Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC Being overall reasonable | |
| 2 | L2₹31.0 L+₹271 (<0.01%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹37.7 L+₹6.7 L (21.7%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹37.8 L+₹6.8 L (22.0%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹39.4 L+₹8.4 L (27.1%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹44.3 L
EMD Value
₹88,560
Closing Date
16 Oct 2020, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
REPAIRS TO LEAKAGE SEEPAGE OF ROOFS FALSE CEILING TOILET PATH DRAIN AND WELCOME MAINT TO OFFRS MD ACCN AND PERIODICAL SERVICES TO JCOS ORS MD OTM ACCN AT DUNKRIK LINE IN AGE BR P UNDER GE C KIRKEE
2020_MES_378999_1
8396/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹88,560
Yes
17 Nov 2020
19 Sept 2020
17 Oct 2020
19 Sept 2020
16 Oct 2020
3 Oct 2020
19 Sept 2020 - 2 Oct 2020
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exc. 1.5 sqm but n exc 4 sqm each and removing from site.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc. 1.5 sqm each and removing from site.
S & F Pressed steel door frame of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate, including PCC 1:2:4 filled in hollow portion of frame etc, complete all as specified.
S & F Pressed steel door frame of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hings, lock strike plate, etc, complete all as specified.
S & F 35mm thick IInd class HW glazed and skelton shutter,open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc size of shutters as specified in SSR-I, Section 8.24(a) supplied and fitted to chawkats.
S&F 35mm thick plain framed, panelled shutter (one panel) Factory made without interlocking rail and panel of 9mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed by Engr-in-Charge.
S&F for aluminium anodized three track sliding window with two or more shutter with 4mm thick plane glass, one shutter of stainless steel mosquito proofing with good quality bearing, handle lock, etc rubber beading and glazing clips etc complete all as specified and directed.
S & F Factory Made Solid PVC Moulded Door Shutter with flush door core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm prelam PVC sheet on back face, supplying & fixing in frame at site all as specified and as directed by Engr-in-Charge.
M & L for vitrified tiles, 9-10 mm thick (square / rectangular), polished, combination of light & dark shade (Approx 20% dark shade), area of each tiles exceeding 0.18sqm but not exceeding 0.36 Sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match the tiles including 15mm thick screed bed in cement mortar (1:6) including demolition of floor or wall tiles of any description or thickness laid, bedded and pointed in any mortar and removing the debris off the MoD land.
All as per item No 9.00 above but in vertifical surfaces set and jointed in neat cement slurry and pointed in coloured cement to match the shade over and including 10mm thick rendering backing coat in cement mortar (1:4).
M & L for Non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors etc. set in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) including demolition of floor or wall tiles, and removing the debris off the MoD land all as specified and directed.
M & L for Non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc. set in neat cement slurry and pointed in coloured cement to match coloured tiles over and including 15mm thick screed bed in CM (1:6) including demolition of floor or wall tiles, and removing the debris off the MoD land all as specified and directed.
M&L for coloured ceramic tiles 600mm x 600mm x7 -8mm thick, in floors set and jointed in neat cement slurry and pointed in white /colour cement to match the shade with and including 15 mm thick screed bed in cement morter 1:6 including demolition of floor or wall tiles, and removing the debris off the MoD land all as specified and directed.
M & L for glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick approved set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10 mm thick backing coat in CM (1:4) including demolition of floor or wall tiles, and removing the debris off the MoD land all as specified and directed.
S&F butt hinges medium weight cold rolled mild steel 100mm long.
S&F in repairs aluminium anodised barrel tower bolts of extruded section 100mm long.
S&F in repairs aluminium alloy, anodised, sliding door bolt with hasp, staple and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 300mm long.
S&F aluminium alloy anodised handle, cast type 200mm long.
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples including necessary beading all as directed by Engr-in-Charge.
S&F in repair Aluminium, anodised, barrel tower bolts of extruded section length of bolt 150 mm complete all as specified.
S&F in repair Mild steel pressed handles, oval type, stove enamelled black of size 150 mm all as specified and directed.
S&F in repair vitreous china Squatting pan white orissa pattern size 580x440mm with integral foot rests (Excluding flushing cistern & flush pipe) with 100mm dia cast iron P trap incl lime concrete bedding and making good the disturbed portion to match with the existing surface of floor.
S&F in repair vitreous china wash basin white flat back size 580x450 mm excluding taps but incl 32 mm dia CP waste fitting and PVC waste pipe 610 mm long and brackets.
S&F in repairs Vitreous China wash down water closet pan (EWC), white (Excluding flushing cistern & flush pipe) with 100mm dia cast iron P trap incl lime concrete bedding and making good the disturbed portion to match with the existing surface of floor.
S&F in repairs 15mm dia bore chromium plated bib taps long body with capstan head handle with cup , screwed down, screwed for iron pipe or brass ferrule complete.
S&F in repairs shower rose size 125 mm chromium plated with or without swivel joints, including fixing to 15 mm dia steel pipe or union complete all as specified and directed.
S&F in Repair wall mixture three in one with complete accessories (Make - Hindware, CERA) complete all as specified and directed.
S&F for 15mm GI tubing medium grade, with all fittings fixed to walls and ceiling or laid in floors incl cutting through walls, floors etc incl taking down the same in repairs all as specified.
M&L for preparing of old plastered or unplastered surfaces of walls including brooming down or scrapping down with steel wire brushes, smoke , soot , moulds, moss effloresent salts and trading oil and greasy spots and applying one coats of oil emulsion distemper (white/any tint as directed) on walls complete all as specified and directed.
Complete removing existing treatment and applying two coats of oil emulsion distemper (white/any tint as directed) on walls over a coat of Bilra white putty complete all as specified and directed.
M&L for preparing of old plastered or unplastered surfaces of walls including brooming down or scrapping down with steel wire brushes, smoke, soot, moulds, moss effloresent salts and trading oil and greasy spots and applying one coat of dry distemper (white/any tint as directed) on walls complete all as specified and directed.
M&L for preparing of old plastered or unplastered surfaces of walls including brooming down or scrapping down with steel wire brushes, smoke, soot, moulds, moss effloresent salts and trading oil and greasy spots and and applying two coat of cement based paint (white/any tint as directed) on walls complete all as specified and directed.
M&L for preperation of newly plastered or previously untreated surfaces of wall and applying two coats of acrylic emulsion exterior grade weather proof acrylic emulsion antifungal and anti algae (Antifungal) paint over one coat of primer all as speicifed and directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint any tint all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint any tint all as specified and directed.
M&L for preparation of new steel surfaces and priming with red oxide of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint any tint all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp insulation, Ac etc), any thickness including cover fillets complete.
M&L for false ceiling including 12 mm thick perforated Gypsum board pre painted / plastic coated, finish granular surfaces fixed on and including GI powder coated frame work of grid of size 0.60 x 0.60m consisting of GI angle supports on wall of size 19mm x 19mm x 0.7mm fixed to wall with appropriate size dash fasteners at 1m centre and main Tee of size 24mm x 32mm x 0.70mm and crossTee of size 24mm x 32mm x 0.70 mm using purpose made members interlocking into each other and suspended from the roof by using GI hanger wire of dia 2.68 mm of adequate lenght with adjustable hook clips of 3.5 mm dia wire to be used with main runner etc all as per manufacturer's instruction all as specified and directed. Make of GI grid work and ceiling board : "Armstrong or equivalent approved make by Accepting Officer" .
Removing of old water proofing treatment and cleaning the surface of slab with wire brushes, removing dust, foreign material, rubbish off the site to a distance n.exc. 100m complete all as specified and directed.
M&L for Coving / Filleting in any position and in any shape in cement mortar 1:4 n.exc 25 sqcm including, all mitres, stops, etc complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% mixed with by weight of cement finishing even and smooth to receive water proofing treatment complete without using extra cement all as specified and directed by Engineer-in-Charge. Note : WPC shall be measured and paid separately.
M&L for water proofing treatment over RCC slab by applying oil based bituminous primer surface @0.25 Kg/sqm and laying 3mm thik APP modified water proofing polymeric membrane with 100 mm side and end lap having weight not less than 3.50 kg/ sqm , reinforced with non-woven polyster reinforced matt weighing not less than 160 gms/sqm polyster core having soften point not less than 1500C, longitudinal tensile strength not less than 650 N/5cm, by torching method and applying a coat of solar reflective aluminium paint @ 0.15 Kg/Sqm on membrance surface including 24 hrs ponding test complete all as specified and as directed by the Engr-in Charge.complete all as specified and as directed by the Engr-in Charge.
Supply only integral water proofing compound
S&F in repairs tubes 20mm bore medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid in floor etc complete all as specified.
S&F in repairs rotational moulded polyethylene water storage tanks 500 ltrs capacity, double layered (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
M&L for sunken flooring as per following details (a) Special treatment to toilet floor by demolition of existing treatment of any description and thickness, removal rubbish outside MD land.(b) Clean the sunken portion of toilet / Bath / WC / Kitchen throughly to remove laitance, dirt dust, etc.(c) Form angle fillet of size 40mm x 40mm along the junction of wall and floor using polymer modified mortar ("Dr Fixit" Pidicrete URP" or equivalent.)(d) Sanitary pipes entering through walls and floor shall be sealed with "Dr Fixit Bathseal Tape" and the gaps to be grouted with non-shrink cementitous grout "Dr Fixit Bathseal Grout" or equivalent. Nahani Traps, etc to be fitted securely and the gaps around it to be grouted in the same manner.(e) Apply one coat of a Bitumen-modified polymer coating "Dr Fixit Bathseal Plus" or equivalent on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely.(f) In the remaining area, in dry sustrate condition brush apply first coat of the same coating and further apply second coat when first coat is dry. Extend the coating upto 150mm above the FFL. Above FFL, another cementitious waterproofing coating "Dr FixitPidifin 2K" or equivalent can be furthr applied right upto 2.10 mm to water proof the shower area also, it is a bathroom or bath cubicles of a sanitary annes and apply second coat after 6-8 hours and allow to dry completely.(g) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M-15 type B0 mixed with intergral WPC (Liquid) laid to be slope 1:60 towards outer face of wall. Provide 40mm OD UPVC pipe at the lowest point with 300mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2 etc complete all as per manufacturers instruction and direction.
Disconnecting existing tanks, exc 250&n.exc 500 ltr capacity setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position after water proofing treatment to the roof complete all as specified and directed.
Fixing of PVC 40 mm dia for spout pipe in sunken floor complete.
M & L for Glazed ceramic coloured tiles 300x200mm and standard thickness as provided by the manufactures in Dado/Skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over 10 mm thick backing coat in CM (1:4) including demolition of floor or wall tiles, and removing the debris off the MoD land all as specified and directed.
S&F in repairs for 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets.
S&F in repairs vitreous china WHB, size 550 mm X 400 mm make:- Parryware (flat back or angle back type) including cutting for and pinning in ends of brackets or erecting stand etc but excluding fixing of supply and waste pipe complete.
S&F for PVC connection 15 mm dia with PTMT nuts of length 600 mm long complete.
S&F in repair for stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with capstan head handle , screwed both ends for iron pipe or for unions, with long shank and cup (concealed type) , bore dia 15 mm complete.
N AND G CONSTRUCTION
M/S JAYCONSTRUCTION CO
M/S OMSAI ENTERPRISES
V.R.PRAJAPATI AND CO.
C J Enterprises
greenstone construction
S.R.M.K Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .