Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAdmitted-Finance R C PANDIT LANE NAMOPARA PURULIA | PURULIA | PURULIA | WEST BENGAL | 723101 | L1 | Admitted-Finance | |
| 2 | L2₹1.4 L+₹1,186.44 (0.87%)Admitted-Finance 266 1 S B GORAI ROAD BESIDE VIDYASAGAR MAIDAN ASANSOL 713301 | ASANSOL | BURDWAN | WEST BENGAL | 713301 | L2 | Admitted-Finance | |
| 3 | L3₹1.4 L+₹3,117.15 (2.29%)Admitted-Finance KALYANESWARI PASCHIM BARDHAMAN WEST BENGAL | KALYANESWARI | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premnath Mitra L1 | SUNRISE ENGINEERING CORPORATION L3 | M/S. SWAPAN BANERJEE L2 |
|---|---|---|---|---|---|---|
| 1.00Valve replacement portion:- | ||||||
| 1.01 | 200 mm dia, P.N.-1.6 cast iron double flanged Rising Spindle Sluice Valve generally confirming to IS:14846 having body door /dome/Bonnet and cover of cast Iron Gr FG 260, outside screen rising Spindle of IS 6603 Gr-12 cr-13, spindle nut & seat rings are Gunmetal as per 1S:318 LTB 2. Flanges flat faced and drilled to IS:1538 Part IV & VI, Valves are suitable for maximum working pressure of 16 kg/sqcm (seat test) and body tested to 24 kg/sqcm. All the valves should be tested by closed end method only.(Make:-IVI/Jupiter/Other approved make)(Delivery side of Pump No-03) | 1 | No | 35,245 ₹35,245 Lowest | 35,750 ₹35,750 | 35,500 ₹35,500 |
| 1.02 | 200 mm dia, P.N.-1.6, cast iron double flanged single door swing non-return valve generally conforming to IS:5312 Part I, having body, door, cover in graded cast iron to IS:210 Gr.FG200, body and door rings & bearing block of leaded tin bronze to IS:318 Gr.LTB 2 (350mm & above), hinge pin of st.st.AISI410, valve suitable for a maximum working pressure of 16 kg/cm2 (Seat test) & body tested to 24 kg/Sqcm.(Make:-IVI/Jupiter/Other approved make)(Delivery side of Pump No-01) | 1 | No | 26,883 ₹26,883 Lowest | 27,150 ₹27,150 | 26,920 ₹26,920 |
| 1.03 | Taking out of old and damaged valve of any type from the existing line after dismantling of Flange Joint or Socket Joint and fitting, fixing of New Valve.(Cost of dismantling of joint and renewing the same to be added with this item to complete the job in all respect ), repairing of flange joint after dismantling the joints, removing the unserviceable rubber insertion and supply new rubber insertion and supply upto 50 % of new nuts and bolts all complete including necessary earth work dewatering & supply of washer etc. all complete as per direction of E.I.C. | 2 | Item | 1,045 ₹2,090 Lowest | 1,130 ₹2,260 | 1,060 ₹2,120 |
| 2.00Exhaust fan replacement at VCB Room:- | ||||||
| 2.01 | Supply of 450 mm sweep exhaust fan 220-240 V AC, 50 Hz.(Make:-Approved make) | 4 | Nos | 8,319 ₹33,276 Lowest | 8,360 ₹33,440 | 8,330 ₹33,320 |
| 2.02 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:-45 cm (18") | 4 | Nos | 507 ₹2,028 Lowest | 540 ₹2,160 | 525 ₹2,100 |
| 3.00Low lift cable rectification portion:- | ||||||
| 3.01 | Making straight through joint of 3 Core 10 mm2 Al Ar. Cable with 3 Core X 4 Sqmm submersible cable by supplying necessary seal kit to make joints leak proof all complete as per direction.(Without Kit) | 2 | Set | 500 ₹1,000 Lowest | 580 ₹1,160 | 550 ₹1,100 |
| 3.02 | Making straight through joint in between 3 core 10 mm2 Al Ar. Cable by supplying necessary seal kit to make joints leak proof all complete as per direction.(Without Kit) | 2 | Set | 500 ₹1,000 Lowest | 580 ₹1,160 | 550 ₹1,100 |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
31 Aug 2026, 4:00 pmClosed
Executive Engineer,AMD P.H.E dte
Office of the Executive Engineer,Asansol Mechanical Division,Public Health Engineering Directorate,SEN-RALEIGH ROAD,713305
Replacement of old damaged sluice and N.R.V. centrifugal pumps delivery line, exhaust fan of VCB Room, rewinding of open well submersible pump act as a dewatering pump at Pansuli Head Works Site under RCFA Part-III(Zone-I) water supply scheme.
2026_PHED_1037874_9
WBPHED/EE/AMD/ NIeT-24 of 2026-2027
Open Tender
Miscellaneous Works
Item Wise
15 days
Pansuli
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,000
8 Oct 2026
13 Aug 2026
2 Sept 2026
13 Aug 2026
31 Aug 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Valve replacement portion:- | |||||
| 1.01 | 200 mm dia, P.N.-1.6 cast iron double flanged Rising Spindle Sluice Valve generally confirming to IS:14846 having body door /dome/Bonnet and cover of cast Iron Gr FG 260, outside screen rising Spindle of IS 6603 Gr-12 cr-13, spindle nut & seat rings are Gunmetal as per 1S:318 LTB 2. Flanges flat faced and drilled to IS:1538 Part IV & VI, Valves are suitable for maximum working pressure of 16 kg/sqcm (seat test) and body tested to 24 kg/sqcm. All the valves should be tested by closed end method only.(Make:-IVI/Jupiter/Other approved make)(Delivery side of Pump No-03) | 1 | No | 3 | ₹3 |
| 1.02 | 200 mm dia, P.N.-1.6, cast iron double flanged single door swing non-return valve generally conforming to IS:5312 Part I, having body, door, cover in graded cast iron to IS:210 Gr.FG200, body and door rings & bearing block of leaded tin bronze to IS:318 Gr.LTB 2 (350mm & above), hinge pin of st.st.AISI410, valve suitable for a maximum working pressure of 16 kg/cm2 (Seat test) & body tested to 24 kg/Sqcm.(Make:-IVI/Jupiter/Other approved make)(Delivery side of Pump No-01) | 1 | No | 4 | ₹4 |
| 1.03 | Taking out of old and damaged valve of any type from the existing line after dismantling of Flange Joint or Socket Joint and fitting, fixing of New Valve.(Cost of dismantling of joint and renewing the same to be added with this item to complete the job in all respect ), repairing of flange joint after dismantling the joints, removing the unserviceable rubber insertion and supply new rubber insertion and supply upto 50 % of new nuts and bolts all complete including necessary earth work dewatering & supply of washer etc. all complete as per direction of E.I.C. | 2 | Item | 5 | ₹10 |
| 2Exhaust fan replacement at VCB Room:- | |||||
| 2.01 | Supply of 450 mm sweep exhaust fan 220-240 V AC, 50 Hz.(Make:-Approved make) | 4 | Nos | 7 | ₹28 |
| 2.02 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:-45 cm (18") | 4 | Nos | 8 | ₹32 |
| 3Low lift cable rectification portion:- | |||||
| 3.01 | Making straight through joint of 3 Core 10 mm2 Al Ar. Cable with 3 Core X 4 Sqmm submersible cable by supplying necessary seal kit to make joints leak proof all complete as per direction.(Without Kit) | 2 | Set | 10 | ₹20 |
| 3.02 | Making straight through joint in between 3 core 10 mm2 Al Ar. Cable by supplying necessary seal kit to make joints leak proof all complete as per direction.(Without Kit) | 2 | Set | 11 | ₹22 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 0.53 MB
Tendernotice_3.pdf
PDF • 0.38 MB
BOQ_2549729.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .