| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹14.0 L+₹3.7 L (36.4%)Rejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹14.8 L+₹4.5 L (43.7%)Rejected-Finance | L3 | Rejected-Finance Other Than L1 |
Tender Value
₹19.9 L
EMD Value
₹40,000
Closing Date
13 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR/REPLACEMENT WORK OF EXTERNAL ELECTRIC SUPPLY AND ALLIED SERVICES AT BASE CAMP AND PARTAPUR UNDER GE PARTAPUR
2023_MES_586053_1
138WE/L-10/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Partapur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Partapur
₹40,000
Yes
8 May 2023
16 Mar 2023
20 Apr 2023
16 Mar 2023
13 Apr 2023
30 Mar 2023
Amount
Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 10 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmm, complete all as specified and as directed by Engr-in-Charge.
Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 185 sqmm, complete all as specified and as directed by Engr-in-Charge.
M&L for line separators of LT OH lines with nut, bolts & washers straight type fixed at a point as directed and suitable for 4 wire complete all as specified and as directed by Engr-in-Charge.
M&L for Painting steel and iron surfaces, old/new surfaces of steel tublar poles/steel tublar swaged poles of any description, length n. exc 9 mtr above ground level incl angle iron/clamps bracket etc with one coat of silver aluminium paint two coat of synthetic enamel paint upto 1.5 mtr above coping in 30 cm wide strips in alternate black and Yellow colour, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles, complete all as specified and as directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron earth strip of size 32 x 6 mm thick by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected, complete all as specified and as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil, complete all as specified and as directed by Engineer-in-Charge.
Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, complete all as specified and as directed by Engineer-in-Charge.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
M&L sand cushioning for under ground cable 8 cm before laying the cable and 15 cm after laying and streching the cable, complete all as specified and directed by Engineer-in-Charge. Note:- Punned thickness only to be measured for payment as per SSR.
M&L Un-reinforced precast factory made concreate cable covers, class LV type-I, with flat size 250x150x40 mm, complete all as specified and directed by Engineer-in-Charge.
Supply and laying/fixing, GI pipe medium grade 40 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection, complete all as specified and as directed by Engr-in-Charge.
Supply and laying/fixing, GI pipe medium grade 50 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection, complete all as specified and as directed by Engr-in-Charge.
Supply and laying/fixing, GI pipe medium grade 80 mm bore (dia)including all type fittings fixed on walls/to poles with clamps /laid in trenches as cable protection, complete all as specified and as directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 63 Amps with breaking capacity 16 KA, adjustable type complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 100 Amps with breaking capacity 16 KA, adjustable type, complete all as specified and as directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 125 Amps with breaking capacity 16 KA, adjustable type, complete all as specified and as directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 36 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 250 Amps with breaking capacity 36 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 36 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 160 Amps with breaking capacity 25 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
S&F MCCB 4 Pole, 415 V, 400 Amps with breaking capacity 50 KA, adjustable type, complete all as specified and directed by Engr-in-Charge.
Supply,laying ,testing cable or unarmoured electric cable (service wire) in replacement of size 10 sqmm 2 core complete all as specified and directed.
Material and Labour for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in foundation, filling or mass concrete as in foundation stays etc, complete all as specified and as directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps, complete all as specified and as directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 160 Amps, complete all as specified and as directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps, complete all as specified and as directed by Engr-in-Charge.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing LT cable route direction metal sign board, yellow color circular plate with written indication and fixing arrangement on earth, complete all as specified and as directed by Engr-in-Charge.
RND ENGINEERS & CONTRACTORS
darshan kumar gandhi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .