GE Jammu c/o 56 APO Pin-900277
REPAIR AND MAINT OF MES INSTALLATION, PAINTING OF POLES, EARTHING, TRIMMING OF TREES, CLEANING OF E/M INSTALLATIONS INCLUDING STP, PETTY REPAIR TO INTERNAL WIRING, FITTINGS AND ALLIED ITEMS AT DAMANA UNDER GE JAMMU
2022_MES_525955_2
GEJC-17/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹70,000
Yes
13 Oct 2022
1 Aug 2022
27 Aug 2022
1 Aug 2022
25 Aug 2022
12 Aug 2022
Amount
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/stay assembly/cable complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr deep but not exc 3.0 mtr deep any type of soil getting out and levelling of bottom surface to required level for poles/stay assembly/cable complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25m thick complete all as specified and directed.
Removing excavated material from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed.
Supplying and Laying in ducts/trenches clear sand for cushioning underground cable 8 cm below and 15 cm above complete in level complete all as specified and directed.
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable, adjacent/abutting each other in trenches over the cable for protection complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
M&L for PCC (1:2:4) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, coping, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
Supply and fixing in replacement of submersible cable 10 Sqmm 2 core flat copper conductor heavy duty 1100 Volts grade confirming to ISI complete all as specified and directed by Engineer-in-Charge.
M&L for loose filling with aggregate of gauge 40mm broken stone and boulder deposited, spread, levelling in layer n.exc 15 cm thick, watered and ramming at E/M installation around 50 mtr of transformer complete all as specified and directed.
Taking down cement plaster of any description on bricks or stone walls or from concrete surface or from concrete surface and similar including racking out joints, hacking for key, scrubbing down with water and removing unserviceable material outside the cantt area complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick (average) in CM (1:4) on concrete surface / brick surface and similar including two or more dubbing coat, surface finished even and fair without using extra cement with necessary frame work, scaffolding for external surface complete all as specified and directed.
M&L in replacement of GI Pipe light grade 80 mm bore for cable protection as a guard pipe complete all as specified and directed.
M&L in replacment of GI Pipe light grade 50 mm bore for cable protection as a guard pipe complete all as specified and directed.
M&L in replacment of GI Pipe light grade 40 mm bore for cable protection as a guard pipe complete all as specified and directed.
Taking out existing burnt defective underground XLPE cable of any size of 1100 Volt grade from trenches / poles complete with protection pipe, sand cushioning, bricks etc for repair / rectification of fault and relaying the same cable in position after necessary repair / rectification of fault complete with relaying new bricks, fresh sand, protection pipes etc and connection incuding testing all as per site requirement complete all as specified and directed.
Repair / maint of existing burnt defective underground XLPE cable 1100 Volt grade cable of any size (50RM) complete with charges for trace out the fault, cutting / repair and jointing complete with using insulation tape, aluminium thimble, lugs, fitment of jointing kit, thimbles, necessary earth work complete all as specified and directed. Note: - Aluminium thimble, lugs, jointing kit, thimbles, earth work shall be measured and paid seperately.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 300 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 240 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 185 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 120 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 70 / 95 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 50 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 35 Sqmm complete all as specified and directed.
Supply and fixing in replacement unserviceable aluminium lugs / thimble of size 25 Sqmm complete all as specified and directed.
Supply and fixing in replacement of cable end jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3½ or 4 core XLPE armoured aluminium conductor cable of size 25 to 95 Sqmm complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11000 Volts grade cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 Sqmm and jointing materials for making joints and testing complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11000 Volts grade cable indoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 185 Sqmm and jointing materials for making joints and testing complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11000 Volts grade cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 Sqmm and jointing materials for making joints and testing complete all as specified and directed.
Supply and fixing in replacement of cable jointing kit for 11000 Volts grade cable outdoor termination heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 185 Sqmm and jointing materials for making joints and testing complete all as specified and directed.
Supply and fixing in replacement of indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 / 4.0 x 10-50 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 400 Sqmm complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 / 4 x 25-50 Sqmm complete all as specified and directed by Engineer-in-Charge. Note: - Earth work will be measured and paid separately.
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and directed by Engineer-in-Charge. Note: - Earth work will be measured and paid separately.
Supply and fixing in repair straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-400 Sqmm complete all as specified and directed by Engineer-in-Charge. Note: - Earth work will be measured and paid separately.
M&L in repair cable jointing kit for 11000 Volts grade cable outdoor straight through heat shrinkable type joint complete with jointing material suitable for 3 core XLPE armoured aluminium joint conductor cable of size 95 / 120 Sqmm and jointing materials for making joints and testing complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC fibre separator for LT line 1100 Volt overhead conductor 3 wire system for maintaining horizontal / vertical spacing of conductor complete with nut and bolt in a span complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC fibre separator for LT line 1100 volt overhead conductor 4 wire system for maintaining horizontal / vertical spacing of conductor complete with nut and bolt in a span complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC fibre separator for LT line 1100 volt overhead conductor 5 wire system for maintaining horizontal / vertical spacing of conductor complete with nut and bolt in a span complete all as specified and directed by Engineer-in-Charge.
Labour for re-stretching, tightening of existing swagged ACSR overhead conductors spans of any size / type on HT / LT poles including necessary new aluminium binding wire for fixing with insulator / PVC sleeves for jumper etc as required complete all as specified and directed. Note:- Pole to pole will be considered as one span of any length and no's of conductor.
Supply and fixing in replacement of ACSR conductor of any size and type from overhead HT / LT poles including binding at site to insulator with suitable size of binding wire etc including taking down existing worn out old broken ACSR conductor of any size and type and length at any position from LT / HT poles complete all as specified and directed.
M&L in replacement of Galvanised steel wire 4.0 mm dia for continuous earth wire and craddles hexagonal / rectangular shall be provided and securely fastened to each pole and connected with earth ordinarily and craddle guarding where required complete including dismantling existing GI wire complete all as specified and directed.
M&L in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e. M.S. channel or angle sections etc. including new nuts, bolts, washers as required dia / length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide, one under coat and one finishing coat of silver paint (1st quality) as required complete all as specified and directed.
Labour for cutting of tree branches 2 metre vicinity of the conductor which are touching to the 11 / 9 metre overhead lines in vertically and horizontally conductor and poles etc, complete clear in a standard span in between two poles as per SSR Part-I, 19.59 and removing cutting material not exc 50 mtr and depositing where directed at a distance level not exc 3 metre from starting point complete all as specified and directed. Note: - Pole to pole will be considered as one span of any length and no's of conductor.
M&L for welding to damaged / broken hinges of unserviceable LT panel board shutters complete with painting and matching with existing colour complete all as specified and directed. Note: - Welding of two no hinges considered as one Job.
M&L for replacement of old unserviceable / broken shutter of LT panel with 3 mm thick CRCA sheet as per existing size to match with the existing panel duly powder coated and welding hinges and fixing complete all as specified and directed by Engineer-in-Charge.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing surface internally and externally including preparation of old rusted surface after taking proper shut down complete all as specified and directed by Engineer-in-Charge.
M&L Painting of transformer externally with two coats of spray painting with heat resistance / smoke gray heat resistance synthetic enamelled paint after cleaning rusted surface thoroughly with thinner and scrapper and preparing the surface to required standard including writing and marking such as MES No, SM No, capacity, on the body of transformer capacity upto 400 KVA complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular poles 11/9 metres long type 410 SP-31, 55 and applying one coat of synthetic enamel paint upto 1.2 metre height in black and white strip of width 30cm each as per existing pattern above the P.C.C coping and two coats of aluminum paint (1st quality) beyond 1.2 metre height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 metre radius complete all as specified and directed.
Material and labour for preparation of old painted surfaces of PCC poles 11/9 metres long type 410 SP-31, 55 and applying two coats of synthetic enamel paint upto 1.2 metre height in black and white strip of width 30cm each as per existing pattern above the P.C.C coping and two coats of aluminium paint to cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 metre radius complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular two pole structure 11/9 metres long type 410 SP-31, 55 and applying one coat of synthetic enamel paint upto 1.2 metre height in black and white strip of width 30cm each as per exising pattern above the P.C.C coping and two coats of aluminum paint (1st quality) beyond 1.2 metre height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 metre radius complete all as specified and directed.
Material and labour for preparation of old painted / rusted surfaces of steel tubular four pole structure 11/9 metres long type 410 SP-31, 55 and applying one coat of synthetic enamel paint upto 1.2 metre height in black and white strip of width 30cm each as per existing pattern above the P.C.C coping and two coats of aluminum paint (1st quality) beyond 1.2 metre height (for the rest of portion) including cross arms and channel, angle fitted on the pole including writing pole numbers and cutting vegetation growth all around and on the poles upto 1 metre radius complete all as specified and directed.
Dismantling and taking down old unserviceable steel tubular swagged poles any type after disconnecting all electrical connection including clearance of site complete all as specified and directed.
Supply and erection of steel tubular swagged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31, 9 metre long including providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 metre above the coping of pole starting with black strip complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 2 KVA complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 1 KVA complete all as specified and directed.
Repair / maint / servicing of 175 KLD sewage treatment plant with dismantling of all connected valves and refix after greasing / oiling, taking down and cleaning of all MS / GI pipes of any size approx length 150 RM, cleaning of MBBR tanks both cylindrical and rectangular, cleaning bleaching chamber, cleaning of foot valves of monoblock pumps complete all as specified and directed.
Replacement of multi-functional valve for ACF / DMF midas 50 NB suitable size and make for existing ACF and DMF filters complete all as specified and directed.
Replacement of MS Pipe 80mm dia with all connected fittings complete all as specified and directed.
Replacement of Non clog vertical sub pump 3 HP, 230 Volt with chrome steel impeller and cutter, non clog to pass 40 mm size particles, submersible cable 6 Sqmm 2 core - 60 RM, installation with NRV, laying of MS pipe 40 mm dia upto MBBR chamber complete all as specified and directed.
Replacement of brass material butterfly valve 50 mm dia complete all as specified and directed.
Replacement of brass material butterfly valve 80 mm dia complete all as specified and directed.
Replacement / repair of ACF / DMF materials suitable for 175 KLD STP including new filling of crushed gravel, pebbles, filtering sand media with anthracite coal, filling of the same, reactivate the ACF / DMF completely after servicing / maint complete all as specified and directed.
Repair of monoblock pumping set including motor upto 3 HP and including replacement of suitable necessary parts like winding, circuits, bearing and other moving parts complete all as specified and directed.
Repair of compressor system with motor upto 5 HP and including replacement of suitable necessary parts like winding, circuits, fan belts, bearing and other moving parts complete all as specified and directed.
Removing of sludges / sands / waste particles from primary and secondary chambers, disposal of the waste particles to a distance 100 metre from STP cleaning of the chambers after removal of sludges and clean the entire chamber by using bleaching powder complete all as specified and directed.
M&L in repair for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and directed.
M&L in repair for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25 metre deep below normal ground level with top edge of the plate not less than 1.5 metre below ground level connected to galvanized iron strip of size 25 x 4mm by means of nut / bolt and washer of galvanized iron or steel as shown in electrical plate no 5 of SSR part-I including necessary excavation and earth work GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of GI earth wire etc, PCC chamber with RCC cover in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate), funnel, wire mesh, charcoal dust, salt layers each layer thickness should be 15 cm (layer start from below the electrode plate to above plate) etc, connected to LT panel board as indicated including testing complete all as specified and as directed.
M&L for repair / maint to desert coolers complete with and including cleaning, scrapping / rubbing old rusted surface, filling cavities and painting with two coats of high quality aluminium paint over a coat of red oxide primer externally and black paint internally with synthetic enamelled paints complete with replacement of necessary nut, bolts, rubber pads for fan motors and writing MES No / unit name complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of desert cooler fan motor 90 watt, 1400 RPM, 230 Volt 50 Hz single phase conforming to ISI complete with fan blade and capacitor of suitable size complete all as specified and directed.
Supply and fixing in replacement of Desert Cooler submersible pumping set single phase 230 Volt, 50 Hz of 0.25 to 1.0 HP conforming to ISI complete with lead complete all as specified and directed.
Supply and fixing in replacement of desert cooler fan motor blade of existing size made out from mild steel having duty complete with key bolt complete all as specified and directed.
Supply and fixing in replacement of desert cooler side opening cover made out from heavy duty mild steel sheet and matching with the existing desert cooler body size complete with Khas Khas pads set of three pieces complete all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 1.5 Sqmm 3 core FRLS 230 Volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement cable PVC insulated and sheathed of size 2.5 Sqmm 3 core FRLS 230 Volt, 50 Hz conforming to ISI complete all as specified and directed.
Supply and fixing in replacement of plug top 3 pin 5 Amp 230 Volt 50 Hz complete all as specified and directed.
Supply and fixing in replacement of PVC accessories of capacitor 2.5 MFD for desert cooler fan motor, 230 Volt 50 Hz complete all as specified and directed.
Supply and fixing in replacement of unserviceable Khas Khas / Glass wool for desert cooler set of three pieces complete all as specified and directed.
Repair / Maint / Servicing to refrigerator / deep freezer / water coolers / AC's of any capacity and model by replacing capillary tubing, gas chargings, rectification of leakage in capillary tubing / Chiller plant / water tanks, condensing coils, repair to wiring, flushing / cleaning condensing / cooling coils / internal / external unit of split AC, greasing to blower motors, replacement of spare parts, fan belts and make refrigerator / deep freezer / water coolers / AC's in serviceable condition complete all as specified and directed by Engineer-in-Charge. Note: - Spare / Gas charging shall be paid separately.
Charges for fixing in replacement of unserviceable sealed seamless welding compressor unit company manufacturer of any capacity for AC's complete with initial filling / charging of refrigerant gas to meet the requirement complete with vibration rubber pads four no's each nut, bolts etc and testing on full load complete all as specified and directed by Engineer-in-Charge. Notes: - (i) Spare parts shall be measured and paid separately under respective items. (ii) Contractor shall be responsible for all replacement of failed compressor and shall be accompanied by certificate from the original compressor to the effect that said compressor has been repaired at their authorized service center. Further, a warranty of 12 month shall be provided on such replacement in writing.
Supply only sealed compressor unit seamless welding company manufacturer with filling of refrigerant gas complete all as specified and directed conforming to ISI as under: -
For refrigerator 165 / 286 litre capacity
For refrigerator 290 / 320 litre capacity
For Deep Freezer 100 / 200 litre capacity
For Deep Freezer 300 / 400 litre capacity
For Water Cooler 40 / 80 litre capacity
For Water Cooler 60 / 120 litre capacity
Split / Window AC 1.5 Ton capacity
Split / Window AC 2.0 Ton capacity
Supply and fixing in replacement of unserviceable / burnt condensing fan motor 1/35 HP single phase 230 volt 50 Hz complete with blade, fan belts for water cooler of capacity 40 / 80 litre and 60 / 120 litre complete all as specified and directed.
Supply only condensing fan motor 1/5 HP 1440 RPM single phase 230 Volt 50 Hz with double blade and shaft end with fan belts for windows AC / Split AC conforming to ISI of capacity 1.5 / 2.0 ton complete with vibration parts etc complete all as specified and directed.
Supply and charging refrigerant 134a / R-22 / 412A in sealed compressor unit of refrigerator / deep freezer / water coolers / AC's of any type and capacity after flushing the complete system with carbon tetrachloride (CTC) and vacuumise the complete system with vacuum pump and testing on full load including replacement of filter, strainer complete all as specified and directed.
Supply and fixing in replacement of following spare parts for refrigerator / deep freezer / water coolers / AC's of any capacity: -
Starting relay
Overload protector
Thermostat switch
Defroz switch
Supply and fixing in replacement of following unserviceable spare parts of water cooler of any capacity: -
Starting capacitor 45 mfd
Running capacitor 60/120 mfd
Float valve PVC 15 mm dia with ball
Push cock chromium plated 15 mm with nipple 6'' long
Drain/wash out flexible down pipe 40 mm dia
Water tank door gasket
Water drain tray of suitable size
Supply and fixing in replacement of unserviceable following spare parts of window / Split AC unit of capacity 1.5 to 2.0 ton: -
Starting capacitor 36/40 mfd
Running capacitor 100/120 mfd
PCB of Split AC
Front Grill cover for window AC 1.5 Ton
Condensing fan motor double shaft
Supply and fixing in replacement of PVC flexible braided pipe of 20 mm dia for split AC water drain out complete all as specified and directed.
Supply and fixing in replacement of outer split AC condensing unit complete for split AC 1.5 ton complete all as specified and directed.
Supply and fixing in replacement of inner unit of split AC complete with filters, blower motor etc for split AC 1.5 ton complete with all accessories complete all as specified and directed.
Supply and fixing in replacement of copper capillary tubing 5/8'' for AC connection / repair complete all as specified and directed.
Supply and fixing in replacement of condensing unit of refrigerator / deep freezer / water cooler of any capacity complete with cutting and brazzing work complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 5 KVA complete all as specified and directed.
Supply and installation for replacement of automatic voltage stabilizer with back boost relay working range 90 to 290 Volt at 230 Volt of capacity 3 KVA complete all as specified and directed.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including pressed steel sunken / terminal boxes with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and directed for the following: - Note: - (a) Suitable module white cover sheets with frame as specified to be provided in replacement to mild steel / Galvanised sunken boxes and measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description all as per serial item No 102.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per serial item No 102.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and directed.
Description all as per serial item No 102.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and directed.
S&F in replacement modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement socket 6A / 16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular metal flush box 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
S&F in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
M&L for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
M&L for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
M&L for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 6 way 240 volts double door complete all as specified and directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
S&F in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
S&F in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
Supply and fixing in repair SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in repair SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and directed.
Charges for attending day to day / E/M petty complaint in respect of repair / rectification of fault in electric fitting MCB DB's, internal wiring LT panel and fixture and rectify the faults and replacement of unserviceable any type of fitting / fixture, MCB's, any type, bakellite sheet, restore the electric supply and made the item functionable light point, fan point, socket point 5A / 15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day / door to door maintenance, making the points / accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 metre) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses as and when directed. The scope also include cutting of existing bakellite sheet to accommodate new wiring accessories all type of electric fitting / fixture complete all as specified and directed.
Note: - Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting / fixture and MCB's of any type is deemed to be included in the above item.
(a) Contractor representative / Engineer will report to complaint cell for morning and afternoon to collect routine / urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (Two Electrician and Two Helper) equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be repaired and got signature of user's and will be deposited to complaint cell within 24 hours. In case of any delay in attending the complaint more than 12 hours after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (b) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (c) If the contractor did not attend complaint, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (d) The MES Department is not responsible for the payment of staff hired by contractor for attending complaints. The charges for attending the complaints by the Electrician will be deemed to be included in the item rate, as all the items of CA are to be supply and fixed by the contractor. (e) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (f) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (g) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5 Amp, 240 Volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 Volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin, 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and directed.
Supply only lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply only bell, AC 230 Volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps, 240 Volt 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
M&L in replacement of self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed.
S&F in replacement of LED light fitting 1 x 20W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and directed.
S&F in replacement of LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement wall mounted decorative type luminaries IP-65 with diffuser 10 watt, 230 Volts LED type complete with 10 watt LED bulb complete all as specified and directed.
S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
S&F in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and directed.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note: - Wiring shall be done in proper colour coding.
M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note: - Wiring shall be done in proper colour coding.
M&L in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and directed. Note: - Wiring shall be done in proper colour coding.
M&L in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and directed. Note: - Wiring shall be done in proper colour coding.
Supply and fixing in replacement of plug top 15 Amps complete all as specified and directed.
Material and labour in replacement for decorative post top lantern light for 360° indirect light with IP-65 protection, resistant to impact and corrosion, glare free and better uniformity including fixing of the light on the existing pipe arrangement and necessary wiring to light from nearest junction box complete all as specified and directed.
S&F in repair gate / post top lantern fittings, Orbiss type, die cast aluminium housing, frosted polycarbonate diffuser, matt grey finish with inbuilt LED 12 Watt, WW, IP-54, 300 mm Ht, 248mm dia, testing on completion complete all as specified and directed by the Engineer-in-Charge.
S&F in repair gate / post top lantern fittings, Monaco type, decorative fixture die cast aluminium housing, transparent glass diffuser, black colour with LED bulb 12 Watt, WW, IP-54 testing on completion complete all as specified and directed by the Engineer-in-Charge.
Dismantling and taking down old unserviceable building security lights and material and labour for new LED street light fittings of 30 Watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TIP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable building security lights and material and labour for new LED street light fittings of 45 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TIP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, commissioning and testing in repair LED flood lights 50 Watts, exclusive innovative IP-65 protection flood lights luminaire with 50 W high power COB LED as light source in repair complete all as specified and directed by Engineer-in-Charge.
Supply,fixing, commissioning and testing in repair LED flood lights 30 Watts, exclusive innovative IP-65 protection flood lights luminaire with 30 W high power COB LED as light source in repair complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair black epoxy powder coated Cone Bollard light with die cast aluminium housing, opal diffuser with in built LED 10 Watt CW, IP-65, height 600mm, 125mm dia on top in repair complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair black epoxy powder coated cylindrical bollard light with die cast aluminium housing, opal diffuser with in built LED 10 Watt CW, IP-65, height 600mm, 125mm dia on top complete all as specified and directed by Engineer-in-Charge.
S&F in replacement roof mounted hanging decorative type luminaries IP-54 with glass diffuser suitable for 10 watt LED, WW, 230 Volts complete including 10 watt LED bulb complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for 1100 Volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for 1100 Volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
Sarbat Construction Co
DARVESH ENGINEERING WORKS
Bidder Name
Sarbat Construction Co
M/s Sahib Construction and engineers
DARVESH ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .