| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.6 LAccepted-Finance | L1 | Accepted-Finance Quoting Lowest rate | |
| 2 | L2₹22.7 L+₹19,064 (0.85%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-Finance Quoting Higher rate | |
| 3 | L3₹26.8 L+₹4.3 L (18.8%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | L3 | Rejected-Finance Quoting Higher rate |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Jul 2021, 3:00 pmClosed
Superintending Engineer, Western El
Office of the Superintending Engineer, Western Electrical Circle , PWD, Purta Bhavan, 1st floor, Burdwan-713103
Up-gradation of Dhaniakhali Rural Hospital from 30 beds to 100 bedded SGH -Arrangement of Fire-Detection system
2021_WBPWD_336787_1
WBPWD/SEWEC /HED /NIQ-03/2021-22 _2nd call
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Dhaniakhali
Please refer Tender documents.
4 documents required · 4 mandatory
₹50,000
Yes
Office of the Superintending Engineer, Western Ele
4 Aug 2021
16 Jul 2021
30 Jul 2021
16 Jul 2021
28 Jul 2021
20 Jul 2021
16 Jul 2021 - 19 Jul 2021
19 Jul 2021
Amount
Supply, installation, testing & commissioning of Microprocessor based Intelligent Addressable 2 loop Main Fire Alarm Panel in strict compliance with the Technical specification and schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Microprocessor based Intelligent Addressable 4 loop Main Fire Alarm Panel in strict compliance with the Technical specification and schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Addressable Optical-Thermal Multi-criteria Detector in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Intelligent Analog Addressable Heat Detector in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, Installation, Testing & Commissioning of Response Indicator with all other accessories in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Intelligent addressable manual call point in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Intelligent addressable loop powered sounder in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, installation, testing & commissioning of Intelligent addressable Input & output Module in strict compliance with the (i) Technical specification & Installation guidelines and (ii) schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively (Make:- Honeywell / Siemens/ Securiton/Edward/Bosch/Jhonson Control as approved by E.I.C)
Supply, Installation, Testing & commissioning of of 7AH - 12 Volt DC battery for standby power supply system for Main FACP in strict compliance with the Technical specification and schedule of Inspection, testing & Commissioning as depicted in attached separate sheet as Appendix-I & Appendix-II respectively. (Make: Exide\Amaron/APC)
Supply, Installation, Testing & Commissioning of 120Watt digital Power Amplifier & gooseneck microphone. (Make: Honeywell/ Siemens/ Bosch/Ahuja/Siemens as approved by E.I.C)
Supply, Installation, Testing & Commissioning of 6 Watt Ceiling Mounted Speaker in ABS enclosure complete with all necessary Accessories . (Make: Honeywell/ Siemens/ Bosch/Ahuja/Siemens as approved by E.I.C)
Supply, Installation, Testing & Commissioning of 6 Zone, Voice Alarm controller with Gooseneck Microphone,USB, MP3, AM/FM player with 8 zone button paging station and having seamless integration facility with main fire alarm panel for voice evacuation complete as required (Make: Honeywell/ Siemens/Bosch or other equivalent make as approved by E.I.C)
Supplying & laying of 2x1.5 sqmm FRLS shielded copper Conductor stranded cables in red/black color and generally confirming to IS-694-2010 and meet the signal cabling requirements (Make-Gloster/KEI/Finolex/Polycab as approved by E.I.C)
S & F 20mm PVC rigid FR conduit (Precision make) on wall with saddles as per GS [ 7(a)/ E- 16 ].
Note:- The successful Bidder is required to submit the General Arrangement drawings[both soft copy(Auto-cad/PDF) & HARD COPY] of the equipments/components like Detectors, R.I, MCP, FACP, PA/sound systems etc. in the building plan drawing with complete dimensions. Respective/relative distances etc. within 7 days from the Award of contract for approval of E.I.C before commencement of work.
TAPAN KUMAR SARKAR
GLYPTIC
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .