt, prewired, certified by CIMFR protection type Ex- ‘d’ , Zone 1 gas group IIC, IP 66 with and including MCB`s with following specifications complete all as specified . (a) Incomming: MCB, 4 Pole, TPN, 63 Amp, 10kA, "C" Curve - 01 No. (b) Out going : MCB SP 6-32 Amp, 10kA, "C" Curve - 12 Nos.
Supply & fixing CIMFR certified LED flame proof, weather proof Flood light 120 watt LED having protection type Ex- ‘d’ , Zone 1 gas group IIC, IP 66, Temparature class T5-T6 complete including connecting with PVC insulated multi stranded copper flexible cable 1.5 sqmm three core complete all as specified and as directed.
Supply & fixing in repair LED flood light 170 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 110 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as per latest IS. LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 18700 protection grade IP 66, IK-08 CRI greater than or equal to 70% , CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wire of 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified. Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However, as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account.
Supply and fixing for circuit/sub main wiring with two run of 2.50 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through non metalic PVC rigid conduit medium grade of suitable size and conduit accessories to be fixed on street light pole with and including 03 set of GI clamp, nut & bolts ncluding one run of 2.50 Sqmm single core PVC FRLSH, PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 2.50 sq mm and one run earth wire 2.50 sqmm and one run of non metalic PVC rigid conduit medium grade of suitable size with all fixing accessories will be measured as one unit length.
Supply and fixing factory made wall mounted 200 App rated Busbar chamber, 6 way, 4 pole 415 volt, conforming to IEC-60439 and IEC-60529, fabricated from 2.00 mm thick CRCA sheet, epoxy powder coated ETP grade copper & dull tin plated bus bar sections supported on DMC (Dough moulding compound), fully rated neutral bus bar. IP-31 complete all as specified.
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)
Supply and laying fly ash best quality, laid in trenches, perpandicular to U/G cable for cable protection complete all as specified.
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 95 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 3.5 core 70 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4 core 25 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 4 core 16 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
M & L for Boring of horizontal hole under road, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine with and including GI Pipe light grade of dia 100 with all fittings, for passing of cable complete all as specified. Note : (i) One run of boring of horizontal hole and one run of GI Pipe light grade of dia 100 with all fittings will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate.
M&L for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 22, 8.5 metres long including two coats of aluminium paint over a coat of red oxide primer after preparation of surfaces complete all as specified.
Supply and fixing loop in- loop out fuse junction box of internal dimention 254 x 180 x 90 mm made of thermoplastic sheet with weather proof canopy and locking screw fitted with and including 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing, including provision of MCB SP 6 to 32 Amp rated mounted in the box, fixing on street pole/rail poles including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including all as specified and directed.
M&L for cement concrete ( 1:4:8) type D-2 using 40mm graded crushed stone aggregate as in pole foundation, filling and mass concrete complete all as specified
M&L for cement concrete ( 1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of pole including weathering, slightly rounded or chamfered angles and throating, necessary formwork as directed complete all as specified
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm dia as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel upto 7.5m length, earth strip protected by and including 20 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. (4.00 mm dia GI Wire including protection pipe upto 7.5 RM will be included in the item rate and 4.00 mm dia GI Wire beyond 7.5 RM will be measured seperately).
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI strip 25 x 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel upto 7.5m length, earth strip protected by and including 40 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. (GI strip 25 x 4 mm including protection pipe upto 7.5 RM will be included in the item rate and 4.00 mm dia GI Strip beyond 7.5 RM will be measured seperately).
Supply,designing ,install, testing & commission 3 phase and neutral, 415 volts outdoor type, CPRI type tested having certification of IEC-61439 , factory made , dust and vermin proof, cubical type LT panel of size 1.50m x 1.50m x 0.75m, with canopy fabricated from 3.00 mm thick CRCA sheet for outer shell and 2 mm thick for non load bearing with angle iron frame of 50 x 50 x 6 mm, double door, front and back openable type, double door system, hinged opening, rubber lining, locking arrangement, with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade, protection class IP-66 fully compartmentalize design with 4 Nos of bus bar rated 375 Amps made of copper ETP grade pre-wired with suitable size of copper strip/copper wire with colour code for connecting out going MCCB/MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring for street light auto ON/OFF control timer by using desired electrical parameters PCC foundation and pedestal for fixing pillar feeder box/LT Panel with PCC 1:3:6, 15 cm thick in foundation, brick (Fly ash) / PCC block work in CM 1:6, rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grounting bolts etc for panel. The platform shall be of 450 mm height above ground level all as specified with supply and fixing the following accessories as mentioned in BOQ Srl No :
SUMAN CONSTRUCTION
SUDHA ENTERPRISES
M/s Tekcon International
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .