Loading…
Loading…
Tender Value
₹2.7 L
EMD Value
₹5,370
Closing Date
27 Aug 2026, 2:00 pm3d left
The AE, Uluberia ESD, PWDte
PWD Campus, Gangarampur, Uluberia, Howrah, WB, Pin-711316
Replacement of old window AC and allied El works at Establishment cum Account Section of MSVP at Sarat Chandra Chattopadhyay Govt. Medical College and Hospital, Uluberia, Howrah. (Electrical Work), Project ID- HF262751712S000
2026_WBPWD_5018355_1
WBPWD/AE/UESD/eNIT-04 of 2026-2027
Open Tender
ELECTRICAL WORKS ORG
Percentage
Sarat Chandra Chattopadhyay Govt. MCH, Uluberia
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,370
11 Aug 2026
11 Aug 2026
31 Aug 2026
12 Aug 2026
27 Aug 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SUB-HEAD 1 - SITC OF AC MACHINE | |||||
| 2 | Supply of 2.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1Nos.Rotary compressor, 1nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-230V-1ph-50Hz, R-32/R410A Refigerant. Air-flow/per IDU:- 600CFM. The indoor unit should be compatible with Wired LCD remote controller with alphabetic error display like HP, LP, SPPR. ( Make: Hitachi/Carier/Voltas or equivalent make/model as approved by E.I.C) | 3 | Nos | 55,376 | ₹1,66,128 |
| 3 | Erection, testing & commissioning of above-said split type concealed air conditioner of 2.0/1.5 TR capacity. The indoor unit must be supported by structure made of 25X25X5 mm angle and tie rod, fastnut etc. incl. necy. mending works as per direction of E.I.C. | 3 | Nos | 1,885 | ₹5,655 |
| 4 | Supply & Delivery of R-32/R-410A refrigerant gas. | 2 | Kg | 550 | ₹1,100 |
| 5 | Supply Installation and Commissioning of 5/8" hard/soft copper refrigerant piping, complete with fitting, elbows, bends, supporting arrangement on walls. | 30 | RM | 278 | ₹8,340 |
| 6 | Supply Installation and Commissioning of 1/4" hard/soft copper refrigerant piping, complete with fitting, elbows, bends, supporting arrangement on walls. | 30 | RM | 151 | ₹4,530 |
| 7 | Supply & Fixing Pipe Insulation in suction line 5/8" with 19mm 'O' class nitrile rubber tube(Make:Accoroflex/Suprime) | 30 | RM | 38 | ₹1,140 |
| 8 | Supply & Fixing Pipe Insulation in liquid line 1/4"with 19mm 'O' class nitrile rubber tube Suction Line (Make:Accoroflex/Suprime) | 30 | RM | 19 | ₹570 |
| 9 | Providing and laying electrical cabling 3/4 Core 2.5sq. mm. Communication Cable (Make:Finolex/KEI/Polycab) | 45 | RM | 132 | ₹5,940 |
| 10 | Supplying fabrication & fixing of outside Iron structure by grouting 2 nos M.S Angle on wall suitable size for installation of outdoor unit of AC incl drilling 2 nos holes in each Angle and horizontal at suitabie size in each stand. Each stand will be properly fixing by supporting and fabricated Angle of suitabie size and flush nut on peripheral wall as per machine configuration & load with adequate service acces as per direction of EIC and by grouting suitabie size of M.S U channel for making base frame incl. drilling of holes in each channel, cutting holes into the wall & grouting the same with cemant concrete(1:1.5:3). | 120 | Kg | 80 | ₹9,600 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.51 MB
2911.pdf
Tender Documents • 1.86 MB
BOQ_5089322.xls
BOQ • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].