Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹94.4 LAccepted-AOC | 1 | Accepted-AOC being lowest bidder | |
| 2 | 2₹1.1 Cr+₹8.8 L (9.04%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | 2 | Rejected-Finance other than lowest | |
| 3 | 3₹1.1 Cr+₹14.5 L (14.9%)Rejected-Finance | 3 | Rejected-Finance other than lowest | |
| 4 | 4₹1.3 Cr+₹29.1 L (29.9%)Rejected-Finance DH 101 DEEN DAYAL NAGAR MAHARAJPUR GWALIOR 474020 MP | GWALIOR | MADHYA PRADESH | 474020 | 4 | Rejected-Finance other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Firm banned as per WLR of CECC QE Jun 2024 on Srl No 216 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
6 Nov 2024, 6:00 pmClosed
CWE AF Gwalior
HQ CWE AF Gwalior 474020
SPECIAL REPAIR/ REPLACEMENT OF SLD FENCING, ADDN/ ALTN TO ANNEXE OF P3 HANGAR AND PROVN OF BIRD PROOFING NET IN CERTAIN SQNS AT AF STN GWALIOR
2024_MES_678592_1
86000/E8
Open Tender
Civil Works
Item Rate
270 days
AF Stn Gwalior
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (AF) (Tech Area) Gwalior
₹2.0 L
Yes
20 Dec 2024
8 Oct 2024
11 Nov 2024
8 Oct 2024
6 Nov 2024
23 Oct 2024
Amount
Demolition of brickwork or stone masonry of any description and in any position built in cement mortar including all quoins, arches pillar etc etc, but excluding ashlar facings, dressed stonework and precast concrete articles including disposal of rubbish complete all as specified and directed.
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in foundation, filling fencing post and mass concrete, including necessary formwork complete all as specified and directed.
M&L for brickwork with old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius in half brick thick wall built in CM (1:4) complete all as specified and directed.
M&L brick work with old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) complete all as specified and directed.
M&L for 15mm thick rendering on fair face of brick walls in CM (1:4), surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material to a distance n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed.
Dismantling of posts, struts (wood, steel or RCC) any section including taking out embedded portion in concrete or brick masonry of any position place incl swan neck fencing and making good disturbed portion removing excavated debris up to a distance n.exc 50m complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description at any place not otherwise provided for complete all as specified and directed.
M&L for mild steel fencing post including cutting and welding tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets for securing wire mesh etc including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 and all as specified and directed.
Fixing only of 4mm dia chain link fencing, of mesh (50mmx50mm) size, of any type to angle iron/MS fencing post with MS Flat Iron, and fencing shall be strengthened by fixing MS flat/round bars horizontally complete all as specified and directed. Note: (i) S&F of FI, Angle, round bar & bolts shall be measured and paid separately. (ii) Supply only of chain link fencing shall be measured and paid separately.
Supply only 4mm dia galvanised steel chain link fencing of mesh size 50mmx50mm with both ends of the fabric without knocking and twisting any size complete all as specified and directed.
M&L for 12mm round bar for securing chain link fencing, cutting, welded to each other complete all as specified and directed by Engr-in-Charge.
S&F of mild steel screw bolts (machine made) 16 to 20mm dia of neck and length of bolt exc 5cm but n.exc 10cm, with hexagonal or square heads at one end and screwed ends fixed with two washers and one nuts complete all as specified and directed.
S&F in repairs galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and including galvanised MS wire, staples or steel pin etc complete all as specified and directed. Note: - Each line of wire to be measured.
M&L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surfaces n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, and getting out, and removing excavated material to a distance n exc 50m and complete all as specified and directed.
Taking down existing concertina coil of any description, any size kept aside safely and refixing the same in its position carefully after repairing work of connecting chain link fencing/Security wall fencing all as specified and directed.
M&L for Cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and directed.
M&L for Hand packing of broken bricks (any thickness) at back of walls over arches etc. and raising (or lowering) to the required level and all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking, and bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars over 5mm dia and up to and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required including cranking, hooking ends etc, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on brick masonry surfaces to finish even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surface of wall of any description and applying two coats of oil bound distemper over and including one coat of primer and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (Using 12.5mm graded stone aggregate) as in sub base floor to receive floor tiles complete all as specified and directed.
M&L for screed bed 15mm thick in CM 1:6 for laying floor finishes and all as specified and directed.
M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per item no. 32.00 here-in-before but in skirting and all as specified and directed.
M&L for rendering 10mm thick in CM 1:4 on brick masonry or concrete surfaces to finish even and rough to receive wall tiles complete all as specified and directed.
M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed.
M&L for Seamless calcium silicate ceiling made out of 1800 x 1200 mm size and thick 8mm board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self-drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately) complete all as specified and directed.
S&F Gl frame work for seamless ceiling of grid comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with 3mm dia GI cleat and steel expansion fasteners with and including ceiling section (exc 1.2m length) of 0.55 mm thickness having knurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 450 mm centre to centre.
S&F Joist, channel, angle, or tee sections of Fe-290 Gde E -165, fixed independently, without connecting plates, etc complete all as specified and directed.
S&F for MS Plates (plain or chequered channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment and complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n exc 4 sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sqm each complete all as specified and directed.
S&F UPVC sound proof door frame with shutter and DGU (double glazed unit) (5T+12+5T) toughened glass (one glass transparent and one glass tinted) with cylinder of one side key, one side thumb turns and locking system including necessary builders hardware etc, junction of wall and frame sealed with sealant complete all as specified and as directed by Engr-in-Charge.
S&F UPVC luxury casement sound proof side Hung/ Tilt &Turn type windows and frame with DGU (double glazed unit) (5T+12+5T) toughened glass (one glass transparent and one glass tinted) with cylinder of one side key, one side thumb turns and locking system including necessary builders hardware etc, junction of wall and frame sealed with sealant complete all as specified and as directed by Engr-in-Charge.
S&F UPVC luxury casement sound proof fixed type windows and frame with DGU (double glazed unit) (5T+12+5T) toughened glass (one glass transparent and one glass tinted) with cylinder of one side key, one side thumb turns and locking system including necessary builders hardware etc, junction of wall and frame sealed with sealant complete all as specified and as directed by Engr-in-Charge.
S&F bird proofing net for hangar/shed/shelter etc up to 15m height complete as per manufacturer's instructions: (a) Type of bird proofing net : Polyolefin all weather proof co-primer (b) Method of knotting : Machine knotting using CNC machine with DSLS technology for anti-slip knotting (c) Heat Setting : Steam set for greater dimensional stability and knot firmness (d) Diameter of the twine : 1mm dia wire with square mesh size 25mmx25mm (+/- 2mm) (e) TBS (twine breaking strength) : 16kgf min (f) MBS (Mesh breaking strength) : 12kgf min (g) KBS (Knott breaking strength) : 22kgf min Note : All necessary items i.e clip, nuts, washers and other accessories required for proper fixing as per manufacturer's instructions shall deemed to be included in the quoted rate.
Dismantling expanded metal, any thickness or mesh (weight exc 4kg/sqm), fixed with steel or wood fillets, if any at height up to 15 m and all as specified and directed.
Dismantling of nylon bird proofing net of any size as directed at height up to 15m and all as specified and directed.
S&F Fe 410-W (Gde- E- 250) quality-A Joist, channel, angle, flat iron or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) including all necessary drilling, bolting, riveting or welding complete all as specified and directed.
Dismantling of LT Panel, distribution boxes and GPU Supply point of any Size from its existing position, platform and reshifting to new location in same bldg with making arrangement of PCC Platform of suitable size and including painting of LT Panel after removal of outer surface complete with one coat of Red Oxides Primer and two coats of synthetic enamel paint complete all as specified and directed by Engr-in-Charge. Note : Cost of PCC platform is deemed to be included in the quoted rate.
M&L for point wiring with stranded copper conductor 1.5. Sqmm 1100 Volts grade FRLS PVC insulated and unsheathed including ISI marked PVC casing capping of required sizes including all accessories, copper conductor cable 1.5 Sqmm insulated and unsheathed PVC cables as earth wire, modular terminal boxes closed recessed type PVC modular board all as required as specified and directed for the following :- (a) One light/ Fan point controlled by one way switch.
(b) One 5 Amps switch socket combination on independent board.
(c) One 5 Amps socket on same board with other switches.
All as per item No 50.00 here in before but 2.5 Sqmm stranded copper conductor and independent board for 15 Amps switch/ socket point complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Modular switch 1way 6A, 1 module single pole 230 V complete all as specified and as directed.
S&F in repairs Modular type switch socket outlet 3 pin 6 Amps flush type 230 Volts multipurpose, complete all as specified and as directed.
All as per item no. 53.00 here-in-before but 6 Amps and 16 Amps multipurpose (3 Pin 16 Amps and one pin 6 Amps controlled by one switch) complete all as specified and as directed by Engineer-in-Charge.
M&L in replacement for sub-main wiring of using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm FRLS of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit along-with one run of PVC (Green colour) insulated , unsheathed, stranded copper conductor of size 2.5 Sqmm as earth continuity conductor complete all as specified and directed. Note:- Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M&L for sub main wiring in replacement of using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm, FRLS of voltage rating upto and including 1100 Volts drawn in concealed PVC conduit along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed. Note:-Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
Supply, fixing, connecting & testing of sheet metal enclosures double door (IP-42 Protection), triple pole and neutral, 12 way DBs Vertical type for using MCBs/ MCB isolators with and including aluminium bus bars suitable for 200 Amps rating complete all as specified and directed.
All as per item no. 57.00 here-in-before but distribution board single pole and neutral, 12 way complete all as specified and directed.
All as per item no. 57.00 here-in-before but distribution board single pole and neutral, 8 way complete all as specified and as directed.
S&F MCCB, 3 pole, 100 Amps current rating and ultimate breaking capacity Icu = 36 kA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed.
All as per item no. 60.00 here-in-before but MCCB, 3 pole, 63 Amps current rating and ultimate breaking capacity Icu = 16 kA complete all as specified and directed.
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB DP, 63 Amps (`C’ series) having current rating 10 KA, 240V 'C' curve miniature circuit breaker complete all as specified and directed.
All as per item no. 62.00 here-in-before but MCB DP, 40 Amps (`C’ series) having current rating 10 KA, 240V 'C' curve miniature circuit breaker complete all as specified and directed.
Supply and fix MCB (SP) Single pole, 6 to 32 Amps Amps, 230 volt (`C’ series) having current rating 10 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed by Engineer-in-Charge.
Supplying, fixing & testing decorative surface mounting 36 watt LED full output luminaries which provides soft light glare free symmetrical illumination suitable for Armstrong/Grid ceiling, white powder coated sheet steel housing with paralite P5 square parabolic louver block in metallic perforated frame for low glare, aluminium reflector and accessories, connecting the same to electric source with and including copper conductor 23/0.0076 flexible twisted twin core cable, including all accessories and fixing arrangements for fixing the light fitting to false ceiling complete all as specified and directed.
S&F ceiling rose surface bakelite ISI marked, 2 to 3 terminal all as specified and directed.
Supply and fix in replacement of triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split units indoor/outdoor complete with cordless remote-control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3-star rating and EER 3.2 of capacity 2 TR complete all as specified and directed by Engineer-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air-cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.00 KVA complete all as specified and directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. 5-star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs fan regulator Electronic Step type (min 5 steps) 2module, 100W ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted fan 450 mm sweep having oscillating motion and speed control facility complete with accessories 230 V, single pole and connecting up including provision of cable from ceiling rose or connector to fan complete including cutting out holes in existing cement concrete/ brick walls built in cement mortar and removing unserviceable/ loose and supplying, fixing & grouting new purpose made arrangements all as directed including making good the disturbed surfaces to match with the existing surface & finishes complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.50 mtr and below normal ground level connected to galvanised earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electric plate No-5 connected to earthing test point all as specified or indicated including testing on complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and laying PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 70 Sqmm in cable duct/ trench complete all as specified and directed by Engineer-in-Charge.
Supply and laying PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 50 Sqmm in cable duct/trench complete all as specified and directed by Engineer-in-Charge.
Supply and laying PVC insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 35 Sqmm in cable duct/trench complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 70 Sqmm, Indoor/ Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 50 Sqmm, Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 35 Sqmm, Indoor/Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair of MCCB, 4 pole, 160 Amps current rating and ultimate breaking capacity Icu = 36 KA with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed. Make: Havells/ABB/Legrand/C&S
All as per item no. 81.00 here-in-before but MCCB, 3 pole, 125 Amps current rating and ultimate breaking capacity Icu = 16 KA complete all as specified and as directed by Engineer-in-Charge.
RAVINDRA SALES (BID ID -3159372)
M/s Kohli Builders (BID ID -3158599)
M/s Bijender Singh (BID ID -3152966)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .