Chief Engineer and Head, TSD
Chief Engineer and Head, Technical Services Division, BARC, Trombay, Mumbai-400085
Annual Maintenance Contract with Miscellaneous works of Central Air Conditioning Plant and Ventilation System at HBNI Building, Anushaktinagar, Mumbai - 400 094.
2022_BARC_698262_1
BARC/TSD/56/2022-23
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
547 days
HBNI Building Anushakti Nagar Mumbai
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1.2 L
R No 1423, TSH Anushaktinagar Mumbai-400094
30 Aug 2022
6 Jul 2022
29 Jul 2022
6 Jul 2022
27 Jul 2022
6 Jul 2022
6 Jul 2022 - 27 Jul 2022
18 Jul 2022
Amount
Quarterly maintenance of water cooled screw chillers capacity of 350 TR through OEM(Original Equipment Manufacture)as per technical specification.(3 Sets x 6 Quarter)
Quarterly maintenance of centrifugal pumps as per technical specifications.(6 Sets x 6 Quarter)
Quarterly maintenance of induced draft cooling towers capacity of 500 TR as per technical specifications.(3 Sets x 6 Quarter)
Quarterly maintenance of water softening plant capacity of 7 CMH along with pump & motor as per technical specifications.(2 Sets x 6 Quarter)
Quarterly maintenance of various capacity of AHUs as per technical specifications. (9 Sets x 6 Quarter)
Quarterly maintenance of 1.5 TR capacity fan coil units as per technical specifications.(264 Sets x 6 Quarter)
Quarterly maintenance of kitchen exhust blowers as per technical specifications.(3 Sets x 6 Quarter)
Quarterly maintenance of precision air conditioning units capacity of 17 TR as per technical specifications.(4 Sets x 6 Quarter)
Quarterly maintenance of precision air conditioning unit capacity of 25 TR as per technical specifications.(1 Set x 6 Quarter)
De-scaling of chiller evaporator tube for 350 TR capacity water cooled screw chillers as per of technical specifications.
De-scaling of chiller condender tube for 350 TR capacity water cooled screw chillers as per of technical specifications.
1 1/2 yearly maintenance of centrifugal pumps as per technical specifications.(6 Sets x 1 1/2 year)
1 1/2yearly maintenanceof various capacity of AHUs as per technical specifications.(9 Sets x 1 1/2 year)
Supply and installation of stem type thermometer and thermowell in SS as per tender specification
Supply and Installation of salt as per sample / suggestion by EIC as per technical specifications.
Supply and installation of 1.5 TR capacity FCU motor as per technical specifications.
Supply and installation of capacitor suitable to 1.5 TR capacity FCU as per technical specifications.
Supply and installation of step(speed) regulator suitable to 1.5 TR capacity FCU as per technical specifications.
Supply, installation, testing & commissioning of PCB card with programming suitable to 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications.
Supply, installation, testing & commissioning of Display with key pad suitable to 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications.
Supply and installation of electrical contactor with auxiliary contactor 32A /15KW, 415V suitable for 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per technical specifications.
Supply and installation of electrical relay with base 10 Amps 9 VDC suitable for 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS. as per technical specifications.
Supply and installation of electrical relay with base 10 Amps 24 VAC 88 Ώ suitable for 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFS as per clause no 14 of technical specifications.
Supply and installation of space heater suitable for scroll compressor of 17 TR Blue Star make precision air conditioning (PAC) unit Model No. PCX 632 DTS/UFSas per technical specifications.
Mechanical shaft seal for Maxflow make pump of capacity 225 CMH and 40 mtr Head of WC.
Mechanical shaft seal for Maxflow make pump of capacity 300 CMH and 30 mtr Head of WC.
Mechanical shaft seal for Kirloskar make pump of capacity 225 CMH and 40 mtr Head of WC.
Mechanical shaft seal for Maxflow make pump of capacity 300 CMH and 30 mtr Head of WC.
PVC flexible canvas with 2 mm thick for Fan Coil Unit, AHU and Exhaust system as per technical specifications.
Painting of MS pipeline/supports of various sizes and painting of chilled water pipeline of various sizes with two coat of primer & two coats of synthetic enamel paint as per technical specifications.
Fabrication of MS item for supports and structures as per site reuqirement as per technical specifications.
Replacement of old/defective Aluminum powder coated air grilles/diffusers with/without volume control dampers as per technical specifications.
Modification in GI ducting along with necessary fittings, supports etc as per technical specifications for 20 G (1.0 mm)
Modification in GI ducting along with necessary fittings, supports etc as per technical specifications for 22 G (0.8 mm)
Aluminium clading with 26G thick Al sheet as per technical specifications.
Supply and Installation of 25 mm thick nitrile rubber insulation as per technical specifications.
Supply, Installation, Testing and Commissioning of aluminium impeller suitable to 1.5 TR FCU installed at HBNI building as per technical specifications.
Supply, Installation, Testing and Commissioning of electronics timer as per technical specifications.
Removal of old damaged window AC and providing window AC of 1.5 TR as per specification
Removal of old damaged split AC and providing split AC of 1.5 TR as per specification
Supply, Installation, Testing and Commissioning of dispay with key pad of 350 TR chiller machine ( Diakin make)as per technical specifications.
Supply, Installation, Testing and Commissioning of Pin type 2 way valve ½ “ PN 16 to install in supply line of FCU as per specification
Supply, Installation, Testing and Commissioning of 5/8” sleeve insulation nitire rubber as per specification
Supply, Installation, Testing and Commissioning of 2 Way Valve 25 mm dia in FCU Connection line
Supply, Installation, Testing and Commissioning of M.S. Fan motor stand for FCU as per sample
Supply, installation, testing & commissioning of temperature sensor MCS-T100-40 suitable to blue star make water cooled screw chiller capacity of 350 TR as per technical specifications.
Supply, installation, testing & commissioning of Expansion valve for blue star Chiller machine 350 TR, SPORLAN,SHE-175 10-S
Supply, installation, testing & commissioning of Chiller plant no.3 3 phase motor overload relay model 3UA61 40-3J 110-135A
Supply, installation, testing & commissioning of 25 TR Precision unit Cond fan with motor
Supply and installation of Softening plant PVC Valve Replacemen with new one as per specification.
Supply and installation of Softening plant NRV Replacemen with new NRV specification.
Supply and Installation of HDPE Filter of FCU as per specification.
Supply and Installation of Purging valve25 mm dia GM gate valve.
SPEEDFROST SERVICES PVT LTD
Bluestar Limited
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .