Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.7 L+₹1,434 (0.54%)Rejected-Finance 95 2 RANI PARK BELGHORIA KOLKATA 700056 | KOLKATA | KOLKATA | WEST BENGAL | 700056 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.8 L+₹9,892 (3.73%)Rejected-Finance 2 JORA BAGAN STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹2.8 L+₹12,921 (4.87%)Rejected-Finance 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance L4 | |
| 5 | L5₹2.8 L+₹19,568 (7.37%)Rejected-Finance DAKHIN SHIBGANJ P O PATHAR PRATIMA SOUTH 24 PGS | PATHAR PRATIMA | SOUTH 24 PARGANAS | WEST BENGAL | 743371 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹6,162
Closing Date
18 Apr 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o The EE_KNED, PWDte., P-5, 2nd Floor, CIT Road, Kolkata- 700014
SITC of 2 nos. 10 passengers lift in Transport House at 45 G.C Avenue under G.C Avenue Electrical Section-----EI work for lift.
2022_WBPWD_375556_1
WBPWD/EE/KNED/NIT-01 of 2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
14 days
Transport House(45 GC Avenue)
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,162
29 Jun 2022
7 Apr 2022
20 Apr 2022
11 Apr 2022
18 Apr 2022
11 Apr 2022
Amount
S & Drawing of 4 core 35 sq mm PVC/A cable incl. supply & laying of 2 nos 10 SWG GI wire on wall by MS saddle. (Make-- KEI/Gloster/ Havells)
S & Drawing of 2 core 10 sq mm PVC/A cable incl. supply & laying of 1 no 10 SWG GI wire on wall by MS saddle. (Make-- KEI/Gloster/ Havells)
Supplying and fixing 4 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing attachment (Make- Legrand /ABB/ Siemens)
S & F 240/415V MCB (Legrand /ABB/ Siemens) of breaking capacity 10kA & 'C' characteristics on din rail of existing DB incl. necy connections.
32A FP MCB
40A DP Isolator
6-32A SP MCB
S & F (12+2) way Double door SPN MCB DB with IP-42/43 protection on angle iron frame on wall & mending good the damages to original finish incl. interconnection with suitable size cu wire and neutral link& provision for earthing attachment (Legrand make cat no. 607712 /ABB/Siemens)
Distribution wiring by 2x2.5+1x1.5 sq mm FR PVC insulated cu.wire (Finolex/KEI/Polycab) through 20 mm dia PVC rigid conduit (Precision-M) to light/fan/ call bell/exhaust fan pts.with piano key type switch on MS box incl. 3 mm thick b.k top cover and 3 nos cu bar as per GS .(Avg. run -8 mtr.)
Distribution wiring by PVC cu wire through 20 mm dia PVC rigid conduit (Precision-M) incl. necessary fittings as reqd.
2x2.5+1x1.5 sq mm
2x1.5+1x1.5 sq mm
Connecting the equipments body to earth busbar incl. S & F 25mm x 3 mm galvanised GI flat on wall/floor with GI saddles as reqd. and connection to equipments with bolts & nuts etc.
S & F 10Watt LED IP-65 Bulkhead light fittings (Make-Crompton/ Philips/Wipro) on wall incl. necy. accessories.
S & F 240V 1no 20A plug socket with 1 no 20A piano key type switch (Anchor) on wall incl. S & F MS box of size 150 x 100 x 65 mm (16 SWG) with 3 mm thick b.k top cover incl. making necy. connections.
S & F compression type gland complete with brass gland, brass ring for 2 core 10 sq mm PVC/A cable.
S & F compression type gland complete with brass gland, brass ring for 4 core 35 sq mm PVC/A cable.
Finishing the ends of the following cables & Cu wire by solderless socket, Tapes, anti corrosive paste. etc.
For 4 core 35 sq mm PVC/A cable
For 2 core 10 sq mm PVC/A cable
For 2x2.5+1x1.5 sq mm cu wire
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Excavation of soft soil for installation of earth electrode and filling incl. ramming the same properly.
S & F earth busbar of galvanized (Hot Dip) MS flat 40mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd (each 0.5 mtr)
Extra for treatment of soil by using salt & charcoal or coke for pipe earthing as per direction of EIC.
Hiring Charges for scaffolding arrangement incl. dismantling at the end of work and carriage for LC installation of vertical run.
S & Fixing of porceline post insulator (SP 65 of ASIAN electrical & Electronics) suitable for passing for earth conductor (As approved by EIC) with 2 nos screw on wall/parapet including suitable arrangement for fixing of earth continuity flat.
Extra for providing masonary enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep complete with cemented brick work of 25 cm width duly plastered with cement morter CI hinged inspection cover of size 35.56 x35.56 cm with locking arrangement GI reducer incl. drilling holes on the GI pipe.
Supply & Laying 50 mm dia GI pipe protection in UG trench, different drain for 25mm x 6mm GI flat.
Making soldered joints between GI strips & Air-terminals and other metallic objects incl. supply of jointing materials with 2 nos 8 mm dia and 3/4 th length nut bolt of same materials with contact grease and painting with 2 coats of bituminous paint.
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.63A[L&T/Siemens/Havells]
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.100A[L&T/Siemens/Havells]
Dismantling charges for dismantle the existing lift electrical installation by skilled labour with proper safety belt & safety cap & carry the same & deposited it to section store.
MODERN ENGINEERING CONCERNS
R.N.ROY ELECTRICAL CONTRACTOR
S. A. ENTERPRISE
B. ENGINEERING CO.
C. CHOWDHURY AND CO
technical_732171.pdf
PDF • 0.73 MB
techsummary_732171.pdf
PDF • 0.73 MB
finance_732171.pdf
PDF • 0.72 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_732171.pdf
PDF • 0.77 MB
NIT_01_Alpha.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .