Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.9 L+₹2.5 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹32.8 L+₹8.4 L (34.2%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹34.8 L+₹10.4 L (42.4%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹34.8 L+₹10.4 L (42.7%)Rejected-Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
29 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SRINAGAR
GE (AF) SRINAGAR
Provn of mechanical chimneys at cook houses of snco mess and no. 1 2 airmen mess along with accessories fittings of gas pipe from exterior to cook house and cages for gas cylinder and improvement to cook house of offr mess at AF Stn Srinagar.
2023_MES_626068_1
GE (AF)/SGR-56/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
SRINAGAR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹87,300
Yes
2 Jan 2024
1 Nov 2023
1 Dec 2023
1 Nov 2023
29 Nov 2023
15 Nov 2023
Amount
Schedule 'A' Part-I (Building Works)
Taking down chowkats or frames with shutters (without taking of shutters from the frame) n.exc 1.5 Sqm each, complete all as specified and directed.
Taking down chowkats or frames with shutters (w/o taking of shutters from the frame) exc 1.5 but n exc n.exc 4 Sqm each, complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. complete including removal of debris to a distance exc 1.5 Km but n exc 2 Km, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (But not backing), removing and rubbish of the premisses, complete including removal of debris to a distance exc 1.5 Km but n exc 2 Km, complete all as specified and directed.
Demolition of stone/boulders or brick masonary built in cment mortor including all quoins, arches, pillars, etc but excluding ashlar facings, dresses stone work and precast concrete articles etc, complete all as specified and directed.
Dismantling of stone slabs and tiles of any description or thickness, laid bedded and pointed in any mortar in floors, aprons etc, including removal of debris to a distance exc 1.5 Km but n exc. 2 Km, complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description in Any position complete including removal of debris to a distance exc 1.5 Km but n exc 2 Km, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), including removal of debris to a distance exc 1.5 Km but n exc. 2 Km, complete all as specified and directed.
Dismantling of boarding, any description, fixed in any position with nails, complete all as specified and directed.
M&L for 2nd class softwood clean sawn boards or planks 20 mm thick width n exc 25 cm fixed to wall, complete all as specified and directed.
Dismantling unframed work timber scantlings 40 sqcm and over in section, in any position, complete all as specified and directed.
M&L for 2nd class soft wood ( Kail ) clean sawn as in post and scantling for ceiling or roof members, complete all as specified and directed.
M&L for PCC 1:2:4, type B-2(using 40 mm graqded crushed stone aggregate) as in drain and channels, complete all as specified and directed.
Extra for forming fair finished drain or channel 55 cm inner girth in cement concrete using extra cement including forms, moulds, mi-tred/ stopped ends etc., complete all as specified and directed.
M&L for Brickwork with sub-class 'B' bricks, straight or curved on plan exc 6 m mean radius with old size bricks, built in CM: 1:6, complete all as specified and directed.
All as per Ser item No 1.16 here-in-before but except bricks.
M&L for Brickwork with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in CM: 1:6, complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20 mm graqded crushed stone aggregate) as in copings including weathering slightly or chamfered angles etc.,complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 (nominal mix), type B0 (using 12.5 mm graqded crushed stone aggregate) as slabs supported on walls, beams and columns in floors, roofs, landings, balconies, manhol cover slabs and in shelves etc, complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc, also splays between floors and beam, etc, to rough finished surface of concrete, complete all as specified and directed.
M&L for 20-25mm thick Machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including and over 20 mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L for 20 mm thick granite (of any type) tiles, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete and including and over 15 mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6, type C-2 (using 40mm graqded crushed stone aggregate) as in pavement finished even and rough, complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar 1:6, for laying floor finish, complete all as specified and directed.
M&L for colour chequered cement concrete tiles size 25cm X 25cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with white cement and pigments, complete all as specified and directed.
M&L for vitrified tiles 10 mm thick, light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including and over 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
M&L for vitrified tiles 10 mm thick, light shade (square/rectangular) polished on vertical surfaces such as skirtings, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including and over 10 mm thick rendering in cement mortar 1:3, complete all as specified and directed.
M&L for Glazed ceramic coloured tiles 450 x 350 x 7 mm thick as in vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match over and includind 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed.
S&F Sinks made of stainless steel, 1mm thick without drainage board with plugs, washers and wastes; including bedding in cement mortar on RCC Shelve, connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F in repair 15 mm bore CP Mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed.
S&F in repair 15mm bore bib cock CP, fancy type, cast copper alloy, screwed down, screwed for iron pipe or brass ferrule, complete all as specified and directed.
S&F in repair 15mm bore Angle cock , CP, cast copper alloy screwed down high pressure, screwed both ends for iron pipes or for unions, complete all as specified and directed.
S&F in repair PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
S&F in repair waste coupling 32mm or 40mm CP for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed.
S&F in repair polyethylene and unplasticised PVC pipe 32 mm bore low density polyethylene (LPDE) pipes of pressure rating 6 kgf/sq. cm, complete all as specified and directed.
S&F in repair 100 mm outlet cast iron floor trap with CP gratting including jointing to waste pipe fixed in cement concrete type B1(1:2:4), complete all as specified and directed.
Taking up or down old 15 mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing, removal to store, complete all as specified and directed.
Taking up or down old 20mm bore steel tubing fixed to wall and ceiling or laid in floor,with all fittings and fixtures and short lengths including cleaning for refixing or removal to store, complete all as specified and directed.
S&F for steel tubes, 15 mm bore, galvanised, " medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
All as per Ser item No.1.41 here in above but except GI tubing.
S&F for steel tubes, 20 mm bore, galvanised, " medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
All as per Ser item No.1.43 here in above but except GI tubing.
S&F for Rotational moulded polythelene water storage tanks 1000 ltrs capacity, (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part- I including dismantling of old water storage tank, complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed stone ware, AC PVC or reinforced concrete) set in cement mortar for 150mm dia pipes, complete all as specified and directed.
S&F for PVC (SWR) 110mm bore of pipe single socketed in any length with rubber ring joints, laid in trenches or in floors etc, complete all as specified and directed.
M&L for plain cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested in plain cement concrete M-7.5 (Nominal mix) type D-2 (using 40mm graded crushed stone aggregates) for 100mm bore pipe, complete all as specified and directed.
M&L for Cement concrete 1:4:8, type D-2 (Using 40 mm graded crushed stone aggregate) in foundation, filling and mass concrete, complete all as specified and directed.
S&F for pressed steel frames size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F for 35 mm thick 2nd class hardwood factory made plain framed panelled shutters (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F for 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, guaze, etc.(without sash bars), edges of framing plain chamfered or rounded fitted with cut and metered beads for securing glass etc . sizes of members of shutters as specified in SSR-I , section-8, clause-8.24(a); supplied and fitted to chowkats, complete all as specified.
S&F for Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with finned tacks of galvanised wire staple fixed with stainless steel wire staples, complete all as specified and directed.
S&F for 100mm size butt hinges medium weught , cold rolled MS and fixed, complete all as specified and directed.
S&F for 150mm size aluminium anodised, barrel tower bolts, of extruded section and fixed, complete all as specified and directed.
S&F for 150mm size Handles extruded aluminium alloy handles,fabricated type anodised, complete all as specified and directed.
S&F for 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
S&F for Mild steel 300mm, ordinary rat tail rod patttern springs including roller and roller plate complete all as specified, complete all as specified and directed.
S&F for 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door/windows stops and the like, including all necessary' labours; articles n exc 200 cucm each including butt hinges, size 50 mm, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:6 finished the surface even and smooth (without using extra cement on internal wall surface, complete all as specified and directed.
M&L for 15mm thick rendering on fair faces to brick work or stone masonry surface in CM 1:4 finished the surface even and smooth (without using extra cement on external wall surface, complete all as specified.
Preparation of new plastered wall surface and applying two coats oil bound distemper on, complete all as specified and directed.
Preparation of wall surface and finishing walls with Acrylic Smooth exterior paint with spurge roller of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed.
Preparation of old plasteres/unplastered ceiling surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white washing, complete all as specified and directed.
Preparation of old plasteres/unplastered wall surface including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of distemper oil emulsion with spurge roller, complete all as specified and directed.
Preparetion of new steel surfaces and applying two coats of synthetic enamel paint, complete all as specified.
Preparation of old painted wooden surfaces of any description not otherwise described over 10 cms width or girth including preparation of surface and applying one coat of synthetic enamel paint, complete all as specified.
Preparation of new or previously untreated wood and wood wood based surfaces of any description, over 10 cm in width or girth and finishing and applying two coats of synthetic enamel paint over pink primer, complete all as specified.
Schedule 'A' Part-II (Electrical Works)
Supply, installation, Testing and commisioning of commercial mechanical chimney consisting of Baffle Hood with filter (SS 302) of size 85x48 inches with suitable size SS grills including suitable size SS duct, for exhaust purpose the length of chimney should be minimum 30 ft approx and thickness of stainless steel sheet shound not be less than 0.5 mm including industrial exhaust fan 900 mm sweep 3-phase, 415 Volts complete fitted 02 Nos on both side in SS baffle hood, complete all as specified and directed.
Taking down carefully Exhaust fan 450/600 mm sweep, or overhauling including dismantling of blades frame and opening and examining motor cleaning of dust/dirt of fan cleaning and greasing of ball bearing and bushes with fresh oil and best quality of grease respectively and reassembling of complete fan after re-fixing parts, complete all as specified and as directed.
Fixing only exhaust fan and connecting up including provision of cable 3 core flexible from ceiling rose or connector to fan, complete all as specified and as directed.
S&F in replacement including jointing and testing, LT cable 1100 volts grade of cross sectional area 50 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables, complete all as specified and as directed. (Note : MS clamps with nuts, bolts washer etc shall be measured and paid separately under relevant items)
S&F in replacement including jointing and testing, LT cable 1100 volts grade of cross sectional area 16 Sqmm 4.0 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables, complete all as specified and as directed. (Note : MS clamps with nuts, bolts washer etc shall be measured and paid separately under relevant items)
M&L for 50mm dia steel water tubing, light grade, galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified and directed.
S&F in repair for submain wiring with three run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 6.0 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, complete all as specified and directed. Note:- (i) 3 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purpose.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth and getting out for laying of underground cable etc in any type of soil, complete all as specified and directed. (Qty clubbed For B&R Work- 13.00 Cum & EM work- 75.60 cum)
Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25 cm thick in any type of soil, complete all as specified and directed. (Qty clubbed For B&R Work- 8.00 Cum & EM work- 50.84 cum)
Removing of excavated soil to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and directed. (Qty clubbed For B&R Work- 5.00 Cum & EM work- 24.76 cum)
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks, complete all as specified and directed.
M&L for dry & clean sand cushioning in trenches spreading and consolidation 8 cm thick before laying the cable and 15 cm of sand after laying the cable and punned the same up 18 cm, complete all as specified and directed. Note:- Only punned thickness shall be measured and paid.
S&F in repair epoxy powder coated or polystrene insulated material sheet metal enclosure factory made (double door) 8 way SPN suitable for MCB DB's 240 Volts with 200 Amps rated busbar, neutral & earthing link bar, flush/surface mounting, complete all as specified and directed.
S&F TPN/Isolator of cap 40 Amp, complete all as specified and directed by Engr-in Charge
S&F in replacement of Feeder pillar board kiosk type, LT (415 Volts, 50 Hz, 3 Phase, 4 wire supply) floor mounted, factory assembled, outdoor type weather and vermin proof (Protection class IP-54) made out and 3.15mm thick MS sheet CRCA sheet aluminium bus bar of 200 Amps capacity with hinged opening, rubber lining , locking arrangement, minimum 3 outgoings, including 100 Amp MCCB 4 pole-01 No as incomer and 63 Amp MCCB 4 pole-01 No as outgoing complete, painted externally and internally with two coats of synthetic enemel gray paint first quality ovar a coat of red oxide primer, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electode 600 mm x 600 mm x 6.00 mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised iron strip 25x 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion complete all as specified and directed. Note: (i) The unit rate includes GI pipe up to 7.5m for protection of earth lead. For any additional length the same shall be adjusted through deviation order. (ii) The unit rate includes main earthing lead/strip from earth electrode to test point up to 7.5 meter (iii) In case measured value of earth resistance is recorded more than 1.0 ohms then the earthing shall be re done by the contractor without any extra cost to the department.
Deduction to be made from BOQ for Schedule 'A' Part-II (Credit Schedule from dismentling/taking down items) worth Rs 39,015.00 during AOC. Note :- Tenderers shall not quote for this Schedule.
M/S A.R.TANTARY
M/S GHULAM HASSAN AND SONS
Kesar Impex
M/S MIR AND CO
M/S Thakur & Sons
M/S BASHIR AND SONS
M/S Abdul Ahad Rather
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .