Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹33.3 L+₹2.9 L (9.47%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted |
| Sl No | Description | Qty | Unit | A B K Enterprises L1 | sheetal engineering L2 |
|---|---|---|---|---|---|
| 1.00 | Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 500 KVA,capacity Make : Cummins ( including the cost of the following spares all as per OEM instructions and directed by Engineer in Charge. (Note:- contracter should submit MOU of OEM cummins with authorised service engineer&Necessary test report shall be submitted) | 1 | Each Job | 18,000 ₹18,000 Lowest | 39,999 ₹39,999 |
| 2.00(a) S & F in repair lubrication oil filter | |||||
| 3.00(b) S & F in repair by pass filter | |||||
| 4.00(c ) Checking of hydraulic governer | |||||
| 5.00(d) Checking and toping up of coolant | |||||
| 6.00(e) S & F in repair fuel filter. | |||||
| 7.00(f) S & F in repair air cleaner element . | |||||
| 8.00(g) Cleaning radiator complete set | |||||
| 9.00(h) Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction | |||||
| 10.00 | All as per item No.1 (a) to (h) here in before but for up to below 250 KVA DG set Make Cummins complete all as specified | 1 | Each Job | 12,000 ₹12,000 Lowest | 25,000 ₹25,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Jul 2025, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
MAINT AND REPAIR TO DG SET EXTERNAL WATER SUPPLY SUBMERSIBLE PUMPS BOOSTER PUMPS SETS REPLACING OF OLD U/S DI/GI TUBING GATE VALVES SLUICE VALVE AND PERIODICAL MAINT AND SERVICING OFT ACS AND REPLACEMENT OF LT UG CABLE LT PANEL SECURTIY LIGHT AND C
2025_MES_716776_1
GE/GUR-/NIT-33/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹90,000
12 Sept 2025
25 Jun 2025
25 Jul 2025
25 Jun 2025
23 Jul 2025
9 Jul 2025
Amount
Carry out 'B' check from authorised rep or service engineer from the manufacturer of DG set of 500 KVA,capacity Make : Cummins ( including the cost of the following spares all as per OEM instructions and directed by Engineer in Charge. (Note:- contracter should submit MOU of OEM cummins with authorised service engineer&Necessary test report shall be submitted)
(a) S & F in repair lubrication oil filter
(b) S & F in repair by pass filter
(c ) Checking of hydraulic governer
(d) Checking and toping up of coolant
(e) S & F in repair fuel filter.
(f) S & F in repair air cleaner element .
(g) Cleaning radiator complete set
(h) Engine Oil as per manufacturer specification and any other checking as per manufacturer instruction
All as per item No.1 (a) to (h) here in before but for up to below 250 KVA DG set Make Cummins complete all as specified
All as per item No.1 (a) to (h) here in before but for up to below up to 380/400 KVA DG set Make cummins complete all as specified
Supply and fixing in replacement of AVR S/F VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set upto 500KVA complete all as specified and directed by Engineer -in-charge.
Disconnected and opening of self starter assembly 12/24 volt up to 500 KVA Capacity DG set taking out unserveceable part of self starter and supply and fixing in replacement of self suitable size as required on site complete all as specified and directed.(Note:- Rate are deemed tobe include all wom out part including gear & winding complete all as specified)
Dismantling of radiator fan engine of following capacity, cleaning and chocked tubes after draining out water, washing with caustic, descaling and brazing for water leakage etc. and refixing the same properly complete all as specified & directed :
a) up to 500 KVA
Supply only the following items of DG Set of various capacity :-
(a) Battery terminal, lug, bolts type suitable for heavy duty battery.
(b) Battery leads for copper conductor multiwired 70 Sqmm. Single Core of 1.5 Mtr length
(c) Hinges for DG set door of any size, any type as required on site.
Dismantling existing U/S battery charger & S/F of SMPS type battery charger suitable for 12 V DC with auto cut off from trickle to boost alongwith AC lead to charge the battery when DG Set is not in use complete all as specified & directed by Engineer Incharge.
Supply only coolant suitable for generator set diesal engine driven of best quality ISI marked complete all as specified and directed
Supply and filling Low viscosity synthetic Engine oil 20W40 of the specified grade as per OEM
S&F V belt for fan pulley (set of 2Nos) for DG set upto 500 KVA DG Set complete all as specified.
S&F V belt for alternator and water pump assembly for DG set upto 500 KVA complete all as specified.
S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 500 KVA, complete all as specified.
S&F Fuel pipe from fuel tank to fuel filter for DG set upto 500 KVA, complete all as specified.
Supply and fixing of 'under/over voltage relay, 3 phase, 415 volts', for DG sets of capacity upto 500 KVA complete all as specified and directed by engineer-in-charge.
Supply and fixing of battery voltage relay 12V DC complete all as specified and directed.
Supply and fixing of Fuse (HRC type) for DG sets of capacity up to 500 KVA complete all as specified and directed.
Supply and fixing in replacement of Lead acid maintenance free Battery 12 Volts 180AH of existing type & size suitable for DG Sets .
Supply and fixing in replecement of 63 to 160 Amp, 415 Volts, 50 Hz Power contactor MNX type of coil voltage 240 Volts, complete all as specified and directed.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 250 KVA to 500 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth operation complete all as directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set connection testing complete all as specified and directed.
Material & labour for complete overhauling,servicing of turbo charger, opening /taking out of turbo charger of DG set of 250 KVA to 500 KVA capacity ,disconnection of air supply connection pipe etc, including replacement of turbo charger repair kit, calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the allignment, making proper all connection, testing for smooth operation from authorised rep or service engineer from the manufacturer complete all as directed.
Attending leakage complaints of sluice valves by opening removing gland plate and pumping/taking water from water pit and proving gland packing and refitting by replacing worn out bolts,nuts and washers complete all as specified. Note: bolts,nuts and washers will be paid under relevant items of schedule
M& L for complete dewatering and cleaning of underground sump of capacity 50K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable all as directed by Engineer -in- Charge.
M& L for complete dewatering and cleaning of underground sump of capacity 10K gallons with high pressure jet to remove all masses ,algae and dirt and removal of dirty water along with sludge using sludge machine and disposal of same to a safe distance and including scrubbing of internal surface using industrial vacuum machine and applying of anti-bacterial sterilization spray and apply one coat white wash to wall , floor and ceiling , internal surface of reservoir where applicable all as directed by Engineer -in- Charge.
comprehensive maintenance & repair of Hydropneumatic system (Make: Grund Fos) checking of motor, Well Vent Air Release Valve vertical turbain Pump, Water Meter ,ASME Pressure Relief valve Including Replacement of air water control unit Complete all as specified & directed by Engr-in-charge
Supply only calcium based white to off white free flowing solid granuals chemicals having chlorine content of minimum 60% for chlorination in 45 kg packing complete all as specified and directed. Make:-As approved by GE.
Taking the water sample for semi under ground sump and submitted the sample of water to the Govt lab for testing of water Qutarly ,Chlorine test and all chemical componants test complete all as specified and as directed
Supply laying, testing CPVC pipe (SRD 11) line 20 mm dia bore with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing CPVC pipe (SRD 11) line 25 mm dia bore with all fittings laid in trenches complete all as specified and directed.
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insulated unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.
Supply and Fixing LED street light luminaire IP-66 grade,LED of 70 watt rating with unique peanut lens to ensure uniform distribution suitable for upto 50 mm dia GI Bracket complete all as specified and as directed . Make: CG or its equivalent in Wipro/Havells/Surya
Supply and fix in replacement of automatic timer switch panel mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Make : Kakatiya/Healer/Bajaj. Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
Carry out periodical maintenance & servicing (monthly) from authorised rep or service engineer from the manufacturer of blower of STP ( including the cost of replacement of Gear oil , Replacement of worn out helical Gear, worn out blower moter Fan & fan belt etc.) all as per OEM instructions and directed by Engineer in Charge .
Comprehensive maintenance for repair by periodical (monthly) checking of motor compresser system , valve , STP pipe line , filter system , pressure guage including air compressor complete coupling & leakage joint & repair / replacement of worn out parts of sewage treatment plant as existing complete all as specified and as directed. Note : i. technician should attend breakdown on as and when Required to rectified the defect urgently ii. Defective parts shall be measured & paid separetely
S&F in replacement of fan belt for compressor / flactuator motor any size & any type as per sample complete All as specified & directed by engr-in-charge
S&F in replacement of Butterfly / Ball Valve 50 mm nominal bore CPVC complete all as specified & directed by Engr-in-Charge
S&F in replacement of Sewage side flow meter as per sample for STP complete all as specified & directed by Engr-in-Charge
S&F in replacement of treated side flow meter as per sample for STP complete all as specified & directed by Engr-in-Charge
S&F in replacement of Dosing Pump as per sample complete all as specified & directed by Engr-in-Charge
S&F in replacement of pressure gauge / rotometer as per sample for STP complete all as specified & directed by Engr-in-Charge
S& F in repair blower as per sample for STP complete all as specified & directed by Engineer-in-charge
S&F in replacement of chemical injection pipe as per sample complete all as specified & directed by engr-in-charge
M&L for Repair , servicing & Maintenance of chemical injection pump with complete serviciable condition including replacement of worn out part complete all as specified & directed by Engr-in-charge
Supply only Nitrogenous frertiliser conten 46% nitrogen, Biuret % by weight Max 1.5%, in 50 Kg packets
Supply only diammonium phosphate phosphourus fertiliser containing nitrogen 18 %, phosphorus 46%in 50 kg packets
M&L for taking out / down pump / motor from base / chambber & opening of the motor up to 7.5 HP carefully & removing burnt winding from stator & rewinding with same gauge of super enamelled copper insulated wire & superior insulating material including warnishing , heating , greacing replacement of worn out bearring , reassembling the same including testing on full load up to entire satisfaction complete all as specified & directed by Engineer-in-charge
M&L for removing burnt windding from stator & rewinding with same gauge of supper enamelled copper wire & suppirior insulating material including varnishing , heating , greasing replacement of worn out bearing , reassembling the same including testing on full load for 3 HP press feed pump up to entire satisfaction complete All as specified & directed by Engr-in-charge
M&L for taking out & cleaning of BAR screen chamber / oil & grease trap / equalization tank / MBBR Tank / flocculator tank / tube satteler tank / chlorine contact tank / fillter feed tank / treated water tank , dewatering & digging out sludge , mud state & removing sluge to a distance exc. 250m & N exc 500 m & disposed of complete All as specified & directed by Engr-in-charge Note :- i. Rate are deemed include for transpotation & labour Charge from STP to low laying area complete All as specified & directed by Engr-in-charge ii. Cleaning of sluge shall be carried out 3 times of with interval of 3 months each cleaning shall be measured as each job
M&L for taking out & cleaning of sludge draing bed of STP any size digging out sludge , mud state & removing sludge to a distance exc. 250m & n exc 500 m & disposed of complete All as specified & directed by Engr-in-charge Note :- i. Rate are deemed include for transporation & labour Charge from STP to low laying area complete All as specified & directed by Engr-in-charge ii. Cleaning of sludge shall be carried out 3 times of with interval of 3 months each cleaning shall be measured as each job
S & F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,200Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Make Bajaj/ Surya/ Philips
S & F LED floodlight luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP66, Turbo LED series ,120 Watt & accessories and connecting up to looping box with PVC insulated multi stranded copper conductor cable 1.5 sqmm twin Core all as specified and directed. Make : Make Bajaj/ Surya/ Philips
S&F in Rep/Replacement of cable PVC insulated unarmored for connection 1.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in heavy duty rigid PVC conduit pipes complete all as specified and directed. MAKE- 1. Havells 2.Finolex 3.wipro
M&L for attending complaints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Indora, and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grease for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS AFS Indora, shall be carried out and report shall be submitted to Engr-in-chage with out any delay.
Supply and fixing battery 12 volts 85 AH ,ISI mark, make Exide complete all as specified and directed by Engineer -in-charge.
S&F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator withMS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed. Make- 1.Sintex 2.Universal 3.SMS
Supply, installing, testing and commissioning of maintenance free Chemical earthing system (Grid type, set of 03 earth) confirming to IS:3043 using copper pipe of size 3000 mm long, 1.6 mm thick and outer dia of pipe should be not less than 77 mm dia with exothermic "T" point rod with 7.5 mtr long copper strip of size 50 x 6 mm. with test certificate 99.99%. The ground enhancing compound made of Marconite conductive aggregate (consist of Marconite resin based cements, adhesive and gypsum plaster) shall not be less than 45 KGs, The electrode shall be provided on its top with an earth termination clamp made out of electrolytic grade copper for connecting earth continuity conductor with copper wire/ strip. PCC champer of size 300 x 300 x 300 mm with cover shall be privided on top of earth system on 100 mm thich PCC 1;3;6 bed concrete. The chamber shall burried in ground with top edge projecting upto 75 mm from ground surface complete all as sepcified and as directed. Note :- The earth resistance value should be less than 1.00 Ohm . (ii) The quoted rate shall include cost of copper strip 50 mm x 6 mm up to 7.5 Mtr length and earth pit bore hard /disintegrated rock. (iii) The contractor shall given a written guarantee for maintaning earth resistane of less than 1 ohm for a period of 5 Years from the date of complection. .
M& L in replacement for earth continuity conductor or main earthing lead fixed to wall/ceiling on batten or recess or chases or buried in ground or drawn in conduit/pipe or other directed situation for earthing etc as required 20x3 copper strip all as specified and directed.
S&F in replacement SMC/DMC insulator for seperation of earth strip from wall /ceiling including fixing accessories such as nut bolt etc complete all as specified and directed.
Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size 80 to 100 mm Bore of any description such as CI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed. Note :- Rates quoted shall be deemed to include the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule
Attending Complaints by deploying sufficeient labour for rectification of leakage of UG water pipe lines of size up to 50 mm Bore of any description such as CI/GI pipe line at any location including necessary excavation, earth work, dewatering, cutting existing pipe lines including repairs with suitable flanges, Joints or any other material complete all as specified and as directed. Note :- Rates quoted shall be deemed to include the cost of T&P required. Pipes and Jointing material shall be measured and paid under relevant items of schedule
Taking Out 100 mm dia DI water mains including all fittings complete all as specified and directed.
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 100 mm bore dia pipe complete all as specified and directed.
Taking out unserviceable rusted steel water tubing and connection including cleaning for refixing or removal from site all as directed of the following sizes:
(a) 20 mm bore
(b ) 25 mm bore
(c) 40 mm bore
(d) 50 mm bore
(e) 80 mm bore
Supply laying, testing GI tubing 20 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 25 mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 40mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 50mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply laying, testing GI tubing 80mm dia bore medium grade conforming to IS : 1239 with all fittings laid in trenches complete all as specified and directed.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 40mm dia bore complete all as specified and directed by Engr-in-Charge.
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 25mm dia bore complete all as specified and directed by Engr-in-Charge.
Taking down existing Ball cock and S&F in repairs of Ball cock complete with Rod and Ball ( low pressure and high pressure) with Epoxy coated Al Rod and HD Ball of size 20mm.
Taking down existing Ball cock and S&F in repairs Ball cock complete with Rod and Ball ( low pressure and high pressure) with Epoxy coated Al Rod and HD Ball of size 25mm.
Supply and fix in replacement cast iron flanged drilled heavy duty Non Retrun Sluice valve with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion nuts and bolts with washers etc of size 80 mm bore complete all as directed by Engr-in-Charge.
Lifting and taking out the submersible pump set and motor of capacity Upto 7.5 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sump /bore well and lowering back the pump after repairing from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete.
M&L for repairs & Servicing of defective submersible pump of capacity 7.5 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed . Note:- (a) The rates are inclusive of defective submersible pump transporting the pump from bore well site to repair work shop & back to site and refixing the same including testing. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts will be measured and paid separately under respective item of this schedule.
Supply and fix parts of submersible pump set of capacity 7.5 HP complete all as specified and as directed.
(i) Bearing bush Gun Metal
(ii) Bearing bush SS with rubber
(iii) Oil seal
(iv) Thrust plate/thrust bearing set
(v) Sand Guard
(vi) CI Thrust Casing
(vii) CI stage casing
(viii) GM Bush
(ix) Mild steel key for impeller
(x) SS Studs with nuts
(xi) CI Intermediate section
(xii) SS coupling bush common for pump & motor with key
(xiii) High Tensile steel shaft
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 7.5 HP complete all as specified and as directed .
M&L for rewinding of electric motor upto 15 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed
M&L for repairs & Servicing of defective vertical turbine pump (Booster Pump set) of capacity 15 HP by dismantling the pump & removing unserviceable parts , assemble the pump properly after replacements of unserviceable parts complete all as specified and as directed . Note:- (a) The rates are inclusive of dismantling of defective pump and motor from existig site, transporting the pump from existing site to repair work shop & back to site. (b) The rate are inclusive of turning / finishing work for fixing of parts properly. (c) The replacement of unserviceable parts such as Carban Seal, Water seal, gakets and other materials required for efficient running of pump set to be included in quoted rates only.
Demolition of existing valve pit chamber , M&L for masonry valve pit of size 900x900x900mm internal size complete with excavation, earth work and brick work in CM 1:6, 15mm thick plastering in CM 1:4 internally including 5mm thick MS Sheet cover and angle iron frame of suitable size and two coats of synthetic enamel paint over one coat of red oxide primer complete with locking arrangement complete all as specified and directed.
Supply and fixing GI Uninon 40 mm complete all as specified and directed.
Supply and fixing GI Uninon 50 mm complete all as specified and directed.
Supply and fixing GI Uninon 80 mm complete all as specified and directed.
Supply and fixing GI Socket 40 mm complete all as specified and directed.
Supply and fixing GI Socket 50 mm complete all as specified and directed.
Supply and fixing GI Socket 80 mm complete all as specified and directed.
Supply and fixing GI Socket 40 mm complete all as specified and directed.
Supply and fixing GI Socket 50 mm complete all as specified and directed.
Supply and fixing GI Socket 80 mm complete all as specified and directed.
Supply and fix DOL starter in sheet steel enclosure, A/C 3 phase,415v, type MK1, suitable for upto 10 HP submersible, 3 Phase motor all as specified directed to the entire satisfaction of dept.
Supply , laying & testing in repair for XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 16 Sqmm nominal cross section x 2 core complete all as specified and directed
All as per item No 123 described here-in-before but Size 25 Sqmm X 3.5 core
All as per item No 123 described here-in-before but Size 35 Sqmm X 3.5 core
All as per item No 123 described here-in-before but Size 95 Sqmm X 3.5 core
All as per item No 123 described here-in-before but Size 120 Sqmm X3.5 core
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Supply and fixing of GI tubing, light grade, 80 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm complete all as specified and as directed by Engr-in-Charge
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 70 to 150 sq mm complete all as specified and as directed by Engr-in-Charge
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material of tubular sleeve version and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 185 to 400 sq mm complete all as specified and as directed by Engr-in-Charge
Supply and fix ON load four pole changeover switch with front handle of 4 pole 415 volt 50 Hz 400 amps in SS Enclosure and Conforming to IS/IEC : 60947-1 & 3 complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Danger notice plate of 1.6mm thick mild steel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fix with MS clamp/Nut bolt for LT complete all as specified and as directed by Engr-in-Charge
Supply only Aluminium lugs of any type complete all as per of sample of following sizes :-
(a) 16 Sqmm
(b) 25 Sqmm
(c) 50 Sqmm
(d) 70 Sqmm
(e) 95 Sqmm
(f) 185 Sqmm
(g) 240 Sqmm
(h) 300 Sqmm
Supply & Fixing in repair including making connection testing and commissioning of new MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA. Note: (a) make of MCCB shall be L &T , Havells, Strandard, crompton, C & S, Schneider or any other make as per the make in the existing plannel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .(b) Type of MCCB weather with operating knob or handle type shall be procured as per site requirement all as specified and as directed by Engr-in-Charge
All as per item No 144 described here-in-before but MCCB TP 160 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete all as specified and as directed by Engr-in-Charge
All as per item No 144 described here-in-before but MCCB TP 250 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete all as specified and as directed by Engr-in-Charge
All as per item No 144 described here-in-before but MCCB TP 125 Amps, 36 KA with Adjustable thermal setting ( 80 to 100 %) complete all as specified and as directed by Engr-in-Charge.
All as per item No 144 described here-in-before but 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA. all as specified and as directed by Engr-in-Charge
All as per item No 144 described here-in-before but 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. all as specified and as directed by Engr-in-Charge+
All as per item No 144 described here-in-before but 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA all as specified and as directed by Engr-in-Charge
Supply and fix in repairs power contactor 3 pole, type MNX- 45, with 2 NO + 2 NC aux contacts with standard coil voltage 240 volts, 50 Hz, rating 80 Amp including NO + NC of all as specified and directedby Engr-in-Charge.
Supply and fix electronic timerrange 09 to 30 sec 240/415 volts ST 100 fixed in repairs of all as specified and directed by Enge-in-charge.
M&L for defect rectification in LT/HT cable laid in trenches up to 300 Sq mm 3/3.5 core cable with the help of electronic fault locating machine/FLC comprising of surge generator pulse/CFC /ECHO fault locator high pressure resistance and distance calculation for faults exposing the fault, removal of deteriorated portion and for cable joint complete all as specified and as directed by Engr-in-Charge
M&L for disconnecting worn out cable of up to 300 Sqmm size from main control panel cutting worn-out portion and reconnecting with control panel with suitable size of thimbles by incl excavation of earth work for taking out cables from loop complete all as specified and as directed by Engr-in-Charge
M&L for carrying out horizontal boring below roads/PCC hard sanding/Drains all as specified as directed for inserting GI pipe of the following sze with a depth upto 1.5m & length of road upto 12 m of the suitable for 40 & 80 mm dia GI pipe all as specified and as directed by Engr-in-Charge
Supply and fix in repair ACB 4 pole 415 volts ,800 amps , AC 50 Hz with breaking capacity 50 KA conforming to IS/IEC-60947-2 with themal magnetic release and manual drawout type ( Thermally adustable type ) inclding electrical connection as per site requirement complete all as specified and directed . Make - L&T / ABB / Siemence Note: (a) make of ACB shall be L &T , Havells, Strandard, crompton, C & S, Schneider or any other make as per the make in the existing planel board or exactly suitable to the existing frame size. In case only one particular make is procuring by the bidder necceasry alteration required to fix the same at no extra cost shall be done by the bidder .(b) Type of ACB weather with operating knob or handle type shall be procured as per site requirement all as specified and as directed by Engr-in-Charge
S&F busbar panel of size 600mmx450mmx 200mm one piece fabricated out 3mm thick MS sheet, front openable door with hinges, weather proof duly painted internally and externally over a coat red oxide primer suitable to house and including 04 Nos aluminium bus bar of 200 Amps capacity mounted on suitable insulators internally wired with suitable size of copper conductor, provision of bottom entry for incomming and outgoing cable with cable glands mounted on four number angle iron frame including PCC foundation and grouted on PCC Complete all as specified and directed by Engr -in- Charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose soil including forming bottom surface to required level and slope all as specified and as directed by Engr-in-Charge
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm soil all as specified and as directed by Engr-in-Charge
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the strarting point. all as specified and as directed by Engr-in-Charge
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .
Supplying and laying un-reinforced precastconcrete cable cover,Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and directed by Engr in- charge..
M & L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 25×4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar all as specified and as directed by Engr-in-Charge
Supply and fix in repairs in repair on-off push button pendants with elements red/green/orange of make MIMIC/ M/s L&T/ Legrand / HPL all as specified and directed.
Supply and fix in repairs in repair toggle switch of 5 Amp capacity of make M/s Kaycee or equivalent make M/s Legrand / HPL all as specified and directed.
Supply and fix in repairs in repair indication lamp of make M/s L&T or equivalent make of M/s Legrand / HPL all as specified and directed.
Servicing, Oiling, Greasing and Cleaning of split type AC 1.5 Ton Capacity with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.by Engineer in charge .
Servicing, Oiling, Greasing and Cleaning of split type AC 2.0 Ton Capacity with high pressure pump of any capacity, checking of defects/ leaking and adjusting setting to work and testing complete all as specified & directed.by Engineer in charge .
M & L for cutting of suction line and discharge line tubing of AC, front scaled unit de-scaling, flushing out condenser and cooling coil thoroughly and reconnecting with the seal unit and charging of gas with required qty of refrigerant for 1.5 ton Split type AC all as specified and as directed by Engr-in-Charge
All as per item No 132 described here-in-before but 2 ton capacity split type AC complete all as specified and as directed by Engr-in-Charge
M& L for detection/ rectification of leakage of gas in the Split AC of capaicty 1.5 /2.0 Ton and gas charging in the system with appropriate qty of gas including testing for smooth functioning of AC of capacity 1.5 /2.0 Ton complete all as specified and as directed . Note :-(i) Unserviceable condensing coil if reqd shall be measured and paid for separately .(ii) Cost of dismantling of unserviceable compressor if reqd deemed to be included in unit rate . (iii) compressor shall be measured and paid separately under respective items of sch 'A".(iv) Refilling & topping up refrigent (type & quantity as required on site is deemed to be included in quoted rates only) all as specified and as directed by Engr-in-Charge
S & F Voltage stabilizer for automatic operation , single phase naturally air cool indoor type& designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of 2.5% +/- and of capacity of 5 KVA complete all as specified and as directed by Engr-in-Charge
M&L for replacement running capacitor of existing makes and capacity duly ISI marked suitable for split type AC 1.5/2.0 Ton capacity all as specified and as directed by Engr-in-Charge
M&L for replacement of starting relay of existing makes and capacity duly ISI marked for split type AC 1.5/2 Ton capacity complete all as specified and as directed by Engr-in-Charge
M&L for replacement starting capacitor of existing make and capacity duly ISI marked for Split type AC 1.5/2.0 Ton capacity complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Normal type Electronic control (PCB) of existing makes and capacity duly ISI marked for split type AC 1.5/2 Ton capacity all as specified and as directed by Engr-in-Charge
S&F in replacement Electronic control (PCB) card for inverter type 2.0 Ton Split AC of voltas make complete all as specified and directed.
S&F in replacement universal type remote for 1.5 /2.0 Ton Split AC unit of make voltas all as specified and as directed by Engr-in-Charge
S&F in replacement of Suction/Discharge valve of 1.5 /2. Ton Split AC unit complete all as specified and directed.
S&F Filter pad of existing makes and capacity duly ISI marked for split type AC 1.5/2 Ton capacity all as specified and as directed by Engr-in-Charge
S&F in replacement of Thermostat switch of existing makes and capacity duly ISI marked for split type AC 1.5/2 Ton capacity all as specified and as directed by Engr-in-Charge
M & L for Rewinding of blower motor of Split type AC capacity 1.5/2.0 Ton all as specified and as directed by Engr-in-Charge
S&F in replacement of new rotary type compressor for Voltas Make 1.5 Ton Capacity split AC including gas charging and dismantling of old unserviceable compressor from existing outdoor unit complete all as specified and as directed by Engr-in-Charge
S&F in replacement of new rotary type compressor for Voltas Make 2.0 Ton Capacity split AC including gas charging and dismantling of old unsv compressor from existing outdoor unit complete all as specified and as directed by Engr-in-Charge
Supply and fixing for replacement of Evaporator coil for 1.5 /2.0 ton Split AC unit complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Copper tube for 2.0 Ton split AC 5/8 inch dia complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Copper tube for 1.5 /2.0 Ton split AC 1/4 inch dia complete all as specified and as directed by Engr-in-Charge
S&F in replacement of Copper tube for 1.5 Ton split AC 1/2 inch dia complete all as specified and as directed by Engr-in-Charge
S& F in replacement of complete outdoor unit including compressor suitable for 1.5 Ton split AC complete set including gas charging and testing to get sufficeint cooling complete all as specified and as directed by Engr-in-Charge
S& F in replacement of indoor unit complete set with AC remote suitable for 1.5 ton split AC incl testing to get sufficeint cooling complete all as specified and as directed by Engr-in-Charge
S& F in replacement of complete outdoor unit including compressor suitable for 2.0 Ton split AC complete set including gas charging and testing to get sufficeint cooling complete all as specified and as directed by Engr-in-Charge
S& F in replacement of indoor unit complete set with AC remote suitable for 2.0 Ton split AC incl testing to get sufficeint cooling complete all as specified and as directed by Engr-in-Charge
M& L for detection/ rectification of leakage of gas in the system and gas charging in the system with appropriate qty of gas including testing for smooth functioning of water of capacity 60/80/120 ltrs complete all as specified and as direted . Note :-(i) Unserviceable condensing coil if reqd shall be measured and paid for separately .(ii) Cost of dismantling of unserviceable compressor if reqd deemed to be included in unit rate . (iii) compressor shall be measured and paid separately under respective items of sch 'A".(iv) Refilling & topping up refrigent (type & quantity as required on site is deemed to be included in quoted rates only) all as specified and as directed by Engr-in-Charge
S&F compressor reciprocating type (hermitecally) sealed for capacity 40/80 Ltrs water cooler complete all as specified and as directed by Engr-in-Charge
S&F in repair of thermostat switch suitble for existing water cooler anymake and capacity complete all as specified and as directed by Engr-in-Charge
M&L in replacement of Starting relay and overload relay suitable for existing size & make water cooler complete all as specified and as directed by Engr-in-Charge
M&L in replacement of Starting capacitor suitable for 40/80 ltrs water cooler of any make complete all as specified and as directed by Engr-in-Charge
M&L in replacement of running capacitor suitable for 40/80 ltrs water cooler of any make complete all as specified and as directed by Engr-in-Charge
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed by Engr-in-Charge
M&L servcing of Deep freezer Capacity upto 320 ltrs by cleaning greasing, including refrigerant gas filling up to required level complete all as specified and as directed by Engr-in-Charge
S&F in replacement Electronic control (PCB) card for deep freezer 320 Ltrs Capacity any make complete all as specified and as directed by Engr-in-Charge
S&F in replacement of insulation pipe size ¾” or 1” dia for split AC 1.5 / 2 Ton complete all as specified and directed. Note :- Rate quoted by contractor should include making the distrub surface as this (plastering & white washing & painting with same) all as specified and as directed by Engr-in-Charge
Material and labour for drain pipe heavy duty rigid and flexible 20mm dia with clamps of suitable size as per site requirement all as specified and as directed by Engr-in-Charge
S&F in replacement of fan blade of condenser motor of any make and capacity of water cooler/AC/Ref or deep freezer complete all as specified and as directed by Engr-in-Charge
M& L for repair and maintenance refrigerator of any capacity including replacement of following UNSV Parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, thermostate switch - 01 No, Door rubber beeding set - 01 Set complete all as specified and as directed by Engr-in-Charge
S&F in repair replecement compressor of suitable for Refrigerator of single phase, 230 Volt, 50 Hz of Refigerator in and including refrigerant gas filling up to required level complete all as specified and as directed by Engr-in-Charge
Taking down carefully copper/aluminium point wiring light ,fan, socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and as directed by Engr-in-Charge
Taking down old unserviceable main switch/DBs/mCB DBs with MCB including making good the disturbed surface complete all as specified and as directed by Engr-in-Charge
Taking down sub main wiring of any size complete all as specified and as directed by Engr-in-Charge
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and as directed by Engr-in-Charge
(a) One light point controlled by one switch one way
(b) One celling/exhaust fan point controlled by one switch one way
(c) One socket out let 5 Amps 5 pin on independent board
(d) One socket outlet 5 Amps 5 Pin on same board with other switches
All as per item No 213 here in before but with cable size 2.5 Sq mm for one 3/5 pin 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and as directed by Engr-in-Charge
S&F in replacement of modular switches 6 amps 1 module one way
S&F in replacement of modular socketes out let 6 amps 5 pin
S&F in replacement of modular socket out let 6-16 A 3 pin combined shuttered
S&F in replacement of modular switches 16 A 1 module one way
S&F in replacement of ceiling rose surface bakelite two to three terminals.
S&F in replacement of Ceiling Fan step regulator, 1 module stepped electronic type all as directed.
S&F in replacement of modular white cover plate with frame 3 modular
S&F in replacement of Flush metal boxes 3 modular
S&F in replacement of modular white cover plate with frame 6 modular
S&F in replacement of Flush metal boxes 6 modular.
S&F in replacement of modular white cover plate with frame 8 modular
S&F in replacement of Flush metal boxes 8 modular.
S&F in replacement of MCB distribution board vertical triple pole and neutral 12 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB distribution board triple pole and neutral 4 way factory made sheet steel, phosphates, powder painted with 200 Amps rated busbar, 415 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB distribution board single pole and neutral 8 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB distribution board single pole and neutral 4 way factory made sheet steel, phosphates, powder painted with 100 Amps rated busbar, 240 volts, neutral link, earth bar and Din rail double door complete including taking down/dismantling of old unserviceable one all as specified and as directed by Engr-in-Charge
M/L for Sub main wiring with 2 Run of 4 Sqmm cable and one run of 4. sqmm as earth wire PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and as directed by Engr-in-Charge
M/L for Sub main wiring with 2 Run of 2.5 Sqmm cable and one run of 2.5 sqmm as earth wire PVC insulated, unsheathed FR cable of multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories concealed on wall and surface on ceiling complete all as specified and directed by Engineer in charge.
S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt all as specified and as directed by Engr-in-Charge
S&F in replacement of geyser assembly suitable to fix thermostat , heating element as of the existing model & size including all clamps with bolts and nuts etc .
S&F in replacement of heating element 2000 watt capacity triangular type complete all as specified and as directed by Engr-in-Charge
S&F in repair innner water container ISI Marked made of SS, vertical or horizontal type for 25 ltr capacity gyser all as specified and as directed by Engr-in-Charge
S&F in repair of aparatus plate ISI marked suitable for vertical/horizintal type Geyser 25 ltr cap all as specified and as directed by Engr-in-Charge
S&F in repair heavy duty PVC connections pipe with brass hexagonal adoptersat both side 15mm dia and 450mm long for hot /cold water all as specified and as directed by Engr-in-Charge
S&F PVC insulated PVC sheathed copper flexiable wire multistrand 4sqmm 3 core, ISI marked all as specified and as directed by Engr-in-Charge
S&F in replacement of capacitor 2.5 mfd 230 volts 50 Hz complete all as specified and directed.
Supply and Fixing in repair of wall mounting fan 400 mm sweep 230 Volt oscillating type complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of exhaust fan steel body, heavy duty, AC Single phase, voltage 230V, 50 Hz, Copper winding of size 380 mm sweep with, blades and frame and lovers complete all as specified and as directed.
Supply and fix in replacement of exhaust fan steel body, heavy duty, AC Single phase, voltage 230V, 50 Hz, Copper winding of size 450 mm sweep with, blades and frame and lovers complete all as specified and as directed by Engr-in-Charge
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and as directed by Engr-in-Charge
M&L for disconnecting electric supply and dismantling of old defective exhaust fan motor of size 450 mm sweep heavy duty steel body exhaust fan, and carry to workshop for repair/ rewinding with super enamelled copper wire and refixing & testing the same all as specified and as directed by Engr-in-Charge
M&L for disconnecting electric supply and dismantling of old defective exhaust fan motor of size300 mm sweep plastic body exhaust fan, and carry to workshop for repair/ rewinding with super enamelled copper wire and refixing & testing the same all as specified and as directed by Engr-in-Charge
M&L for Rewinding of Ceiling fan 1200 mm sweep after dismenting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, vernishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans form the complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Cost of Spares require for replacement such as bearing, Bushing, capacitor shall be inclusive of the quoted rate. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate all as specified and as directed by Engr-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less thatn 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers GI earth wire with protected by 15mm dia light grade GI pipe and other end connected to earth testing point or main controlling switch as directed incl funnel with watering pipe 20mm bore light grade GI pipe, wire mess , charcol and common salt, concrete earth pit in PCC (1:3:6) type C1 cast iron frame cover , including necessary excavation, earth work in soft/loose soil and disposal of soil to a distance not exc 50mtr and necessary testing complete all as shown in electrical plate No 3 of MES schedule Part I and testing all as specified and as directed by Engr-in-Charge
Supply and fixing in replacement Pressure die cast aluminium housing LED street light luminaires with IP66 of 45 Watts complete all as specified and as directed by Engr-in-Charge
Supply and fixing in replacement LED Bollard 8 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by dept. all as specified and as directed by Engr-in-Charge
S&F PVC Conduit 20 mm Dia ISI marked including junction box,bend,albow,MS shedel grouting work etc.complete all as specified and as directed by Engr-in-Charge
S&F PVC casing caping 20mm ISI marked including junction box,bend,albow,MS shedel grouting work etc.complete all as specified and as directed by Engr-in-Charge
S&F in replacement of PVC gang box with one switch and socket 5/15 Amps complete with screw and necessary fixing arrangement complete all as specified and as directed by Engr-in-Charge
S&F in replacement of tube light fitting 1X20 w,LED Batten wall mounted with alumunium housing and integrated electronic driver . all as specified and as directed by Engr-in-Charge
S&F in replacement of tube light fitting 1X10 w,LED Batten wall mounted with alumunium housing and integrated electronic driver . all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB SP 240 volt, 6 to 32 Amps, C series, 10 KA complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB SPN 6-32 Amps, 10 KA,240V, 50Hz, 'C' Series complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB SPN 240 volt, 40 to 63 AMP 10 KA (C-Series). complete all as specified and as directed by Engr-in-Charge
M&L for disconnecting electric supply and dismantling of old defective Desert cooler fan motor of existing make and model , and carry to workshop for repair/ rewinding with super enamelled copper wire and refixing & testing the same all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of fan motor of desert cooler of existing make and model complete all as specified and as directed by Engr-in-Charge
M&L for replacement of tullu pump submersible for desert cooler complete all as specified and as directed by Engr-in-Charge
M&L for plastic distributor 3 way with 03 Nos PVC elbow of super quality for water cooler complete all as specified and as directed by Engr-in-Charge
M&L for replacement of cut wood pad set of superior quality for desert cooler complete all as specified and as directed by Engr-in-Charge
M&L for replacement of fan motor blade suitable of any size of desert cooler complete all as specified and as directed by Engr-in-Charge
S&F in replacement of capacitor 4.0 mfd 230 volts 50 Hz complete all as specified and as directed by Engr-in-Charge
S&F in replacement of capacitor 6.0 mfd 230 volts 50 Hz complete all as specified and as directed by Engr-in-Charge
Material and labour for PVC Garden pipe heavy duty and flexible 15 mm diac all as specified and as directed by Engr-in-Charge
Material and labour for replacement of defective Desert cooler fan motor mounting stand made out of MS material including painting, replacement of nut, bolts, washers, suitable for existing size fan motor complete all as specified and as directed by Engr-in-Charge
M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed all as specified and as directed by Engr-in-Charge
sheetal engineering (BID ID -3368689)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .