Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC 22 319 GALI NO 5 MAHABIR PARK BAHADURGARH 124507 HARYANA | JHAJJAR | HARYANA | 124507 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹39.4 L+₹4.0 L (11.2%)Rejected-Finance N A | NEW DELHI | DELHI | 110001 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹39.8 L+₹4.4 L (12.3%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹41.8 L+₹6.4 L (18.1%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹46.2 L+₹10.8 L (30.4%)Rejected-Finance 0 0 GOVERNMENT HOSPITAL ROAD POST AHERI TAH AHERI GADCHIROLI MAHARASHTRA 442705 | GADCHIROLI | MAHARASHTRA | 442705 | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹48.4 L
EMD Value
₹96,820
Closing Date
7 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
PROVN OF CERTAIN REVENUE AND MINOR WORKS AT BHDC UNDER GE (EAST) DELHI CANTT-10
2025_MES_700916_1
GE/DE-126/2024-25
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D Cat a (i) and b (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹96,820
Yes
23 Jun 2025
10 Mar 2025
9 Apr 2025
10 Mar 2025
7 Apr 2025
24 Mar 2025
Amount
Excavation in trenches nexc 1.5 m deep and nexc 1.5 m wide for foundation cess pit etc and getting out in soft/ loose of soil.
Excavation in post hole in soft / loose (similar hole) each n exc 0.5 Cum getting out, returning filling and ramming earth or brocken rubble mixed with earth around in layer not exc 25 CM watering and removing surplus soil to a distance n exc 50 M and making good surface complete all as specifide and directed.
Returing and filling in, including spreading levelling, watering and well ramming in layers n exc 25cm thick in excavated soil
Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level nexc 1.5m above the starting point
M & L for PCC 1:2:4 type B2 40 mm graged agg in Posts, pillar, walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) and necessary form work complete all as specified.
M & L for brick work with sub-class B brick straight or curved on plan built in cement mortar 1 : 6 complete all as specified and directed
M & L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or on concrete surfaces finished fair and even complete.
M&L for PCC (1:3:6) type C-2 (40 mm graded aggregate) as in drain/Channal and mass concrete complete all as specified and directed.
M&L for 100mm PCC type D -2 (1:4:8) using 40 mm graded crushed stone aggregate as in Sub base complete all as specified and directed.
M&L for 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S&F steel tubular column, Rafter ,Purline etc. including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979gradeSt- 240.
S&F plate (plain or chequered ) channels ,square cut or notched ( oridinary and counter sunk) forming holes , w/o any attatchment.
M&L for mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both end each screw end to be fitted with washers and one hexagonal or square nut dia of neck 16mm and 60 cm long.
S&F pre-painted galvatume aluminium zinc coating GI based corrugated crimp curved steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
M&L for two coats of synthetic enamel paint on new steel surfaces including preparation over a coat of red oxide primer.
M&L for two coat of Cement base paint over a coat of cement primer on new surface of wall including preparation complete.
M&L for Cement Concrete in CM 1:3:6 type C1 as in plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed
Provision of RCC Septic tank for 50 user of size (5000X1800mm), depth designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls 150mm thick with (12mm dia main bar @150 c/c and 10mm dia distribution bar 200 c/c), Base Slab 150mm thick with (12mm dia bar @150 c/c both ways), Baffle walls (150mm thick) and Roof Slab 125mm thick with (10mm dia main bar @150 c/c and 8mm dia distribution bar 200 c/c) including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth exceeding 1.5 meter and overall depth of 3 meter including combined, screen chamber (1200x600) and intercepting chamber as per Drg No TD/750 dt 21.03.18 Sh 1/2 & 2/2 uploaded herewith.
Provision of Soakage wells complete as per Drg No DZ-1124 R Sh 1/1 dt 12.02.03 1.2m dia and 3.0 m depth ,Soakage wells excavation, in any soft/ loose soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size
M&L for removing excavated soil to a distance upto 20 km at dumping ground as per MCD & NGT norms complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed stoneware)/pvc set in cement mortar 150 mm internal dia of pipe complete all as specified and directed.
S&F Salt glazed stone ware pipes laid and jointed complete with collars ware drain pipes laid in trenches and jointed internal dia of pipe150 mm complete all as specified and directed.
M&L cement mortar concrete bed to drain pipes in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone agg) incl packing under, and haunching against the sides of of pipe 150 mm dia complete all as specified and directed.
Demolition of brick work built in cement mortar of any description complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved on plan not exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in subbase, foundation, filling & mass concrete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone agg) as in coping,sides of paver blocks, sides of chequered tiles, benching, manhole channel etc incl form work as required complete all as specified and directed.
M&L rendering 15mm thick in cement mortar 1:4 on fair faces of brick surfaces of walls finished the surface fair and even without using extra cement complete all as specified and directed.
Surface dressing n exc 15 cm deep complete in soft / loose soil.
S&F 110mm bore PVC (SWR) pipe single socketed, in any length laid in trenches or in floor/ under footpath with rubber ring joint, ISI marked complete
M&L Hardcore with broken stone or boulders of gauge n exc 63mm deposited, spread and levelled in layers, watered and rolled/ rammed to a true complete
M&L 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in sub base.
S&F Kerb stone of size 300x450mm & 150mm thick precasted with plain cement concrete type B0, 1:2:4, (using 12.5mm graded crushed stone aggregate) including laying / insert with CM 1:4 including necessary earth work for laying kerb stones complete.
M&L for preparation of new of perviously untreated surfaces of Kerb Stone and applying two coat of synthetic enamel paint over one coat of water based primer on Kerb Stone complete all as specified and as directed.
S&F mild steel TMT bars 10 mm dia and over cut to length,bent to shape required,incl cranking,bending and binding with and incl mild steel wire (annealed) not less than 0.9mm dia complete all as spd.
All as per item 36 here-in-before but 8mm dia as in stirrups,spacer and binders
M&L for Form wk to sides of concrete foundation, footings bases of columns, raft and raft beams, sides and soffit of foundfation and similar work; vertical or to batter
M&L for Form wk to sides of pillars, posts,struts, piers, columns and stanchions for fair finshed surface.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail?ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n. exc 20cm wide.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping).
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for RCC 1:1.5:3 (20mm graded aggregate) as in foundations, including rafts footings,bases for columns etc
M&L for RCC 1:1.5:3 (20mm graded aggregate) in columns,pillars, piers, posts and struts .
M & L reinforced cement concrete design mix 1:1.5:3 (20 mm graded aggregate) as in slab supported on walls or as in shelves etc all as specified.
M & L reinforced cement concrete design mix 1:1.5:3 (20 mm graded aggregate) as Beams, cantilevers, bressummers, lintels over 1.5m span
M&L Cement concrete type B-1, 1:2:4 (20mm graded aggregate) 40mm thick in floors and finishing cement concrete surface even and smooth without using extra cement all as specified.
M&L rendering 5mm thick in cement mortar 1:3 finished even and fair on ceilling surfaces complete all as specified.
M&L for 5mm thick Rendering on concrete surface in CM 1:3 finished even and fair complete all as spd.
M&L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 white cement: 1/2 coarse sand : 2 white marble stone chipping 10mm nominal size with colour compound) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and as directed. (Note: Payment for providing grooves shall be made separately).
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed.
S&F Bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required: hooks(stay), heavy, for large gates; hook and pintle hinges; large hasp and staples; chains; hand made sliding bolts; clamps; hold fasts wall ties; hooksfor hanging fan; plain angle cleats for securing purlins to wood trusses or rafter; knee piece insert; two way and three way strap; plate washers and similar small articles conforming to Fe-290 Gde-E-165
S&F 4 mm thick Aluminium Composite Panel cladding of approved quality and colour as approved by GE, fixing in MS frame at any height and including MS frame of size not exc 0.36 sqm (used in rect angular tubes of size 50.8mm x 25.4mm x 2.9mm thick or square tubes 38 mm x 38 mm x 2.9mm thick are used in frame) and filling the joints with all weather silicon sealant including all mouldings, cuttings, etc including fixing of 3D ACRYLIC LETTER not less than 6 inch in height and 25mm in thickness upto 60 Nos in English and Hindi including 2 x logo both sides at top front of the gate complete all as specified and directed by Engineer-in-Charge. (Make - ACP Aluedecor, Alstrong, Wonder Alu Board Overseas, VIVA , Eurobond.
S&F Anodised aluminium frame powder coating of any colour (Thickness of powder coating not less than 50 micron), for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F Anodised aluminium window and ventilator shutters, powder coating of any colour (Thickness of powder coating not less than 50 micron), side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21100mm long (2 No.) suitable handle (1 No.) and including 4.80mm thick glass complete all as specified
S&F anodised aluminium door shutters, powder coating of any colour (Thickness of powder coating not less than 50 micron) aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc and including 4.80mm thick glass complete.
M&L 20 mm thick Granite (of any type/ any colour) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including15mm thick rendering in CM 1:4 complete.
M&L for roof treatment with polymeric membrance (APP based) with non woven polyster mat as reinforcement with following:- (a) M&L for cleaning the new plastered surface and providing & laying a coat of cold applied bitumen 85/25 based primer on entire surface @ 0.40 Ltr/Sqm on dry and clean surface. (b) M&L for providing & laying APP based polymeric membrane of 3 mm thickness of weight of 4.0 Kg/Sqm with non woven polyster fibre as reinforcement on primed surface by torch application with 15 cm end over laps & 10 cm side over laps (overlaps to be thermo fused by flame) and applying one coat of hot blown bitumen 85/25 @ 0.70 Kg/Sqm all as directed. Notes: (1) The work shall be executed through authorised applicator of manufacturer only. (2) Authrised Applicator shall be approved by GE before starting of work. (3) All materials shall be procured directly form manufacturer. (4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Ten years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor’s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer.
M&L for Two coat of Aluminium paint over a coat of aluminium primer on APP membrance any description, over 10cm in width or girth,not otherwise described complete all as specified and directed.
M&L for preparing the newly plastered wall surface then applying 2mm thick wall care putty followed by two coat of oil bound distemper over one coat of interior primer complete all as specified and directed.
Earthing complete with galvanised steel plate electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level , connected to and including galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, washers protected by and including 15 mm bore GI Pipe “light grade” and connected to main test point as directed and including concrete pit in PCC(1:3:6) type C1 precast RCC M-25 (design mix) precast cover slab (54 x 54 x 5 cm) duly reinforced with and including 8 mm dia TMT steel bars @ 150 mm C/C both way, one lifting handle made of 8 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI medium grade pipe for watering, charcoal and salt in alternate layers, including necessary excavation and earth work any type of soil complete all as specified and shown in electrical plate No. 5 of SSR Part-I including testing on completion complete all as specified and directed.
S & F distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed.
S & F MCB DP 40 Amp complete all as specified and directed.
S & F MCB SP 5 to 32 Amp complete all as specified and directed.
S&F in replacement sub main wiring with 2 runs of 10 Sqmm FR single core PVC insulated & unsheathed cable, 1100 Volts grade with multi stranded copper conductor drawn through and including 20 mm dia concealed PVC rigid non metallic conduit medium grade as per IS with all fittings and one run of 10 Sqmm FR PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
Supply and fixing of MS Stand as per OEM Recommendation and Placing of Outdour Unit on MS Stand of C Channel.
Supply, installation, testing & commissioning of tower AC 4.0 TR capacity, Air conditioner is electric driven, three phase, charged with Eco friendly regrigerent comes with special health filter with all connected accessories, including connection of copper piping from indoor to outdoor unit, making of hole in any type of wall, including connection of PVC drain pipe from indoor to outdoor unit, fixing of wall mounted / floor mounted stand for indoor unit and outdoor unit flexible PVC caseing pipe minimum 40mm dia covered on all exposed insulated copper pipe line and PVC wire etc complete all as specified and as directed by Engr-in-Charge. (Note: Copper pipe, wiring, drain pipe shall be measured and paid separately under the relevent items of this Schedule as supply only. (Make: Voltas/ Carrier Midea/ Blue Star or equivalent)
Supply only copper pipe of 5/8" size for inlet and outlet with nitrile insulation complete.
Supply only copper pipe of 3/8" size for inlet and outlet with nitrile insulation complete.
Supply only PVC drain pipe flexible type of suitable size as per requirement complete.
Supply only PVC drain pipe Hard type of suitable size as per requirement complete.
Supply only of electric cable, XLPE insulated, unarmoured, 1100 volts grade with stranded copper conductor of size 4.00 sqmm 4 core complete.
S&F MCB TPN, C curve, 415 volts 40 Amps complete.
S&F MCB TPN, C curve, 415 volts 63 Amps complete.
S&F FP sheet metal enclosure, metal type, suitable for provn of fixing of MCB TPN complete
S&F in replacement sub main wiring with 2 runs of 6 Sqmm FR single core PVC insulated & unsheathed cable, 1100 Volts grade with multi stranded copper conductor drawn through and including 20 mm dia concealed PVC rigid non metallic conduit medium grade as per IS with all fittings and one run of 6 Sqmm FR PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F MCB TPN, C curve, 415 volts 100 Amps complete. (Make: Indo Asian/ Legrand/ Havells/ L&T/Schenider)
S&F TPN DB 4 way, double door (CRCA sheet) metal type dust and vermin proof, TPN 4 way with 100 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, flush to wall complete.
S&F in replacement sub main wiring with 2 runs of 25 Sqmm FR single core PVC insulated & unsheathed cable, 1100 Volts grade with multi stranded copper conductor drawn through and including 32 mm dia concealed PVC rigid non metallic conduit medium grade as per IS with all fittings and one run of 25 Sqmm FR PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
Supply and installation of air cooled inverter based split AC unit with cooling functions, Air conditioner is electric driven single phase of capacity 2.0 TR, minimum 3 star rating with charged with Eco friendly refrigerent and comes with special health filter and all connected accessories and fixing of copper pipe & cable from indoor to outdoor and making of hole in any type of wall, icluding PVC drain pipe from indoor unit, Outdoor split AC hanging wall mounted / floor mounted stand and flexible PVC pipe minimum 40mm dia covered on all exposed copper insulated pipe line and PVC wire etc complete. (Note: Copper pipe, wiring, drain pipe shall be measured and paid separately under the relevent items of this Schedule as supply only. (Make: Hitachi/ Mitsubushi/ Daikin/ Blue Star)
Supply only copper pipe of 1/4" size as per requirement for inlet and outlet with nitrile insulation complete.
Supply only copper pipe of 1/2" size as per requirement for inlet and outlet with nitrile insulation complete.
Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +2.5% and capacity 5 KVA. (Make: V gaurd/ Bluebird/ Volina)
Supply and fixing sheet metal enclosure with socket plug top, single pole and neutral enclosure with a two pin earth and socket complete with one MCB of capacity 25 Amps, 240 Volts complete.
Material and labour of point wiring complete with 1.5 Sq mm (nominal area) FRLS PVC insulated sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and fittings such as tees, bends, elbow and 1.5Sqmm FRLS PVC insulated unsheathed copper conductor mulistranded earth wire, connecting to common earth dolly including Metal Flush Box, Cover plate with frame, cutting chases and making good disturbed surface in CM 1:3 to match with existing surface for one light bell/ fan point control by one way switch.
All as per item No. 87 here-in-before but point wiring with 2.5 Sqmm cable.
S&F modular switch, 1 way, 6 Amp, 1 Module, complete all as specified and as directed.
S&F modular Socket, 16/6 Amp, 3/5 Pin, combined, 2 module complete all as specified and as directed.
S&F modular switch, 1 way, 16 Amp, 1 Module, complete all as specified and as directed.
S&F sub main wiring with 2 runs of 10 Sqmm FR single core PVC insulated & unsheathed cable, 1100 Volts grade with multi stranded copper conductor drawn through and including 20 mm dia concealed PVC rigid non metallic conduit medium grade as per IS with all fittings and one run of 10 Sqmm FR PVC insulated copper conductor including cutting chases and making good in CM 1:3 to match with existing surfaces complete all as specified and as directed. Note:- (Two run of cable along with earth conductor including PVC rigid conduit shall be measured as one RM length).
S&F Ceiling rose, PVC/ polycarbonate, isolated body type, three terminal, 240 volt, fixed in position & connecting complete all as specified and as directed.
S&F Bldg security light fitting LED 25 Watt, highly efficient IP66 LED, high power having aluminium pressure die cast housing and PC cover in the front and high power lens for batwing light distribution with beam angle of 120 degree used to enhance the luman output Height with Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 4 KV lumen Efficiency should ≥ 100 lumen/ watt in Cool day Light(5700K), Power factor>0.9, CRI (Ra) >70, System with Average life of 50000 Burning hours completewith electric connection with suitable size of PVC insulated copper wire including GI bracket 1.5 Mtr light grade 32 mm dia with clamps and bolts complete all as specified and directed.
Supply, fixing and connecting recessed mounting Ultra slim Round LED Down light 12 watt designed white colour,with excellent thermally managed aluminum pressure die cast housing with heat - dissipating fins for large surface area finished in epoxy powder coated , deliver high efficacy light complete with all accessories all as specified and as directed.
Supply, fixing and connecting of Slim LED Batten 20 watt with Surface/Wall Mounted integrated LED 4 feet Fitting Polycarbonate housing and diffuser with viewing angle of 120 degree used to enhance the luman output Height suitable for White Housing & Isolated Electronic Driver, with Output Short-circuit protection, Surge Voltage protection up to 2.5 KV . lumen Efficiency should ≥ 100 lumen/ watt in Cool day Light(6500K), Power factor>0.9, CRI (Ra) >80, System with Average life of 50000 Burning hours complete with all accessories as required complete all as specified and as directed.
Supply & fixing in replacement BLDC ceiling fan complete with blades, down rods, electronic regulator and accessories , Min air delivery 210 CFM with service value 6.00 BEE , 5 star rating (White colour) 230 V, 1200 mm sweep, speed 340 RPM, having rod length 300 mm complete all as specified and directed by Engr in charge.
S&F modular Fan regulator suitable for BLDC fan , 120W - 2 module complete all as specified and as directed.
S & F distribution board double door type, SPN, 8 way, complete including 200 Amps rated bus bar, neutral link, blanking plates etc complete all as specified and directed.
S & F MCB SPN, 240 Volts, 63 Amps complete all as specified and directed.
M/S Rohit Enterprises (BID ID -3274318)
ASHUTOSH BUILDERS (BID ID -3274424)
M/s Durga Traders (BID ID -3272414)
Vishal Traders (BID ID -3277527)
J.P. Enterprises (BID ID -3277661)
Akhil Enterprises (BID ID -3274406)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .