Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.7 CrAccepted-AOC | ₹3.7 Cr | 1 | Accepted-AOC Awarded Ist Lowest |
| 2 | 2₹4.1 Cr+₹41.9 L (11.4%)Rejected-AOC | ₹4.1 Cr+₹41.9 L (11.4%) | 2 | Rejected-AOC 2nd lowest |
Tender Value
₹3.7 Cr
EMD Value
₹7.4 L
Closing Date
12 Feb 2020, 3:00 pmClosed
Balvinder Nain
PHED Fatehabad
Renovation Augmentation of Water Supply Scheme Nehla Tehsil District Fatehabad Design Constructuion Testing commissioning of 1.00 MLD Water Treatment Plant at Old Water Works Aug of old Water Works and Construction of 2nd Water Works all
2019_HRY_114009_1
NEHLA 123032 DT. 13.12.2019 369.28 LAKH
Open Limited
Civil Works
Works
540 days
Fatehabad Nehla
Please refer Tender documents.
2 documents required · 2 mandatory
₹15,000
Yes
Engineer in Chief
₹7.4 L
Yes
18 Feb 2020
22 Jan 2020
12 Feb 2020
22 Jan 2020
12 Feb 2020
22 Jan 2020
Amount
N.S. Item
Desinging, Testing, Commissioning of automated PLC controlled SCADA based water purification plant of 1.00 MLD capacity at Old Water Works Nehla, all other installation etc. comprising of DI pipe from raw water main/pump, inlet box of WTP and to CWT to C.W. suction well, inlet channel, Alum dozing, Flash mixing, Clari floculator, filter box, over head Reservoir for back wash including pump sets and electric control panel, waste water tank including pump sets and electric control panel, DI pipes, DI specials, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of floe measurement and sand bed with automation complete in all respects as per NIT (Sluice valve of make IVC/ VAG ) Pumping Machinery I ) RAW WATER PUMP SETS
Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame a) RAW WATER PUMPING at Old Water works 500 LPM 12 M. Head
b) OLD WATER WORKS Nehla 800 LPM 40 M. Head for Zone No.1
400 LPM 30 M. Head for Zone No.2 (B/STN Kandulpath)
400 LPM 30 M. Head for Zone No.3 (B/STN Ambedhkar)
C) 2ND WATER WORKS Nehla 800 LPM 40 M. Head For Zone No.4
400 LPM 30 M. Head For Zone No.5 & 7
400 LPM 30 M. Head For Zone No.6
d) Boosting Stations 500 LPM 40 M. Head For Zone No.2 & 3
400 LPM 30 M. Head For Zone No.5, 6 & 7
Supply & fixing following CI D/F pipe and special/ sluice valve/ non return valves/ bell mouth / reflux valve including cost of jointing materials, excavation, laying jointing refilling including making adequate supports of masonry/ concrete steel for delivery and suction pipe from bell mouth in the collecting tank upto the rising main laid by the department as per plan shown from the foundation wall of the pump chamber for all the raw water and clear water pumping sets at water works as per specification given in schedule No.II Details of pipe and specials. CI D/F bends, reducers, tees etc (Old Water Works & 2nd Water Works & 2 No. B/STN)
CI D/F pipes 100mm i/d
Panel Board for Motors Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- For Old WW set 500 LPM x 12 M. Head = 1 Nos. A Main switch 100 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 1 Nos. for 500 LPM x 12 Head motor (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 100 Amp. = 1 No.
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- For Clear water pump set 800 LPM x 40 M. Head = 1 Nos. A Main switch 32 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 1 Nos. for 800 LPM x 40 Head motor (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 200 Amp. = 1 No. (One for Each pump set) at Old & 2nd WW Nehla
Supply, erection, testing and commissioning of wall mounted electrical LT panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200x900mm and 400mm deep having following item:- For Clear water pump set 400 LPM x 30 M. Head = 1 Nos. (One for Each pump set) at 2nd Water Works Nehla A Main switch 32 Amp 1 No. (L&T siemens, ABB). B Volt meter 100x100mm range 0 to 500 volt= 1 No. (AE/KAPPA/L&T) C Amp. Meter 100x100mm range 0 to 100 volt= 2 No. (AE/KAPPA/L&T) D CT 100/3 No. (AE/KAPPA/L&T) E VSS & ASS 1 No. each No. of approved make F SSP 4 No. of approved make/ minilac G Motor starter star delta 1 Nos. for 400 LPM x 30 Head motor (L&T, Siemens, ABB) H Capacitor KVAR as per site requirement I Indicating Lamp One Set J Change over Switch 63 Amp. = 1 No. (4 No. at Both WW and 5 No.B/Stations)
Diesel Generating Set Designing, Supply & erection of DG set of required capacity given below with acoustic of suitable rating with change over switch, fenced enclosure with platform for DG sets complete as per DNIT. The rating should be at 1500 RPM (a) Diesel Engine b) Alternator c) Bettery 24 V The rating should be at 1500 RPM (d) Base Plate (e) 1x120 sq mm 3.0 core XLPE Aluminum = 20 m A.M.F. PANEL (a) Motorised change over switch 250 Amp 4 P with fuse base and HRC links 250 Amp. (b) Under voltage/ over voltage relay - 2 No. 415 VAC (c) Engine Start relay 24 VDC 1 No. (d) Electronic Timber 24 VDC 1 No. (e) Electronic Timber 24 VDC 2 No. (f) Auxiliary relay 220 VAC - 2 No. (g) Auxiliary relay 220 VAC - 3 No. (h) Metering set 415 VAC - 1 set (Amp. Meter, Volt Meter, ASS, VSS, Phase Indicaters, Control fuse, frequency meter, CT'S) (i) Metering set 24 V DC (Amp. Meter, Volt Meter) (j) Over Load protection for DC - 1 No. (k) Battery Charger 24 V DC (Blueron make) (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch (On/Off) (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature. (p) Indicating lump for low lubricating oil pressure high collant tempurature, set running, load on, DC control on. Note: Control Panel shall have the provision to provide auto manual failure panel (AMFP). a) Old Water Works 100 KVA
b) 2nd Water Works 100 KVA
Transformer Design, Supply & erection of transformer of standard make Required KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T, metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer from metering to transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per DNIT ( Make Kirlosker, Crompton & GEC ) Required at following sites as per respective capacity a) Old Water Works 70 KVA
b) 2nd Water Works 70 KVA
Supply, erection, testing of reputed make LED light 100 watts with fitting and accessories in all respect (Bajaj/ Philips, Crompton)
Supply and fixing of D.I.Specials (KISWOK & Misal DMJ ) bends , reducers , Tee etc. including cost of Jointing materials, laying, jointing, in position as per specification
Providing & fixing of D.I. Air Valve “IVC” Brand soft seated as confirming to I.S.I. complete in all respect. (Pump House D.I.Rising main and Old & 2nd Water Works 80mm
Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete with suitable G.I sheet Ducting in meter room and pump Chamber and energy for the sites. (Pump House D.I.Rising main and Old & 2nd Water Works and 5 No. B/STN)
Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect. (Pump House D.I.Rising main Old & 2nd Water Works and 5 No. B/STN)
Supply erection, testing of light fitting including wire in the pump chamber with material upto 10 points including switch, button, plug, PVC conduict pipe & copper wire etc. as per approved specifications. (Pump House D.I.Rising main and Old & 2nd Water Works and 5 No. B/STN)
Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification. (Pump House D.I.Rising main and Old & 2nd Water Works and 5 No. B/STN)
S&S Tank (a) Providing & fixing suitable floating arme 300 mm size along with swivel bend as per required specifications approved by Engineer-in-Charge 1 No. Old & 1 No. 2nd WW/ Nehla
Providing and fixing of PVC water Bar (fixo- stop) with ribs & central bulbs of size given below confirmed to IS-12200 of 1987 (fixo-stop) along with the bitumen board including cost of bitumen filler complete i) 250 mm wide x 8 to 11 mm thickness. (5 No. Clear Water Tank) WW and B/Stations
Supply erection, and commissioning electric operated dewatering pump of 3 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete.
Supplying and fixing of Gantry with chain pulley block of 2 tones capacity with traveling trolley of appropriate lifting capacity for handling of pumping sets capable of moving along the girders to be provided in the pump house complete in all respects as per details in DNIT.
Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect. Old & 2nd WW & 5 No. B/STN
Operation & Maintenance of water Works(disinfection material Supplied by the PHED) as per Scheduie-IV for a period of 5 years (60 Month) after three month of trial run (Will be charged to the A/Mtc. Estimate) Operation and maintenance during the defect liability period (Operation only) (New Structures, Both WW & B/STN)
Ist year Operation and maintenance during the defect liability period (New Structures, Both WW & B/STN)
2nd year Operation and maintenance (New Structures, Both WW & B/STN)
3rd year Operation and maintenance (New Structures, Both WW & B/STN)
4th year Operation and maintenance (New Structures, Both WW & B/STN)
Bidder Name
Amount
Umesh Kumar Contractor
RAM CHANDER JAIN CONTRACTOR
Umesh Kumar Contractor
RAM CHANDER JAIN CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .